-
Direct positron emission imaging: ultra-fast timing enables reconstruction-free imaging
Authors:
Ryosuke Ota,
Sun Il Kwon,
Eric Berg,
Fumio Hashimoto,
Kyohei Nakajima,
Izumi Ogawa,
Yoichi Tamagawa,
Tomohide Omura,
Tomoyuki Hasegawa,
Simon R. Cherry
Abstract:
Positron emission tomography, like many other tomographic imaging modalities, relies on an image reconstruction step to produce cross-sectional images from projection data. Detection and localization of the back-to-back annihilation photons produced by positron-electron annihilation defines the trajectories of these photons, which when combined with tomographic reconstruction algorithms, permits r…
▽ More
Positron emission tomography, like many other tomographic imaging modalities, relies on an image reconstruction step to produce cross-sectional images from projection data. Detection and localization of the back-to-back annihilation photons produced by positron-electron annihilation defines the trajectories of these photons, which when combined with tomographic reconstruction algorithms, permits recovery of the distribution of positron-emitting radionuclides. Here we produce cross-sectional images directly from the detected coincident annihilation photons, without using a reconstruction algorithm. Ultra-fast radiation detectors with a resolving time averaging 32 picoseconds measured the difference in arrival time of pairs of annihilation photons, localizing the annihilation site to 4.8 mm. This is sufficient to directly generate an image without reconstruction and without the geometric and sampling constraints that normally present for tomographic imaging systems.
△ Less
Submitted 12 May, 2021;
originally announced May 2021.
-
A study on energy resolution of CANDLES detector
Authors:
B. T. Khai,
S. Ajimura,
W. M. Chan,
K. Fushimi,
R. Hazama,
H. Hiraoka,
T. Iida,
K. Kanagawa,
H. Kino,
T. Kishimoto,
T. Maeda,
K. Nakajima,
M. Nomachi,
I. Ogawa,
T. Ohata,
K. Suzuki,
Y. Takemoto,
Y. Takihira,
Y. Tamagawa,
M. Tozawa,
M. Tsuzuki,
S. Umehara,
S. Yoshida
Abstract:
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value…
▽ More
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlap** probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.
△ Less
Submitted 28 January, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca
Authors:
S. Ajimura,
W. M. Chan,
K. Ichimura,
T. Ishikawa,
K. Kanagawa,
B. T. Khai,
T. Kishimoto,
H. Kino,
T. Maeda,
K. Matsuoka,
N. Nakatani,
M. Nomachi,
M. Saka,
K. Seki,
Y. Takemoto,
Y. Takihira,
D. Tanaka,
M. Tanaka,
K. Tetsuno,
V. T. T. Trang,
M. Tsuzuki,
S. Umehara,
K. Akutagawa,
T. Batpurev,
M. Doihara
, et al. (44 additional authors not shown)
Abstract:
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal background…
▽ More
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.
△ Less
Submitted 19 April, 2021; v1 submitted 20 August, 2020;
originally announced August 2020.
