-
Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection
Authors:
J. Schueler,
H. M. Araújo,
S. N. Balashov,
J. E. Borg,
C. Brew,
F. M. Brunbauer,
C. Cazzaniga,
A. Cottle,
C. D. Frost,
F. Garcia,
D. Hunt,
A. C. Kaboth,
M. Kastriotou,
I. Katsioulas,
A. Khazov,
P. Knights,
H. Kraus,
V. A. Kudryavtsev,
S. Lilley,
A. Lindote,
M. Lisowska,
D. Loomba,
M. I. Lopes,
E. Lopez Asamar,
P. Luna Dapica
, et al. (18 additional authors not shown)
Abstract:
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal…
▽ More
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal effect, using high-resolution image data from a state-of-the-art scientific CMOS camera in the MIGDAL experiment. The Migdal effect in nuclear scattering, crucial for sub-GeV dark matter searches, has yet to be experimentally confirmed, making its detection a primary goal of the MIGDAL experiment. Our pipeline employs the YOLOv8 object detection algorithm and is trained on real data to enhance the detection efficiency of nuclear and electronic recoils, particularly those exhibiting overlap** tracks that are indicative of the Migdal effect. When deployed online on the MIGDAL readout PC, we demonstrate our pipeline to process and perform the rare event search on 2D image data faster than the peak 120 frame per second acquisition rate of the CMOS camera. Applying these same steps offline, we demonstrate that we can reduce a sample of 20 million camera frames to around 1000 frames while maintaining nearly all signal that YOLOv8 is able to detect, thereby transforming a rare search into a much more manageable search. Our studies highlight the potential of pipelines similar to ours significantly improving the detection capabilities of experiments requiring rapid and precise object identification in high-throughput data environments.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
First operation of an ACHINOS-equipped Spherical Proportional Counter with individual anode read-out
Authors:
D. Herd,
I. Katsioulas,
P. Knights,
I. Manthos,
J. Matthews,
L. Millins,
T. Neep,
K. Nikolopoulos,
G. Rogers
Abstract:
The multi-anode sensor ACHINOS revolutionised the capabilities of the spherical proportional counter by enabling large-size, high-pressure, operation and TPC-like reconstruction capabilities through individual anode read-out. First measurements with an individually read out ACHINOS are performed, which enables improved calibration and response homogenisation. Experimental results demonstrating the…
▽ More
The multi-anode sensor ACHINOS revolutionised the capabilities of the spherical proportional counter by enabling large-size, high-pressure, operation and TPC-like reconstruction capabilities through individual anode read-out. First measurements with an individually read out ACHINOS are performed, which enables improved calibration and response homogenisation. Experimental results demonstrating the improvement in energy resolution brought by the individual anode calibration are presented. These are complemented by detailed simulation studies on the effect of sensor design and manufacturing imperfections, and how they may be corrected both in hardware and analysis.
△ Less
Submitted 18 January, 2024; v1 submitted 26 September, 2023;
originally announced September 2023.
-
Performance of a spherical high pressure gas TPC for neutrino magnetic moment measurement
Authors:
R. Bouet,
J. Busto,
V. Cecchini,
C. Cerna,
P. Charpentier,
A. Dastgheibi-Fard,
F. Druillole,
C. Jollet,
P. Hellmuth,
I. Katsioulas,
P. Knights,
I. Giomataris,
M. Gros,
P. Lautridou,
A. Meregaglia,
X. F. Navick,
T. Neep,
K. Nikolopoulos,
F. Perrot,
F. Piquemal,
M. Roche,
B. Thomas,
R. Ward
Abstract:
The measurement of neutrino magnetic moment larger than $10^{-19}μ_B$ would be a clear signature of physics beyond the standard model other than the existence of massive Dirac neutrinos. The use of a spherical proportional counter detector filled with gas at 40 bar located near a nuclear reactor would be a simple way to perform such a measurement exploiting the developments made on such a technolo…
▽ More
The measurement of neutrino magnetic moment larger than $10^{-19}μ_B$ would be a clear signature of physics beyond the standard model other than the existence of massive Dirac neutrinos. The use of a spherical proportional counter detector filled with gas at 40 bar located near a nuclear reactor would be a simple way to perform such a measurement exploiting the developments made on such a technology for the search of dark matter and neutrinoless double beta decay. Different targets can be used just by replacing the gas: xenon, CF$_4$ and argon were compared and the sensitivity in one year of data taking could reach the level of $4.3 \times 10^{-12} μ_B$, $6.5 \times 10^{-12} μ_B$, and $8.5 \times 10^{-12} μ_B$, respectively.
