-
Background measurements and detector response studies for ISMRAN experiment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) ex…
▽ More
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) experiment at very short baseline located at Dhruva research reactor facility. It is enclosed by a shielding made of 10 cm thick lead and 10 cm thick borated polyethylene to minimize the backgrounds and is mounted on a movable base structure, situated at $\sim$ 13 m away from the reactor core. These measurements are useful in the context of the ISMRAN detector setup that will be used to detect the reactor $\mathrm{\overlineν_{e}}$ and measure its energy spectrum through the inverse beta decay (IBD) process. In this paper, we present the energy resolution model and energy non-linearity model of PSB and the cosmogenic muon-induced background, based on the sum of their energy depositions and number of hit bars. Reconstructed sum energy spectrum and number of hit bars distribution for $\mathrm{{}^{22}Na}$ radioactive source has been compared with Geant4 based Monte Carlo simulations. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 11 January, 2023; v1 submitted 27 November, 2022;
originally announced November 2022.
-
Evaluation of the response of plastic scintillator bars and measurement of neutron capture time in non-reactor environment for the ISMRAN experiment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will b…
▽ More
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will be used to detect the reactor anti-neutrinos (${\bar{\ensuremathν}}_{e}$) and measure its energy spectra, through the inverse beta decay (IBD) process. A GEANT4 based Monte Carlo (MC) simulation is used to understand the optical transmission, energy resolution and energy non-linearity of the ISMRAN detector. A detailed analysis procedure has been developed to understand the natural radioactive, cosmogenic and cosmic muon-induced backgrounds with the ISMRAN detector setup in a non-reactor environment, based on their energy deposition, number of bars hit as well as topological event selection criteria in position and time for triggered events. Data and MC simulated distributions of reconstructed sum energy and number of bars hit has been compared for the radioactive $γ$ + positron source such as $\mathrm{{}^{22}Na}$ placed at the center of the ISMRAN array. Fast neutron energy response and capture time distribution in ISMRAN array has been studied using a novel technique involving Time of Flight (TOF) of the measured fast neutrons. The observed characteristic neutron capture time ( $τ$ ) of 68.29 $\pm$ 9.48 $μ$s is in good agreement with $\sim$65 $μ$s obtained from MC simulation. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 6 August, 2022;
originally announced August 2022.
-
Measurements using a prototype array of plastic scintillator bars for reactor based electron anti-neutrino detection
Authors:
P. K. Netrakanti,
D. Mulmule,
D. K. Mishra,
S. P. Behera,
R. Dey,
R. Sehgal,
S. K. Sinha,
V. Jha,
L. M. Pant
Abstract:
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy d…
▽ More
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embedding technique is used to estimate the efficiencies from a data driven background study. The obtained anti-neutrino like events in RON condition are 218 $\pm$ 50 (stat) $\pm$ 37 (sys) after background subtraction. The obtained results are compared with theoretical estimation which yields 214 $\pm$ 32 (sys) anti-neutrino events for the RON condition.
△ Less
Submitted 28 December, 2021; v1 submitted 24 December, 2021;
originally announced December 2021.
-
Cosmic ray measurements using the ISMRAN setup in a non-reactor environment
Authors:
S. P. Behera,
R. Sehgal,
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
V. Jha,
L. M. Pant
Abstract:
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muo…
▽ More
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muons has been measured and compared with Monte Carlo expectations. The detector setup was further used to measure the lifetime distribution of stopped muons and extract their rates inside the detector matrix. The measured spectra of decaying muons and associated electrons show a good agreement with the MC simulations performed through GEANT4 simulation.
△ Less
Submitted 2 June, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
D. Mulmule,
T. Patel,
P. S. Sarkar,
V. Jha,
L. M. Pant
Abstract:
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse…
▽ More
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.
△ Less
Submitted 4 November, 2021; v1 submitted 15 October, 2021;
originally announced October 2021.
-
Time-Resolved Vibrational Spectroscopy to Measure Lifetime of the E$^3Π_g(v=3)$ state of Molecular Iodine
Authors:
Sanjib Thapa,
Lok Pant,
Briana Vamosi,
Michael Saaranen,
S. Burcin Bayram
Abstract:
The lifetime of the $E^3Π_g(v=3)$ state of molecular iodine was measured in the gas phase at room temperature. The $E^3Π_g$ state was selectively populated by two sequential nanosecond pulse laser excitation. Resolved molecular fluorescence for the $B^3Π_u^+\leftarrow E^3Π_g$ was analyzed and the lifetime of the $E(v=3)$ state, measured using a time-correlated single photon counting technique, is…
▽ More
The lifetime of the $E^3Π_g(v=3)$ state of molecular iodine was measured in the gas phase at room temperature. The $E^3Π_g$ state was selectively populated by two sequential nanosecond pulse laser excitation. Resolved molecular fluorescence for the $B^3Π_u^+\leftarrow E^3Π_g$ was analyzed and the lifetime of the $E(v=3)$ state, measured using a time-correlated single photon counting technique, is to be $τ=21 (2)$ ns.
