-
RADES axion search results with a High-Temperature Superconducting cavity in an 11.7 T magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
X. Granados,
J. Gutierrez,
L. Herwig,
I. G. Irastorza,
N. Lamas,
A. Lozano-Guerrero,
W. L. Millar,
C. Malbrunot,
J. Miralda-Escudé,
P. Navarro,
J. R. Navarro-Madrid,
T. Puig,
M. Siodlaczek,
G. T. Telles
, et al. (1 additional authors not shown)
Abstract:
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hint…
▽ More
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hinting at an axion-like particle was found. Correspondingly, in this mass range, a limit on the axion to photon coupling-strength was set in the range between g$_{aγ}\gtrsim$ 6.2e-13 GeV$^{-1}$ and g$_{aγ}\gtrsim$ 1.54e-13 GeV$^{-1}$ with a 95% confidence level.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
Acoustic Screens based on Sonic Crystals with high Diffusion properties
Authors:
M. P. Peiró-Torres,
M. J. Parrilla Navarro,
M. Ferri,
J. M. Bravo,
J. V. Sánchez-Pérez,
J. Redondo
Abstract:
This article presents the use of advanced tools applied to the design of devices that can solve specific acoustic problems, improving the already existing devices based on classic technologies. Specifically, we have used two different configurations of a material called Sonic Crystals, which is formed by arrays of acoustic scatterers, to obtain acoustic screens with high diffusion properties by me…
▽ More
This article presents the use of advanced tools applied to the design of devices that can solve specific acoustic problems, improving the already existing devices based on classic technologies. Specifically, we have used two different configurations of a material called Sonic Crystals, which is formed by arrays of acoustic scatterers, to obtain acoustic screens with high diffusion properties by means of an optimization process. This design procedure has been carried out using a multiobjective evolutionary algorithm along to an acoustic simulation model developed with the numerical method called Finite Difference Time Domain (FDTD). The results obtained are discussed in terms of both the acoustic performance and the robustness of the devices achieved.
△ Less
Submitted 29 January, 2024;
originally announced January 2024.
-
Study of a cubic cavity resonator for gravitational waves detection in the microwave frequency range
Authors:
Pablo Navarro,
Benito Gimeno,
Juan Monzó-Cabrera,
Alejandro Díaz-Morcillo,
Diego Blas
Abstract:
The direct detection of gravitational waves (GWs) of frequencies above MHz has recently received considerable attention. In this work we present a precise study of the reach of a cubic cavity resonator to GWs in the microwave range, using for the first time tools allowing to perform realistic simulations. Concretely, the BI-RME 3D method, which allows us to obtain not only the detected power but a…
▽ More
The direct detection of gravitational waves (GWs) of frequencies above MHz has recently received considerable attention. In this work we present a precise study of the reach of a cubic cavity resonator to GWs in the microwave range, using for the first time tools allowing to perform realistic simulations. Concretely, the BI-RME 3D method, which allows us to obtain not only the detected power but also the detected voltage (magnitude and phase), is used here. After analyzing three cubic cavities for different frequencies and working simultaneously with three different degenerate modes at each cavity, we conclude that the sensitivity of the experiment is strongly dependent on the polarization and incidence angle of the GW. The presented experiment can reach sensitivities up to $ 1 \cdot 10^{-19}$ at 100\, MHz, $ 2 \cdot 10^{-20}$ at 1\, GHz, and $ 6 \cdot 10^{-19}$ at 10\, GHz for optimal angles and polarizations, and where in all cases we assumed an integration time of $Δt = 1$ ms. These results provide a strong case for further develo** the use of cavities to detect GWs. Moreover, the possibility of analyzing the detected voltage (magnitude and phase) opens a new interferometric detection scheme based on the combination of the detected signals from multiple cavities.
