-
Creation, Control, and Modeling of NV Centers in Nanodiamonds
Authors:
Pietro Aprà,
Nour Hanne Amine,
Adam Britel,
Sofia Sturari,
Veronica Varzi,
Matteo Ziino,
Lorenzo Mino,
Paolo Olivero,
Federico Picollo
Abstract:
Sensing based on Nitrogen-Vacancy (NV) centers in nanodiamonds (NDs) offers significant potential across various applications. However, optimizing their quantum-optical properties remains challenging. This study focuses on enhancing and controlling the optical properties of NV centers in NDs through surface chemistry tuning and proton beam irradiation. Systematic thermal oxidations were performed…
▽ More
Sensing based on Nitrogen-Vacancy (NV) centers in nanodiamonds (NDs) offers significant potential across various applications. However, optimizing their quantum-optical properties remains challenging. This study focuses on enhancing and controlling the optical properties of NV centers in NDs through surface chemistry tuning and proton beam irradiation. Systematic thermal oxidations were performed to investigate the evolution of surface chemical groups using IR spectroscopy and their influence on optical properties using photoluminescence spectroscopy and PL decay measurements. Proton irradiation was explored over a wide range of fluences (10^14 to 10^17 cm^-2) to precisely control the NV center concentration, identifying conditions that maximize creation and emission intensity. Furthermore, NV center charge state control was achieved by analyzing the NV-/NV0 ratio with varying surface terminations and NV center concentrations. A novel predictive mathematical model was developed to evaluate the efficiencies of forming NV- and NV0. Although tested specifically with proton-irradiated NDs, this model has broad applicability, representing a significant advancement in predicting the outcomes of ion-beam-based color center generation in diamond.
△ Less
Submitted 1 July, 2024;
originally announced July 2024.
-
3D Printing in Microfluidics: Experimental Optimization of Droplet Size and Generation Time through Flow Focusing, Phase, and Geometry Variation
Authors:
Adam Britel,
Giulia Tomagra,
Pietro Aprà,
Veronica Varzi,
Sofia Sturari,
Nour-hanne Amine,
Paolo Olivero,
Federico Picollo
Abstract:
Droplet-based microfluidics systems have become widely used in recent years thanks to their advantages, varying from the possibility of handling small fluid volumes to directly synthesizing and encapsulating various living forms for biological-related applications. The effectiveness of such systems mainly depends on the ability to control some of these system's parameters, such as produced droplet…
▽ More
Droplet-based microfluidics systems have become widely used in recent years thanks to their advantages, varying from the possibility of handling small fluid volumes to directly synthesizing and encapsulating various living forms for biological-related applications. The effectiveness of such systems mainly depends on the ability to control some of these system's parameters, such as produced droplet size and formation time, which represents a challenging task. This work reports an experimental study on tuning droplet size and generation time in a flow-focusing geometry fabricated with stereolithography 3D printing by exploring the interplay of phase and geometrical parameters. We produced droplets at different low flow rates of continuous and dispersed phases to assess the effect of each of these phases on the droplets' size and formation time. We observed that smaller droplets were produced for high viscosity oil and water phase, along with high flow rates. In addition, changing the microfluidics channels' width, and morphology of the orifice has shown a similar effect on droplet size, as shown in the case of high-viscosity solutions. The variation of the bifurcation angle shows a noticeable variation in terms of the achieved droplet size and formation time. We further investigated the impact of modifying the width ratio of the continuous and dispersed phases on droplet formation
△ Less
Submitted 27 February, 2024;
originally announced February 2024.
-
A comprehensive study of the effect of thermally induced surface terminations on nanodiamonds electrical properties
Authors:
Sofia Sturari,
Veronica Varzi,
Pietro Aprà,
Adam Britel,
Nour-Hanne Amine,
Greta Andrini,
Emilio Corte,
Giulia Tomagra,
Lorenzo Mino,
Paolo Olivero,
Federico Picollo
Abstract:
Nanodiamonds (NDs) gained increasing attention in multiple research areas due to the possibility of tuning their physical and chemical features by functionalizing their surface. This has a crucial impact on their electrical properties, which are essential in applications such as the development of innovative sensors and in the biomedical field. The great interest in electrical conduction in NDs ha…
▽ More
Nanodiamonds (NDs) gained increasing attention in multiple research areas due to the possibility of tuning their physical and chemical features by functionalizing their surface. This has a crucial impact on their electrical properties, which are essential in applications such as the development of innovative sensors and in the biomedical field. The great interest in electrical conduction in NDs has driven the scientific community to its extensive investigation. The role of various functionalities has been considered and different conduction mechanisms have been proposed. In this work, we reported on a systematic study of the modification of the electrical properties of differently sized NDs, as a function of different thermal treatments in air, hydrogen or inert atmosphere. Samples were electrically characterized in controlled humidity conditions to consider the influence of water on conductivity. NDs electrical properties were interpreted in connection with their surface chemistry and structural features, probed with infrared and Raman spectroscopies. The presence of surface graphite, hydrogen terminations or water adsorbed on hydrophilic oxygen-containing functional groups rendered NDs more conductive. These moieties indeed enabled different conduction mechanisms, which were respectively graphite-mediated conduction, water-induced transfer do** and Grotthus mechanism in surface-adsorbed water. The effect of particles size on conductivity has also been evaluated and discussed. Our experimental findings shed light on the link between surface modifications and electrical properties of NDs, providing at the same time an interpretative key to understanding the effect of particles dimensions.
△ Less
Submitted 19 December, 2023;
originally announced December 2023.
