-
YAP:Ce scintillator as an absolute ultracold neutron detector
Authors:
M. Krivoš,
Z. Tang,
N. Floyd,
C. L. Morris,
M. Blatnik,
C. Cude-Woods,
S. M. Clayton,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
I. F. Martinez,
A. S. C. Navazo,
C. M. O'Shaughnessy,
E. L. Renner,
R. W. Pattie,
A. R. Young
Abstract:
The upcoming UCNProBe experiment at Los Alamos National Laboratory will measure the $β$-decay rate of free neutrons with different systematic uncertainties than previous beam-based neutron lifetime experiments. We have developed a new $^{10}$B-coated YAP:Ce scintillator whose properties are presented. The advantage of the YAP:Ce scintillator is its high Fermi potential, which reduces the probabili…
▽ More
The upcoming UCNProBe experiment at Los Alamos National Laboratory will measure the $β$-decay rate of free neutrons with different systematic uncertainties than previous beam-based neutron lifetime experiments. We have developed a new $^{10}$B-coated YAP:Ce scintillator whose properties are presented. The advantage of the YAP:Ce scintillator is its high Fermi potential, which reduces the probability for upscattering of ultracold neutrons, and its short decay time, which is important at high counting rates. Birks' coefficient of YAP:Ce was measured to be ($5.56^{+0.05}_{-0.30})\times 10^{-4}$ cm/MeV and light losses due to 120 nm of $^{10}$B-coating to be about 60%. The loss of light from YAP:Ce due to transmission through deuterated polystyrene scintillator was about 50%. The efficiency for counting neutrons that are captured on the $^{10}$B coating is (86.82 $\pm$ 2.61)%. Measurement with ultracold neutrons showed that YAP:Ce crystal counted 8% to 28% more UCNs compared to ZnS screen. This may be due to an uneven coating of $^{10}$B on the rough surface.
△ Less
Submitted 27 March, 2024;
originally announced May 2024.
-
Scintillation characteristics of the EJ-299-02H scintillator
Authors:
N. Floyd,
Md. T. Hassan,
Z. Tang,
M. Krivos,
M. Blatnik,
S. M. Clayton,
C. Cude-Woods,
A. T. Holley,
T. M. Ito,
B. A. Johnson,
C. -Y. Liu,
M. Makela,
C. L. Morris,
A. S. C. Navazo,
C. M. O'Shaughnessy,
E. L. Renner,
R. W. Pattie,
A. R. Young
Abstract:
A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer, and the relative light outputs from the decay of $^{241}$Am and Compton scattering of electrons were used to extract the quenching parameter. With these characteristics of…
▽ More
A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer, and the relative light outputs from the decay of $^{241}$Am and Compton scattering of electrons were used to extract the quenching parameter. With these characteristics of the material known, the light yield of the scintillator can be calculated. The ability to make these scintillators deuterated, accompanied by its relatively thin dead layer, make it ideal for use in UCN experiment, where the light yield of decay electrons and alphas from neutron capture are critical for counting events.
△ Less
Submitted 27 March, 2024; v1 submitted 29 September, 2023;
originally announced October 2023.
-
Demonstration of Sub-micron UCN Position Resolution using Room-temperature CMOS Sensor
Authors:
S. Lin,
J. K. Baldwin,
M. Blatnik,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
B. Filippone,
E. M. Fries,
P. Geltenbort,
A. T. Holley,
W. Li,
C. Y. Liu,
M. Makela,
C. L. Morris,
R. Musedinovic,
C. O'Shaughnessy,
R. W. Pattie,
D. J. Salvat,
A. Saunders,
E. I. Sharapov,
M. Singh,
X. Sun,
Z. Tang,
W. Uhrich,
W. Wei
, et al. (3 additional authors not shown)
Abstract:
High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics-informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-tempera…
▽ More
High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics-informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work [1, 2] that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully-connected neural network (FCNN) to learn a map** from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.
△ Less
Submitted 16 May, 2023;
originally announced May 2023.
-
Design of the ECCE Detector for the Electron Ion Collider
Authors:
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin,
R. Capobianco
, et al. (259 additional authors not shown)
Abstract:
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent track…
▽ More
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. This detector concept has been selected to be the basis for the EIC project detector.
