-
Comparison of Methods to Determine the Fluence of Monoenergetic Neutrons in the Energy Range from 30 keV to 14.8 MeV
Authors:
R. Nolte,
B. Lutz
Abstract:
The primary reference instruments for neutron fluence measurements used at the Physikalisch-Technische Bundesanstalt (PTB) are based on the primary standard for neutron measurements which is the differential neutron-proton scattering cross section. Such instruments require considerable effort for their operation and analysis. Therefore, routine measurements are carried out using a transfer instrum…
▽ More
The primary reference instruments for neutron fluence measurements used at the Physikalisch-Technische Bundesanstalt (PTB) are based on the primary standard for neutron measurements which is the differential neutron-proton scattering cross section. Such instruments require considerable effort for their operation and analysis. Therefore, routine measurements are carried out using a transfer instrument to facilitate the efficient provision of services to customers. A series of measurements was conducted to compare the transfer device to the primary reference instruments and ensure the traceability of neutron fluence measurements. This resulted in an improved characterization of the instrument and new analysis procedures.
△ Less
Submitted 26 June, 2024; v1 submitted 28 October, 2023;
originally announced October 2023.
-
A detector system for 'absolute' measurements of fission cross sections at n_TOF in the energy range below 200 MeV
Authors:
E. Pirovano,
A. Manna,
O. Aberle,
S. Amaducci,
N. Colonna,
P. Console Camprini,
L. Cosentino,
M. Dietz,
Q. Ducasse,
P. Finocchiaro,
C. Massimi,
A. Mengoni,
R. Nolte,
D. Radeck,
L. Tassan-Got,
N. Terranova,
G. Vannini
Abstract:
A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron scattering on hydrogen. This is a measurement first of its kind at this facility, in an energy range that was until now not often explored, so the detector development p…
▽ More
A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron scattering on hydrogen. This is a measurement first of its kind at this facility, in an energy range that was until now not often explored, so the detector development phase was crucial for its success. Two detectors are presented, a parallel plate fission chamber (PPFC) and a recoil proton telescope (RPT), both dedicated to perform measurements in the incident neutron energy range from 30 MeV to 200 MeV. The experiment was designed to minimize statistical uncertainties in the allocated run time. Several efforts were made to ensure that the systematic effects were understood and under control. The results show that the detectors are suited for measurements at n_TOF above 30 MeV, and indicate the path for possible future lines of development.
△ Less
Submitted 28 November, 2022; v1 submitted 22 November, 2022;
originally announced November 2022.
-
Recoil Proton Telescopes and Parallel Plate Avalanche Counters for the $^{235}$U(n,f) cross section measurement relative to H(n,n)H between 10 and 450 MeV neutron energy
Authors:
A. Manna,
E. Pirovano,
O. Aberle,
S. Amaducci,
M. Barbagallo,
D. M. Castelluccio,
N. Colonna,
P. Console Camprini,
L. Cosentino,
M. Dietz,
Q. Ducasse,
P. Finocchiaro,
C. Le Naour,
S. Lo Meo,
M. Mastromarco,
C. Massimi,
A. Mengoni,
P. M. Milazzo,
F. Mingrone,
R. Nolte,
M. Piscopo,
D. Radeck,
M. Spelta,
L. Tassan-Got,
N. Terranova
, et al. (1 additional authors not shown)
Abstract:
With the aim of measuring the $^{235}$U(n,f) cross section at the n\_TOF facility at CERN over a wide neutron energy range, a detection system consisting of two fission detectors and three detectors for neutron flux determination was realized. The neutron flux detectors are Recoil Proton Telescopes (RPT), based on scintillators and solid state detectors, conceived to detect recoil protons from the…
▽ More
With the aim of measuring the $^{235}$U(n,f) cross section at the n\_TOF facility at CERN over a wide neutron energy range, a detection system consisting of two fission detectors and three detectors for neutron flux determination was realized. The neutron flux detectors are Recoil Proton Telescopes (RPT), based on scintillators and solid state detectors, conceived to detect recoil protons from the neutron-proton elastic scattering reaction. This system, along with a fission chamber and an array of parallel plate avalanche counters for fission event detection, was installed for the measurement at the n\_TOF facility in 2018, at CERN.
