Data downloaded via parachute from a NASA super-pressure balloon
Authors:
Ellen L. Sirks,
Richard Massey,
Ajay S. Gill,
Jason Anderson,
Steven J. Benton,
Anthony M. Brown,
Paul Clark,
Joshua English,
Spencer W. Everett,
Aurelien A. Fraisse,
Hugo Franco,
John W. Hartley,
David Harvey,
Bradley Holder,
Andrew Hunter,
Eric M. Huff,
Andrew Hynous,
Mathilde Jauzac,
William C. Jones,
Nikky Joyce,
Duncan Kennedy,
David Lagattuta,
Jason S. -Y. Leung,
Lun Li,
Stephen Lishman
, et al. (18 additional authors not shown)
Abstract:
In April to May 2023, the superBIT telescope was lifted to the Earth's stratosphere by a helium-filled super-pressure balloon, to acquire astronomical imaging from above (99.5% of) the Earth's atmosphere. It was launched from New Zealand then, for 40 days, circumnavigated the globe five times at a latitude 40 to 50 degrees South. Attached to the telescope were four 'DRS' (Data Recovery System) cap…
▽ More
In April to May 2023, the superBIT telescope was lifted to the Earth's stratosphere by a helium-filled super-pressure balloon, to acquire astronomical imaging from above (99.5% of) the Earth's atmosphere. It was launched from New Zealand then, for 40 days, circumnavigated the globe five times at a latitude 40 to 50 degrees South. Attached to the telescope were four 'DRS' (Data Recovery System) capsules containing 5 TB solid state data storage, plus a GNSS receiver, Iridium transmitter, and parachute. Data from the telescope were copied to these, and two were dropped over Argentina. They drifted 61 km horizontally while they descended 32 km, but we predicted their descent vectors within 2.4 km: in this location, the discrepancy appears irreducible below 2 km because of high speed, gusty winds and local topography. The capsules then reported their own locations to within a few metres. We recovered the capsules and successfully retrieved all of superBIT's data - despite the telescope itself being later destroyed on landing.
△ Less
Submitted 14 November, 2023;
originally announced November 2023.
-
A low-cost ultraviolet-to-infrared absolute quantum efficiency characterization system of detectors
Authors:
Ajay S. Gill,
Mohamed M. Shaaban,
Aaron Tohuvavohu,
Suresh Sivanandam,
Roberto G. Abraham,
Seery Chen,
Maria R. Drout,
Deborah Lokhorst,
Christopher D. Matzner,
Stefan W. Mochnacki,
Calvin B. Netterfield
Abstract:
We present a low-cost ultraviolet to infrared absolute quantum efficiency detector characterization system developed using commercial off-the-shelf components. The key components of the experiment include a light source,a regulated power supply, a monochromator, an integrating sphere, and a calibrated photodiode. We provide a step-by-step procedure to construct the photon and quantum efficiency tr…
▽ More
We present a low-cost ultraviolet to infrared absolute quantum efficiency detector characterization system developed using commercial off-the-shelf components. The key components of the experiment include a light source,a regulated power supply, a monochromator, an integrating sphere, and a calibrated photodiode. We provide a step-by-step procedure to construct the photon and quantum efficiency transfer curves of imaging sensors. We present results for the GSENSE 2020 BSI CMOS sensor and the Sony IMX 455 BSI CMOS sensor. As a reference for similar characterizations, we provide a list of parts and associated costs along with images of our setup.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Authors:
B. Osherson,
J. P. Filippini,
J. Fu,
R. V. Gramillano,
R. Gualtieri,
E. C. Shaw,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
J. E. Gudmundsson,
M. Halpern,
J. Hartley,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (23 additional authors not shown)
Abstract:
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers…
▽ More
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
J. P. Filippini,
A. A. Fraisse,
A. Gambrel,
N. N. Gandilo,
M. Hasselfield,
M. Halpern,
G. C. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin,
W. C. Jones,
Z. Kermish,
C. J. MacTavish,
P. V. Mason
, et al. (18 additional authors not shown)
Abstract:
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he…
▽ More
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
△ Less
Submitted 11 September, 2015; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Authors:
J. D. Soler,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
C. Chiang,
C. C. Contaldi,