△ Less
Submitted 6 September, 2021;
originally announced September 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.
-
Active-sterile neutrino mixing constraint using reactor antineutrinos with the ISMRAN set-up
Authors:
S. P. Behera,
D. K. Mishra,
L. M. Pant
Abstract:
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near a…
▽ More
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near and far positions from the given reactor core. Results extracted in the later case are independent of the theoretical prediction of the reactor anti-neutrino spectrum and detector related systematic uncertainties. Our analysis shows that the results obtained from the measurement carried out at a combination of the near and far detector positions are improved significantly at higher $Δm^{2}_{41}$ compared to the ones obtained with the measurement at a single detector position only. It is found that the best possible combination of near and far detector positions from a 100 MW$_{th}$ power DHRUVA research reactor core are 7 m and 9 m, respectively, for which ISMRAN set-up can exclude in the range 1.4 $eV^{2} \leq Δm^{2}_{41} \leq$ 4.0 $eV^{2}$ of reactor antineutrino anomaly region along with the present best-fit point of active-sterile neutrino oscillation parameters. At those combinations of detector positions, the ISMRAN set-up can observe the active sterile neutrino oscillation with a 95$\%$ confidence level provided that $\sin^{2}2θ_{14}\geq 0.09$ at $Δm^{2}_{41}$ = 1 eV$^{2}$ for an exposure of 1 ton-yr. The active-sterile neutrino mixing sensitivity can be improved by about 22\% at the same exposure by placing the detector at near and far distances of 15 m and 17 m, respectively, from the compact proto-type fast breeder reactor (PFBR) facility which has a higher thermal power of 1250 MW$_{th}$.
△ Less
Submitted 21 July, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
Machine learning technique to improve anti-neutrino detection efficiency for the ISMRAN experiment
Authors:
D. Mulmule,
P. K. Netrakanti,
L. M. Pant,
B. K. Nayak
Abstract:
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and…
▽ More
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and delayed neutron from IBD will provide the signature of $\barν_e$ event in ISMRAN. The number of segments with energy deposit ($\mathrm{N_{bars}}$) and sum total of these deposited energies are used as discriminants for identifying prompt positron event and delayed neutron capture event. However, a simple cut based selection of above variables leads to a low $\barν_e$ signal detection efficiency due to overlap** region of $\mathrm{N_{bars}}$ and sum energy for the prompt and delayed events. Multivariate analysis (MVA) tools, employing variables suitably tuned for discrimination, can be useful in such scenarios. In this work we report the results from an application of artificial neural network -- the multilayer perceptron (MLP), particularly the Bayesian extension -- MLPBNN, to the simulated signal and background events in ISMRAN. The results from application of MLP to classify prompt positron events from delayed neutron capture events on Hydrogen, Gadolinium nuclei and also from the typical reactor $γ$-ray and fast neutron backgrounds is reported. An enhanced efficiency of $\sim$91$\%$ with a background rejection of $\sim$73$\%$ for prompt selection and an efficiency of $\sim$89$\%$ with a background rejection of $\sim$71$\%$ for the delayed capture event, is achieved using the MLPBNN classifier for the ISMRAN experiment.
△ Less
Submitted 20 May, 2020; v1 submitted 2 January, 2020;
originally announced January 2020.
-
High Rate RPC detector for LHC
Authors:
F. Lagarde,
A. Fagot,
M. Gul,
C. Roskas,
M. Tytgat,
N. Zaganidis,
S. Fonseca De Souza,
A. Santoro,
F. Torres Da Silva De Araujo,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
D. Han,
W. Yi,
C. Avila,
A. Cabrera
, et al. (77 additional authors not shown)
Abstract:
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The…
▽ More
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
A plastic scintillator array for reactor based anti-neutrino studies
Authors:
D. Mulmule,
S. P. Behera,
P. K. Netrakanti,
D. K. Mishra,
V. K. S. Kashyap,
V. Jha,
L. M. Pant,
B. K. Nayak,
A. Saxena
Abstract:
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event cha…
▽ More
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event characterization in the reactor and non-reactor environment. The data acquisition system based on waveform digitizers is being used for pulse processing and event triggering. Monte-Carlo based simulations using GEANT4 are performed to optimize lead (Pb) and borated polyethylene (BP) shielding for background reduction and to study the positron, neutron and $γ$-ray response in the ISMRAN detector. Characterization of plastic scintillator detectors with known radioactive sources is done for energy, timing and position measurements. Using the energy summation and bar multiplicity selection, coincident events from $\mathrm{{}^{60}Co}$ decay are reconstructed in non-reactor environment. Results from background measurements using various detectors are quantified in reactor ON and OFF condition. The shielding of 10 cm Pb and 10 cm BP along with the requirement of hits in multiple bars, reduces the uncorrelated background in reactor ON condition.