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
ACHINOS: A Multi-Anode Read-Out for Position Reconstruction and Tracking with Spherical Proportional Counters
Authors:
I. Katsioulas,
P. Knights,
I. Manthos,
J. Matthews,
T. Neep,
K. Nikolopoulos,
R. Ward
Abstract:
The spherical proportional counter is a versatile gaseous detector with physics applications ranging from rare event searches to fast neutron spectroscopy. In its simplest form, the detector operates with a single channel read-out, and uses pulse-shape information to reconstruct the interaction radius, which is used for background discrimination and target volume definition. Recent developments in…
▽ More
The spherical proportional counter is a versatile gaseous detector with physics applications ranging from rare event searches to fast neutron spectroscopy. In its simplest form, the detector operates with a single channel read-out, and uses pulse-shape information to reconstruct the interaction radius, which is used for background discrimination and target volume definition. Recent developments in the read-out instrumentation have enabled the use of a multi-anode read-out structure, ACHINOS. The multiple anodes provide information about the interaction position which, coupled with the radial information, can be used to reconstruct an ionisation track. This ability has implications for several applications of the detector, for example, background discrimination in rare event searches.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors
Authors:
K.,
Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafní,
D. Díez-Ibáñez,
J. Galán,
J. Galindo,
J. A. García,
I. G. Irastorza,
I. Katsioulas,
P. Knights,
G. Luzón,
I. Manthos,
C. Margalejo,
J. Matthews,
K. Mavrokoridis,
H. Mirallas,
T. Neep,
K. Nikolopoulos,
L. Obis,
A. Ortiz de Solórzano,
O. Pérez,
B. Philippou,
R. Ward
Abstract:
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potenti…
▽ More
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
Neutron spectroscopy: The case of the spherical proportional counter
Authors:
I. Giomataris,
I. Katsioulas,
P. Knights,
I. Manthos,
T. Neep,
K. Nikolopoulos,
T. Papaevangelou,
R. Ward
Abstract:
Neutron spectroscopy is an invaluable tool for many scientific and industrial applications, including underground Dark Matter searches. Neutron-induced backgrounds produced by cosmic ray muons and the cavern radioactivity can mimic the expected Dark Matter signal. However, existing neutron detection methods have several drawbacks and limitations, thus measurements remain elusive. A promising new a…
▽ More
Neutron spectroscopy is an invaluable tool for many scientific and industrial applications, including underground Dark Matter searches. Neutron-induced backgrounds produced by cosmic ray muons and the cavern radioactivity can mimic the expected Dark Matter signal. However, existing neutron detection methods have several drawbacks and limitations, thus measurements remain elusive. A promising new approach to neutron spectroscopy is the use of a nitrogen-filled spherical proportional counter that exploits the $^{14}$N(n,$α$)$^{11}$B and $^{14}$N(n, p)$^{14}$C reactions. This is a safe, inexpensive, effective and reliable technique. In this work, the latest instrumentation developments are incorporated in a compact detector operated at the University of Birmingham (UoB) with high gain at gas pressure up to 1.8\,bar. We demonstrate spectroscopic measurements of thermalised and fast neutrons respectively from an $^{241}$Am-$^9$Be source and from the MC40 cyclotron facility at UoB. Additionally, the detector response to neutrons is simulated using a framework developed at UoB and compared with the experimental results.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter
Authors:
H. M. Araújo,
S. N. Balashov,
J. E. Borg,
F. M. Brunbauer,
C. Cazzaniga,
C. D. Frost,
F. Garcia,
A. C. Kaboth,
M. Kastriotou,
I. Katsioulas,
A. Khazov,
H. Kraus,
V. A. Kudryavtsev,
S. Lilley,
A. Lindote,
D. Loomba,
M. I. Lopes,
E. Lopez Asamar,
P. Luna Dapica,
P. A. Majewski,
T. Marley,
C. McCabe,
A. F. Mills,
M. Nakhostin,
T. Neep
, et al. (11 additional authors not shown)
Abstract:
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to…
▽ More
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$σ$ median discovery significance can be achieved in under one day with either generator.