-
Efficient activation of telecom emitters in silicon upon ns pulsed laser annealing
Authors:
G. Andrini,
G. Zanelli,
S. Ditalia Tchernij,
E. Corte,
E. Nieto Hernandez,
A. Verna,
M. Cocuzza,
E. Bernardi,
S. Virzì,
P. Traina,
I. P. Degiovanni,
M. Genovese,
P. Olivero,
J. Forneris
Abstract:
The recent demonstration of optically active telecom emitters makes silicon a compelling candidate for solid state quantum photonic platforms. Particularly fabrication of the G center has been demonstrated in carbon-rich silicon upon conventional thermal annealing. However, the high-yield controlled fabrication of these emitters at the wafer-scale still requires the identification of a suitable th…
▽ More
The recent demonstration of optically active telecom emitters makes silicon a compelling candidate for solid state quantum photonic platforms. Particularly fabrication of the G center has been demonstrated in carbon-rich silicon upon conventional thermal annealing. However, the high-yield controlled fabrication of these emitters at the wafer-scale still requires the identification of a suitable thermodynamic pathway enabling its activation following ion implantation. Here we demonstrate the efficient activation of G centers in high-purity silicon substrates upon ns pulsed laser annealing. The proposed method enables the non-invasive, localized activation of G centers by the supply of short non-stationary pulses, thus overcoming the limitations of conventional rapid thermal annealing related to the structural metastability of the emitters. A finite-element analysis highlights the strong non-stationarity of the technique, offering radically different defect-engineering capabilities with respect to conventional longer thermal treatments, paving the way to the direct and controlled fabrication of emitters embedded in integrated photonic circuits and waveguides.
△ Less
Submitted 10 April, 2024; v1 submitted 20 April, 2023;
originally announced April 2023.
-
4H-SiC Schottky diode radiation hardness assessment by IBIC microscopy
Authors:
Ettore Vittone,
Paolo Olivero,
Milko Jaksic,
Zeljko Pastuovic
Abstract:
We report findings on the Ion Beam Induced Charge (IBIC) characterization of a 4H-SiC Schottky barrier diode (SBD), in terms of the modification of the Charge Collection Efficiency (CCE) distribution induced by 20 MeV C ions irradiations with fluences ranging from 20 to 200 ions/um2. The lateral IBIC microscopy with 4 MeV protons over the SBD cross section, carried out on the pristine diode eviden…
▽ More
We report findings on the Ion Beam Induced Charge (IBIC) characterization of a 4H-SiC Schottky barrier diode (SBD), in terms of the modification of the Charge Collection Efficiency (CCE) distribution induced by 20 MeV C ions irradiations with fluences ranging from 20 to 200 ions/um2. The lateral IBIC microscopy with 4 MeV protons over the SBD cross section, carried out on the pristine diode evidenced the widening of the depletion layer extension as function of the applied bias and allowed the measurement of the minority carrier diffusion lengths. After the irradiation with C ions, lateral IBIC showed a significant modification of the CCE distribution, with a progressive shrinkage of the depletion layer as the fluence of the damaging C ions increases. A simple electrostatic model ruled out that the shrinkage is due to the implanted charge and ascribed the perturbation of the electrostatic landscape to radiation-induced defects with positive charge state.
△ Less
Submitted 10 November, 2022;
originally announced November 2022.
-
Spectral features of Pb-related color centers in diamond
Authors:
Sviatoslav Ditalia Tchernij,
Emilio Corte,
Tobias Lühmann,
Paolo Traina,
Sébastien Pezzagna,
Ivo Pietro Degiovanni,
Georgios Provatas,
Ekaterina Moreva,
Jan Meijer,
Paolo Olivero,
Marco Genovese,
Jacopo Forneris
Abstract:
We report on the systematic characterization of the optical properties of diamond color centers based on Pb impurities. An ensemble photoluminescence analysis of their spectral emission was performed at different excitation wavelengths in the 405-520 nm range and at different temperatures in the 4-300 K range. The series of observed spectral features consist of different emission lines associated…
▽ More
We report on the systematic characterization of the optical properties of diamond color centers based on Pb impurities. An ensemble photoluminescence analysis of their spectral emission was performed at different excitation wavelengths in the 405-520 nm range and at different temperatures in the 4-300 K range. The series of observed spectral features consist of different emission lines associated with Pb-related defects. Finally, a room-temperature investigation of single-photon emitters under 490.5 nm laser excitation is reported, revealing different spectral signatures with respect to those already reported under 514 nm excitation. This work represents a substantial progress with respect to previous studies on Pb-related color centers, both in the attribution of an articulated series of spectral features and in the understanding of the formation process of this type of defect, thus clarifying the potential of this system for high-impact applications in quantum technologies.
△ Less
Submitted 2 June, 2021;
originally announced June 2021.
-
Fluorine-based color centers in diamond
Authors:
S. Ditalia Tchernij,
T. Lühmann,
E. Corte,
F. Sardi,
F. Picollo,
P. Traina,
M. Brajkovic,
A. Crnjac,
S. Pezzagna,
I. P. Degiovanni,
E. Moreva,
P. Aprà,
P. Olivero,
Z. Siketić,
J. Meijer,
M. Genovese,
J. Forneris
Abstract:
We report on the creation and characterization of the luminescence properties of high-purity diamond substrates upon F ion implantation and subsequent thermal annealing. Their room-temperature photoluminescence emission consists of a weak emission line at 558 nm and of intense bands in the 600 - 750 nm spectral range. Characterization at liquid He temperature reveals the presence of a structured s…
▽ More
We report on the creation and characterization of the luminescence properties of high-purity diamond substrates upon F ion implantation and subsequent thermal annealing. Their room-temperature photoluminescence emission consists of a weak emission line at 558 nm and of intense bands in the 600 - 750 nm spectral range. Characterization at liquid He temperature reveals the presence of a structured set of lines in the 600 - 670 nm spectral range. We discuss the dependence of the emission properties of F-related optical centers on different experimental parameters such as the operating temperature and the excitation wavelength. The correlation of the emission intensity with F implantation fluence, and the exclusive observation of the afore-mentioned spectral features in F-implanted and annealed samples provides a strong indication that the observed emission features are related to a stable F-containing defective complex in the diamond lattice.
△ Less
Submitted 9 December, 2020; v1 submitted 28 September, 2020;
originally announced September 2020.
