-
Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70
Authors:
Masahiro Yoshimoto,
Naoki Fukuda,
Riku Matsumura,
Daiki Nishimura,
Hideaki Otsu,
Yohei Shimizu,
Toshiyuki Sumikama,
Hiroshi Suzuki,
Hiroyuki Takahashi,
Hiroyuki Takeda,
Junki Tanaka,
Koichi Yoshida
Abstract:
In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams…
▽ More
In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams cannot attain charge state equilibrium in the IC gas. In this study, a xenon-based gas (Xe+CH4), exhibiting a sufficiently large charge state changing cross section, was used in the IC to reach charge state equilibrium. The responses of ICs with P-10 and the xenon-based gases were examined using 238U beams and cocktail radioactive isotope (RI) beams with Z=40-90 at the RI Beam Factory (RIBF). For 238U beams at 165-344 MeV/u, the P-10 gas IC yielded an energy resolution of 1.9-3.0% in full width at half maximum (FWHM), which proved inadequate for Z identification in the uranium region. In contrast, the xenon-based gas IC demonstrated a satisfactory energy resolution of 1.4-1.6%. When using cocktail RI beams, a Z resolution of 1.28 and 0.74 was achieved by the P-10 and the xenon-based gas ICs, respectively, for beams with Z=84-88 at 200 MeV/u. The contrast in Z resolutions between the P-10 and the xenon-based gas ICs was effectively elucidated by the energy loss straggling model, incorporating collisional straggling and straggling due to charge state changes in the IC gases. The xenon-based gas IC, with more than 3sigma Z separation across a broad Z range (Z=40-90), emerged as a practical solution for Z identification of heavy ion beams.
△ Less
Submitted 9 July, 2024; v1 submitted 10 January, 2024;
originally announced January 2024.
-
Silicon tracker array for RIB experiments at SAMURAI
Authors:
A. I. Stefanescu,
V. Panin,
L. Trache,
T. Motobayashi,
H. Otsu,
A. Saastamoinen,
T. Uesaka,
L. Stuhl,
J. Tanaka,
D. Tudor,
I. C. Stefanescu,
A. E. Spiridon,
K. Yoneda,
H. Baba,
M. Kurokawa,
Y. Togano,
Z. Halasz,
M. Sasano,
S. Ota,
Y. Kubota,
D. S. Ahn,
T. Kobayashi,
Z. Elekes,
N. Fukuda,
H. Takeda
, et al. (27 additional authors not shown)
Abstract:
This work describes a silicon tracker system developed for experiments with proton-rich radioactive ion beams at the SAMURAI superconducting spectrometer of RIBF at RIKEN. The system is designed for accurate angular reconstruction and atomic number identification of relativistic heavy ions and protons which are simultaneously produced in reactions motivated by studies of proton capture reactions o…
▽ More
This work describes a silicon tracker system developed for experiments with proton-rich radioactive ion beams at the SAMURAI superconducting spectrometer of RIBF at RIKEN. The system is designed for accurate angular reconstruction and atomic number identification of relativistic heavy ions and protons which are simultaneously produced in reactions motivated by studies of proton capture reactions of interest for nuclear astrophysics. The technical characteristics of the tracking array are described in detail as are its performance in two pilot experiments. The physics justification for such a system is also presented.
△ Less
Submitted 13 July, 2023;
originally announced July 2023.
-
The S$π$RIT Time Projection Chamber
Authors:
J. Barney,
J. Estee,
W. G. Lynch,
T. Isobe,
G. Jhang,
M. Kurata-Nishimura,
A. B. McIntosh,
T. Murakami,
R. Shane,
S. Tangwancharoen,
M. B. Tsang,
G. Cerizza,
M. Kaneko,
J. W. Lee,
C. Y. Tsang,
R. Wang,
C. Anderson,
H. Baba,
Z. Chajecki,
M. Famiano,
R. Hodges-Showalter,
B. Hong,
T. Kobayashi,
P. Lasko,
J. Łukasik
, et al. (15 additional authors not shown)
Abstract:
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096…
▽ More
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs readout electronics. The S$π$RIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Details of the S$π$RIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and experimental data.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.