Long term experience with perfluorobutane in COMPASS RICH
Authors:
F. Bradamante,
A. Bressan,
A. Cicuttin,
M. L. Crespo,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
W. Florian,
L. Garcia Ordonez,
M. Gregori,
A. Kerbizi,
S. Levorato,
A. Martin,
G. Menon,
R. S. Molina,
A. Moretti,
F. Tessarotto,
Triloki,
B. Valinoti
Abstract:
COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. We report on the experience gained in the 20 year-long operation of perfluorobutane as COMPASS RICH radiator. Very accurate values for the radiator gas refractive index are needed for high-performance particle identificat…
▽ More
COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. We report on the experience gained in the 20 year-long operation of perfluorobutane as COMPASS RICH radiator. Very accurate values for the radiator gas refractive index are needed for high-performance particle identification. The procedure has evolved over years and the one presently in use, which provides refractive index estimate at the 1 ppm level, is discussed. Perfluorobutane procurement is becoming challenging, and the minimization of material waste is now a priority for the protection of the environment. Commercially available perfluorobutane needs dedicated filtering before usage and typical material losses in the filtering procedure were around 30%. Recent efforts allowed us to reduce them to about 5%. A potential alternative to fluorocarbon radiators in gaseous RICHes is also presented.
△ Less
Submitted 3 August, 2023;
originally announced August 2023.
MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
L. García Ordóñez,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri
, et al. (7 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.