B. P. Crill,
O. P. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (22 additional authors not shown)
Abstract:
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in…
▽ More
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Empirical modelling of the BLASTPol achromatic half-wave plate for precision submillimetre polarimetry
Authors:
Lorenzo Moncelsi,
Peter Ade,
Francesco Elio Angile,
Steven Benton,
Mark Devlin,
Laura Fissel,
Natalie Gandilo,
Joshua Gundersen,
Tristan Matthews,
C. Barth Netterfield,
Giles Novak,
David Nutter,
Enzo Pascale,
Frederick Poidevin,
Giorgio Savini,
Douglas Scott,
Juan Soler,
Locke Spencer,
Matthew Truch,
Gregory Tucker,
** Zhang
Abstract:
A cryogenic achromatic half-wave plate (HWP) for submillimetre astronomical polarimetry has been designed, manufactured, tested, and deployed in the Balloon-borne Large-Aperture Submillimeter Telescope for Polarimetry (BLASTPol). The design is based on the five-slab Pancharatnam recipe and it works in the wavelength range 200-600 micron, making it the broadest-band HWP built to date at (sub)millim…
▽ More
A cryogenic achromatic half-wave plate (HWP) for submillimetre astronomical polarimetry has been designed, manufactured, tested, and deployed in the Balloon-borne Large-Aperture Submillimeter Telescope for Polarimetry (BLASTPol). The design is based on the five-slab Pancharatnam recipe and it works in the wavelength range 200-600 micron, making it the broadest-band HWP built to date at (sub)millimetre wavelengths. The frequency behaviour of the HWP has been fully characterised at room and cryogenic temperatures with incoherent radiation from a polarising Fourier transform spectrometer. We develop a novel empirical model, complementary to the physical and analytical ones available in the literature, that allows us to recover the HWP Mueller matrix and phase shift as a function of frequency and extrapolated to 4K. We show that most of the HWP non-idealities can be modelled by quantifying one wavelength-dependent parameter, the position of the HWP equivalent axes, which is then readily implemented in a map-making algorithm. We derive this parameter for a range of spectral signatures of input astronomical sources relevant to BLASTPol, and provide a benchmark example of how our method can yield improved accuracy on measurements of the polarisation angle on the sky at submillimetre wavelengths.
△ Less
Submitted 13 November, 2013; v1 submitted 23 August, 2012;
originally announced August 2012.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Instrumental and Analytic Methods for Bolometric Polarimetry
Authors:
W. C. Jones,
T. E. Montroy,
B. P. Crill,
C. R. Contaldi,
T. S. Kisner,
A. E. Lange,
C. J. MacTavish,
C. B. Netterfield,
J. E. Ruhl
Abstract:
We discuss instrumental and analytic methods that have been developed for the first generation of bolometric cosmic microwave background (CMB) polarimeters. The design, characterization, and analysis of data obtained using Polarization Sensitive Bolometers (PSBs) are described in detail. This is followed by a brief study of the effect of various polarization modulation techniques on the recovery…
▽ More
We discuss instrumental and analytic methods that have been developed for the first generation of bolometric cosmic microwave background (CMB) polarimeters. The design, characterization, and analysis of data obtained using Polarization Sensitive Bolometers (PSBs) are described in detail. This is followed by a brief study of the effect of various polarization modulation techniques on the recovery of sky polarization from scanning polarimeter data. Having been successfully implemented on the sub-orbital Boomerang experiment, PSBs are currently operational in two terrestrial CMB polarization experiments (QUaD and the Robinson Telescope). We investigate two approaches to the analysis of data from these experiments, using realistic simulations of time ordered data to illustrate the impact of instrumental effects on the fidelity of the recovered polarization signal. We find that the analysis of difference time streams takes full advantage of the high degree of common mode rejection afforded by the PSB design. In addition to the observational efforts currently underway, this discussion is directly applicable to the PSBs that constitute the polarized capability of the Planck HFI instrument.
△ Less
Submitted 25 June, 2006;
originally announced June 2006.