DANTE Digital Pulse Processor for XRF and XAS experiments
Authors:
F. J. Iguaz,
L. Bombelli,
S. Meo,
F. Orsini,
S. Schöeder,
A. Tocchio,
N. Trcera,
D. Vantelon
Abstract:
DANTE is a new Digital Pulse Processor (DPP) developed for fluorescence detectors, like silicon drift detectors (SDDs) or High Purity Germanium detectors (HPGe), used in X-ray Fluorescence (XRF) and X-ray Absorption Spectroscopy (XAS) experiments at synchrotron facilities. Its main features are its optimal energy resolution and peak stability for detector count rate values up to 1-2 Mcps, and its…
▽ More
DANTE is a new Digital Pulse Processor (DPP) developed for fluorescence detectors, like silicon drift detectors (SDDs) or High Purity Germanium detectors (HPGe), used in X-ray Fluorescence (XRF) and X-ray Absorption Spectroscopy (XAS) experiments at synchrotron facilities. Its main features are its optimal energy resolution and peak stability for detector count rate values up to 1-2 Mcps, and its enhanced rejection of pile-up events. In this paper, we present the first complete evaluation of DANTE performance in SOLEIL synchrotron facility. DANTE has been tested in laboratory with an X-ray generator source and in different experiments at LUCIA and PUMA beamlines at SOLEIL.
△ Less
Submitted 17 May, 2023; v1 submitted 16 March, 2023;
originally announced March 2023.
-
Detection limit of next-generation of multi-element germanium detectors in the context of Environmental science
Authors:
F. J. Iguaz,
T. Saleem,
E. Fonda,
G. Landrot,
L. Manzanillas,
F. Orsini
Abstract:
One of the main challenges in Environmental sciences is the identification and chemical evolution of polluting traces (e.g, cadmium or antimony) in soil, which requires long acquistion times for accurate measurements at synchrotron facilities. In this context, the potential of a new generation multi-element germanium detectors to identify traces at 0.1-1~ppm in a reasonable time has been studied u…
▽ More
One of the main challenges in Environmental sciences is the identification and chemical evolution of polluting traces (e.g, cadmium or antimony) in soil, which requires long acquistion times for accurate measurements at synchrotron facilities. In this context, the potential of a new generation multi-element germanium detectors to identify traces at 0.1-1~ppm in a reasonable time has been studied using Allpix Squared framework. This code has been customized to include the three dimensional electric and weighting field maps generated by COMSOL Multiphysics software, and several features to model the sample environment at SOLEIL synchrotron and the signal response of a germanium detector equipped with a Digital Pulse Processor (DPP). The full simulation chain has been validated by experimental data from SAMBA beamline of SOLEIL synchrotron. This work presents a first estimation of the detection limit to cadmium traces in a soil sample for a future multi-element germanium detector, using this simulation chain.
△ Less
Submitted 15 April, 2022;
originally announced April 2022.
-
The accomplishment of the Engineering Design Activities of IFMIF/EVEDA: The European Japanese project towards a Li(d,xn) fusion relevant neutron source
Authors:
J. Knaster,
A. Ibarra,
J. Abal,
A. Abou Sena,
F. Arbeiter,
F. Arranz,
J. M. Arroyo,
E. Bargallo,
P. Y. Beauvais,
D. Bernardi,
N. Casal,
J. M. Carmona,
N. Chauvin,
M. Comunian,
O. Delferriere,
A. Delgado,
P. Diaz Arocas,
U. Fischer,
M. Frisoni,
A. Garcia,
P. Garin,
R. Gobin,
P. Gouat,
F. Groesche,
R. Heidinger
, et al. (42 additional authors not shown)
Abstract:
The International Fusion Materials Irradiation Facility (IFMIF), presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the frame of the Broader Approach Agreement between Europe and Japan, accomplished in summer 2013, on schedule, its EDA phase with the release of the engineering design report of the IFMIF plant, which is here described. Many improvements of…
▽ More
The International Fusion Materials Irradiation Facility (IFMIF), presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the frame of the Broader Approach Agreement between Europe and Japan, accomplished in summer 2013, on schedule, its EDA phase with the release of the engineering design report of the IFMIF plant, which is here described. Many improvements of the design from former phases are implemented, particularly a reduction of beam losses and operational costs thanks to the superconducting accelerator concept, the re-location of the quench tank outside the test cell (TC) with a reduction of tritium inventory and a simplification on its replacement in case of failure, the separation of the irradiation modules from the shielding block gaining irradiation flexibility and enhancement of the remote handling equipment reliability and cost reduction, and the water cooling of the liner and biological shielding of the TC, enhancing the efficiency and economy of the related sub-systems. In addition, the maintenance strategy has been modified to allow a shorter yearly stop of the irradiation operations and a more careful management of the irradiated samples. The design of the IFMIF plant is intimately linked with the EVA phase carried out since the entry into force of IFMIF/EVEDA in June 2007.