△ Less
Submitted 17 June, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
-
A proposal for a low-frequency axion search in the 1-2 $μ$eV range and below with the BabyIAXO magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
J. Devlin,
A. Díaz-Morcillo,
D. Díez-Ibáñez,
B. Döbrich,
J. Galindo,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
Y. Gu,
L. Herwig,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
J. Miralda-Escudé,
J. Monzó-Cabrera,
P. Navarro,
J. R. Navarro-Madrid,
J. Redondo,
J. Reina-Valero
, et al. (5 additional authors not shown)
Abstract:
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential se…
▽ More
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential sensitivity to the axion-photon coupling $g_{aγ}$ down to values corresponding to the KSVZ model, in the (currently unexplored) mass range between 1 and 2$~μ$eV, after a total effective exposure of 440 days. This mass range is covered by the use of four differently dimensioned 5-meter-long cavities, equipped with a tuning mechanism based on inner turning plates. A setup like the one proposed would also allow an exploration of the same mass range for hidden photons coupled to photons. An additional complementary apparatus is proposed using LC circuits and exploring the low energy range ($\sim10^{-4}-10^{-1}~μ$eV). The setup includes a cryostat and cooling system to cool down the BabyIAXO bore down to about 5 K, as well as appropriate low-noise signal amplification and detection chain.
△ Less
Submitted 22 November, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Methods and restrictions to increase the volume of resonant rectangular-section haloscopes for detecting dark matter axions
Authors:
J. M. García-Barceló,
A. Álvarez Melcón,
A. Díaz-Morcillo,
B. Gimeno,
A. J. Lozano-Guerrero,
J. Monzo-Cabrera,
J. R. Navarro-Madrid,
P. Navarro
Abstract:
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explore…
▽ More
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explored: based on single cavities and based on multicavities. For both cases, possibilities for increasing the volume in long and/or tall structures are presented. For multicavities, 1D geometries are explored to optimize the space in the magnets. Also, 2D and 3D geometries are introduced as a first step for laying the foundations for the development of these kind of topologies. The results prove the usefulness of the developed methods, evidencing the ample room of improvement in rectangular haloscope designs nowadays. A factor of three orders of magnitude improvement in volume compared with a single cavity based on WR-90 standard waveguide is obtained with the design of a long and tall single cavity. Similar procedures have been applied for long and tall multicavities. Experimental measurements are shown for prototypes based on tall multicavities and 2D structures, demonstrating the feasibility of using these types of geometries to increase the volume in real haloscopes.
△ Less
Submitted 24 February, 2023; v1 submitted 21 February, 2023;
originally announced February 2023.
-
On the use of ferroelectric material in the detection of dark matter axions
Authors:
J. M. García Barceló,
A. Álvarez Melcón,
S. Arguedas Cuendis,
A. Díaz-Morcillo,
B. Gimeno,
A. Kanareykin,
A. J. Lozano-Guerrero,
P. Navarro,
W. Wuensch
Abstract:
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can…
▽ More
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can provide a path that is less vulnerable to mechanical failures and thus complements and expands current tuning systems. In this work, we present and design a novel concept for using the ferroelectric Potassium Tantalate ($KTaO_3$ or KTO) material as a tuning element in haloscopes based on coupled microwave cavities. In this line, the structures used in the Relic Axion Detector Exploratory Setup (RADES) group are based on several cavities that are connected by metallic irises, which act as interresonator coupling elements. In this article, we also show how to use these $KTaO_3$ films as interresonator couplings between cavities, instead of inductive or capacitive metallic windows used in the past. These two concepts represent a crucial upgrade over the current systems employed in the dark matter axions community, achieving a tuning range of $2.23 \, \%$ which represents a major improvement as compared to previous works ($<0.1 \, \%$) for the same class of tuning systems. The theoretical and simulated results shown in this work demonstrate the interest of the novel concepts proposed for the incorporation of this kind of ferroelectric media in multicavity resonant haloscopes in the search for dark matter axions.
△ Less
Submitted 7 December, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
Design of new resonant haloscopes in the search for the darkmatter axion: a review of the first steps in the RADES collaboration
Authors:
A. Díaz-Morcillo,
J. M. García Barceló,
A. J. Lozano-Guerrero,
P. Navarro,
B. Gimeno,
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
S. Calatroni,
B. Döbrich,
J. D. Gallego,
J. Golm,
I. G. Irastorza,
C. Malbrunot,
Jordi Miralda-Escudé,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs…
▽ More
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs, based on the multi-cavity concept, aiming to increase the haloscope volume and, so, to improve its sensitivity, their evolution, the data acquisition design, and, finally, the first experimental run. Moreover, the envisaged work within RADES, for both dipole and solenoid magnets, in the short and medium term is also presented.
△ Less
Submitted 22 January, 2022; v1 submitted 29 November, 2021;
originally announced November 2021.