-
Biocompatible technique for nanoscale magnetic field sensing with Nitrogen-Vacancy centers
Authors:
Ettore Bernardi,
Ekaterina Moreva,
Paolo Traina,
Giulia Petrini,
Sviatoslav Ditalia Tchernij,
Jacopo Forneris,
Zelijko Pastuovic,
Ivo Pietro Degiovanni,
Paolo Olivero,
M. Genovese
Abstract:
The possibility of using Nitrogen-vacancy centers in diamonds to measure nanoscale magnetic fields with unprecedented sensitivity is one of the most significant achievements of quantum sensing. Here we present an innovative experimental set-up, showing an achieved sensitivity comparable to the state of the art ODMR protocols if the sensing volume is taken into account. The apparatus allows magneti…
▽ More
The possibility of using Nitrogen-vacancy centers in diamonds to measure nanoscale magnetic fields with unprecedented sensitivity is one of the most significant achievements of quantum sensing. Here we present an innovative experimental set-up, showing an achieved sensitivity comparable to the state of the art ODMR protocols if the sensing volume is taken into account. The apparatus allows magnetic sensing in biological samples such as individual cells, as it is characterized by a small sensing volume and full bio-compatibility. The sensitivity at different optical powers is studied to extend this technique to the intercellular scale.
△ Less
Submitted 16 June, 2020; v1 submitted 27 May, 2020;
originally announced May 2020.
-
Quantum micro-nano devices fabricated in diamond by femtosecond laser and ion irradiation
Authors:
Shane M. Eaton,
J. P. Hadden,
Vibhav Bharadwaj,
Jacopo Forneris,
Federico Picollo,
Federico Bosia,
Belen Sotillo,
Argyro N. Giakoumaki,
Ottavia Jedrkiewicz,
Andrea Chiappini,
Maurizio Ferrari,
Roberto Osellame,
Paul E. Barclay,
Paolo Olivero,
Roberta Ramponi
Abstract:
Diamond has attracted great interest as a quantum technology platform thanks to its optically active nitrogen vacancy center (NV). The NV's ground state spin can be read out optically exhibiting long spin coherence times of about 1 ms even at ambient temperatures. In addition, the energy levels of the NV are sensitive to external fields. These properties make NVs attractive as a scalable platform…
▽ More
Diamond has attracted great interest as a quantum technology platform thanks to its optically active nitrogen vacancy center (NV). The NV's ground state spin can be read out optically exhibiting long spin coherence times of about 1 ms even at ambient temperatures. In addition, the energy levels of the NV are sensitive to external fields. These properties make NVs attractive as a scalable platform for efficient nanoscale resolution sensing based on electron spins and for quantum information systems. Diamond photonics enhances optical interaction with NVs, beneficial for both quantum sensing and information. Diamond is also compelling for microfluidic applications due to its outstanding biocompatibility, with sensing functionality provided by NVs. However, it remains a significant challenge to fabricate photonics, NVs and microfluidics in diamond. In this Report, an overview is provided of ion irradiation and femtosecond laser writing, two promising fabrication methods for diamond based quantum technological devices. The unique capabilities of both techniques are described, and the most important fabrication results of color center, optical waveguide and microfluidics in diamond are reported, with an emphasis on integrated devices aiming towards high performance quantum sensors and quantum information systems of tomorrow
△ Less
Submitted 16 April, 2020;
originally announced April 2020.
-
Practical applications of quantum sensing: a simple method to enhance sensitivity of Nitrogen-Vacancy-based temperature sensors
Authors:
E. Moreva,
E. Bernardi,
P. Traina,
A. Sosso,
S. Ditalia Tchernij,
J. Forneris,
F. Picollo,
G. Brida,
Z. Pastuovic,
I. P. Degiovanni,
P. Olivero,
M. Genovese
Abstract:
Nitrogen-vacancy centers in diamond allow measurement of environment properties such as temperature, magnetic and electric fields at nanoscale level, of utmost relevance for several research fields, ranging from nanotechnologies to bio-sensing. The working principle is based on the measurement of the resonance frequency shift of a single nitrogen-vacancy center (or an ensemble of them), usually de…
▽ More
Nitrogen-vacancy centers in diamond allow measurement of environment properties such as temperature, magnetic and electric fields at nanoscale level, of utmost relevance for several research fields, ranging from nanotechnologies to bio-sensing. The working principle is based on the measurement of the resonance frequency shift of a single nitrogen-vacancy center (or an ensemble of them), usually detected by by monitoring the center photoluminescence emission intensity. Albeit several schemes have already been proposed, the search for the simplest and most effective one is of key relevance for real applications. Here we present a new continuous-wave lock-in based technique able to reach unprecedented sensitivity in temperature measurement at micro/nanoscale volumes (4.8 mK/Hz$^{1/2}$ in $μ$m$^3$). Furthermore, the present method has the advantage of being insensitive to the enviromental magnetic noise, that in general introduces a bias in the temperature measurement.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
Recent Results from Polycrystalline CVD Diamond Detectors
Authors:
RD42 Collaboration,
L. Bäni,
A. Alexopoulos,
M. Artuso,
F. Bachmair,
M. Bartosik,
H. Beck,
V. Bellini,
V. Belyaev,
B. Bentele,
A. Bes,
J. -M. Brom,
M. Bruzzi,
G. Chiodini,
D. Chren,
V. Cindro,
G. Claus,
J. Collot,
J. Cumalat,
A. Dabrowski,
R. D'Alessandro,
D. Dauvergne,
W. de Boer,
C. Dorfer,
M. Dünser
, et al. (87 additional authors not shown)
Abstract:
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse hei…
▽ More
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse height versus particle rate of unirradiated and irradiated polycrystalline CVD (pCVD) diamond pad detectors up to a particle flux of $20\,\mathrm{MHz/cm^2}$ and a fluence up to $4 \times 10^{15}\,n/\mathrm{cm^2}$.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
Nanodiamonds-induced effects on neuronal firing of mouse hippocampal microcircuits
Authors:
L. Guarina,
C. Calorio,
D. Gavello,
E. Moreva,
P. Traina,
A. Battiato,
S. Ditalia Tchernij,
J. Forneris,
M. Gai,
F. Picollo,
P. Olivero,
M. Genovese,
E. Carbone,
A. Marcantoni,
V. Carabelli
Abstract:
Fluorescent nanodiamonds (FND) are carbon-based nanomaterials that can efficiently incorporate optically active photoluminescent centers such as the nitrogen-vacancy complex, thus making them promising candidates as optical biolabels and drug-delivery agents. FNDs exhibit bright fluorescence without photobleaching combined with high uptake rate and low cytotoxicity. Focusing on FNDs interference w…
▽ More
Fluorescent nanodiamonds (FND) are carbon-based nanomaterials that can efficiently incorporate optically active photoluminescent centers such as the nitrogen-vacancy complex, thus making them promising candidates as optical biolabels and drug-delivery agents. FNDs exhibit bright fluorescence without photobleaching combined with high uptake rate and low cytotoxicity. Focusing on FNDs interference with neuronal function, here we examined their effect on cultured hippocampal neurons, monitoring the whole network development as well as the electrophysiological properties of single neurons. We observed that FNDs drastically decreased the frequency of inhibitory (from 1.81 Hz to 0.86 Hz) and excitatory (from 1.61 Hz to 0.68 Hz) miniature postsynaptic currents, and consistently reduced action potential (AP) firing frequency (by 36%), as measured by microelectrode arrays. On the contrary, bursts synchronization was preserved, as well as the amplitude of spontaneous inhibitory and excitatory events. Current-clamp recordings revealed that the ratio of neurons responding with AP trains of high-frequency (fast-spiking) versus neurons responding with trains of low-frequency (slow-spiking) was unaltered, suggesting that FNDs exerted a comparable action on neuronal subpopulations. At the single cell level, rapid onset of the somatic AP ("kink") was drastically reduced in FND-treated neurons, suggesting a reduced contribution of axonal and dendritic components while preserving neuronal excitability.
△ Less
Submitted 2 March, 2018;
originally announced March 2018.
-
Polarized micro-Raman studies of femtosecond laser written stress-induced optical waveguides in diamond
Authors:
B. Sotillo,
A. Chiappini,
V. Bharadwaj,
J. P. Hadden,
F. Bosia,
P. Olivero,
M. Ferrari,
R. Ramponi,
P. E. Barclay,
S. M. Eaton
Abstract:
Understanding the physical mechanisms of the refractive index modulation induced by femtosecond laser writing is crucial for tailoring the properties of the resulting optical waveguides. In this work we apply polarized Raman spectroscopy to study the origin of stress-induced waveguides in diamond, produced by femtosecond laser writing. The change in the refractive index induced by the femtosecond…
▽ More
Understanding the physical mechanisms of the refractive index modulation induced by femtosecond laser writing is crucial for tailoring the properties of the resulting optical waveguides. In this work we apply polarized Raman spectroscopy to study the origin of stress-induced waveguides in diamond, produced by femtosecond laser writing. The change in the refractive index induced by the femtosecond laser in the crystal is derived from the measured stress in the waveguides. The results help to explain the waveguide polarization sensitive guiding mechanism, as well as providing a technique for their optimization.
△ Less
Submitted 18 January, 2018; v1 submitted 24 November, 2017;
originally announced November 2017.
-
Semiconductor characterization by scanning ion beam induced charge (IBIC) microscopy
Authors:
E. Vittone,
Z. Pastuovic,
P. Olivero,
C. Manfredotti,
M. Jaksic,
A. Lo Giudice,
F. Fizzotti,
E. Colombo
Abstract:
The acronym IBIC (Ion Beam Induced Charge) was coined in early 1990's to indicate a scanning microscopy technique which uses MeV ion beams as probes to image the basic electronic properties of semiconductor materials and devices. Since then, IBIC has become a widespread analytical technique to characterize materials for electronics or for radiation detection, as testified by more than 200 papers p…
▽ More
The acronym IBIC (Ion Beam Induced Charge) was coined in early 1990's to indicate a scanning microscopy technique which uses MeV ion beams as probes to image the basic electronic properties of semiconductor materials and devices. Since then, IBIC has become a widespread analytical technique to characterize materials for electronics or for radiation detection, as testified by more than 200 papers published so far in peer-reviewed journals. Its success stems from the valuable information IBIC can provide on charge transport phenomena occurring in finished devices, not easily obtainable by other analytical techniques. However, IBIC analysis requires a robust theoretical background to correctly interpret experimental data. In order to illustrate the importance of using a rigorous mathematical formalism, we present in this paper a benchmark IBIC experiment aimed to test the validity of the interpretative model based on the Gunn's theorem and to provide an example of the analytical capability of IBIC to characterize semiconductor devices.
△ Less
Submitted 1 September, 2016;
originally announced September 2016.