△ Less
Submitted 28 December, 2021;
originally announced December 2021.
-
Allpix-Squared Simulations of Multi-element Germanium Detectors for Synchrotron Applications
Authors:
T. Saleem,
F. J. Iguaz,
F. Orsini
Abstract:
X-rays spectroscopy experiments at synchrotron facilities were limited for many years by the maximum input-count rate and the signal-to-background ratio of germanium fluorescence detectors. These limitations are related to the germanium semiconductor device, the sensor configuration and its response to the incident X-ray flux at different energies. In order to understand and quantify such limitati…
▽ More
X-rays spectroscopy experiments at synchrotron facilities were limited for many years by the maximum input-count rate and the signal-to-background ratio of germanium fluorescence detectors. These limitations are related to the germanium semiconductor device, the sensor configuration and its response to the incident X-ray flux at different energies. In order to understand and quantify such limitations, physics simulation of the detector response is a powerful tool to provide guidelines for designing, prototy** and improving detectors, as well as modelling experimental environments, which reduces time and cost of development. For this purpose, a first complete and operational simulation chain based on Allpix Squared framework is presented, customized to multi-element germanium detectors and combined with three-dimensional simulations of the electric field and the weighting potential, based on COMSOL Multiphysics. Based on this simulation chain, a quantification of charge sharing effect as well as signal-to-background ratio at different beam energies has been made for a germanium detector equipped with and without collimator. In addition, two experimental measurements have been performed on the SAMBA beamline at SOLEIL synchrotron. The experimental data were used to set up the full simulation chain and good agreements have been observed between data and simulation.
△ Less
Submitted 17 January, 2022; v1 submitted 22 June, 2021;
originally announced June 2021.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Experimental determination of the frequency and field dependence of Specific Loss Power in Magnetic Fluid Hyperthermia
Authors:
M. Cobianchi,
A. Guerrini,
M. Avolio,
C. Innocenti,
M. Corti,
P. Arosio,
F. Orsini,
C. Sangregorio,
A. Lascialfari
Abstract:
Magnetic nanoparticles are promising systems for biomedical applications and in particular for Magnetic Fluid Hyperthermia, a promising therapy that utilizes the heat released by such systems to damage tumor cells. We present an experimental study of the physical properties that influences the capability of heat release, i.e. the Specific Loss Power, SLP, of three biocompatible ferrofluid samples…
▽ More
Magnetic nanoparticles are promising systems for biomedical applications and in particular for Magnetic Fluid Hyperthermia, a promising therapy that utilizes the heat released by such systems to damage tumor cells. We present an experimental study of the physical properties that influences the capability of heat release, i.e. the Specific Loss Power, SLP, of three biocompatible ferrofluid samples having a magnetic core of maghemite with different core diameter d= 10.2, 14.6 and 19.7 nm. The SLP was measured as a function of frequency f and intensity of the applied alternating magnetic field H, and it turned out to depend on the core diameter, as expected. The results allowed us to highlight experimentally that the physical mechanism responsible for the heating is size-dependent and to establish, at applied constant frequency, the phenomenological functional relationship SLP=cH^x, with 2<x<3 for all samples. The x-value depends on sample size and field frequency/ intensity, here chosen in the typical range of operating magnetic hyperthermia devices. For the smallest sample, the effective relaxation time Teff=19.5 ns obtained from SLP data is in agreement with the value estimated from magnetization data, thus confirming the validity of the Linear Response Theory model for this system at properly chosen field intensity and frequency.
△ Less
Submitted 10 April, 2017;
originally announced April 2017.