△ Less
Submitted 5 May, 2023; v1 submitted 17 July, 2022;
originally announced July 2022.
-
Neutron spectroscopy with a high-pressure nitrogen-filled spherical proportional counter
Authors:
I. Giomataris,
S. Green,
I. Katsioulas,
P. Knights,
I. Manthos,
T. Neep,
K. Nikolopoulos,
T. Papaevangelou,
B. Phoenix,
J. Sanders,
R. Ward
Abstract:
The spherical proportional counter is a large volume gaseous detector which finds application in several fields, including direct Dark Matter searches. When the detector is filled with nitrogen it becomes an effective neutron spectrometer thanks to the $^{14}$N(n,$\mathrmα$)$^{11}$B and $^{14}$N(n,p)$^{14}$C reactions. Nitrogen, however, is a challenging operating gas for proportional counters and…
▽ More
The spherical proportional counter is a large volume gaseous detector which finds application in several fields, including direct Dark Matter searches. When the detector is filled with nitrogen it becomes an effective neutron spectrometer thanks to the $^{14}$N(n,$\mathrmα$)$^{11}$B and $^{14}$N(n,p)$^{14}$C reactions. Nitrogen, however, is a challenging operating gas for proportional counters and requires a high electric field strength to gas pressure ratio. Benefiting from the latest advances in spherical proportional counter instrumentation and simulation techniques, we report first neutron measurements at operating pressures of up to 1.8 bar. This achievement enhances the prospects of the spherical proportional counter to act as a neutron spectrometer appropriate for challenging environments, including underground laboratories, and industrial and medical settings.
△ Less
Submitted 13 February, 2023; v1 submitted 9 June, 2022;
originally announced June 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Simultaneous scintillation light and charge readout of a pure argon filled Spherical Proportional Counter
Authors:
R. Bouet,
J. Busto,
V. Cecchini,
C. Cerna,
A. Dastgheibi-Fard,
F. Druillole,
C. Jollet,
P. Hellmuth,
I. Katsioulas,
P. Knights,
I. Giomataris,
M. Gros,
P. Lautridou,
A. Meregaglia,
X. F. Navick,
T. Neep,
K. Nikolopoulos,
F. Perrot,
F. Piquemal,
M. Roche,
B. Thomas,
R. Ward,
M. Zampaolo
Abstract:
The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were carried out with pure argon at 1.1 bar using a 6x6 mm2 silicon photomultiplier. Scintillation light was used for the first time to trigger in a spherical proportion…
▽ More
The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were carried out with pure argon at 1.1 bar using a 6x6 mm2 silicon photomultiplier. Scintillation light was used for the first time to trigger in a spherical proportional counter. The measured drift time is in excellent agreement with the expectations from simulations. Furthermore the light signal emitted during the avalanche development exhibits features that could be exploited for event characterisation.
△ Less
Submitted 29 January, 2022;
originally announced January 2022.
