-
ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.
-
Fast Beam Conditions Monitor BCM1F for the CMS Experiment
Authors:
A. Bell,
E. Castro,
R. Hall-Wilton,
W. Lange,
W. Lohmann,
A. Macpherson,
M. Ohlerich,
N. Rodriguez,
V. Ryjov,
R. S. Schmidt,
R. L. Stone
Abstract:
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer tim…
▽ More
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer time intervals. This paper presents the Fast Beam Conditions Monitor, BCM1F, which is designed for fast flux monitoring measuring both beam halo and collision products. BCM1F is located inside the CMS pixel detector volume close to the beam-pipe. It uses sCVD diamond sensors and radiation hard front-end electronics, along with an analog optical readout of the signals. The commissioning of the system and its successful operation during the first be ams of the LHC are described.
△ Less
Submitted 18 December, 2009; v1 submitted 12 November, 2009;
originally announced November 2009.