The CLAS12 Backward Angle Neutron Detector (BAND)
Authors:
E. P. Segarra,
F. Hauenstein,
A. Schmidt,
A. Beck,
S. May-Tal Beck,
R. Cruz-Torres,
A. Denniston,
A. Hrnjic,
T. Kutz,
A. Nambrath,
J. R. Pybus,
K. Pryce,
C. Fogler,
T. Hartlove,
L. B. Weinstein,
J. Vega,
M. Ungerer,
H. Hakobyan,
W. K. Brooks,
E. Piasetzky,
E. Cohen,
M. Duer,
I. Korover,
J. Barlow,
E. Barriga
, et al. (3 additional authors not shown)
Abstract:
The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of $155^\circ$ to $175^\circ$, with momenta between $200$ and $600$ MeV/c. It is positioned 3 meters upstream of the target, consists of $18$ rows and $5$ layers of $7.2$ cm by $7.2$ cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers…
▽ More
The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of $155^\circ$ to $175^\circ$, with momenta between $200$ and $600$ MeV/c. It is positioned 3 meters upstream of the target, consists of $18$ rows and $5$ layers of $7.2$ cm by $7.2$ cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2 cm thick lead wall followed by a 2 cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than $250$ ps (150 ps) for energy depositions above 2 MeVee (5 MeVee). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. The time resolution results in a neutron momentum reconstruction resolution, $δp/p < 1.5$\% for neutron momentum $200\le p\le 600$ MeV/c. Final performance of the BAND with CLAS12 is shown, including electron-neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.
△ Less
Submitted 10 July, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.
Laser Calibration System for Time of Flight Scintillator Arrays
Authors:
A. Denniston,
E. P. Segarra,
A. Schmidt,
A. Beck,
S. May-Tal Beck,
R. Cruz-Torres,
F. Hauenstein,
A. Hrnjic,
T. Kutz,
A. Nambrath,
J. R. Pybus,
P. Toledo,
L. B. Weinstein,
M. Olivenboim,
E. Piasetzky,
I. Korover,
O. Hen
Abstract:
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neu…
▽ More
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.
△ Less
Submitted 21 May, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.