△ Less
Submitted 6 December, 2018; v1 submitted 12 June, 2018;
originally announced June 2018.
-
R&D towards the CMS RPC Phase-2 upgrade
Authors:
A. Fagot,
A. Cimmino,
S. Crucy,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Aly,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
V. Bhatnagar
, et al. (71 additional authors not shown)
Abstract:
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle…
▽ More
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.
△ Less
Submitted 14 June, 2016;
originally announced June 2016.
-
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment
Authors:
M. Shopova,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
G. Sultanov,
M. Rodozov,
S. Stoykova,
Y. Assran,
A. Sayed,
A. Radi,
S. Aly,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
A. Cimmino
, et al. (71 additional authors not shown)
Abstract:
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L…
▽ More
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.
△ Less
Submitted 22 May, 2016;
originally announced May 2016.
-
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are…
▽ More
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Physics Potential of the ICAL detector at the India-based Neutrino Observatory (INO)
Authors:
The ICAL Collaboration,
Shakeel Ahmed,
M. Sajjad Athar,
Rashid Hasan,
Mohammad Salim,
S. K. Singh,
S. S. R. Inbanathan,
Venktesh Singh,
V. S. Subrahmanyam,
Shiba Prasad Behera,
Vinay B. Chandratre,
Nitali Dash,
Vivek M. Datar,
V. K. S. Kashyap,
Ajit K. Mohanty,
Lalit M. Pant,
Animesh Chatterjee,
Sandhya Choubey,
Raj Gandhi,
Anushree Ghosh,
Deepak Tiwari,
Ali Ajmi,
S. Uma Sankar,
Prafulla Behera,
Aleena Chacko
, et al. (67 additional authors not shown)
Abstract:
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the mul…
▽ More
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the multi-GeV range. This study will be crucial to address some of the outstanding issues in neutrino oscillation physics, including the fundamental issue of neutrino mass hierarchy. In this document, we present the physics potential of the detector as obtained from realistic detector simulations. We describe the simulation framework, the neutrino interactions in the detector, and the expected response of the detector to particles traversing it. The ICAL detector can determine the energy and direction of the muons to a high precision, and in addition, its sensitivity to multi-GeV hadrons increases its physics reach substantially. Its charge identification capability, and hence its ability to distinguish neutrinos from antineutrinos, makes it an efficient detector for determining the neutrino mass hierarchy. In this report, we outline the analyses carried out for the determination of neutrino mass hierarchy and precision measurements of atmospheric neutrino mixing parameters at ICAL, and give the expected physics reach of the detector with 10 years of runtime. We also explore the potential of ICAL for probing new physics scenarios like CPT violation and the presence of magnetic monopoles.
△ Less
Submitted 9 May, 2017; v1 submitted 27 May, 2015;
originally announced May 2015.
-
Performance of the gas gain monitoring system of the CMS RPC muon detector
Authors:
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
Y. Ban,
J. Cai,
Q. Li,
S. Liu,
S. Qian,
D. Wang,
Z. Xu,
F. Zhang,
Y. Choi,
D. Kim,
S. Choi,
B. Hong,
J. W. Kang,
M. Kang,
J. H. Kwon,
K. S. Lee,
S. K. Park
, et al. (60 additional authors not shown)
Abstract:
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
△ Less
Submitted 27 December, 2014;
originally announced December 2014.
-
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
W. Ahmed,
W. Ahmed,
P. Altieri,
R. Aly,
C. Asawatangtrakuldee,
A. Ashfaq,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
P. Barria,
L. Benussi,
V. Bhopatkar,
S. Bianco,
J. Bos,
O. Bouhali,
S. Braibant,
S. Buontempo
, et al. (113 additional authors not shown)
Abstract:
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi…
▽ More
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.
△ Less
Submitted 8 December, 2014; v1 submitted 30 November, 2014;
originally announced December 2014.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.