-
The energy calibration system for CANDLES using (n, γ) reaction
Authors:
T. Iida,
K. Mizukoshi,
T. Ohata,
T. Uehara,
T. Batpurev,
W. M. Chan,
K. Fushimi,
R. Hazama,
M. Ishikawa,
H. Kakubata,
K. Kanagawa,
S. Katagiri,
B. T. Khai,
T. Kishimoto,
X. Li,
T. Maeda,
K. Matsuoka,
K. Morishita,
M. Moser,
K. Nakajima,
M. Nomachi,
I. Ogawa,
M. Shokati,
K. Suzuki,
Y. Takemoto
, et al. (6 additional authors not shown)
Abstract:
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of…
▽ More
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
Pulse-shape discrimination potential of new scintillator material: La-GPS:Ce
Authors:
Keita Mizukoshi,
Takashi Iida,
Izumi Ogawa,
Kensei Shimizu,
Shunsuke Kurosawa,
Kei Kamada,
Masao Yoshino,
Akira Yoshikawa
Abstract:
(Gd,La)$_2$Si$_2$O$_7$:Ce (La-GPS:Ce) is a new scintillator material with high light output, high energy resolution, and fast decay time. Moreover, the scintillator has a good light output even at high temperature (up to 150$^\circ$C) and is non-hygroscopic in nature; thus, it is especially suitable for underground resource exploration. Particle identification greatly expands the possible applicat…
▽ More
(Gd,La)$_2$Si$_2$O$_7$:Ce (La-GPS:Ce) is a new scintillator material with high light output, high energy resolution, and fast decay time. Moreover, the scintillator has a good light output even at high temperature (up to 150$^\circ$C) and is non-hygroscopic in nature; thus, it is especially suitable for underground resource exploration. Particle identification greatly expands the possible applications of scintillator. For resource exploration, the particle identification should be completed in a single pulse only. The pulse-shape discrimination of the scintillator was confirmed. We compared two methods; a double gate method and a digital filter method. Using digital filter method (shape indicator), F-measure to evaluate a separation between $α$ and $γ$ particles was obtained to be 0.92 at 0.66 MeVee.
△ Less
Submitted 11 June, 2019; v1 submitted 7 April, 2019;
originally announced April 2019.
-
Background Studies for the MINER Coherent Neutrino Scattering Reactor Experiment
Authors:
MINER Collaboration,
G. Agnolet,
W. Baker,
D. Barker,
R. Beck,
T. J. Carroll,
J. Cesar,
P. Cushman,
J. B. Dent,
S. De Rijck,
B. Dutta,
W. Flanagan,
M. Fritts,
Y. Gao,
H. R. Harris,
C. C. Hays,
V. Iyer,
A. Jastram,
F. Kadribasic,
A. Kennedy,
A. Kubik,
I. Ogawa,
K. Lang,
R. Mahapatra,
V. Mandic
, et al. (25 additional authors not shown)
Abstract:
The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering proce…
▽ More
The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering process and the proposed experimental proximity to the reactor, as many as 5 to 20 events/kg/day are expected. We discuss the status of preliminary measurements to characterize the main backgrounds for the proposed experiment. Both in situ measurements at the experimental site and simulations using the MCNP and GEANT4 codes are described. A strategy for monitoring backgrounds during data taking is briefly discussed.
△ Less
Submitted 7 September, 2016;
originally announced September 2016.
-
First Millimeter-wave Spectroscopy of the Ground-state Positronium
Authors:
A. Miyazaki,
T. Yamazaki,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
Y. Tatematsu,
I. Ogawa,
T. Idehara
Abstract:
We report on the first measurement of the Breit-Wigner resonance of the transition from {\it ortho-}positronium to {\it para-}positronium. We have developed an optical system to accumulate a power of over 20 kW using a frequency-tunable gyrotron and a Fabry-Pérot cavity. This system opens a new era of millimeter-wave spectroscopy, and enables us to directly determine both the hyperfine interval an…
▽ More
We report on the first measurement of the Breit-Wigner resonance of the transition from {\it ortho-}positronium to {\it para-}positronium. We have developed an optical system to accumulate a power of over 20 kW using a frequency-tunable gyrotron and a Fabry-Pérot cavity. This system opens a new era of millimeter-wave spectroscopy, and enables us to directly determine both the hyperfine interval and the decay width of {\it p-}Ps.
△ Less
Submitted 17 December, 2014; v1 submitted 2 March, 2014;
originally announced March 2014.