An overview of the performances of two RPTs - especially developed for this measurement - and of the parallel plate avalanche counters are described in this article. In particular, the characterization in terms of detection efficiency by Monte Carlo simulations and response to neutron beam, the study of the background, dead time correction and characterization of the samples, are reported. The results of the present investigation show that the performances of these detectors are suitable for accurate measurements of fission reaction cross sections in the range from 10 to 450~MeV.
△ Less
Submitted 18 January, 2023; v1 submitted 22 November, 2022;
originally announced November 2022.
-
Direct measurement of the ionization quenching factor of nuclear recoils in germanium in the keV energy range
Authors:
A. Bonhomme,
H. Bonet,
C. Buck,
J. Hakenmüller,
G. Heusser,
T. Hugle,
M. Lindner,
W. Maneschg,
R. Nolte,
T. Rink,
E. Pirovano,
H. Strecker
Abstract:
This article reports the measurement of the ionization quenching factor in germanium for nuclear recoil energies between 0.4 and 6.3 keV$_{nr}$. Precise knowledge of this factor in this energy range is relevant for coherent elastic neutrino-nucleus scattering and low mass dark matter searches with germanium-based detectors. Nuclear recoils were produced in a thin high-purity germanium target with…
▽ More
This article reports the measurement of the ionization quenching factor in germanium for nuclear recoil energies between 0.4 and 6.3 keV$_{nr}$. Precise knowledge of this factor in this energy range is relevant for coherent elastic neutrino-nucleus scattering and low mass dark matter searches with germanium-based detectors. Nuclear recoils were produced in a thin high-purity germanium target with a very low energy threshold via irradiation with monoenergetic neutron beams. The energy dependence of the ionization quenching factor was directly measured via kinematically constrained coincidences with surrounding liquid scintillator based neutron detectors. The systematic uncertainties of the measurements are discussed in detail. With measured quenching factors between 0.16 and 0.23 in the [0.4, 6.3] keV$_{nr}$ energy range, the data are compatible with the Lindhard theory with a parameter $k$ of 0.162 $\pm$ 0.004 (stat+sys).
△ Less
Submitted 19 September, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
Calibration of the compact neutron spectrometer at PTB
Authors:
M. Osipenko,
V. Ceriale,
G. Gariano,
M. Girolami,
S. Cerchi,
R. Nolte,
E. Pirovano,
M. Ripani,
D. M. Trucchi
Abstract:
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2…
▽ More
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2, 100 um thick single crystal CVD commercial diamond plates. The measurements were performed in the fission spectrum domain at five different neutron energies varying from 0.3 up to 2 MeV. The obtained data showed a very good neutron energy reconstruction, i.e. in agreement with its reference values within statistical uncertainties or with deviation below 11 keV in absolute scale. The energy resolution of the spectrometer was found to be about 100 keV (RMS) with a small (about 9 keV/MeV) rising trend towards higher energies. The measured detection efficiency was found to be compatible with expectations based on analytical calculations and on Geant4 simulations within 3% statistical and 4% systematic precision.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.
-
Absolute efficiency calibration of 6LiF-based solid state thermal neutron detectors
Authors:
Paolo Finocchiaro,
Luigi Cosentino,
Sergio Lo Meo,
Ralf Nolte,
Desiree Radeck
Abstract:
The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of the art of…
▽ More
The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of the art of a promising low-cost technique, based on commercial solid state silicon detectors coupled with thin neutron converter layers of 6LiF deposited onto carbon fiber substrates. A few configurations were studied with the GEANT4 simulation code, and then calibrated at the PTB Thermal Neutron Calibration Facility. The results show that the measured detection efficiency is well reproduced by the simulations, therefore validating the simulation tool in view of new designs. These neutron detectors have also been tested at neutron beam facilities like ISIS (Rutherford Appleton Laboratory, UK) and n_TOF (CERN) where a few samples are already in operation for beam flux and 2D profile measurements. Forthcoming applications are foreseen for the online monitoring of spent nuclear fuel casks in interim storage sites.