△ Less
Submitted 11 May, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Characterization of the new Ultracold Neutron beamline at the LANL UCN facility
Authors:
D. K. -T. Wong,
M. T. Hassan,
J. F. Burdine,
T. E. Chupp,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
T. M. Ito,
C. -Y. Liu,
M. Makela,
C. L. Morris,
C. M. O'Shaughnessy,
A. Reid,
N. Sachdeva,
W. Uhrich
Abstract:
The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey's method of separated oscillatory fields to search for a nEDM. In this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate…
▽ More
The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey's method of separated oscillatory fields to search for a nEDM. In this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate a sufficient number of stored polarized UCN to achieve a statistical uncertainty of $δd_n = 2\times 10^{-27}$~$e\cdot\text{cm}$ in 5 calendar years of running. We also present an analytical model describing data that provides a simple parameterization of the input UCN energy spectrum on the new beamline.
△ Less
Submitted 17 January, 2023; v1 submitted 30 August, 2022;
originally announced September 2022.
-
Detector Requirements and Simulation Results for the EIC Exclusive, Diffractive and Tagging Physics Program using the ECCE Detector Concept
Authors:
A. Bylinkin,
C. T. Dean,
S. Fegan,
D. Gangadharan,
K. Gates,
S. J. D. Kay,
I. Korover,
W. B. Li,
X. Li,
R. Montgomery,
D. Nguyen,
G. Penman,
J. R. Pybus,
N. Santiesteban,
R. Trotta,
A. Usman,
M. D. Baker,
J. Frantz,
D. I. Glazier,
D. W. Higinbotham,
T. Horn,
J. Huang,
G. Huber,
R. Reed,
J. Roche
, et al. (258 additional authors not shown)
Abstract:
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fr…
▽ More
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirmed the proposed technology and design satisfy the requirements. The projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb^-1 of integrated luminosity. Additionally, a few insights on the potential 2nd Interaction Region can (IR) were also documented which could serve as a guidepost for the future development of a second EIC detector.
△ Less
Submitted 6 March, 2023; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will…
▽ More
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will be presented. The ECCE detector has enabled precise EIC heavy flavor hadron and jet measurements with a broad kinematic coverage. These proposed heavy flavor measurements will help systematically study the hadronization process in vacuum and nuclear medium especially in the underexplored kinematic region.
△ Less
Submitted 23 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Exclusive J/$ψ$ Detection and Physics with ECCE
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the…
▽ More
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the spatial distribution of gluons in the nucleus. Recently the problem of the origin of hadron mass has received lots of attention in determining the anomaly contribution $M_{a}$. The trace anomaly is sensitive to the gluon condensate, and exclusive production of quarkonia such as J/$ψ$ and $Υ$ can serve as a sensitive probe to constrain it. In this paper, we present the performance of the ECCE detector for exclusive J/$ψ$ detection and the capability of this process to investigate the above physics opportunities with ECCE.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
AI-assisted Optimization of the ECCE Tracking System at the Electron Ion Collider
Authors:
C. Fanelli,
Z. Papandreou,
K. Suresh,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann
, et al. (258 additional authors not shown)
Abstract:
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to…
▽ More
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.
△ Less
Submitted 19 May, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Scientific Computing Plan for the ECCE Detector at the Electron Ion Collider
Authors:
J. C. Bernauer,
C. T. Dean,
C. Fanelli,
J. Huang,
K. Kauder,
D. Lawrence,
J. D. Osborn,
C. Paus,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (256 additional authors not shown)
Abstract:
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing thes…
▽ More
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. In this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.
△ Less
Submitted 17 May, 2022;
originally announced May 2022.
-
Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap
Authors:
C. Cude-Woods,
F. M. Gonzalez,
E. M. Fries,
T. Bailey,
M. Blatnik,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
S. A. Currie,
M. Dawid,
B. W. Filippone,
W. Fox,
P. Geltenbort,
E. George,
L. Hayen,
K. P. Hickerson,
M. A. Hoffbauer,
K. Hoffman,
A. T. Holley,
T. M. Ito,
A. Komives,
C. -Y. Liu,
M. Makela,
C. L. Morris,
R. Musedinovic
, et al. (17 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for inve…
▽ More
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.
△ Less
Submitted 4 May, 2022;
originally announced May 2022.