-
Direct Observation of the Hyperfine Transition of the Ground State Positronium
Authors:
T. Yamazaki,
A. Miyazaki,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
I. Ogawa,
T. Idehara,
S. Sabchevski
Abstract:
We report the first direct measurement of the hyperfine transition of the ground state positronium. The hyperfine structure between ortho-positronium and para-positronium is about 203 GHz. We develop a new optical system to accumulate about 10 kW power using a gyrotron, a mode converter, and a Fabry-Pérot cavity. The hyperfine transition has been observed with a significance of 5.4 standard deviat…
▽ More
We report the first direct measurement of the hyperfine transition of the ground state positronium. The hyperfine structure between ortho-positronium and para-positronium is about 203 GHz. We develop a new optical system to accumulate about 10 kW power using a gyrotron, a mode converter, and a Fabry-Pérot cavity. The hyperfine transition has been observed with a significance of 5.4 standard deviations. The transition probability is measured to be $A = 3.1^{+1.6}_{-1.2} \times 10^{-8}$ s$^{-1}$ for the first time, which is in good agreement with the theoretical value of $3.37 \times 10^{-8}$ s$^{-1}$.
△ Less
Submitted 16 May, 2012; v1 submitted 5 April, 2012;
originally announced April 2012.
-
First direct measurement of positronium hyperfine splitting with sub-THz light
Authors:
T. Yamazaki,
A. Miyazaki,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
Y. Urushizaki,
I. Ogawa,
T. Idehara,
S. Sabchevski
Abstract:
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS, about 203 GHz) is an important observable but all previous measurements of Ps-HFS had been measured indirectly using Zeeman splitting. There might be the unknown systematic errors on the uniformity of magnetic field. We are trying to measure Ps-HFS directly using sub-THz radiatio…
▽ More
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS, about 203 GHz) is an important observable but all previous measurements of Ps-HFS had been measured indirectly using Zeeman splitting. There might be the unknown systematic errors on the uniformity of magnetic field. We are trying to measure Ps-HFS directly using sub-THz radiation. We developed an optical system to accumulate high power (about 10 kW) radiation in a Fabry-Pérot resonant cavity and observed the positronium hyperfine transition for the first time.
△ Less
Submitted 22 May, 2011;
originally announced May 2011.
-
Detection of the Direct Hyperfine Transition of Positronium Atoms using sub-THz High-power Radiation
Authors:
T. Suehara,
A. Miyazaki,
T. Yamazaki,
G. Akimoto,
A. Ishida,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
M. Yoshida,
T. Idehara,
I. Ogawa,
Y. Urushizaki,
S. Sabchevski
Abstract:
Hyperfine splitting of positronium is an important parameter for particle physics. This paper gives experimental techniques and results of R&D studies of our experiment to observe direct hyperfine transition of ortho-positronium to para-positronium.
Hyperfine splitting of positronium is an important parameter for particle physics. This paper gives experimental techniques and results of R&D studies of our experiment to observe direct hyperfine transition of ortho-positronium to para-positronium.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
Probing the Energy Structure of Positronium with a 203 GHz Fabry-Perot Cavity
Authors:
T Suehara,
A Miyazaki,
A Ishida,
T Namba,
S Asai,
T Kobayashi,
H Saito,
M Yoshida,
T Idehara,
I Ogawa,
S Kobayashi,
Y Urushizaki,
S Sabchevski
Abstract:
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS: about 203 GHz) is sensitive to new physics beyond the Standard Model via a vacuum oscillation between an ortho-Ps and a virtual photon. Previous experimental results of the Ps-HFS show 3.9 sigma(15 ppm) discrepancy from the QED calculation. All previous experiments used an indire…
▽ More
Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS: about 203 GHz) is sensitive to new physics beyond the Standard Model via a vacuum oscillation between an ortho-Ps and a virtual photon. Previous experimental results of the Ps-HFS show 3.9 sigma(15 ppm) discrepancy from the QED calculation. All previous experiments used an indirect method with static magnetic field to cause Zeeman splitting (a few GHz) between triplet states of ortho-Ps, from which the HFS value was derived. One possible systematic error source of the indirect method is the static magnetic field. We are develo** a new direct measurement system of the Ps-HFS without static magnetic field. In this measurement we use a gyrotron, a novel sub-THz light source, with a high-Finesse Fabry-Perot cavity to obtain enough radiation power at 203 GHz. The present status of the optimization studies and current design of the experiment are described.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
