Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Test beam measurement of ams H35 HV-CMOS capacitively coupled pixel sensor prototypes with high-resistivity substrate
Authors:
M. Benoit,
S. Braccini,
R. Casanova,
E. Cavallaro,
H. Chen,
K. Chen,
F. A. Di Bello,
D. Ferrere,
D. Frizzell,
T. Golling,
S. Gonzalez-Sevilla,
S. Grinstein,
G. Iacobucci,
M. Kiehn,
F. Lanni,
H. Liu,
J. Metcalfe,
L. Meng,
C. Merlassino,
A. Miucci,
D. Muenstermann,
M. Nessi,
H. Okawa,
I. Perić,
M. Rimoldi
, et al. (12 additional authors not shown)
Abstract:
In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO demonstrator, containing different diode and amplifier designs, was produced in ams H35 HV-CMOS technology using four different substrate resistivities spanning fr…
▽ More
In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO demonstrator, containing different diode and amplifier designs, was produced in ams H35 HV-CMOS technology using four different substrate resistivities spanning from $\mathrm{80}$ to $\mathrm{1000~Ω\cdot cm}$. A glueing process using a high-precision flip-chip machine was developed in order to capacitively couple the sensors to FE-I4 Readout ASIC using a thin layer of epoxy glue with good uniformity over a large surface. The resulting assemblies were measured in beam test at the Fermilab Test Beam Facilities with 120 GeV protons and CERN SPS H8 beamline using 80 GeV pions. The in-time efficiency and tracking properties measured for the different sensor types are shown to be compatible with the ATLAS ITk requirements for its pixel sensors.
△ Less
Submitted 3 December, 2018; v1 submitted 22 December, 2017;
originally announced December 2017.
-
Testbeam results of irradiated ams H18 HV-CMOS pixel sensor prototypes
Authors:
M. Benoit,
S. Braccini,
G. Casse,
H. Chen,
K. Chen,
F. A. Di Bello,
D. Ferrere,
T. Golling,
S. Gonzalez-Sevilla,
G. Iacobucci,
M. Kiehn,
F. Lanni,
H. Liu,
L. Meng,
C. Merlassino,
A. Miucci,
D. Muenstermann,
M. Nessi,
H. Okawa,
I. Peric,
M. Rimoldi,
B. Ristic,
M. Vicente Barrero Pinto,
J. Vossebeld,
M. Weber
, et al. (4 additional authors not shown)
Abstract:
HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the $4^{\mathrm{th}}$ generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the am…
▽ More
HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the $4^{\mathrm{th}}$ generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between $1\cdot 10^{14}$ and $5\cdot 10^{15}$ 1-MeV-n$_\textrm{eq}$/cm$^2$. The sensors were glued to ATLAS FE-I4 pixel readout chips and measured at the CERN SPS H8 beamline using the FE-I4 beam telescope. Results for all fluences are very encouraging with all hit efficiencies being better than 97% for bias voltages of $85\,$V. The sample irradiated to a fluence of $1\cdot 10^{15}$ n$_\textrm{eq}$/cm$^2$ - a relevant value for a large volume of the upgraded tracker - exhibited 99.7% average hit efficiency. The results give strong evidence for the radiation tolerance of HV-CMOS sensors and their suitability as sensors for the experimental HL-LHC upgrades and future large-area silicon-based tracking detectors in high-radiation environments.
△ Less
Submitted 28 November, 2017; v1 submitted 8 November, 2016;
originally announced November 2016.