-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Technical Design Report for the PANDA Barrel DIRC Detector
Authors:
PANDA Collaboration
Abstract:
This documents describes the technical design and the expected performance of the Barrel DIRC detector for the PANDA experiment. The Barrel DIRC will provide hadronic charged particle identification in the polar angle range of $22^\circ$ to $140^\circ$ for particle momenta between 0.5 GeV/c and 3.5 GeV/c.
The design is based on the successful BaBar DIRC with several key improvements. The perform…
▽ More
This documents describes the technical design and the expected performance of the Barrel DIRC detector for the PANDA experiment. The Barrel DIRC will provide hadronic charged particle identification in the polar angle range of $22^\circ$ to $140^\circ$ for particle momenta between 0.5 GeV/c and 3.5 GeV/c.
The design is based on the successful BaBar DIRC with several key improvements. The performance and system cost were optimized in detailed detector simulations and validated with full system prototypes using particle beams at GSI and CERN. The final design meets or exceeds the PID goal of clean $π/K$ separation with at least 3 standard deviations over the entire phase space of charged kaons in the Barrel DIRC.
△ Less
Submitted 29 September, 2017;
originally announced October 2017.
-
Technical Design Report for the Panda Forward Spectrometer Calorimeter
Authors:
PANDA collaboration
Abstract:
This document is devoted to the electromagnetic calorimeter of the Forward Spectrometer and describes the design considerations, the technical layout, the expected performance, and the production readiness.
This document is devoted to the electromagnetic calorimeter of the Forward Spectrometer and describes the design considerations, the technical layout, the expected performance, and the production readiness.
△ Less
Submitted 10 April, 2017;
originally announced April 2017.
-
Methods, Analysis, and the Treatment of Systematic Errors for the Electron Electric Dipole Moment Search in Thorium Monoxide
Authors:
ACME Collaboration,
Jacob Baron,
Wes C. Campbell,
David DeMille,
John M. Doyle,
Gerald Gabrielse,
Yulia V. Gurevich,
Paul W. Hess,
Nicholas R. Hutzler,
Emil Kirilov,
Ivan Kozyryev,
Brendon R. O'Leary,
Cristian D. Panda,
Maxwell F. Parsons,
Benjamin Spaun,
Amar C. Vutha,
Adam D. West,
Elizabeth P. West
Abstract:
We recently set a new limit on the electric dipole moment of the electron (eEDM) (J. Baron et al., ACME collaboration, Science 343 (2014), 269-272), which represented an order-of-magnitude improvement on the previous limit and placed more stringent constraints on many CP-violating extensions to the Standard Model. In this paper we discuss the measurement in detail. The experimental method and asso…
▽ More
We recently set a new limit on the electric dipole moment of the electron (eEDM) (J. Baron et al., ACME collaboration, Science 343 (2014), 269-272), which represented an order-of-magnitude improvement on the previous limit and placed more stringent constraints on many CP-violating extensions to the Standard Model. In this paper we discuss the measurement in detail. The experimental method and associated apparatus are described, together with the techniques used to isolate the eEDM signal. In particular, we detail the way experimental switches were used to suppress effects that can mimic the signal of interest. The methods used to search for systematic errors, and models explaining observed systematic errors, are also described. We briefly discuss possible improvements to the experiment.
△ Less
Submitted 29 December, 2016;
originally announced December 2016.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Order of Magnitude Smaller Limit on the Electric Dipole Moment of the Electron
Authors:
ACME Collaboration,
Jacob Baron,
Wesley C. Campbell,
David DeMille,
John M. Doyle,
Gerald Gabrielse,
Yulia V. Gurevich,
Paul W. Hess,
Nicholas R. Hutzler,
Emil Kirilov,
Ivan Kozyryev,
Brendon R. O'Leary,
Cristian D. Panda,
Maxwell F. Parsons,
Elizabeth S. Petrik,
Ben Spaun,
Amar C. Vutha,
Adam D. West
Abstract:
The Standard Model (SM) of particle physics fails to explain dark matter and why matter survived annihilation with antimatter following the Big Bang. Extensions to the SM, such as weak-scale Supersymmetry, may explain one or both of these phenomena by positing the existence of new particles and interactions that are asymmetric under time-reversal (T). These theories nearly always predict a small,…
▽ More
The Standard Model (SM) of particle physics fails to explain dark matter and why matter survived annihilation with antimatter following the Big Bang. Extensions to the SM, such as weak-scale Supersymmetry, may explain one or both of these phenomena by positing the existence of new particles and interactions that are asymmetric under time-reversal (T). These theories nearly always predict a small, yet potentially measurable ($10^{-27}$-$10^{-30}$ $e$ cm) electron electric dipole moment (EDM, $d_e$), which is an asymmetric charge distribution along the spin ($\vec{S}$). The EDM is also asymmetric under T. Using the polar molecule thorium monoxide (ThO), we measure $d_e = (-2.1 \pm 3.7_\mathrm{stat} \pm 2.5_\mathrm{syst})\times 10^{-29}$ $e$ cm. This corresponds to an upper limit of $|d_e| < 8.7\times 10^{-29}$ $e$ cm with 90 percent confidence, an order of magnitude improvement in sensitivity compared to the previous best limits. Our result constrains T-violating physics at the TeV energy scale.
△ Less
Submitted 6 November, 2013; v1 submitted 28 October, 2013;
originally announced October 2013.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.