-
Ultracold Neutron Properties of the Eljen-299-02D deuterated scintillator
Authors:
Z. Tang,
E. B. Watkins,
S. M. Clayton,
S. A. Currie,
D. E. Fellers,
Md. T. Hassan,
D. E. Hooks,
T. M. Ito,
S. K. Lawrence,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
L. P. Neukirch,
A. Saunders,
C. M. O'Shaughnessy,
C. Cude-Woods,
J. H. Choi,
A. R. Young,
B. A. Zeck,
F. Gonzalez,
C. Y. Liu,
N. C. Floyd,
K. P. Hickerson,
A. T. Holley,
B. A. Johnson
, et al. (2 additional authors not shown)
Abstract:
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
△ Less
Submitted 25 September, 2020;
originally announced September 2020.
-
Effect of an electric field on liquid helium scintillation produced by fast electrons
Authors:
N. S. Phan,
V. Cianciolo,
S. M. Clayton,
S. A. Currie,
R. Dipert,
T. M. Ito,
S. W. T. MacDonald,
C. M. O'Shaughnessy,
J. C. Ramsey,
G. M. Seidel,
E. Smith,
E. Tang,
Z. Tang,
W. Yao
Abstract:
The dependence on applied electric field ($0 - 40$ kV/cm) of the scintillation light produced by fast electrons and $α$ particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution…
▽ More
The dependence on applied electric field ($0 - 40$ kV/cm) of the scintillation light produced by fast electrons and $α$ particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations, and has a dependence on the energy of the primary ionization electron. We discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.
△ Less
Submitted 14 September, 2020; v1 submitted 6 May, 2020;
originally announced May 2020.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
Authors:
K. Kuk,
C. Cude-Woods,
C. R. Chavez,
J. H. Choi,
J. Estrada,
M. Hoffbauer,
M. Makela,
P. Merkel,
C. L. Morris,
E. Ramberg,
Z. Wang,
T. Bailey,
M. Blatnik,
E. R. Adamek,
L. J. Broussard,
M. A. -P. Brown,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
X. Ding,
D. Dinger,
B. Filippone,
E. M. Fries,
P. Geltenbort,
E. George
, et al. (26 additional authors not shown)
Abstract:
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolutio…
▽ More
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.
△ Less
Submitted 28 February, 2019;
originally announced March 2019.
-
Recent Results from the Majorana Demonstrator
Authors:
T Gilliss,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green,
J Gruszko,
I S Guinn
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility i…
▽ More
The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the $0νββ$ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale $^{76}$Ge $0νββ$ LEGEND experiment.
△ Less
Submitted 4 April, 2018;
originally announced April 2018.
-
First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as $e$/1000 with the \textsc{Majorana Demonstrator}
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges…
▽ More
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges less than $e$ are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the \textsc{Majorana Demonstrator} by searching for multiple- detector events with individual-detector energy depositions down to 1 keV. This search is background free and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as $e$/1000.
△ Less
Submitted 29 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Low Background Materials and Fabrication Techniques for Cables and Connectors in the Majorana Demonstrator
Authors:
M. Busch,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the MAJORANA DEMONSTRATOR, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Design improvements to cables and connectors in the Majorana Demonstrator
Authors:
C. R. Haufe,
A. L. Reine,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (46 additional authors not shown)
Abstract:
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Researc…
▽ More
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.
△ Less
Submitted 9 December, 2017;
originally announced December 2017.
-
Initial Results from the Majorana Demonstrator
Authors:
T. S. Caldwell,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (47 additional authors not shown)
Abstract:
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point con…
▽ More
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the full detector array has been acquiring data since August 2016. We will discuss the status of the MAJORANA DEMONSTRATOR and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the DEMONSTRATOR, and implications for a ton-scale Ge-based neutrinoless double-beta decay search.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Data quality assurance for the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility i…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. The various techniques employed to ensure the integrity of the measured spectra are discussed. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Contamination Control and Assay Results for the Majorana Demonstrator Ultra Clean Components
Authors:
C. D. Christofferson,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operatin…
▽ More
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Progress Toward A $2νββ$ Measurement For The Majorana Demonstrator
Authors:
T Gilliss,
N Abgrall,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
A W Bradley,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode (…
▽ More
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode ($2νββ$) of $^{76}$Ge. For Ge detectors, having superior energy resolution (0.1%), this mode poses negligible background to the $0νββ$ mode, even for a ton-scale experiment. However, the measurement of the $2νββ$ mode allows for careful systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts related to both the $0νββ$ and $2νββ$ decay modes. A precision measurement of the $2νββ$ shape also allows searches for spectral distortions, possibly indicative of new physics, including $0νββχ$. Work is underway to construct a full experimental background model enabling a Bayesian fit to the measured energy spectrum and extraction of a precise $2νββ$ spectrum and half-life.