-
All-carbon multi-electrode array for real-time in vitro measurements of oxidizable neurotransmitters
Authors:
F. Picollo,
A. Battiato,
E. Bernardi,
M. Plaitano,
C. Franchino,
S. Gosso,
A. Pasquarelli,
E. Carbone,
P. Olivero,
V. Carabelli
Abstract:
We report on the ion beam fabrication of all-carbon multi electrode arrays (MEAs) based on 16 graphitic micro-channels embedded in single-crystal diamond (SCD) substrates. The fabricated SCD-MEAs are systematically employed for the in vitro simultaneous amperometric detection of the secretory activity from populations of chromaffin cells, demonstrating a new sensing approach with respect to standa…
▽ More
We report on the ion beam fabrication of all-carbon multi electrode arrays (MEAs) based on 16 graphitic micro-channels embedded in single-crystal diamond (SCD) substrates. The fabricated SCD-MEAs are systematically employed for the in vitro simultaneous amperometric detection of the secretory activity from populations of chromaffin cells, demonstrating a new sensing approach with respect to standard techniques. The biochemical stability and biocompatibility of the SCD-based device combined with the parallel recording of multi-electrodes array allow: i) a significant time saving in data collection during drug screening and/or pharmacological tests over a large number of cells, ii) the possibility of comparing altered cell functionality among cell populations, and iii) the repeatition of acquisition runs over many cycles with a fully non-toxic and chemically robust bio-sensitive substrate.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
IBIC analysis of CdTe/CdS solar cells
Authors:
E. Colombo,
A. Bosio,
S. Calusi,
L. Giuntini,
A. Lo Giudice,
C. Manfredotti,
M. Massi,
P. Olivero,
A. Romeo,
N. Romeo,
E. Vittone
Abstract:
This paper reports on the investigation of the electronic properties of a thin film CdS/CdTe solar cell with the Ion Beam Induced Charge (IBIC) technique. The device under test is a thin film (total thickness around 10 um) multilayer heterojunction solar cell, displaying an efficiency of 14% under AM1.5 illumination conditions. The IBIC measurements were carried out using focused 3.150 MeV He ions…
▽ More
This paper reports on the investigation of the electronic properties of a thin film CdS/CdTe solar cell with the Ion Beam Induced Charge (IBIC) technique. The device under test is a thin film (total thickness around 10 um) multilayer heterojunction solar cell, displaying an efficiency of 14% under AM1.5 illumination conditions. The IBIC measurements were carried out using focused 3.150 MeV He ions raster scanned onto the surface of the back electrode. The charge collection efficiency (CCE) maps show inhomogeneous response of the cell to be attributed to the polycrystalline nature of the CdTe bulk material. Finally, the evolution of the IBIC signal vs. the ion fluence was studied in order to evaluate the radiation hardness of the CdS/CdTe solar cells in view of their use in solar modules for space applications.
△ Less
Submitted 26 August, 2016;
originally announced August 2016.
-
Charge collection efficiency map** of interdigitated 4H-SiC detectors
Authors:
E. Vittone,
N. Skukan,
Z. Pastuovic,
P. Olivero,
M. Jaksic
Abstract:
The Ion Beam Induced Charge Collection (IBIC) technique was used to map the charge collection efficiency (CCE) of a 4H-SiC photodetector with coplanar interdigitated Schottky barrier electrodes and a common ohmic contact on the back side. IBIC maps were obtained using focused proton beams with energies of 0.9 MeV and 1.5 MeV, at different bias voltages and different sensitive electrode configurati…
▽ More
The Ion Beam Induced Charge Collection (IBIC) technique was used to map the charge collection efficiency (CCE) of a 4H-SiC photodetector with coplanar interdigitated Schottky barrier electrodes and a common ohmic contact on the back side. IBIC maps were obtained using focused proton beams with energies of 0.9 MeV and 1.5 MeV, at different bias voltages and different sensitive electrode configurations (charge collection at the top Schottky or at the back Ohmic contact). These different experimental conditions have been modeled using a two dimensional finite element code to solve the adjoint carrier continuity equations and the results obtained have been compared with experimental results. The excellent consistency between the simulated and experimental CCE maps allows an exhaustive interpretation of the charge collection mechanisms occurring in pixellated or strip detectors.
△ Less
Submitted 26 August, 2016;
originally announced August 2016.
-
Monte Carlo analysis of a lateral IBIC experiment on a 4H-SiC Schottky diode
Authors:
P. Olivero,
J. Forneris,
P. Gamarra,
M. Jaksic,
A. Lo Giudice,
C. Manfredotti,
Z. Pastuovic,
N. Skukan,
E. Vittone
Abstract:
The transport properties of a 4H-SiC Schottky diode have been investigated by the Ion Beam Induced Charge (IBIC) technique in lateral geometry through the analysis of the charge collection efficiency (CCE) profile at a fixed applied reverse bias voltage. The cross section of the sample orthogonal to the electrodes was irradiated by a rarefied 4 MeV proton microbeam and the charge pulses have been…
▽ More
The transport properties of a 4H-SiC Schottky diode have been investigated by the Ion Beam Induced Charge (IBIC) technique in lateral geometry through the analysis of the charge collection efficiency (CCE) profile at a fixed applied reverse bias voltage. The cross section of the sample orthogonal to the electrodes was irradiated by a rarefied 4 MeV proton microbeam and the charge pulses have been recorded as function of incident proton position with a spatial resolution of 2 um. The CCE profile shows a broad plateau with CCE values close to 100% occurring at the depletion layer, whereas in the neutral region, the exponentially decreasing profile indicates the dominant role played by the diffusion transport mechanism. Map** of charge pulses was accomplished by a novel computational approach, which consists in map** the Gunn's weighting potential by solving the electrostatic problem by finite element method and hence evaluating the induced charge at the sensing electrode by a Monte Carlo method. The combination of these two computational methods enabled an exhaustive interpretation of the experimental profiles and allowed an accurate evaluation both of the electrical characteristics of the active region (e.g. electric field profiles) and of basic transport parameters (i. e. diffusion length and minority carrier lifetime).
△ Less
Submitted 29 August, 2016;
originally announced August 2016.
