-
Response of negative ion beamlet to RF field in beam extraction region
Authors:
Kenichi Nagaoka,
Haruhisa Nakano,
Taiga Hamajima,
Ryoya Nakamoto,
Katsuyoshi Tsumori,
Masaki Osakabe,
Katsunori Ikeda,
Masashi Kisaki,
Kenji Miyamoto,
Kazunori Takahashi,
Ursel Fantz
Abstract:
Beam-focusing characteristics of negative ion beams have been experimentally investigated with a superimposition of a controlled perturbation of RF field in a filament-arc discharge negative ion source. Oscillations of a negative-ion beamlet width and axis responding to the RF perturbation were observed, which may be a cause of the larger beam divergence angle of the RF negative ion source for ITE…
▽ More
Beam-focusing characteristics of negative ion beams have been experimentally investigated with a superimposition of a controlled perturbation of RF field in a filament-arc discharge negative ion source. Oscillations of a negative-ion beamlet width and axis responding to the RF perturbation were observed, which may be a cause of the larger beam divergence angle of the RF negative ion source for ITER. It is pointed out that the oscillation of the beamlet width depends on the perveance and on the RF frequency such that the oscillation is suppressed at perveance-matched conditions and at low RF frequency.
△ Less
Submitted 25 December, 2023;
originally announced December 2023.
-
Theoretical examination of QED Hamiltonian and negative-energy orbitals in relativistic molecular orbital theory
Authors:
Nobuki Inoue,
Yoshihiro Watanabe,
Haruyuki Nakano
Abstract:
The relativistic Hartree-Fock and electron correlation methods without the negative-energy orbital problem are examined on the basis of the quantum electrodynamics (QED) Hamiltonian. First, several QED Hamiltonians previously proposed are sifted by the orbital rotation invariance, the charge conjugation and time reversal invariance, and the nonrelativistic limit. A new total energy expression is t…
▽ More
The relativistic Hartree-Fock and electron correlation methods without the negative-energy orbital problem are examined on the basis of the quantum electrodynamics (QED) Hamiltonian. First, several QED Hamiltonians previously proposed are sifted by the orbital rotation invariance, the charge conjugation and time reversal invariance, and the nonrelativistic limit. A new total energy expression is then proposed, in which a counter term corresponding to the energy of the polarized vacuum is subtracted from the total energy. This expression prevents the possibility of total energy divergence due to electron correlations, stemming from the fact that the QED Hamiltonian does not conserve the number of particles. Finally, based on the Hamiltonian and energy expression, the Dirac-Hartree-Fock (DHF) and electron correlation methods are reintroduced. The resulting QED-based DHF equation has the same form as the conventional DHF equation, but also formally describes systems specific to QED, such as the virtual positrons in the hydride ion and the positron in positronium. Three electron correlation methods are derived: the QED-based configuration interactions and single- and multireference perturbation methods. Numerical calculations show that the total energy of the QED Hamiltonian indeed diverges and that the counter term is effective in avoiding the divergence. The theoretical examinations in the present article suggest that the molecular orbital (MO) methods based on the QED Hamiltonian not only solve the problem of the negative-energy solutions of the relativistic MO method, but also provide a relativistic formalism to treat systems containing positrons.
△ Less
Submitted 29 December, 2022;
originally announced December 2022.
-
Origin of long-range order in a two-dimensional nonequilibrium system under laminar flows
Authors:
Yuki Minami,
Hiroyoshi Nakano
Abstract:
We study long-range order in two dimensions where an order parameter is advected by linear laminar flows. The linear laminar flows include three classes: rotational, shear, and elongational flows. Under these flows, we analyze an ordered state of the $O(N)$ scalar model in the large-$N$ limit. We show that the stability of the ordered state depends on the flow pattern; the shear and elongational f…
▽ More
We study long-range order in two dimensions where an order parameter is advected by linear laminar flows. The linear laminar flows include three classes: rotational, shear, and elongational flows. Under these flows, we analyze an ordered state of the $O(N)$ scalar model in the large-$N$ limit. We show that the stability of the ordered state depends on the flow pattern; the shear and elongational flows stabilize but the rotational flow does not. We discuss a physical interpretation of our results based on interaction representation in quantum mechanics. The origin of the long-range order is interpreted from the advection of wavenumbers along the streamlines and its stretching effect stabilizes the order.
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
Input optics systems of the KAGRA detector during O3GK
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
Z. Cao,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
C-I. Chiang,
H. Chu,
Y-K. Chu,
S. Eguchi
, et al. (228 additional authors not shown)
Abstract:
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensit…
▽ More
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Interaction between substrate and probe in liquid metal Ga: Experimental and theoretical analysis
Authors:
Ken-ichi Amano,
Kentaro Tozawa,
Maho Tomita,
Hiroshi Nakano,
Makoto Murata,
Yousuke Abe,
Toru Utsunomiya,
Hiroyuki Sugimura,
Takashi Ichii
Abstract:
Understanding the interaction between two bodies in a liquid metal is important for develo** metals with high stiffness, strength, plasticity, and thermal stability. We conducted atomic force microscopy measurements in liquid Ga and performed a theoretical calculation in which the statistical mechanics of a simple liquid containing a quantum effect was used. The experiment and theory showed unus…
▽ More
Understanding the interaction between two bodies in a liquid metal is important for develo** metals with high stiffness, strength, plasticity, and thermal stability. We conducted atomic force microscopy measurements in liquid Ga and performed a theoretical calculation in which the statistical mechanics of a simple liquid containing a quantum effect was used. The experiment and theory showed unusual behaviours in the interactions between the probe and substrate in the liquid metal. In the interactions, there were relatively numerous oscillations and large amplitudes. Furthermore, the interaction ranges were relatively long. From the theoretical calculations, we found an asymmetric property that when the probe is solvophilic and the substrate is solvophobic, the interaction tends to be repulsive; when the solvation affinities are exchanged, the interaction tends to be attractive in the close position. Our findings will be useful for understanding and controlling dispersion stabilities of nanoparticles and chemical reactions in liquid metals.