△ Less
Submitted 20 November, 2017; v1 submitted 15 November, 2017;
originally announced November 2017.
-
Spectral analysis for the Majorana Demonstrator experiment
Authors:
L. Hehn,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}\textrm{Ge}$-enriched germanium detectors totaling 44.1 kg (29.7 kg enriched detectors), located at the 4850' level of the Sanf…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}\textrm{Ge}$-enriched germanium detectors totaling 44.1 kg (29.7 kg enriched detectors), located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data taken with this setup since summer 2015 at different construction stages of the experiment show a clear reduction of the observed background index around the ROI for $0νββ$-decay search due to improvements in shielding. We discuss the statistical approaches to search for a $0νββ$-signal and derive the physics sensitivity for an expected exposure of $10\,\textrm{kg}{\cdot}\textrm{y}$ from enriched detectors using a profile likelihood based hypothesis test in combination with toy Monte Carlo data.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator
Authors:
C. E. Aalseth,
N. Abgrall,
E. Aguayo,
S. I. Alvis,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
M. Boswell,
R. L. Brodzinski,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson
, et al. (104 additional authors not shown)
Abstract:
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construct…
▽ More
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr (90\% CL). This result constrains the effective Majorana neutrino mass to below 240 to 520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$ counts/(FWHM t yr).
△ Less
Submitted 26 March, 2018; v1 submitted 31 October, 2017;
originally announced October 2017.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
The Status and Initial Results of the MAJORANA DEMONSTRATOR Experiment
Authors:
V. E. Guiseppe,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (45 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in Ge-76) of Ge de…
▽ More
Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in Ge-76) of Ge detectors divided between two modules contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota, USA. The initial goals of the DEMONSTRATOR are to establish the required background and scalability of a Ge-based next-generation ton-scale experiment. Following a commissioning run that started in 2015, the first detector module started low-background data production in early 2016. The second detector module was added in August 2016 to begin operation of the entire array. We discuss results of the initial physics runs, as well as the status and physics reach of the full MAJORANA DEMONSTRATOR experiment.
△ Less
Submitted 24 August, 2017;
originally announced August 2017.
-
The Processing of Enriched Germanium for the MAJORANA DEMONSTRATOR and R&D for a Possible Future Ton-Scale Ge-76 Double-Beta Decay Experiment
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
J. Caja,
M. Caja,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
D. T. Dunstan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known technology. However, because of the high cost of Ge enriched in Ge-76, special procedures were required to maximize the yield of detector mass and to minimize exposure…
▽ More
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known technology. However, because of the high cost of Ge enriched in Ge-76, special procedures were required to maximize the yield of detector mass and to minimize exposure to cosmic rays. These procedures include careful accounting for the material; shielding it to reduce cosmogenic generation of radioactive isotopes; and development of special reprocessing techniques for contaminated solid germanium, shavings, grindings, acid etchant and cutting fluids from detector fabrication. Processing procedures were developed that resulted in a total yield in detector mass of 70%. However, none of the acid-etch solution and only 50% of the cutting fluids from detector fabrication were reprocessed. Had they been processed, the projections for the recovery yield would be between 80 -- 85%. Maximizing yield is critical to justify a possible future ton-scale experiment. A process for recovery of germanium from the acid-etch solution was developed with yield of about 90%. All material was shielded or stored underground whenever possible to minimize the formation of Ge-68 by cosmic rays, which contributes background in the double-beta decay region of interest and cannot be removed by zone refinement and crystal growth. Formation of Ge-68 was reduced by a significant factor over that in natural abundance detectors not protected from cosmic rays.
△ Less
Submitted 19 July, 2017;
originally announced July 2017.
