-
A novel experimental system for the KDK measurement of the $^{40}$K decay scheme relevant for rare event searches
Authors:
M. Stukel,
B. C. Rasco,
N. T. Brewer,
P. C. F. Di Stefano,
K. P. Rykaczewski,
H. Davis,
E. D. Lukosi,
L. Hariasz,
M. Constable,
P. Davis,
K. Dering,
A. Fijałkowska,
Z. Gai,
K. C. Goetz,
R. K. Grzywacz,
J. Kostensalo,
J. Ninkovic,
P. Lechner,
Y. Liu,
M. Mancuso,
C. L. Melcher,
F. Petricca,
C. Rouleau,
P. Squillari,
L. Stand
, et al. (4 additional authors not shown)
Abstract:
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause…
▽ More
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr$_2$I$_5$:Eu scintillator as source and detector.
△ Less
Submitted 27 July, 2021; v1 submitted 30 December, 2020;
originally announced December 2020.
-
The KDK (potassium decay) experiment
Authors:
P. C. F. Di Stefano,
N. Brewer,
A. Fijałkowska,
Z. Gai,
K. C. Goetz,
R. Grzywacz,
D. Hamm,
P. Lechner,
Y. Liu,
E. Lukosi,
M. Mancuso,
C. Melcher,
J. Ninkovic,
F. Petricca,
B. C. Rasco,
C. Rouleau,
K. P. Rykaczewski,
P. Squillari,
L. Stand,
D. Stracener,
M. Stukel,
M. Wolińska-Cichocka,
I. Yavin
Abstract:
Potassium-40 (${}^{40}$K) is a background in many rare-event searches and may well play a role in interpreting results from the DAMA dark-matter search. The electron-capture decay of ${}^{40}$K to the ground state of ${}^{40}$Ar has never been measured and contributes an unknown amount of background. The KDK (potassium decay) collaboration will measure this branching ratio using a ${}^{40}$K sourc…
▽ More
Potassium-40 (${}^{40}$K) is a background in many rare-event searches and may well play a role in interpreting results from the DAMA dark-matter search. The electron-capture decay of ${}^{40}$K to the ground state of ${}^{40}$Ar has never been measured and contributes an unknown amount of background. The KDK (potassium decay) collaboration will measure this branching ratio using a ${}^{40}$K source, an X-ray detector, and the Modular Total Absorption Spectrometer at Oak Ridge National Laboratory.
△ Less
Submitted 10 November, 2017;
originally announced November 2017.
-
DEPFET detectors for direct detection of MeV Dark Matter particles
Authors:
Alexander Baehr,
Holger Kluck,
Jelena Ninkovic,
Jochen Schieck,
Johannes Treis
Abstract:
The existence of dark matter is undisputed, while the nature of it is still unknown. Explaining dark matter with the existence of a new unobserved particle is among the most promising possible solutions. Recently dark matter candidates in the MeV mass region received more and more interest. In comparison to the mass region between a few GeV to several TeV, this region is experimentally largely une…
▽ More
The existence of dark matter is undisputed, while the nature of it is still unknown. Explaining dark matter with the existence of a new unobserved particle is among the most promising possible solutions. Recently dark matter candidates in the MeV mass region received more and more interest. In comparison to the mass region between a few GeV to several TeV, this region is experimentally largely unexplored. We discuss the application of a RNDR DEPFET semiconductor detector for direct searches for dark matter in the MeV mass region. We present the working principle of the RNDR DEPFET devices and review the performance obtained by previously performed prototype measurements. The future potential of the technology as dark matter detector is discussed and the sensitivity for MeV dark matter detection with RNDR DEPFET sensors is presented. Under the assumption of three background events in the region of interest and an exposure of one kg$\cdot$y a sensitivity of $\barσ_{\bar{e}} = 10^{-41}$ cm$^{2}$ for dark matter particles with a mass of 10 MeV can be reached.
△ Less
Submitted 9 December, 2017; v1 submitted 27 June, 2017;
originally announced June 2017.
-
Integrated cooling channels in position-sensitive silicon detectors
Authors:
L. Andricek,
M. Boronat,
J. Fuster,
I. Garcia,
P. Gomis,
C. Marinas,
J. Ninkovic,
M. Perello Rosello,
M. A. Villarejo,
M. Vos
Abstract:
We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10~W/cm$^2$. The liquid flow is found to have a negligible impact on the mechanical performance. A finite-element simulation predicts the cooling performance to an…
▽ More
We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10~W/cm$^2$. The liquid flow is found to have a negligible impact on the mechanical performance. A finite-element simulation predicts the cooling performance to an accuracy of approximately 10~\%.
