-
Alouette: Yet another encapsulated TAUOLA, but revertible
Authors:
Valentin Niess
Abstract:
We present an algorithm for simulating reverse Monte Carlo decays given an existing forward Monte Carlo decay engine. This algorithm is implemented in the Alouette library, a TAUOLA thin wrapper for simulating decays of tau-leptons. We provide a detailed description of Alouette, as well as validation results.
We present an algorithm for simulating reverse Monte Carlo decays given an existing forward Monte Carlo decay engine. This algorithm is implemented in the Alouette library, a TAUOLA thin wrapper for simulating decays of tau-leptons. We provide a detailed description of Alouette, as well as validation results.
△ Less
Submitted 25 August, 2022;
originally announced August 2022.
-
The PUMAS library
Authors:
Valentin Niess
Abstract:
The PUMAS library is a transport engine for muon and tau leptons in matter. It can operate with a configurable level of details, from a fast deterministic CSDA mode to a detailed Monte~Carlo simulation. A peculiarity of PUMAS is that it is revertible, i.e. it can run in forward or in backward mode. Thus, the PUMAS library is particularly well suited for muography applications. In the present docum…
▽ More
The PUMAS library is a transport engine for muon and tau leptons in matter. It can operate with a configurable level of details, from a fast deterministic CSDA mode to a detailed Monte~Carlo simulation. A peculiarity of PUMAS is that it is revertible, i.e. it can run in forward or in backward mode. Thus, the PUMAS library is particularly well suited for muography applications. In the present document, we provide a detailed description of PUMAS, of its physics and of its implementation.
△ Less
Submitted 3 June, 2022;
originally announced June 2022.
-
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
TURTLE: A C library for an optimistic step** through a topography
Authors:
Valentin Niess,
Anne Barnoud,
Cristina Cârloganu,
Olivier Martineau-Huynh
Abstract:
TURTLE is a C library providing utilities allowing to navigate through a topography described by a Digital Elevation Model (DEM). The library has been primarily designed for the Monte Carlo transport of particles scattering over medium to long ranges, e.g. atmospheric muons. But, it can also efficiently handle ray tracing problems with very large DEMs ($10^9$ nodes or more), e.g. for neutrino simu…
▽ More
TURTLE is a C library providing utilities allowing to navigate through a topography described by a Digital Elevation Model (DEM). The library has been primarily designed for the Monte Carlo transport of particles scattering over medium to long ranges, e.g. atmospheric muons. But, it can also efficiently handle ray tracing problems with very large DEMs ($10^9$ nodes or more), e.g. for neutrino simulations. The TURTLE library was built on an optimistic ray tracing algorithm, detailed in the present paper. This algorithm proceeds by trials and errors, approximating the topography within the modelling uncertainties of the DEM data. This allows to traverse a topography in constant time, i.e. independently of the number of grid nodes, and with no added memory. Detailed performance studies are provided by comparison to other ray tracing algorithms and as an application to muon transport in a Monte Carlo simulation.
△ Less
Submitted 13 September, 2019; v1 submitted 6 April, 2019;
originally announced April 2019.
-
COMET Phase-I Technical Design Report
Authors:
The COMET Collaboration,
R. Abramishvili,
G. Adamov,
R. R. Akhmetshin,
A. Allin,
J. C. Angélique,
V. Anishchik,
M. Aoki,
D. Aznabayev,
I. Bagaturia,
G. Ban,
Y. Ban,
D. Bauer,
D. Baygarashev,
A. E. Bondar,
C. Cârloganu,
B. Carniol,
T. T. Chau,
J. K. Chen,
S. J. Chen,
Y. E. Cheung,
W. da Silva,
P. D. Dauncey,
C. Densham,
G. Devidze
, et al. (170 additional authors not shown)
Abstract:
The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus ($μ-e$ conversion, $μ^- N \to e^- N$); a lepton flavor violating process. The experimental sensitivity goal for this process in the Phase-I experiment is…
▽ More
The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus ($μ-e$ conversion, $μ^- N \to e^- N$); a lepton flavor violating process. The experimental sensitivity goal for this process in the Phase-I experiment is $3.1\times10^{-15}$, or 90 % upper limit of branching ratio of $7\times 10^{-15}$, which is a factor of 100 improvement over the existing limit. The expected number of background events is 0.032. To achieve the target sensitivity and background level, the 3.2 kW 8 GeV proton beam from J-PARC will be used. Two types of detectors, CyDet and StrECAL, will be used for detecting the \mue conversion events, and for measuring the beam-related background events in view of the Phase-II experiment, respectively. Results from simulation on signal and background estimations are also described.