△ Less
Submitted 8 January, 2018;
originally announced January 2018.
-
Experimental setup and procedure for the measurement of the 7Be(n,p)7Li reaction at n_TOF
Authors:
M. Barbagallo,
J. Andrzejewski,
M. Mastromarco,
J. Perkowski,
L. A. Damone,
A. Gawlik,
L. Cosentino,
P. Finocchiaro,
E. A. Maugeri,
A. Mazzone,
R. Dressler,
S. Heinitz,
N. Kivel,
D. Schumann,
N. Colonna,
O. Aberle,
S. Amaducci,
L. Audouin,
M. Bacak,
J. Balibrea,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar
, et al. (103 additional authors not shown)
Abstract:
Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron indiced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-liv…
▽ More
Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron indiced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-lived radioactive isotopes. After the successful measurement of the 7Be(n,α)α cross section, the 7Be(n,p)7Li reaction was studied in order to provide still missing cross section data of relevance for Big Bang Nucleosynthesis (BBN), in an attempt to find a solution to the cosmological Lithium abundance problem. This paper describes the experimental setup employed in such a measurement and its characterization.
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Characterization of a Deuterium-Deuterium Plasma Fusion Neutron Generator
Authors:
R. F. Lang,
J. Pienaar,
E. Hogenbirk,
D. Masson,
R. Nolte,
A Zimbal,
S. Röttger,
M. L. Benabderrahmane,
G Bruno
Abstract:
We characterize the neutron output of a deuterium-deuterium plasma fusion neutron generator, model 35-DD-W-S, manufactured by NSD/Gradel-Fusion. The measured energy spectrum is found to be dominated by neutron peaks at 2.2 MeV and 2.7 MeV. A detailed GEANT4 simulation accurately reproduces the measured energy spectrum and confirms our understanding of the fusion process in this generator. Addition…
▽ More
We characterize the neutron output of a deuterium-deuterium plasma fusion neutron generator, model 35-DD-W-S, manufactured by NSD/Gradel-Fusion. The measured energy spectrum is found to be dominated by neutron peaks at 2.2 MeV and 2.7 MeV. A detailed GEANT4 simulation accurately reproduces the measured energy spectrum and confirms our understanding of the fusion process in this generator. Additionally, a contribution of 14.1 MeV neutrons from deuterium-tritium fusion is found at a level of~$3.5\%$, from tritium produced in previous deuterium-deuterium reactions. We have measured both the absolute neutron flux as well as its relative variation on the operational parameters of the generator. We find the flux to be proportional to voltage $V^{3.32 \pm 0.14}$ and current $I^{0.97 \pm 0.01}$. Further, we have measured the angular dependence of the neutron emission with respect to the polar angle. We conclude that it is well described by isotropic production of neutrons within the cathode field cage.
△ Less
Submitted 1 September, 2017; v1 submitted 12 May, 2017;
originally announced May 2017.