Precise measurement of Hyper Fine Structure of positronium using sub-THz light
Authors:
S. Asai,
T. Suehara,
T. Yamazaki,
G. Akimoto,
A. Miyazaki,
T. Namba,
T. Kobayashi,
H. Saito,
T. Idehara,
I. Ogawa,
Y. Urishizaki,
S. Sabchevski
Abstract:
Positronium is an ideal system for the research of the QED, especially for the QED in bound state. The discrepancy of 3.9σis found recently between the measured HFS values and the QED prediction ($O(α^3)$). It might be due to the contribution of the unknown new physics or the systematic problems in the previous all measurements. We propose new method to measure HFS precisely and directly. A gyrotr…
▽ More
Positronium is an ideal system for the research of the QED, especially for the QED in bound state. The discrepancy of 3.9σis found recently between the measured HFS values and the QED prediction ($O(α^3)$). It might be due to the contribution of the unknown new physics or the systematic problems in the previous all measurements. We propose new method to measure HFS precisely and directly. A gyrotron, a novel sub-THz light source is used with a high-finesse Fabry-Pérot cavity to obtain enough radiation power at 203 GHz. The present status of the optimization studies and current design of the experiment are described.
△ Less
Submitted 15 April, 2010; v1 submitted 22 March, 2010;
originally announced March 2010.
-
Precise measurement of HFS of positronium
Authors:
A. Ishida,
G. Akimoto,
K. Kato,
T. Suehara,
T. Namba,
S. Asai,
T. Kobayashi,
H. Saito,
M. Yoshida,
K. Tanaka,
A. Yamamoto,
I. Ogawa,
S. Kobayashi,
T. Idehara
Abstract:
The ground state hyperfine splitting in positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $O(α^3)$ has revealed a $3.9 σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an expe…
▽ More
The ground state hyperfine splitting in positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $O(α^3)$ has revealed a $3.9 σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an experiment to measure $Δ_{\mathrm{HFS}}$ employing new methods designed to remedy the systematic errors which may have affected the previous experiments. Our experiment will provide an independent check of the discrepancy. The measurement is in progress and a preliminary result of $Δ_{\mathrm{HFS}} = 203.399 \pm 0.029 \mathrm{GHz} (143 \mathrm{ppm})$ has been obtained. A measurement with a precision of O(1) ppm is expected within a few years.
△ Less
Submitted 22 December, 2009;
originally announced December 2009.
-
Plasma scattering measurement using a submillimeter wave gyrotron as a radiation source
Authors:
Isamu Ogawa,
Toshitaka Idehara,
Yutaka Itakura,
Masahiko Myodo,
Toshihiro Hori,
Takaki Hatae
Abstract:
Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the intensity of a probe beam. A well-collimated, submillimeter wave beam is suitable for improving the spatial and wave number resolutions. Application of high f…
▽ More
Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the intensity of a probe beam. A well-collimated, submillimeter wave beam is suitable for improving the spatial and wave number resolutions. Application of high frequency gyrotron is effective in improving the S/N ratio of the measurement because of its capacity to deliver high power. Unlike the molecular vapor lasers, the gyrotrons generate diverging beam of radiation with TEmn mode structure. It is therefore necessary to convert the output radiation into a Gaussian beam. A quasi-optical antenna is a suitable element for the conversion system under consideration since it is applicable to several TE0n and TE1n modes. In order to apply the gyrotron to plasma scattering measurement, we have stabilized the output (P=110W, f=354GHz) of gyrotron up to the level (DP/P<1 %, Df<10 kHz). The gyrotron output can be stabilized by decreasing the fluctuation of the cathode potential.
△ Less
Submitted 25 November, 2004; v1 submitted 19 November, 2004;
originally announced November 2004.