-
Focused ion beam fabrication and IBIC characterization of a diamond detector with buried electrodes
Authors:
P. Olivero,
J. Forneris,
M. Jaksic,
Z. Pastuovic,
F. Picollo,
N. Skukan,
E. Vittone
Abstract:
This paper reports on the fabrication and characterization of a high purity monocrystalline diamond detector with buried electrodes realized by the selective damage induced by a focused 6 MeV carbon ion beam scanned over a pattern defined at the micrometric scale. A suitable variable-thickness mask was deposited on the diamond surface in order to modulate the penetration depth of the ions and to s…
▽ More
This paper reports on the fabrication and characterization of a high purity monocrystalline diamond detector with buried electrodes realized by the selective damage induced by a focused 6 MeV carbon ion beam scanned over a pattern defined at the micrometric scale. A suitable variable-thickness mask was deposited on the diamond surface in order to modulate the penetration depth of the ions and to shallow the damage profile toward the surface. After the irradiation, the sample was annealed at high temperature in order to promote the conversion to the graphitic phase of the end-of-range regions which experienced an ion-induced damage exceeding the damage threshold, while recovering the sub-threshold damaged regions to the highly resistive diamond phase. This process provided conductive graphitic electrodes embedded in the insulating diamond matrix; the presence of the variable-thickness mask made the terminations of the channels emerging at the diamond surface and available to be connected to an external electronic circuit. In order to evaluate the quality of this novel microfabrication procedure based on direct ion writing, we performed frontal Ion Beam Induced Charge (IBIC) measurements by raster scanning focused MeV ion beams onto the diamond surface. Charge collection efficiency (CCE) maps were measured at different bias voltages. The interpretation of such maps was based on the Shockley-Ramo-Gunn formalism.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Lateral IBIC characterization of single crystal synthetic diamond detectors
Authors:
A. Lo Giudice,
P. Olivero,
C. Manfredotti,
M. Marinelli,
E. Milani,
F. Picollo,
G. Prestopino,
A. Re,
V. Rigato,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross sections using a 2 MeV proton microbeam. CCE profiles in the depth direction were extracted from the cross-sectional maps at variable bias voltage. IBIC spectra…
▽ More
In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross sections using a 2 MeV proton microbeam. CCE profiles in the depth direction were extracted from the cross-sectional maps at variable bias voltage. IBIC spectra relevant to the depletion region extending beneath the frontal Schottky electrode show a 100% CCE, with a spectral resolution of about 1.5%. The dependence of the width of the high efficiency region from applied bias voltage allows the constant residual do** concentration of the active region to be evaluated. The region where the electric field is absent shows an exponentially decreasing CCE profile, from which it is possible to estimate the diffusion length of the minority carriers by means of a drift-diffusion model.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Development and characterization of a diamond-insulated graphitic multi electrode array realized with ion beam lithography
Authors:
F. Picollo,
A. Battiato,
E. Carbone,
L. Croin,
E. Enrico,
J. Forneris,
S. Gosso,
P. Olivero,
A. Pasquarelli,
V. Carabelli
Abstract:
The detection of quantal exocytic events from neurons and neuroendocrine cells is a challenging task in neuroscience. One of the most promising platforms for the development of a new generation of biosensors is diamond, due to its biocompatibility, transparency and chemical inertness. Moreover, the electrical properties of diamond can be turned from a perfect insulator into a conductive material (…
▽ More
The detection of quantal exocytic events from neurons and neuroendocrine cells is a challenging task in neuroscience. One of the most promising platforms for the development of a new generation of biosensors is diamond, due to its biocompatibility, transparency and chemical inertness. Moreover, the electrical properties of diamond can be turned from a perfect insulator into a conductive material (resistivity Ohm cm) by exploiting the metastable nature of this allotropic form of carbon. A 16 channels MEA (Multi Electrode Array) suitable for cell culture growing has been fabricated by means of ion implantation. A focused 1.2 MeV He+ beam was scanned on a IIa single-crystal diamond sample (4.5x4.5x0.5 mm3) to cause highly damaged sub-superficial structures that were defined with micrometric spatial resolution. After implantation, the sample was annealed. This process provides the conversion of the sub-superficial highly damaged regions to a graphitic phase embedded in a highly insulating diamond matrix. Thanks to a three-dimensional masking technique, the endpoints of the sub-superficial channels emerge in contact with the sample surface, therefore being available as sensing electrodes. Cyclic voltammetry and amperometry measurements of solutions with increasing concentrations of adrenaline were performed to characterize the biosensor sensitivity. The reported results demonstrate that this new type of biosensor is suitable for in vitro detection of catecholamine release.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
IBIC characterization of an ion-beam-micromachined multi-electrode diamond detector
Authors:
J. Forneris,
V. Grilj,
M. Jaksic,
A. Lo Giudice,
P. Olivero,
F. Picollo,
N. Skukan,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
Deep Ion Beam Lithography (DIBL) has been used for the direct writing of buried graphitic regions in monocrystalline diamond with micrometric resolution. Aiming at the development and the characterization of a fully ion-beam-micromachined solid state ionization chamber, a device with interdigitated electrodes was fabricated by using a 1.8 MeV He+ ion microbeam scanning on a homoepitaxial, grown by…
▽ More
Deep Ion Beam Lithography (DIBL) has been used for the direct writing of buried graphitic regions in monocrystalline diamond with micrometric resolution. Aiming at the development and the characterization of a fully ion-beam-micromachined solid state ionization chamber, a device with interdigitated electrodes was fabricated by using a 1.8 MeV He+ ion microbeam scanning on a homoepitaxial, grown by chemical vapour deposition (CVD). In order to evaluate the ionizing-radiation-detection performance of the device, charge collection efficiency (CCE) maps were extracted from Ion Beam Induced Charge (IBIC) measurements carried out by probing different arrangements of buried microelectrodes. The analysis of the CCE maps allowed for an exhaustive evaluation of the detector features, in particular the individuation of the different role played by electrons and holes in the formation of the induced charge pulses. Finally, a comparison of the performances of the detector with buried graphitic electrodes with those relevant to conventional metallic surface electrodes evidenced the formation of a dead layer overlying the buried electrodes as a result of the fabrication process.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Evidence of light guiding in ion-implanted diamond
Authors:
S. Lagomarsino,
P. Olivero,
F. Bosia,
M. Vannoni,
S. Calusi,
L. Giuntini,
M. Massi
Abstract:
We demonstrate the feasibility of fabricating light-waveguiding microstructures in bulk single-crystal diamond by means of direct ion implantation with a scanning microbeam, resulting in the modulation of the refractive index of the ion-beam damaged crystal. Direct evidence of waveguiding through such buried microchannels is obtained with a phase-shift micro-interferometric method allowing the stu…
▽ More