-
The Majorana Demonstrator calibration system
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
V. M. Gehman,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioact…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioactive line sources can be deployed around the cryostats containing the detectors for regular energy calibrations. When measuring in low-background mode, these line sources have to be stored outside the shielding so they do not contribute to the background. The deployment and the retraction of the source are designed to be controlled by the data acquisition system and do not require any direct human interaction. In this paper, we detail the design requirements and implementation of the calibration apparatus, which provides the event rates needed to define the pulse-shape cuts and energy calibration used in the final analysis as well as data that can be compared to simulations.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
New limits on Bosonic Dark Matter, Solar Axions, Pauli Exclusion Principle Violation, and Electron Decay from the Majorana Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. S. Guinn
, et al. (42 additional authors not shown)
Abstract:
We present new limits on exotic keV-scale physics based on 478 kg d of MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal-limits above our background. Our most stringent DM constraints are set for 11.8…
▽ More
We present new limits on exotic keV-scale physics based on 478 kg d of MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal-limits above our background. Our most stringent DM constraints are set for 11.8 keV mass particles, limiting $g_{Ae} <4.5\times 10^{-13}$ for pseudoscalars and $\frac{α'}α < 9.7\times 10^{-28}$ for vectors. We also report a 14.4 keV solar axion coupling limit of $g_{AN}^{\mathrm{eff}}\times g_{Ae}~<~3.8 \times 10^{-17}$, a $\frac{1}{2}β^2~<~8.5\times10^{-48}$ limit on the strength of PEPV electron transitions, and a lower limit on the electron lifetime of $τ_e > 1.2 \times 10^{24}\;$yr for $e^- \rightarrow$ invisible.
△ Less
Submitted 11 April, 2017; v1 submitted 2 December, 2016;
originally announced December 2016.
-
Search for Pauli Exclusion Principle Violating Atomic Transitions and Electron Decay with a P-type Point Contact Germanium Detector
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
P. S Finnerty,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (44 additional authors not shown)
Abstract:
A search for Pauli-exclusion-principle-violating K-alpha electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and Auger electr…
▽ More
A search for Pauli-exclusion-principle-violating K-alpha electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and Auger electrons present following the transition. A similar analysis was done to look for the decay of atomic K-shell electrons into neutrinos, resulting in a lower limit of 6.8x10^30 seconds at 90 C.L. It is estimated that the MAJORANA DEMONSTRATOR, a 44 kg array of p-type point contact detectors that will search for the neutrinoless double-beta decay of 76-Ge, could improve upon these exclusion limits by an order of magnitude after three years of operation.
△ Less
Submitted 19 October, 2016;
originally announced October 2016.
-
Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors
Authors:
J. Gruszko,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The Majorana Demonstrator searches for neutrinoless double-beta decay of $^{76}$Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular…
▽ More
The Majorana Demonstrator searches for neutrinoless double-beta decay of $^{76}$Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular detector arrays is posed by alpha particles. In the Majorana Demonstrator, events have been observed that are consistent with energy- degraded alphas originating on the passivated surface, leading to a potential background contribution in the region-of-interest for neutrinoless double-beta decay. However, it is also observed that when energy deposition occurs very close to the passivated surface, charges drift through the bulk onto that surface, and then drift along it with greatly reduced mobility. This leads to both a reduced prompt signal and a measurable change in slope of the tail of a recorded pulse. In this contribution we discuss the characteristics of these events and the development of a filter that can identify the occurrence of this delayed charge recovery, allowing for the efficient rejection of passivated surface alpha events in analysis.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Initial Results from the MAJORANA DEMONSTRATOR
Authors:
S. R. Elliott,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge)…
▽ More
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the first detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and first physics run, as well as the status and potential physics reach of the full {\sc Majorana Demonstrator} experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.
△ Less
Submitted 4 October, 2016;
originally announced October 2016.
-
Background model for the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing a system containing 44 kg of high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale to ~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y) in the 4…
▽ More
The MAJORANA Collaboration is constructing a system containing 44 kg of high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale to ~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y) in the 4 keV region of interest (ROI) around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials and analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements. Preliminary background results obtained during the engineering runs of the Demonstrator are presented.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
The Majorana Demonstrator search for neutrinoless double beta decay
Authors:
C. Cuesta,
M. Buuck,
J. A. Detwiler,
J. Gruszko,
I. S. Guinn,
J. Leon,
R. G. H. Robertson,
N. Abgrall,
A. W. Bradley,
Y-D. Chan,
S. Mertens,
A. W. P. Poon,
K. Vetter,
I. J. Arnquist,
E. W. Hoppe,
R. T. Kouzes,
J. L. Orrell,
F. T. Avignone III,
A. S. Barabash,
S. I. Konovalov,
V. Yumatov,
F. E. Bertrand,
A. Galindo-Uribarri,
D. C. Radford,
R. L. Varner
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.