-
Measurements of the ionization efficiency of protons in methane
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi-Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (19 additional authors not shown)
Abstract:
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below…
▽ More
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^α~/~(β+ E_K^α)$ with $α=0.70\pm0.08$ and $β= 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$
△ Less
Submitted 25 June, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Non-Parametric Data-Driven Background Modelling using Conditional Probabilities
Authors:
A. Chisholm,
T. Neep,
K. Nikolopoulos,
R. Owen,
E. Reynolds,
J. Silva
Abstract:
Background modelling is one of the main challenges in particle physics data analysis. Commonly employed strategies include the use of simulated events of the background processes, and the fitting of parametric background models to the observed data. However, reliable simulations are not always available or may be extremely costly to produce. As a result, in many cases, uncertainties associated wit…
▽ More
Background modelling is one of the main challenges in particle physics data analysis. Commonly employed strategies include the use of simulated events of the background processes, and the fitting of parametric background models to the observed data. However, reliable simulations are not always available or may be extremely costly to produce. As a result, in many cases, uncertainties associated with the accuracy or sample size of the simulation are the limiting factor in the analysis sensitivity. At the same time, parametric models are limited by the a priori unknown functional form and parameter values of the background distribution. These issues become ever more pressing when large datasets become available, as it is already the case at the CERN Large Hadron Collider, and when studying exclusive signatures involving hadronic backgrounds.
Two novel and widely applicable non-parametric data-driven background modelling techniques are presented, which address these issues for a broad class of searches and measurements. The first, relying on ancestral sampling, uses data from a relaxed event selection to estimate a graph of conditional probability density functions of the variables used in the analysis, accounting for significant correlations. A background model is then generated by sampling events from this graph, before the full event selection is applied. In the second, a generative adversarial network is trained to estimate the joint probability density function of the variables used in the analysis. The training is performed on a relaxed event selection which excludes the signal region, and the network is conditioned on a blinding variable. Subsequently, the conditional probability density function is interpolated into the signal region to model the background. The application of each method on a benchmark analysis is presented in detail, and the performance is discussed.
△ Less
Submitted 4 October, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
Quenching factor measurements of neon nuclei in neon gas
Authors:
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
L. Kwon
, et al. (25 additional authors not shown)
Abstract:
The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E…
▽ More
The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.
△ Less
Submitted 3 December, 2021; v1 submitted 2 September, 2021;
originally announced September 2021.
-
Neutron spectroscopy with N$_2$-filled high-pressure large-volume spherical proportional counters
Authors:
I. Giomataris,
S. Green,
I. Katsioulas,
P. Knights,
I. Manthos,
J. Matthews,
T. Neep,
K. Nikolopoulos,
T. Papaevangelou,
B. Phoenix,
J. Sanders,
R. Ward
Abstract:
Precise in-situ measurements of the neutron flux in underground laboratories is crucial for direct dark matter searches, as neutron induced backgrounds can mimic the typical dark matter signal. The development of a novel neutron spectroscopy technique using Spherical Proportional Counters is investigated. The detector is operated with nitrogen and is sensitive to both fast and thermal neutrons thr…
▽ More
Precise in-situ measurements of the neutron flux in underground laboratories is crucial for direct dark matter searches, as neutron induced backgrounds can mimic the typical dark matter signal. The development of a novel neutron spectroscopy technique using Spherical Proportional Counters is investigated. The detector is operated with nitrogen and is sensitive to both fast and thermal neutrons through the $^{14}$N(n, $α$)$^{11}$B and $^{14}$N(n, p)$^{14}$C reactions. This method holds potential to be a safe, inexpensive, effective, and reliable alternative to $^3$He-based detectors. Measurements of fast and thermal neutrons from an Am-Be source with a Spherical Proportional Counter operated at pressures up to 2 bar at Birmingham are discussed.
△ Less
Submitted 6 July, 2021;
originally announced July 2021.
-
Copper electroplating for background suppression in the NEWS-G experiment
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
R. Bunker,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (26 additional authors not shown)
Abstract:
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper.…
▽ More
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.
△ Less
Submitted 13 December, 2020; v1 submitted 7 August, 2020;
originally announced August 2020.