-
Development of a Depleted Monolithic CMOS Sensor in a 150 nm CMOS Technology for the ATLAS Inner Tracker Upgrade
Authors:
T. Wang,
P. Rymaszewski,
M. Barbero,
Y. Degerli,
S. Godiot,
F. Guilloux,
T. Hemperek,
T. Hirono,
H. Krüger,
J. Liu,
F. Orsini,
P. Pangaud,
A. Rozanov,
N. Wermes
Abstract:
The recent R&D focus on CMOS sensors with charge collection in a depleted zone has opened new perspectives for CMOS sensors as fast and radiation hard pixel devices. These sensors, labelled as depleted CMOS sensors (DMAPS), have already shown promising performance as feasible candidates for the ATLAS Inner Tracker (ITk) upgrade, possibly replacing the current passive sensors. A further step to exp…
▽ More
The recent R&D focus on CMOS sensors with charge collection in a depleted zone has opened new perspectives for CMOS sensors as fast and radiation hard pixel devices. These sensors, labelled as depleted CMOS sensors (DMAPS), have already shown promising performance as feasible candidates for the ATLAS Inner Tracker (ITk) upgrade, possibly replacing the current passive sensors. A further step to exploit the potential of DMAPS is to investigate the suitability of equip** the outer layers of the ATLAS ITk upgrade with fully monolithic CMOS sensors. This paper presents the development of a depleted monolithic CMOS pixel sensor designed in the LFoundry 150 nm CMOS technology, with the focus on design details and simulation results.
△ Less
Submitted 3 November, 2016;
originally announced November 2016.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
M.i.p. detection performances of a 100 us read-out CMOS pixel sensor with digitised outputs
Authors:
Marc Winter,
Jerome Baudot,
Auguste Besson,
Claude Colledani,
Yavuz Degerli,
Rita De Masi,
Andrei Dorokhov,
Guy Doziere,
Wojciech Dulinski,
Marie Gelin,
Fabrice Guilloux,
Abdelkader Himmi,
Christine Hu-Guo,
Frederic Morel,
Fabienne Orsini,
Isabelle Valin,
Georgios Voutsinas
Abstract:
Swift, high resolution CMOS pixel sensors are being developed for the ILC vertex detector, aiming to allow approaching the interaction point very closely. A major issue is the time resolution of the sensors needed to deal with the high occupancy generated by the beam related background. A 128x576 pixel sensor providing digitised outputs at a read-out time of 92.5 us, was fabricated in 2008 withi…
▽ More
Swift, high resolution CMOS pixel sensors are being developed for the ILC vertex detector, aiming to allow approaching the interaction point very closely. A major issue is the time resolution of the sensors needed to deal with the high occupancy generated by the beam related background. A 128x576 pixel sensor providing digitised outputs at a read-out time of 92.5 us, was fabricated in 2008 within the EU project EUDET, and tested with charged particles at the CERN-SPS. Its prominent performances in terms of noise, detection efficiency versus fake hit rate, spatial resolution and radiation tolerance are overviewed. They validate the sensor architecture.
△ Less
Submitted 16 February, 2009;
originally announced February 2009.
-
Radiation Induced Effects in a Monolithic Active Pixel Sensor : The Mimosa8 Chip
Authors:
Nicolas Fourches,
M. Besançon,
R. Chipaux,
Y. Li,
P. Lutz,
F. Orsini
Abstract:
We have studied the effects of ionizing irradiation from a 60Co source and the effects of neutron irradiation on a Monolithic Active Pixel Sensor Chip(MIMOSA8). A previous report was devoted solely to the neutron-induced effects. We show that extended defects due to the neutron damage changes the distribution of the pixels pedestals. This is mainly due to the increase of the dark generation curr…
▽ More
We have studied the effects of ionizing irradiation from a 60Co source and the effects of neutron irradiation on a Monolithic Active Pixel Sensor Chip(MIMOSA8). A previous report was devoted solely to the neutron-induced effects. We show that extended defects due to the neutron damage changes the distribution of the pixels pedestals. This is mainly due to the increase of the dark generation current due to the presence of deep traps in the depleted zones of the sensors. Alternatively, the exposure to ionizing irradiation increases the pedestals in a more homogeneous way, this coming from the generation of interface states at the Si/SiO2 interface supplemented by the presence of positively charged traps in the oxides. the sensors' leakage current is then increased. We discuss the results in view of increasing the radiation-hardness of the MAPS, bearing in mind that these chips were not designed with any rad-tol layout technique.
△ Less
Submitted 26 May, 2008;
originally announced May 2008.