-
Experimental setup and procedure for the measurement of the 7Be(n,α)α reaction at n_TOF
Authors:
L. Cosentino,
A. Musumarra,
M. Barbagallo,
A. Pappalardo,
N. Colonna,
L. Damone,
M. Piscopo,
P. Finocchiaro,
E. Maugeri,
S. Heinitz,
D. Schumann,
R. Dressler,
N. Kivel,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Ayranov,
M. Bacak,
S. Barros,
J. Balibrea-Correa,
V. Beecares,
F. Becvar,
C. Beinrucker,
E. Berthoumieux,
J. Billowes
, et al. (107 additional authors not shown)
Abstract:
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the…
▽ More
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the cosmological Lithium abundance problem, and whose only measurement, at thermal energy, dates back to 1963. The apparently unsurmountable experimental difficulties stemming from the huge 7Be γ-activity, along with the lack of a suitable neutron beam facility, had so far prevented further measurements. The detection system is subject to considerable radiation damage, but is capable of disentangling the rare reaction signals from the very high background. This newly developed setup could likely be useful also to study other challenging reactions requiring the detectors to be installed directly in the neutron beam.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Measurement of $α$-particle quenching in LAB based scintillator in independent small-scale experiments
Authors:
B. von Krosigk,
M. Chen,
S. Hans,
A. R. Junghans,
T. Kögler,
C. Kraus,
L. Kuckert,
X. Liu,
R. Nolte,
H. M. O'Keeffe,
H. S. Wan Chan Tseung,
J. R. Wilson,
A. Wright,
M. Yeh,
K. Zuber
Abstract:
The $α$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $α$-particles were produced in the scintillator via $^{12}$C($n$,$α$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\mathrm{nat}}$Sm providing an $α$-emitter, $^{147}$Sm, as an internal…
▽ More
The $α$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $α$-particles were produced in the scintillator via $^{12}$C($n$,$α$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\mathrm{nat}}$Sm providing an $α$-emitter, $^{147}$Sm, as an internal source. In the third approach, a scintillator flask was deployed into the water-filled SNO+ detector and the radioactive contaminants $^{222}$Rn, $^{218}$Po and $^{214}$Po provided the $α$-particle signal. The behavior of the observed $α$-particle light outputs are in agreement with each case successfully described by Birks' law. The resulting Birks parameter $kB$ ranges from $(0.0066\pm0.0016)$ cm/MeV to $(0.0076\pm0.0003)$ cm/MeV. In the first approach, the $α$-particle light response was measured simultaneously with the light response of recoil protons produced via neutron-proton elastic scattering. This enabled a first time a direct comparison of $kB$ describing the proton and the $α$-particle response of LAB based scintillator. The observed $kB$ values describing the two light response functions deviate by more than $5σ$. The presented results are valuable for all current and future detectors, using LAB based scintillator as target, since they depend on an accurate knowledge of the scintillator response to different particles.
△ Less
Submitted 13 March, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.
-
Measurement of the proton light response of various LAB based scintillators and its implication for supernova neutrino detection via neutrino-proton scattering
Authors:
B. von Krosigk,
L. Neumann,
R. Nolte,
S. Röttger,
K. Zuber
Abstract:
The proton light output function in electron-equivalent energy of various scintillators based on linear alkylbenzene (LAB) has been measured in the energy range from 1 MeV to 17.15 MeV for the first time. The measurement was performed at the Physikalisch-Technische Bundesanstalt (PTB) using a neutron beam with continuous energy distribution. The proton light output data is extracted from proton re…
▽ More
The proton light output function in electron-equivalent energy of various scintillators based on linear alkylbenzene (LAB) has been measured in the energy range from 1 MeV to 17.15 MeV for the first time. The measurement was performed at the Physikalisch-Technische Bundesanstalt (PTB) using a neutron beam with continuous energy distribution. The proton light output data is extracted from proton recoil spectra originating from neutron-proton scattering in the scintillator. The functional behavior of the proton light output is described succesfully by Birks' law with a Birks constant kB between (0.0094 +/- 0.0002) cm/MeV and (0.0098 +/- 0.0003) cm/MeV for the different LAB solutions. The constant C, parameterizing the quadratic term in the generalized Birks law, is consistent with zero for all investigated scintillators with an upper limit (95% CL) of about 10^{-7} cm^2/MeV^2. The resulting quenching factors are especially important for future planned supernova neutrino detection based on the elastic scattering of neutrinos on protons. The impact of proton quenching on the supernova event yield from neutrino-proton scattering is discussed.
△ Less
Submitted 16 April, 2013; v1 submitted 27 January, 2013;
originally announced January 2013.