-
Thin Film (High Temperature) Superconducting Radiofrequency Cavities for the Search of Axion Dark Matter
Authors:
J. Golm,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
B. Döbrich,
J. D. Gallego,
J. M. García Barceló,
X. Granados,
J. Gutierrez,
I. G. Irastorza,
T. Koettig,
N. Lamas,
J. Liberadzka-Porret,
C. Malbrunot,
W. L. Millar,
P. Navarro,
C. Pereira Carlos,
T. Puig,
G. J. Rosaz,
M. Siodlaczek,
G. Telles,
W. Wuensch
Abstract:
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 $μ$eV. The figure of merit of our detector depends linearly on the quali…
▽ More
The axion is a hypothetical particle which is a candidate for cold dark matter. Haloscope experiments directly search for these particles in strong magnetic fields with RF cavities as detectors. The Relic Axion Detector Exploratory Setup (RADES) at CERN in particular is searching for axion dark matter in a mass range above 30 $μ$eV. The figure of merit of our detector depends linearly on the quality factor of the cavity and therefore we are researching the possibility of coating our cavities with different superconducting materials to increase the quality factor. Since the experiment operates in strong magnetic fields of 11 T and more, superconductors with high critical magnetic fields are necessary. Suitable materials for this application are for example REBa$_2$Cu$_3$O$_{7-x}$, Nb$_3$Sn or NbN. We designed a microwave cavity which resonates at around 9~GHz, with a geometry optimized to facilitate superconducting coating and designed to fit in the bore of available high-field accelerator magnets at CERN. Several prototypes of this cavity were coated with different superconducting materials, employing different coating techniques. These prototypes were characterized in strong magnetic fields at 4.2 K.
△ Less
Submitted 9 February, 2022; v1 submitted 4 October, 2021;
originally announced October 2021.
-
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
Authors:
A. Samalan,
M. Tytgat,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. DaCosta,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal,
A. Cabrera
, et al. (86 additional authors not shown)
Abstract:
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen…
▽ More
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
△ Less
Submitted 2 November, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
CMS RPC Background -- Studies and Measurements
Authors:
R. Hadjiiska,
A. Samalan,
M. Tytgat,
N. Zaganidis,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. Da Costa,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal
, et al. (84 additional authors not shown)
Abstract:
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd…
▽ More
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.
△ Less
Submitted 13 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
zfit: scalable pythonic fitting
Authors:
Jonas Eschle,
Albert Puig Navarro,
Rafael Silva Coutinho,
Nicola Serra
Abstract:
Statistical modeling is a key element in many scientific fields and especially in High-Energy Physics (HEP) analysis. The standard framework to perform this task in HEP is the C++ ROOT/RooFit toolkit; with Python bindings that are only loosely integrated into the scientific Python ecosystem. In this paper, zfit, a new alternative to RooFit written in pure Python, is presented. Most of all, zfit pr…
▽ More
Statistical modeling is a key element in many scientific fields and especially in High-Energy Physics (HEP) analysis. The standard framework to perform this task in HEP is the C++ ROOT/RooFit toolkit; with Python bindings that are only loosely integrated into the scientific Python ecosystem. In this paper, zfit, a new alternative to RooFit written in pure Python, is presented. Most of all, zfit provides a well defined high-level API and workflow for advanced model building and fitting, together with an implementation on top of TensorFlow, allowing a transparent usage of CPUs and GPUs. It is designed to be extendable in a very simple fashion, allowing the usage of cutting-edge developments from the scientific Python ecosystem in a transparent way. The main features of zfit are introduced, and its extension to data analysis, especially in the context of HEP experiments, is discussed.
△ Less
Submitted 20 May, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
The 3 cavity prototypes of RADES, an axion detector using microwave filters at CAST
Authors:
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
B. Gimeno,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
P. Navarro,
C. Peña Garay,
J. Redondo,
T. Vafeiadis,
W. Wuensch
Abstract:
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectang…
▽ More
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectangular irises. The size of the sub-cavities determines the working frequency, the amount of sub-cavities determine the working volume. The first cavity prototype was built in 2017 to work at a frequency of $\sim$ 8.4 GHz and it was placed at the 9 T CAST dipole magnet at CERN. Two more prototypes were designed and built in 2018. The aim of the new designs is to find and test the best cavity geometry in order to scale up in volume and to introduce an effective tuning mechanism. Our results demonstrate the promising potential of this type of filter to reach QCD axion sensitivity at X-Band frequencies.