-
Development of submillimeter wave source Gyrotron FU series for plasma diagnostics
Authors:
Toshitaka Idehara,
Isamu Ogawa,
Seitaro Mitsudo,
Masaki Kamada,
Osamu Watanabe,
La Agusu
Abstract:
Our gyrotrons developed in Fukui University, Research Center for Development of Far Infrared Region (FIR FU) are high frequency, medium power gyrotrons as millimeter to submillimeter wave radiation sources for application to new far-infrared technologies including plasma diagnostics. We have already developed Gyrotron FU Series which consists of 8 gyrotrons. The gyrotron series has achieved freq…
▽ More
Our gyrotrons developed in Fukui University, Research Center for Development of Far Infrared Region (FIR FU) are high frequency, medium power gyrotrons as millimeter to submillimeter wave radiation sources for application to new far-infrared technologies including plasma diagnostics. We have already developed Gyrotron FU Series which consists of 8 gyrotrons. The gyrotron series has achieved frequency tuneability in wide range (from 38 GHz to 889 GHz). The highest frequency is corresponding to a wavelength of 337 micrometers. This is a current record for high frequency operation of gyrotron. Recently, we have developed a high harmonic gyrotron with an axis-encircling electron beam and a THz gyrotron with a pulse magnet. In this presentation, the present status of Gyrotron FU Series is described.
△ Less
Submitted 18 November, 2004;
originally announced November 2004.
-
Manipulating ionization path in a Stark map: Stringent schemes for the selective field ionization in highly excited Rb Rydberg atoms
Authors:
M. Tada,
Y. Kishimoto,
M. Shibata,
K. Kominato,
S. Yamada,
T. Haseyama,
I. Ogawa,
H. Funahashi,
K. Yamamoto,
S. Matsuki
Abstract:
We have developed a quite stringent method in selectivity to ionize the low angular- momentum ($\ell$) states which lie below and above the adjacent manifold in highly excited Rb Rydberg atoms. The method fully exploits the pulsed field-ionization characteristics of the manifold states in high slew-rate regime: Specifically the low $\ell$ state below (above) the adjacent manifold is firstly tran…
▽ More
We have developed a quite stringent method in selectivity to ionize the low angular- momentum ($\ell$) states which lie below and above the adjacent manifold in highly excited Rb Rydberg atoms. The method fully exploits the pulsed field-ionization characteristics of the manifold states in high slew-rate regime: Specifically the low $\ell$ state below (above) the adjacent manifold is firstly transferred to the lowest (highest) state in the manifold via the adiabatic transition at the first avoided crossing in low slew-rate regime, and then the atoms are driven to a high electric field for ionization in high slew-rate regime. These extreme states of the manifold are ionized at quite different fields due to the tunneling process, resulting in thus the stringent selectivity. Two manipulation schemes to realize this method actually are demonstrated here experimentally.
△ Less
Submitted 17 April, 2002;
originally announced April 2002.
-
Systematic observation of tunneling field-ionization in highly excited Rb Rydberg atoms
Authors:
Y. Kishimoto,
M. Tada,
K. Kominato,
M. Shibata,
S. Yamada,
T. Haseyama,
I. Ogawa,
H. Funahashi,
K. Yamamoto,
S. Matsuki
Abstract:
Pulsed field ionization of high-$n$ (90 $\leq n \leq$ 150) manifold states in Rb Rydberg atoms has been investigated in high slew-rate regime. Two peaks in the field ionization spectra were systematically observed for the investigated $n$ region, where the field values at the lower peak do not almost depend on the excitation energy in the manifold, while those at the higher peak increase with in…
▽ More
Pulsed field ionization of high-$n$ (90 $\leq n \leq$ 150) manifold states in Rb Rydberg atoms has been investigated in high slew-rate regime. Two peaks in the field ionization spectra were systematically observed for the investigated $n$ region, where the field values at the lower peak do not almost depend on the excitation energy in the manifold, while those at the higher peak increase with increasing excitation energy. The fraction of the higher peak component to the total ionization signals increases with increasing $n$, exceeding 80% at $n$ = 147. Characteristic behavior of the peak component and the comparison with theoretical predictions indicate that the higher peak component is due to the tunneling process. The obtained results show for the first time that the tunneling process plays increasingly the dominant role at such highly excited nonhydrogenic Rydberg atoms.