-
Interferometry with Bose-Einstein Condensates in Microgravity
Authors:
H. Müntinga,
H. Ahlers,
M. Krutzik,
A. Wenzlawski,
S. Arnold,
D. Becker,
K. Bongs,
H. Dittus,
H. Duncker,
N. Gaaloul,
C. Gherasim,
E. Giese,
C. Grzeschik,
T. W. Hänsch,
O. Hellmig,
W. Herr,
S. Herrmann,
E. Kajari,
S. Kleinert,
C. Lämmerzahl,
W. Lewoczko-Adamczyk,
J. Malcolm,
N. Meyer,
R. Nolte,
A. Peters
, et al. (19 additional authors not shown)
Abstract:
Atom interferometers covering macroscopic domains of space-time are a spectacular manifestation of the wave nature of matter. Due to their unique coherence properties, Bose-Einstein condensates are ideal sources for an atom interferometer in extended free fall. In this paper we report on the realization of an asymmetric Mach-Zehnder interferometer operated with a Bose-Einstein condensate in microg…
▽ More
Atom interferometers covering macroscopic domains of space-time are a spectacular manifestation of the wave nature of matter. Due to their unique coherence properties, Bose-Einstein condensates are ideal sources for an atom interferometer in extended free fall. In this paper we report on the realization of an asymmetric Mach-Zehnder interferometer operated with a Bose-Einstein condensate in microgravity. The resulting interference pattern is similar to the one in the far-field of a double-slit and shows a linear scaling with the time the wave packets expand. We employ delta-kick cooling in order to enhance the signal and extend our atom interferometer. Our experiments demonstrate the high potential of interferometers operated with quantum gases for probing the fundamental concepts of quantum mechanics and general relativity.
△ Less
Submitted 24 January, 2013;
originally announced January 2013.
-
Characterization of Monoenergetic Neutron Reference Fields with a High Resolution Diamond Detector
Authors:
A. Zimbal,
L. Giacomelli,
R. Nolte,
H. Schuhmacher
Abstract:
A novel radiation detector based on an artificial single crystal diamond was used to characterize in detail the energy distribution of neutron reference fields at the Physikalisch-Technische Bundesanstalt (PTB) and their contamination with charged particles. The monoenergetic reference fields at PTB in the neutron energy range from 1.5 MeV up to 19 MeV are generated by proton and deuteron beams…
▽ More
A novel radiation detector based on an artificial single crystal diamond was used to characterize in detail the energy distribution of neutron reference fields at the Physikalisch-Technische Bundesanstalt (PTB) and their contamination with charged particles. The monoenergetic reference fields at PTB in the neutron energy range from 1.5 MeV up to 19 MeV are generated by proton and deuteron beams im**ing on solid and gas targets of tritium and deuterium. The energy of the incoming particles and the variation of the angle under which the measurement is performed produce monoenergetic reference fields with different mean energies and line shapes.
In this paper we present high resolution neutron spectrometry measurements of different monoenergetic reference fields. The results are compared with calculated spectra taking into account the actual target parameters. Line structures in the order of 80 keV for a neutron energy of 9 MeV were resolved. The shift of the mean energy and the increasing of the width of the neutron peak with increasing pressure in the gas target in the order of 30 keV were measured.
Another result is the determination of the contamination of the neutron field at 14 MeV with high energy charged particles (protons) from side reactions inside the T-target.
The experiments have shown that this detector is an easy to operate compact neutron spectrometer with extremely good energy resolution and that detailed structures in the line shapes of monoenergetic neutron fields can be resolved without using time of flight techniques.
△ Less
Submitted 26 November, 2009;
originally announced November 2009.
-
A Compact High-Energy Neutron Spectrometer
Authors:
F. D. Brooks,
A. Buffler,
M. S. Allie,
M. S. Herbert,
M. R. Nchodu,
D. T. L. Jones,
F. D. Smit,
R. Nolte,
V. Dangendorf
Abstract:
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts…
▽ More
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts versus pulse height and pulse shape) using the Bayesian unfolding code MAXED. Calibration and test measurements made using a pulsed neutron beam with a continuous energy spectrum are described and the application of the spectrometer to radiation dose measurements is discussed.
△ Less
Submitted 23 March, 2007;
originally announced March 2007.