-
Unveiling interatomic distances influencing the reaction coordinates in alanine dipeptide isomerization: An explainable deep learning approach
Authors:
Kazushi Okada,
Takuma Kikutsuji,
Kei-ichi Okazaki,
Toshifumi Mori,
Kang Kim,
Nobuyuki Matubayasi
Abstract:
The present work shows that the free energy landscape associated with alanine dipeptide isomerization can be effectively represented by specific interatomic distances without explicit reference to dihedral angles. Conventionally, two stable states of alanine dipeptide in vacuum, i.e., C$7_{\mathrm{eq}}$ ($β$-sheet structure) and C$7_{\mathrm{ax}}$ (left handed $α$-helix structure), have been prima…
▽ More
The present work shows that the free energy landscape associated with alanine dipeptide isomerization can be effectively represented by specific interatomic distances without explicit reference to dihedral angles. Conventionally, two stable states of alanine dipeptide in vacuum, i.e., C$7_{\mathrm{eq}}$ ($β$-sheet structure) and C$7_{\mathrm{ax}}$ (left handed $α$-helix structure), have been primarily characterized using the main chain dihedral angles, $\varphi$ (C-N-C$_α$-C) and $ψ$ (N-C$_α$-C-N). However, our recent deep learning combined with "Explainable AI" (XAI) framework has shown that the transition state can be adequately captured by a free energy landscape using $\varphi$ and $θ$ (O-C-N-C$_α$) [T. Kikutsuji, et al. J. Chem. Phys. 156, 154108 (2022)]. In perspective of extending these insights to other collective variables, a more detailed characterization of transition state is required. In this work, we employ the interatomic distances and bond angles as input variables for deep learning, rather than the conventional and more elaborate dihedral angles. Our approach utilizes deep learning to investigate whether changes in the main chain dihedral angle can be expressed in terms of interatomic distances and bond angles. Furthermore, by incorporating XAI into our predictive analysis, we quantified the importance of each input variable and succeeded in clarifying the specific interatomic distance that affects the transition state. The results indicate that constructing a free energy landscape based on using the identified interatomic distance can clearly distinguish between the two stable states and provide a comprehensive explanation for the energy barrier crossing.
△ Less
Submitted 24 April, 2024; v1 submitted 13 February, 2024;
originally announced February 2024.
-
Label-free metabolic imaging of non-alcoholic-fatty-liver-disease (NAFLD) liver by volumetric dynamic optical coherence tomography
Authors:
Pradipta Mukherjee,
Shinichi Fukuda,
Donny Lukmanto,
Toshiharu Yamashita,
Kosuke Okada,
Shuichi Makita,
Ibrahim Abd El-Sadek,
Arata Miyazawa,
Lida Zhu,
Rion Morishita,
Antonia Lichtenegger,
Tetsuro Oshika,
Yoshiaki Yasuno
Abstract:
Label-free metabolic imaging of non-alcoholic fatty liver disease (NAFLD) mouse liver is demonstrated ex vivo by dynamic optical coherence tomography (OCT). The NAFLD mouse is a methionine choline-deficient (MCD)-diet model, and two mice fed MCD diet for 1 and 2 weeks are involved in addition to a normal-diet mouse. The dynamic OCT is based on repeating raster scan and logarithmic intensity varian…
▽ More
Label-free metabolic imaging of non-alcoholic fatty liver disease (NAFLD) mouse liver is demonstrated ex vivo by dynamic optical coherence tomography (OCT). The NAFLD mouse is a methionine choline-deficient (MCD)-diet model, and two mice fed MCD diet for 1 and 2 weeks are involved in addition to a normal-diet mouse. The dynamic OCT is based on repeating raster scan and logarithmic intensity variance (LIV) analysis which enables volumetric metabolic imaging with a standard-speed (50,000 A-lines/s) OCT system. Metabolic domains associated with lipid droplet accumulation and inflammation are clearly visualized three-dimensionally. Particularly, the normal-diet liver exhibits highly metabolic vessel-like structures of peri-vascular hepatic zones. The 1-week MCD-diet liver shows ring-shaped highly metabolic structures formed with lipid droplets. The 2-week MCD-diet liver exhibits fragmented vessel-like structures associated with inflammation. These results imply that volumetric LIV imaging is useful for visualizing and assessing NAFLD abnormalities.
△ Less
Submitted 3 November, 2022; v1 submitted 18 April, 2022;
originally announced April 2022.
-
Accelerating the Averaging Rate of Atomic Ensemble Clock Stability using Atomic Phase Lock
Authors:
Nobuyasu Shiga,
Michiaki Mizuno,
Kohta Kido,
Piyaphat Phoonthong,
Kunihiro Okada
Abstract:
We experimentally demonstrated that the stability of an atomic clock improves at fastest rate $τ^{-1}$ (where $τ$ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms in a single trap (atomic phase lock). For this demonstration, we developed a simple method that repeatedly monitors the atomic phase while retaining its coherence by…
▽ More
We experimentally demonstrated that the stability of an atomic clock improves at fastest rate $τ^{-1}$ (where $τ$ is the averaging time) when the phase of a local oscillator is genuinely compared to the continuous phase of many atoms in a single trap (atomic phase lock). For this demonstration, we developed a simple method that repeatedly monitors the atomic phase while retaining its coherence by observing only a portion of the whole ion cloud. Using this new method, we measured the continuous phase over 3 measurement cycles, and thereby improved the stability scaling from $τ^{-1/2}$ to $τ^{-1}$ during the 3 measurement cycles.
%Compared with the standard method that initialize phase during each measurement cycle, the long term stability was improved by a factor of $\sqrt{n_{cp}}$ (where $n_{cp}$ is the number of continuous phase measurements).
This simple method provides a path by which atomic clocks can approach a quantum projection noise limit, even when the measurement noise is dominated by the technical noise.
△ Less
Submitted 27 June, 2014; v1 submitted 7 January, 2014;
originally announced January 2014.
-
A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph
Authors:
Y. Ito,
P. Schury,
M. Wada,
S. Naimi,
C. Smorra,
T. Sonoda,
H. Mita,
A. Takamine,
K. Okada,
A. Ozawa,
H. Wollnik
Abstract:
A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally…
▽ More
A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trap** efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.
△ Less
Submitted 2 September, 2013;
originally announced September 2013.
-
An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements
Authors:
S. Naimi,
S. Nakamura,
Y. Ito,
H. Mita,
K. Okada,
A. Ozawa,
P. Schury,
T. Sonoda,
A. Takamine,
M. Wada,
H. Wollnik
Abstract:
For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pum** system to transport ions from the ESI to a precision mass analyzer. Molecular ions…
▽ More
For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pum** system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.
△ Less
Submitted 16 December, 2012; v1 submitted 6 November, 2012;
originally announced November 2012.
-
Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei
Authors:
T. Sonoda,
M. Wada,
H. Tomita,
C. Sakamoto,
T. Takatsuka,
T. Furukawa,
H. Iimura,
Y. Ito,
T. Kubo,
Y. Matsuo,
H. Mita,
S. Naimi,
S. Nakamura,
T. Noto,
P. Schury,
T. Shinozuka,
T. Wakui,
H. Miyatake,
S. Jeong,
H. Ishiyama,
Y. X. Watanabe,
Y. Hirayama,
K. Okada,
A. Takamine
Abstract:
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pum**, in combination with a sextupole ion beam guide (SPIG), has been d…
▽ More
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pum**, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stop** high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations.
△ Less
Submitted 24 October, 2012;
originally announced October 2012.