△ Less
Submitted 29 August, 2016; v1 submitted 25 August, 2016;
originally announced August 2016.
-
High voltage testing for the MAJORANA Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett
, et al. (48 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector sign…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.
△ Less
Submitted 28 March, 2016; v1 submitted 28 March, 2016;
originally announced March 2016.
-
Muon Flux Measurements at the Davis Campus of the Sanford Underground Research Facility with the Majorana Demonstrator Veto System
Authors:
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (49 additional authors not shown)
Abstract:
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
△ Less
Submitted 7 September, 2016; v1 submitted 24 February, 2016;
originally announced February 2016.
-
High-Sensitivity Measurement of 3He-4He Isotopic Ratios for Ultracold Neutron Experiments
Authors:
H. P. Mumm,
M. G. Huber,
W. Bauder,
N. Abrams,
C. M. Deibel,
C. R. Huffer,
P. R. Huffman,
K. W. Schelhammer,
C. M. Swank,
R. Janssens,
C. L. Jiang,
R. H. Scott,
R. C. Pardo,
K. E. Rehm,
R. Vondrasek,
C. M. O'Shaughnessy,
M. Paul,
L. Yang
Abstract:
Research efforts ranging from studies of solid helium to searches for a neutron electric dipole moment require isotopically purified helium with a ratio of 3He to 4He at levels below that which can be measured using traditional mass spectroscopy techniques. We demonstrate an approach to such a measurement using accelerator mass spectroscopy, reaching the 10e-14 level of sensitivity, several orders…
▽ More
Research efforts ranging from studies of solid helium to searches for a neutron electric dipole moment require isotopically purified helium with a ratio of 3He to 4He at levels below that which can be measured using traditional mass spectroscopy techniques. We demonstrate an approach to such a measurement using accelerator mass spectroscopy, reaching the 10e-14 level of sensitivity, several orders of magnitude more sensitive than other techniques. Measurements of 3He/4He in samples relevant to the measurement of the neutron lifetime indicate the need for substantial corrections. We also argue that there is a clear path forward to sensitivity increases of at least another order of magnitude.
△ Less
Submitted 31 December, 2015;
originally announced December 2015.
-
Stochastic modeling and survival analysis of marginally trapped neutrons for a magnetic trap** neutron lifetime experiment
Authors:
K. J. Coakley,
M. S. Dewey,
M. G. Huber,
P. R. Huffman,
C. R. Huffer,
D. E. Marley,
H. P. Mumm,
C. M. O'Shaughnessy,
K. W. Schelhammer,
A. K. Thompson,
A. T. Yue
Abstract:
In a variety of neutron lifetime experiments, in addition to $β-$decay, neutrons can be lost by other mechanisms including wall losses. Failure to account for these other loss mechanisms produces systematic measurement error and associated systematic uncertainties in neutron lifetime measurements. In this work, we develop a physical model for neutron wall losses and construct a competing risks sur…
▽ More
In a variety of neutron lifetime experiments, in addition to $β-$decay, neutrons can be lost by other mechanisms including wall losses. Failure to account for these other loss mechanisms produces systematic measurement error and associated systematic uncertainties in neutron lifetime measurements. In this work, we develop a physical model for neutron wall losses and construct a competing risks survival analysis model to account for losses due to the joint effect of $β-$decay losses, wall losses of marginally trapped neutrons, and an additional absorption mechanism. We determine the survival probability function associated with the wall loss mechanism by a Monte Carlo method. Based on a fit of the competing risks model to a subset of the NIST experimental data, we determine the mean lifetime of trapped neutrons to be approximately 700 s -- considerably less than the current best estimate of (880.1 $\pm$ 1.1) s promulgated by the Particle Data Group [1]. Currently, experimental studies are underway to determine if this discrepancy can be explained by neutron capture by ${}^3$He impurities in the trap** volume. Analysis of the full NIST data will be presented in a later publication.
△ Less
Submitted 10 August, 2015;
originally announced August 2015.
