-
Microwave Technologies in Experiments for Detection of Dark Matter Axions
Authors:
Jose R. Navarro-Madrid,
Jose María García-Barceló,
Alejandro Díaz-Morcillo
Abstract:
This article reviews different microwave technologies used in dark matter axion detection experiments with resonant cavities. The general concepts of the experiment are presented and ways to optimize the design parameters of microwave resonators are discussed. Additionally, different frequency tuning systems are described. Finally, research lines where microwave engineering can contribute to this…
▽ More
This article reviews different microwave technologies used in dark matter axion detection experiments with resonant cavities. The general concepts of the experiment are presented and ways to optimize the design parameters of microwave resonators are discussed. Additionally, different frequency tuning systems are described. Finally, research lines where microwave engineering can contribute to this kind of axion detection are presented.
△ Less
Submitted 30 April, 2024; v1 submitted 24 April, 2024;
originally announced April 2024.
-
RADES axion search results with a High-Temperature Superconducting cavity in an 11.7 T magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
X. Granados,
J. Gutierrez,
L. Herwig,
I. G. Irastorza,
N. Lamas,
A. Lozano-Guerrero,
W. L. Millar,
C. Malbrunot,
J. Miralda-Escudé,
P. Navarro,
J. R. Navarro-Madrid,
T. Puig,
M. Siodlaczek,
G. T. Telles
, et al. (1 additional authors not shown)
Abstract:
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hint…
▽ More
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hinting at an axion-like particle was found. Correspondingly, in this mass range, a limit on the axion to photon coupling-strength was set in the range between g$_{aγ}\gtrsim$ 6.2e-13 GeV$^{-1}$ and g$_{aγ}\gtrsim$ 1.54e-13 GeV$^{-1}$ with a 95% confidence level.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
A proposal for a low-frequency axion search in the 1-2 $μ$eV range and below with the BabyIAXO magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
J. Devlin,
A. Díaz-Morcillo,
D. Díez-Ibáñez,
B. Döbrich,
J. Galindo,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
Y. Gu,
L. Herwig,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
J. Miralda-Escudé,
J. Monzó-Cabrera,
P. Navarro,
J. R. Navarro-Madrid,
J. Redondo,
J. Reina-Valero
, et al. (5 additional authors not shown)
Abstract:
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential se…
▽ More
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential sensitivity to the axion-photon coupling $g_{aγ}$ down to values corresponding to the KSVZ model, in the (currently unexplored) mass range between 1 and 2$~μ$eV, after a total effective exposure of 440 days. This mass range is covered by the use of four differently dimensioned 5-meter-long cavities, equipped with a tuning mechanism based on inner turning plates. A setup like the one proposed would also allow an exploration of the same mass range for hidden photons coupled to photons. An additional complementary apparatus is proposed using LC circuits and exploring the low energy range ($\sim10^{-4}-10^{-1}~μ$eV). The setup includes a cryostat and cooling system to cool down the BabyIAXO bore down to about 5 K, as well as appropriate low-noise signal amplification and detection chain.
△ Less
Submitted 22 November, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Methods and restrictions to increase the volume of resonant rectangular-section haloscopes for detecting dark matter axions
Authors:
J. M. García-Barceló,
A. Álvarez Melcón,
A. Díaz-Morcillo,
B. Gimeno,
A. J. Lozano-Guerrero,
J. Monzo-Cabrera,
J. R. Navarro-Madrid,
P. Navarro
Abstract:
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explore…
▽ More
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explored: based on single cavities and based on multicavities. For both cases, possibilities for increasing the volume in long and/or tall structures are presented. For multicavities, 1D geometries are explored to optimize the space in the magnets. Also, 2D and 3D geometries are introduced as a first step for laying the foundations for the development of these kind of topologies. The results prove the usefulness of the developed methods, evidencing the ample room of improvement in rectangular haloscope designs nowadays. A factor of three orders of magnitude improvement in volume compared with a single cavity based on WR-90 standard waveguide is obtained with the design of a long and tall single cavity. Similar procedures have been applied for long and tall multicavities. Experimental measurements are shown for prototypes based on tall multicavities and 2D structures, demonstrating the feasibility of using these types of geometries to increase the volume in real haloscopes.
△ Less
Submitted 24 February, 2023; v1 submitted 21 February, 2023;
originally announced February 2023.
-
The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
Authors:
Beatriz Aja,
Sergio Arguedas Cuendis,
Ivan Arregui,
Eduardo Artal,
R. Belén Barreiro,
Francisco J. Casas,
Maria C. de Ory,
Alejandro Díaz-Morcillo,
Luisa de la Fuente,
Juan Daniel Gallego,
José María García-Barceló,
Benito Gimeno,
Alicia Gomez,
Daniel Granados,
Bradley J. Kavanagh,
Miguel A. G. Laso,
Txema Lopetegi,
Antonio José Lozano-Guerrero,
Maria T. Magaz,
Jesús Martín-Pintado,
Enrique Martínez-González,
Jordi Miralda-Escudé,
Juan Monzó-Cabrera,
Jose R. Navarro-Madrid,
Ana B. Nuñez Chico
, et al. (11 additional authors not shown)
Abstract:
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field cou…
▽ More
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented.
△ Less
Submitted 6 June, 2022;
originally announced June 2022.