△ Less
Submitted 13 May, 2016; v1 submitted 29 April, 2016;
originally announced April 2016.
-
DEPFET active pixel detectors for a future linear $e^+e^-$ collider
Authors:
O. Alonso,
R. Casanova,
A. Dieguez,
J. Dingfelder,
T. Hemperek,
T. Kishishita amd T. Kleinohl,
M. Koch,
H. Krueger,
M. Lemarenko,
F. Luetticke,
C. Marinas,
M. Schnell,
N. Wermes,
A. Campbell,
T. Ferber,
C. Kleinwort,
C. Niebuhr,
Y. Soloviev,
M. Steder,
R. Volkenborn,
S. Yaschenko,
P. Fischer,
C. Kreidl,
I. Peric,
J. Knopf
, et al. (62 additional authors not shown)
Abstract:
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso…
▽ More
The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.
△ Less
Submitted 10 December, 2012;
originally announced December 2012.
-
Study of detection efficiency distribution and areal homogeneity of SiPMs
Authors:
Michal Tesař,
Christian Jendrysik,
Jelena Ninković,
Frank Simon
Abstract:
The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small scintillator cells 3x3x0.5 cm^3. This technology allows the construction of highly granular calorimeters used for excellent shower separation and therefore outst…
▽ More
The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small scintillator cells 3x3x0.5 cm^3. This technology allows the construction of highly granular calorimeters used for excellent shower separation and therefore outstanding jet energy resolution using the particle flow concept. Since the SiPMs still have potential for further improvements, we developed a setup dedicated to the measurement of parameters like the areal distribution of relative photon detection efficiency and crosstalk probability which are used to characterize and compare different devices. Thanks to the precise positioning system together with excellent focusing of the light source we are capable of scanning whole SiPMs with an area of ca. 1 mm^2 at a sub-pixel resolution of 1-2 μm. A further alignment compensation feature allows us to conduct separate analysis on each single pixel of a SiPM. We present the technical description of our measurement setup and results obtained for two types of SiPMs. The first one is a commercial Hamamatsu MPPC with 50 μm pixel size, the second one was the second iteration series SiMPl device developed and manufactured in the Semiconductor Laboratory of the Max Planck Institute.
△ Less
Submitted 27 November, 2012;
originally announced November 2012.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
The Belle-II Pixel Vertex Detector at the SuperKEKB Flavor Factory
Authors:
F. Simon,
K. Ackermann,
L. Andricek,
C. Heller,
C. Kiesling,
A. Moll,
H-G. Moser,
J. Ninkovic,
K. Prothmann,
B. Reisert,
R. Richter,
M. Ritter,
S. Rummel,
A Wassatsch
Abstract:
An upgraded asymmetric e+e- flavor factory, SuperKEKB, is planned at KEK. It will deliver a luminosity of 8 x 10^35 cm^-2 s^-1, allowing precision measurements in the flavor sector which can probe new physics well beyond the scales accessible to direct observation. The increased luminosity also requires upgrades of the Belle detector. Of critical importance here is a new silicon pixel vertex tra…
▽ More
An upgraded asymmetric e+e- flavor factory, SuperKEKB, is planned at KEK. It will deliver a luminosity of 8 x 10^35 cm^-2 s^-1, allowing precision measurements in the flavor sector which can probe new physics well beyond the scales accessible to direct observation. The increased luminosity also requires upgrades of the Belle detector. Of critical importance here is a new silicon pixel vertex tracker, which will significantly improve the decay vertex resolution. This new detector will consist of two detector layers close to the interaction point, using DEPFET pixel sensors with 50 um thick silicon in the active area.
△ Less
Submitted 4 February, 2010;
originally announced February 2010.
-
Interpretation of Light-Quenching Factor Measurements
Authors:
I. Bavykina,
P. Christ,
P. Huff,
J. Ninkovic,
F. Proebst,
W. Seidel,
L. Stodolsky
Abstract:
We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a saturation phenomenon in which the light output is simply proportional to track length, independent of the ion and its energy. This observation is in accord with the high dE/dx limit of Birks' law. It suggest…
▽ More
We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a saturation phenomenon in which the light output is simply proportional to track length, independent of the ion and its energy. This observation is in accord with the high dE/dx limit of Birks' law. It suggests a simple model for the intrinsic resolution of light detectors for low energy ions, which we briefly discuss.
△ Less
Submitted 5 July, 2007;
originally announced July 2007.