△ Less
Submitted 15 April, 2002;
originally announced April 2002.
-
A coupled microwave-cavity system in the Rydberg-atom cavity detector for dark matter axions
Authors:
M. Tada,
Y. Kishimoto,
M. Shibata,
K. Kominato,
I. Ogawa,
H. Funahashi,
K. Yamamoto,
S. Matsuki
Abstract:
A coupled microwave-cavity system of cylindrical TM$_{010}$ single-mode has been developed to search for dark matter axions around 10 $μ{\rm eV}$(2.4 GHz) with the Rydberg-atom cavity detector at 10 mK range temperature. One component of the coupled cavity (conversion cavity) made of oxygen-free high-conductivity copper is used to convert an axion into a single photon with the Primakoff process…
▽ More
A coupled microwave-cavity system of cylindrical TM$_{010}$ single-mode has been developed to search for dark matter axions around 10 $μ{\rm eV}$(2.4 GHz) with the Rydberg-atom cavity detector at 10 mK range temperature. One component of the coupled cavity (conversion cavity) made of oxygen-free high-conductivity copper is used to convert an axion into a single photon with the Primakoff process in the strong magnetic field, while the other component (detection cavity) made of Nb is utilized to detect the converted photons with Rydberg atoms passed through it without magnetic field.
Top of the detection cavity is attached to the bottom flange of the mixing chamber of a dilution refrigerator, thus the whole cavity is cooled down to 10 mK range to reduce the background thermal blackbody-photons in the cavity.
The cavity resonant frequency is tunable over $\sim$ 15% by moving dielectric rods inserted independently into each part of the cavities along the cylindrical axis. In order to reduce the heat load from the higher temperature side to the most cooled dilution refrigerator part, the tuning rod at the conversion cavity is especially driven via the Kevlar strings with a step** motor outside the cryostat at room temperature.
The lowest temperature achieved up to now is 12 $\sim$ 15 mK for the long period operation and the loaded Q value at low temperature is 3.5 $\sim$ 4.5 $\times$ $10^4$ for the whole range of frequency tuning. Characteristics and the performance of the coupled-cavity system are presented and discussed with possible future improvements.
△ Less
Submitted 4 January, 2001;
originally announced January 2001.
-
Coherent time evolution of highly excited Rydberg states in pulsed electric field: Opening a stringent way to selectively field-ionize the highly excited states
Authors:
M. Tada,
Y. Kishimoto,
I. Ogawa,
H. Funahashi,
K. Yamamoto,
S. Matsuki
Abstract:
Coherent time evolution of highly excited Rydberg states in Rb (98 < n < 150) under pulsed electric field in high slew-rate regime was investigated with the field ionization detection. The electric field necessary to ionize the Rydberg states was found to take discrete values successively depending on the slew rate. Specifically the slew-rate dependence of the ionization field varies with the qu…
▽ More
Coherent time evolution of highly excited Rydberg states in Rb (98 < n < 150) under pulsed electric field in high slew-rate regime was investigated with the field ionization detection. The electric field necessary to ionize the Rydberg states was found to take discrete values successively depending on the slew rate. Specifically the slew-rate dependence of the ionization field varies with the quantum defect value of the states, i.e. with the energy position of the states relative to the adjacent manifold. This discrete transitional behavior of the ionization field observed for the first time is considered to be a manifestation of the strong coherence effect in the time evolution of the Rydberg states in pulsed electric field and opens a new effective way to stringently select a low-l state from the nearby states by field ionization.
△ Less
Submitted 28 October, 2000; v1 submitted 27 October, 2000;
originally announced October 2000.