△ Less
Submitted 19 May, 2020; v1 submitted 21 December, 2018;
originally announced December 2018.
-
DANTON: a Monte-Carlo sampler of $τ$ from $ν_τ$ interacting with the Earth
Authors:
Valentin Niess,
Olivier Martineau-Huynh
Abstract:
A preliminary version (v0.2.1) of the DANTON Monte-Carlo package is presented. DANTON allows the exclusive sampling of (decaying) $τ$ generated by $ν_τ$ interactions with the Earth. The particles interactions with matter are simulated in detail, including transverse scattering. Detailed topography data of the Earth can be used as well. Yet, high Monte-Carlo efficiency is achieved by using a Backwa…
▽ More
A preliminary version (v0.2.1) of the DANTON Monte-Carlo package is presented. DANTON allows the exclusive sampling of (decaying) $τ$ generated by $ν_τ$ interactions with the Earth. The particles interactions with matter are simulated in detail, including transverse scattering. Detailed topography data of the Earth can be used as well. Yet, high Monte-Carlo efficiency is achieved by using a Backward Monte-Carlo technique. Some validation results are provided.
△ Less
Submitted 3 October, 2018;
originally announced October 2018.
-
Backward Monte-Carlo applied to muon transport
Authors:
Valentin Niess,
Anne Barnoud,
Cristina Carloganu,
Eve Le Menedeu
Abstract:
We discuss a backward Monte-Carlo technique for muon transport problem, with emphasis on its application in muography. Backward Monte-Carlo allows exclusive sampling of a final state by reversing the simulation flow. In practice it can be made analogous to an adjoint Monte-Carlo, though it is more versatile for muon transport. A backward Monte-Carlo was implemented as a dedicated muon transport li…
▽ More
We discuss a backward Monte-Carlo technique for muon transport problem, with emphasis on its application in muography. Backward Monte-Carlo allows exclusive sampling of a final state by reversing the simulation flow. In practice it can be made analogous to an adjoint Monte-Carlo, though it is more versatile for muon transport. A backward Monte-Carlo was implemented as a dedicated muon transport library: PUMAS. It is shown for case studies relevant for muography imaging that the implementations of forward and backward Monte-Carlo schemes agree to better than 1%.
△ Less
Submitted 7 September, 2017; v1 submitted 16 May, 2017;
originally announced May 2017.
-
Modelling theoretical uncertainties in phenomenological analyses for particle physics
Authors:
Jérôme Charles,
Sébastien Descotes-Genon,
Valentin Niess,
Luiz Vale Silva
Abstract:
The determination of the fundamental parameters of the Standard Model (and its extensions) is often limited by the presence of statistical and theoretical uncertainties. We present several models for the latter uncertainties (random, nuisance, external) in the frequentist framework, and we derive the corresponding $p$-values. In the case of the nuisance approach where theoretical uncertainties are…
▽ More
The determination of the fundamental parameters of the Standard Model (and its extensions) is often limited by the presence of statistical and theoretical uncertainties. We present several models for the latter uncertainties (random, nuisance, external) in the frequentist framework, and we derive the corresponding $p$-values. In the case of the nuisance approach where theoretical uncertainties are modeled as biases, we highlight the important, but arbitrary, issue of the range of variation chosen for the bias parameters. We introduce the concept of adaptive $p$-value, which is obtained by adjusting the range of variation for the bias according to the significance considered, and which allows us to tackle metrology and exclusion tests with a single and well-defined unified tool, which exhibits interesting frequentist properties. We discuss how the determination of fundamental parameters is impacted by the model chosen for theoretical uncertainties, illustrating several issues with examples from quark flavour physics.
△ Less
Submitted 7 April, 2017; v1 submitted 15 November, 2016;
originally announced November 2016.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.