-
Status of the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMON…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First, the prototype module was assembled; it has been continuously taking data from July 2014 to June 2015. Second, Module 1 with more than half of the total enriched detectors and some natural detectors has been assembled and it is being commissioned. Finally, the assembly of Module 2, which will complete MAJORANA DEMONSTRATOR, is already in progress.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR
Authors:
I. Guinn,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of…
▽ More
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of <3 counts/ROI-tonne-year, which is expected to scale down to <1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.
△ Less
Submitted 13 June, 2015;
originally announced June 2015.
-
Analysis techniques for background rejection at the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path f…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR 0s germanium detectors allows for significant reduction of gamma background.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR
Authors:
I. Guinn,
N. Abgrall,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
V. E. Guiseppe,
R. Henning,
E. W. Hoppe
, et al. (40 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0νββ$) in $^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the $ββ$ decay. Designing l…
▽ More
The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0νββ$) in $^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the $ββ$ decay. Designing low-noise electronics, which must be placed in close proximity to the detectors, presents a challenge to reaching this background target. This paper will discuss the MAJORANA collaboration's solutions to some of these challenges.
△ Less
Submitted 10 February, 2015;
originally announced February 2015.
-
The Majorana Parts Tracking Database
Authors:
The Majorana Collaboration,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (67 additional authors not shown)
Abstract:
The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and proc…
▽ More
The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radio-purity required for this rare decay search.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
-
MAJORANA Collaboration's Experience with Germanium Detectors
Authors:
S. Mertens,
N. Abgrall,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. Guinn,
V. E. Guiseppe,
R. Henning
, et al. (40 additional authors not shown)
Abstract:
The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search for 0$νββ$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for 0$νββ$, $^{76}\mathrm{Ge}$ has some of the most favorable characteristics. Germanium detectors are a well established technology, and in searches for 0$νββ$, the high purity germanium crystal acts simultaneously as source and detector. Furthermore, p-ty…
▽ More
The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search for 0$νββ$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for 0$νββ$, $^{76}\mathrm{Ge}$ has some of the most favorable characteristics. Germanium detectors are a well established technology, and in searches for 0$νββ$, the high purity germanium crystal acts simultaneously as source and detector. Furthermore, p-type germanium detectors provide excellent energy resolution and a specially designed point contact geometry allows for sensitive pulse shape discrimination. This paper will summarize the experiences the \textsc{Majorana} collaboration made with enriched germanium detectors manufactured by ORTEC$^{\circledR}$. The process from production, to characterization and integration in \textsc{Majorana} mounting structure will be described. A summary of the performance of all enriched germanium detectors will be given.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
-
The Majorana Demonstrator: A Search for Neutrinoless Double-beta Decay of 76Ge
Authors:
Majorana Collaboration,
W. Xu,
N. Abgrall,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. Guinn,
V. E. Guiseppe
, et al. (41 additional authors not shown)
Abstract:
Neutrinoless double-beta decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conser…
▽ More
Neutrinoless double-beta decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter-antimatter asymmetry in the universe. The observation of neutrinoless double-beta decay would also provide complementary information related to neutrino masses. The Majorana Collaboration is constructing the Majorana Demonstrator, a 40-kg modular germanium detector array, to search for the Neutrinoless double-beta decay of 76Ge and to demonstrate a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge Neutrinoless double-beta decay. In this paper, we discuss the physics of neutrinoless double beta decay and then focus on the Majorana Demonstrator, including its design and approach to achieve ultra-low backgrounds and the status of the experiment.
△ Less
Submitted 9 May, 2015; v1 submitted 13 January, 2015;
originally announced January 2015.
-
Status of the MAJORANA Demonstrator
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Greenn,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
R. Henning
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to d…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The current status of the Demonstrator is discussed, as are plans for its completion.
△ Less
Submitted 7 January, 2015; v1 submitted 17 December, 2014;
originally announced December 2014.
-
Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwel,
C. Cattadori,
A. Chernogorov,
V. D'Andrea
, et al. (87 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used…
▽ More
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new $^{76}$Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in GERDA during Phase I.
The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the $^{76}$Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of GERDA Phase~II.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
A Dark Matter Search with MALBEK
Authors:
G. K. Giovanetti,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (62 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimb…
▽ More
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is sensitive to potential non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and explore the impact of slow surface event contamination when searching for a WIMP signal.
△ Less
Submitted 8 July, 2014;
originally announced July 2014.