We demonstrate the feasibility of fabricating light-waveguiding microstructures in bulk single-crystal diamond by means of direct ion implantation with a scanning microbeam, resulting in the modulation of the refractive index of the ion-beam damaged crystal. Direct evidence of waveguiding through such buried microchannels is obtained with a phase-shift micro-interferometric method allowing the study of the multi-modal structure of the propagating electromagnetic field. The possibility of defining optical and photonic structures by direct ion writing opens a range of new possibilities in the design of quantum-optical devices in bulk single crystal diamond.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors
Authors:
J. Forneris,
A. Lo Giudice,
P. Olivero,
F. Picollo,
A. Re,
M. Marinelli,
F. Pompili,
C. Verona,
G. Verona Rinati,
M. Benetti,
D. Cannata,
F. Di Pietrantonio
Abstract:
In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the Reactive Ion Etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the el…
▽ More
In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the Reactive Ion Etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the electrodes results in a shorter travel path for the excess charge carriers, thus contributing to a more efficient charge collection mech-anism. The CCE of the device was mapped by means of the Ion Beam Induced Charge (IBIC) technique. A 1 MeV proton micro-beam was raster scanned over the active area of the diamond detector under different bias voltage conditions, enabling to probe the charge transport properties of the detector up to a depth of 8 μm below the sample surface. The experimental results, supported by the numerical simulations, show a significant improvement in the 3D-detector performance (i.e. CCE, energy resolution, extension of the active area) if compared with the results obtained by standard surface metallic electrodes.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Microelectrode arrays of diamond-insulated graphitic channels for real time detection of exocytotic events from cultured chromaffin cells and slices of adrenal glands
Authors:
F. Picollo,
A. Battiato,
E. Bernardi,
A. Marcantoni,
A. Pasquarelli,
E. Carbone,
P. Olivero,
V. Carabelli
Abstract:
A microstructured graphitic 4x4 multielectrode array was embedded in a single crystal diamond substrate (4x4 {uG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time effective fabrication of extended arrays with reproducible elect…
▽ More
A microstructured graphitic 4x4 multielectrode array was embedded in a single crystal diamond substrate (4x4 {uG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20x3.5 um^2) separated by 200 um gaps. Taking advantage of the array geometry we addressed the following specific issues: i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, ii) resolve the waveform of different subsets of exocytotic events, iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 Hz and 0.3 Hz respectively for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated to "full fusion" events, "kiss and-run" and "kiss-and-stay" exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Electrical control of deep NV centers in diamond by means of sub-superficial graphitic micro-electrodes
Authors:
J. Forneris,
S. Ditalia Tchernij,
A. Tengattini,
E. Enrico,
V. Grilj,
N. Skukan,
G. Amato,
L. Boarino,
M. Jakšić,
P. Olivero
Abstract:
The control of the charge state of nitrogen-vacancy (NV) centers in diamond is of primary importance for the stabilization of their quantum-optical properties, in applications ranging from quantum sensing to quantum computing. To this purpose, in this work current-injecting micro-electrodes were fabricated in bulk diamond for NV charge state control. Buried (i.e. 3 μm in depth) graphitic micro-ele…
▽ More
The control of the charge state of nitrogen-vacancy (NV) centers in diamond is of primary importance for the stabilization of their quantum-optical properties, in applications ranging from quantum sensing to quantum computing. To this purpose, in this work current-injecting micro-electrodes were fabricated in bulk diamond for NV charge state control. Buried (i.e. 3 μm in depth) graphitic micro-electrodes with spacing of 9 μm were created in single-crystal diamond substrates by means of a 6 MeV C scanning micro-beam. The high breakdown field of diamond was exploited to electrically control the variation in the relative population of the negative (NV-) and neutral (NV0) charge states of sub-superficial NV centers located in the inter- electrode gap regions, without incurring into current discharges. Photoluminescence spectra acquired from the biased electrodes exhibited an electrically induced increase up to 40% in the NV- population at the expense of the NV0 charge state. The variation in the relative charge state populations showed a linear dependence from the injected current at applied biases smaller than 250 V, and was interpreted as the result of electron trap** at NV sites, consistently with the Space Charge Limited Current interpretation of the abrupt current increase observed at 300 V bias voltage. In correspondence of such trap-filling-induced transition to a high-current regime, a strong electroluminescent emission from the NV0 centers was observed. In the high-current-injection regime, a decrease in the NV- population was observed, in contrast with the results obtained at lower bias voltages. These results disclose new possibilities in the electrical control of the charge state of NV centers located in the diamond bulk, which are characterized by longer spin coherence times.
△ Less
Submitted 19 July, 2016;
originally announced July 2016.
-
Creation and characterization of He-related color centers in diamond
Authors:
Jacopo Forneris,
Andrea Tengattini,
Sviatoslav Ditalia Tchernij,
Federico Picollo,
Alfio Battiato,
Paolo Traina,
Ivo Degiovanni,
Ekaterina Moreva,
Giorgio Brida,
Veljko Grilj,
Natko Skukan,
Milko Jakšić,
Marco Genovese,
Paolo Olivero
Abstract:
Diamond is a promising material for the development of emerging applications in quantum optics, quantum information and quantum sensing. The fabrication and characterization of novel luminescent defects with suitable opto-physical properties is therefore of primary importance for further advances in these research fields. In this work we report on the investigation in the formation of photolumines…
▽ More
Diamond is a promising material for the development of emerging applications in quantum optics, quantum information and quantum sensing. The fabrication and characterization of novel luminescent defects with suitable opto-physical properties is therefore of primary importance for further advances in these research fields. In this work we report on the investigation in the formation of photoluminescent (PL) defects upon MeV He implantation in diamond. Such color centers, previously reported only in electroluminescence and cathodoluminescence regime, exhibited two sharp emission lines at 536.5 nm and 560.5 nm, without significant phonon sidebands. A strong correlation between the PL intensities of the above-mentioned emission lines and the He implantation fluence was found in the 10^15-10^17 cm^{-2} fluence range. The PL emission features were not detected in control samples, i.e. samples that were either unirradiated or irradiated with different ion species (H, C). Moreover, the PL emission lines disappeared in samples that were He-implanted above the graphitization threshold. Therefore, the PL features are attributed to optically active defects in the diamond matrix associated with He impurities. The intensity of the 536.5 nm and 560.5 nm emission lines was investigated as a function of the annealing temperature of the diamond substrate. The emission was observed upon annealing at temperatures higher than 500°C, at the expenses of the concurrently decreasing neutral-vacancy-related GR1 emission intensity. Therefore, our findings indicate that the luminescence originates from the formation of a stable lattice defect. Finally, the emission was investigated under different laser excitations wavelengths (i.e. 532 nm and 405 nm) with the purpose of gaining a preliminary insight about the position of the related levels in the energy gap of diamond.