-
R2D2 spherical TPC: first energy resolution results
Authors:
R. Bouet,
J. Busto,
V. Cecchini,
C. Cerna,
A. Dastgheibi-Fard,
F. Druillole,
C. Jollet,
P. Hellmuth,
I. Katsioulas,
P. Knights,
I. Giomataris,
M. Gros,
P. Lautridou,
A. Meregaglia,
X. F. Navick,
T. Neep,
K. Nikolopoulos,
F. Perrot,
F. Piquemal,
M. Roche,
B. Thomas,
R. Ward,
M. Zampaolo
Abstract:
Spherical time projection chambers (TPC), also known as spherical proportional counters, are employed in the search for rare phenomena, such as light Dark Matter candidates. The spherical TPC exhibits a number of essential features, making it a promising candidate for the search of neutrinoless double beta decay ($β\beta0ν$). A tonne-scale spherical TPC experiment could cover a region of parameter…
▽ More
Spherical time projection chambers (TPC), also known as spherical proportional counters, are employed in the search for rare phenomena, such as light Dark Matter candidates. The spherical TPC exhibits a number of essential features, making it a promising candidate for the search of neutrinoless double beta decay ($β\beta0ν$). A tonne-scale spherical TPC experiment could cover a region of parameter space relevant for the inverted mass hierarchy with a few years of data taking. In this direction, the major R\&D goal of the R2D2 effort is the demonstration of the required energy resolution. First results from an argon-filled prototype detector are reported, demonstrating an energy resolution of 1.1\% FWHM for 5.3~MeV $α$ tracks in the 0.2 to 1.1~bar pressure range. This is a major milestone in terms of energy resolution, paving the way for further studies with xenon gas, and the possible use of this technology for $β\beta0ν$ searches.
△ Less
Submitted 11 January, 2021; v1 submitted 6 July, 2020;
originally announced July 2020.
-
A resistive ACHINOS multi-anode structure with DLC coating for spherical proportional counters
Authors:
I. Giomataris,
M. Gros,
I. Katsioulas,
P. Knights,
J. -P. Mols,
T. Neep,
K. Nikolopoulos,
G. Savvidis,
I. Savvidis,
L. Shang,
R. Ward,
Y. Zhou
Abstract:
The spherical proportional counter is a gaseous detector used in a variety of applications, including direct dark matter and neutrino-less double beta decay searches. The ACHINOS multianode structure is a read-out technology that overcomes the limitations of single-anode read-out structures for large-size detectors and operation under high pressure. A resistive ACHINOS is presented, where the 3D p…
▽ More
The spherical proportional counter is a gaseous detector used in a variety of applications, including direct dark matter and neutrino-less double beta decay searches. The ACHINOS multianode structure is a read-out technology that overcomes the limitations of single-anode read-out structures for large-size detectors and operation under high pressure. A resistive ACHINOS is presented, where the 3D printed central component is coated in a Diamond-Like Carbon (DLC) layer. The production and testing of the structure, in terms of stability and resolution, is described. Further applications in fundamental physics and industry are also discussed.
△ Less
Submitted 26 October, 2020; v1 submitted 2 March, 2020;
originally announced March 2020.
-
Development of a Simulation Framework for Spherical Proportional Counters
Authors:
I. Katsioulas,
P. Knights,
J. Matthews,
T. Neep,
K. Nikolopoulos,
R. Owen,
R. Ward
Abstract:
The spherical proportional counter is a novel gaseous detector with numerous applications, including direct dark matter searches and neutron spectroscopy. The strengths of the Geant4 and Garfield++ toolkits are combined to create a simulation framework for spherical proportional counters. The interface is implemented by introducing Garfield++ classes within a Geant4 application. Simulated muon, el…
▽ More
The spherical proportional counter is a novel gaseous detector with numerous applications, including direct dark matter searches and neutron spectroscopy. The strengths of the Geant4 and Garfield++ toolkits are combined to create a simulation framework for spherical proportional counters. The interface is implemented by introducing Garfield++ classes within a Geant4 application. Simulated muon, electron, and photon signals are presented, and the effects of gas mixture composition and anode support structure on detector response are discussed.
△ Less
Submitted 8 June, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.