△ Less
Submitted 11 March, 2019;
originally announced March 2019.
-
Design and performance of the LHCb trigger and full real-time reconstruction in Run 2 of the LHC
Authors:
R. Aaij,
S. Akar,
J. Albrecht,
M. Alexander,
A. Alfonso Albero,
S. Amerio,
L. Anderlini,
P. d'Argent,
A. Baranov,
W. Barter,
S. Benson,
D. Bobulska,
T. Boettcher,
S. Borghi,
E. E. Bowen,
L. Brarda,
C. Burr,
J. -P. Cachemiche,
M. Calvo Gomez,
M. Cattaneo,
H. Chanal,
M. Chapman,
M. Chebbi,
M. Chefdeville,
P. Ciambrone
, et al. (116 additional authors not shown)
Abstract:
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run…
▽ More
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run 2. We describe the design of the Run 2 trigger and real-time reconstruction, and present data-driven performance measurements for a representative sample of LHCb's physics programme.
△ Less
Submitted 25 June, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
HEP Software Foundation Community White Paper Working Group - Training, Staffing and Careers
Authors:
HEP Software Foundation,
:,
Dario Berzano,
Riccardo Maria Bianchi,
Peter Elmer,
Sergei V. Gleyzer John Harvey,
Roger Jones,
Michel Jouvin,
Daniel S. Katz,
Sudhir Malik,
Dario Menasce,
Mark Neubauer,
Fernanda Psihas,
Albert Puig Navarro,
Graeme A. Stewart,
Christopher Tunnell,
Justin A. Vasel,
Sean-Jiun Wang
Abstract:
The rapid evolution of technology and the parallel increasing complexity of algorithmic analysis in HEP requires developers to acquire a much larger portfolio of programming skills. Young researchers graduating from universities worldwide currently do not receive adequate preparation in the very diverse fields of modern computing to respond to growing needs of the most advanced experimental challe…
▽ More
The rapid evolution of technology and the parallel increasing complexity of algorithmic analysis in HEP requires developers to acquire a much larger portfolio of programming skills. Young researchers graduating from universities worldwide currently do not receive adequate preparation in the very diverse fields of modern computing to respond to growing needs of the most advanced experimental challenges. There is a growing consensus in the HEP community on the need for training programmes to bring researchers up to date with new software technologies, in particular in the domains of concurrent programming and artificial intelligence. We review some of the initiatives under way for introducing new training programmes and highlight some of the issues that need to be taken into account for these to be successful.
△ Less
Submitted 17 January, 2019; v1 submitted 8 July, 2018;
originally announced July 2018.
-
A Roadmap for HEP Software and Computing R&D for the 2020s
Authors:
Johannes Albrecht,
Antonio Augusto Alves Jr,
Guilherme Amadio,
Giuseppe Andronico,
Nguyen Anh-Ky,
Laurent Aphecetche,
John Apostolakis,
Makoto Asai,
Luca Atzori,
Marian Babik,
Giuseppe Bagliesi,
Marilena Bandieramonte,
Sunanda Banerjee,
Martin Barisits,
Lothar A. T. Bauerdick,
Stefano Belforte,
Douglas Benjamin,
Catrin Bernius,
Wahid Bhimji,
Riccardo Maria Bianchi,
Ian Bird,
Catherine Biscarat,
Jakob Blomer,
Kenneth Bloom,
Tommaso Boccali
, et al. (285 additional authors not shown)
Abstract:
Particle physics has an ambitious and broad experimental programme for the coming decades. This programme requires large investments in detector hardware, either to build new facilities and experiments, or to upgrade existing ones. Similarly, it requires commensurate investment in the R&D of software to acquire, manage, process, and analyse the shear amounts of data to be recorded. In planning for…
▽ More
Particle physics has an ambitious and broad experimental programme for the coming decades. This programme requires large investments in detector hardware, either to build new facilities and experiments, or to upgrade existing ones. Similarly, it requires commensurate investment in the R&D of software to acquire, manage, process, and analyse the shear amounts of data to be recorded. In planning for the HL-LHC in particular, it is critical that all of the collaborating stakeholders agree on the software goals and priorities, and that the efforts complement each other. In this spirit, this white paper describes the R&D activities required to prepare for this software upgrade.
△ Less
Submitted 19 December, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.