△ Less
Submitted 4 June, 2016;
originally announced June 2016.
-
Realization of a diamond based high density multi electrode array by means of deep ion beam lithography
Authors:
Federico Picollo,
Alfio Battiato,
Ettore Bernardi,
Luca Boarino,
Emanuele Enrico,
Jacopo Forneris,
Daniele Gatto Monticone,
Paolo Olivero
Abstract:
In the present work we report about a parallel-processing ion beam fabrication technique whereby high-density sub-superficial graphitic microstructures can be created in diamond. Ion beam implantation is an effective tool for the structural modification of diamond: in particular ion-damaged diamond can be converted into graphite, therefore obtaining an electrically conductive phase embedded in an…
▽ More
In the present work we report about a parallel-processing ion beam fabrication technique whereby high-density sub-superficial graphitic microstructures can be created in diamond. Ion beam implantation is an effective tool for the structural modification of diamond: in particular ion-damaged diamond can be converted into graphite, therefore obtaining an electrically conductive phase embedded in an optically transparent and highly insulating matrix. The proposed fabrication process consists in the combination of Deep Ion Beam Lithography (DIBL) and Focused Ion Beam (FIB) milling. FIB micromachining is employed to define micro-apertures in the contact masks consisting of thin (<10 um) deposited metal layers through which ions are implanted in the sample. A prototypical single-cell biosensor was realized with the above described technique. The biosensor has 16 independent electrodes converging inside a circular area of 20 um diameter (typical neuroendocrine cells size) for the simultaneous recording of amperometric signals.
△ Less
Submitted 6 December, 2014;
originally announced December 2014.
-
Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector
Authors:
J. Forneris,
V. Grilj,
M. Jaksic,
P. Olivero,
F. Picollo,
N. Skukan,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers transport properties of the device. The resulting charge sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of…
▽ More
In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers transport properties of the device. The resulting charge sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of the device to ionizing radiation. This latter effect has recently attracted attention in commonly used detector materials, but different interpretations have been suggested, depending on the material, the geometry of the device and the nature of the ionizing radiation. In this letter, we report on the investigation in the formation of anomalous polarity pulses in a multi-electrode diamond detector with buried graphitic electrodes. In particular, we propose a purely electrostatic model based on the Shockley-Ramo-Gunn theory, providing a satisfactory description of anomalous pulses observed in charge collection efficiency maps measured by means of Ion Beam Induced Charge (IBIC) microscopy, and suitable for a general application in multi-electrode devices and detectors.
△ Less
Submitted 17 December, 2013;
originally announced December 2013.
-
A new diamond biosensor with integrated graphitic microchannels for detecting quantal exocytic events from chromaffin cells
Authors:
Federico Picollo,
Sara Gosso,
Ettore Vittone,
Alberto Pasquarelli,
Emilio Carbone,
Paolo Olivero,
Valentina Carabelli
Abstract:
The quantal release of catecholamines from neuroendocrine cells is a key mechanism which has been investigated with a broad range of materials and devices, among which carbon-based materials such as carbon fibers, diamond-like carbon, carbon nanotubes and nanocrystalline diamond. In the present work we demonstrate that a MeV-ion-microbeam lithographic technique can be successfully employed for the…
▽ More
The quantal release of catecholamines from neuroendocrine cells is a key mechanism which has been investigated with a broad range of materials and devices, among which carbon-based materials such as carbon fibers, diamond-like carbon, carbon nanotubes and nanocrystalline diamond. In the present work we demonstrate that a MeV-ion-microbeam lithographic technique can be successfully employed for the fabrication of an all-carbon miniaturized cellular bio-sensor based on graphitic micro-channels embedded in a single-crystal diamond matrix. The device was functionally characterized for the in vitro recording of quantal exocytic events from single chromaffin cells, with high sensitivity and signal-to-noise ratio, opening promising perspectives for the realization of monolithic all-carbon cellular biosensors.
△ Less
Submitted 29 August, 2013;
originally announced August 2013.
-
Spectroscopic measurement of the refractive index of ion-implanted diamond
Authors:
Alfio Battiato,
Federico Bosia,
Simone Ferrari,
Paolo Olivero,
Anna Sytchkova,
Ettore Vittone
Abstract:
We present the results of variable-angle spectroscopic ellipsometry and transmittance measurements to determine the variation of the complex refractive index of ion implanted single-crystal diamond. An increase is found in both real and imaginary parts at increasing damage densities. The index depth variation is determined in the whole wavelength range between 250 and 1690 nm. The dependence from…
▽ More
We present the results of variable-angle spectroscopic ellipsometry and transmittance measurements to determine the variation of the complex refractive index of ion implanted single-crystal diamond. An increase is found in both real and imaginary parts at increasing damage densities. The index depth variation is determined in the whole wavelength range between 250 and 1690 nm. The dependence from the vacancy density is evaluated, highlighting a deviation from linearity in the high-damage-density regime. A considerable increase (up to 5%) in the real part of the index is observed, attributed to an increase in polarizability, thus offering new microfabrication possibilities for waveguides and other photonic structures in diamond.
△ Less
Submitted 23 February, 2012;
originally announced February 2012.