△ Less
Submitted 18 May, 2022;
originally announced May 2022.
-
Molecular dynamics study of shear-induced long-range correlations in simple fluids
Authors:
Hiroyoshi Nakano,
Yuki Minami
Abstract:
We investigate long-range correlations (LRCs) induced by shear flow using the molecular dynamics (MD) simulation. We observe the LRCs by comparing the MD results with the linearized fluctuating hydrodynamics (LFH). We find that the MD result has large finite-size effects, and it prevents the occurrence of LRCs in small systems. We examine the finite-size effects using a sufficiently large system c…
▽ More
We investigate long-range correlations (LRCs) induced by shear flow using the molecular dynamics (MD) simulation. We observe the LRCs by comparing the MD results with the linearized fluctuating hydrodynamics (LFH). We find that the MD result has large finite-size effects, and it prevents the occurrence of LRCs in small systems. We examine the finite-size effects using a sufficiently large system consisting of more than ten million particles, and verify the existence of shear-induced LRCs without ambiguity. Furthermore, we show that MD result is quantitatively consistent with the LFH solution for the large system. As we reduce the system size $L$ or increase the shear rate $\dotγ$, the hydrodynamic description gradually breaks down in the long-wavelength region. We define a characteristic wavenumber $k^{\rm vio}$ associated with the breakdown and find the nontrivial scaling relations $k^{\rm vio} \propto L^{-ω}$ and $k^{\rm vio} \propto \dotγ$, where $ω$ is an exponent depending on $\dotγ$. These relations enable us to estimate the finite-size effects in a larger-size simulation from a smaller system.
△ Less
Submitted 30 June, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
The Generalized Occupation-Restricted-Multiple-Active-Space Concept in Multiconfigurational Self-Consistent Field Methods
Authors:
Chen Yang,
Yoshihiro Watanabe,
Haruyuki Nakano
Abstract:
A novel concept of multiconfigurational self-consistent field method, the generalized occupation-restricted-multiple-active-space (GORMAS) is presented. GORMAS wave functions are defined by substituting the complete active space (CAS) in ORMAS, given a pre- or a post-restriction. The GORMAS approach shows a flexible selection of active space, reduce the ineffective reference configurations from CA…
▽ More
A novel concept of multiconfigurational self-consistent field method, the generalized occupation-restricted-multiple-active-space (GORMAS) is presented. GORMAS wave functions are defined by substituting the complete active space (CAS) in ORMAS, given a pre- or a post-restriction. The GORMAS approach shows a flexible selection of active space, reduce the ineffective reference configurations from CAS dramatically. Test calculations in molecule or complex systems, CH$_2$O, (H$_2$O)$_2$ molecule, and oxoMn(salen) are presented. They show the GORMAS wave functions achieve the similar accuracy with under 15\% dimension of reference spaces.
△ Less
Submitted 30 November, 2021;
originally announced November 2021.
-
Overview of KAGRA: Detector design and construction history
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. -W. Bae,
Y. -B. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. -L. Chan,
C. -S. Chen,
K. -H. Chen,
Y. -R. Chen,
H. -Y. Chu,
Y-K. Chu,
S. Eguchi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (175 additional authors not shown)
Abstract:
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA…
▽ More
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.
△ Less
Submitted 2 July, 2020; v1 submitted 12 May, 2020;
originally announced May 2020.
-
Equilibrium measurement method of slip length based on fluctuating hydrodynamics
Authors:
Hiroyoshi Nakano,
Shin-ichi Sasa
Abstract:
We perform equilibrium molecular dynamics simulations for nanoscale fluids confined between two parallel walls and investigate how the autocorrelation function of force acting on one wall is related to the slip length. We demonstrate that for atomically smooth surfaces, the autocorrelation function is accurately described by linearized fluctuating hydrodynamics (LFH). Excellent agreement between t…
▽ More
We perform equilibrium molecular dynamics simulations for nanoscale fluids confined between two parallel walls and investigate how the autocorrelation function of force acting on one wall is related to the slip length. We demonstrate that for atomically smooth surfaces, the autocorrelation function is accurately described by linearized fluctuating hydrodynamics (LFH). Excellent agreement between the simulation and the LFH solution is found over a wide range of scales, specifically, from the time scale of fluid relaxation even to that of molecular motion. Fitting the simulation data yields a reasonable estimation of the slip length. We show that LFH provides a starting point for examining the relationship between the slip length and the force fluctuations.
△ Less
Submitted 1 March, 2020; v1 submitted 9 October, 2019;
originally announced October 2019.
-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
Prospects for improving the sensitivity of KAGRA gravitational wave detector
Authors:
Yuta Michimura,
Masaki Ando,
Eleonora Capocasa,
Yutaro Enomoto,
Raffaele Flaminio,
Sadakazu Haino,
Kazuhiro Hayama,
Eiichi Hirose,
Yousuke Itoh,
Tomoya Kinugawa,
Kentro Komori,
Matteo Leonardi,
Norikatsu Mio,
Koji Nagano,
Hiroyuki Nakano,
Atsushi Nishizawa,
Norichika Sago,
Masaru Shibata,
Hisaaki Shinkai,
Kentaro Somiya,
Hiroki Takeda,
Takahiro Tanaka,
Satoshi Tanioka,
Li-Wei Wei,
Kazuhiro Yamamoto
Abstract:
KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the tes…
▽ More
KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the test mass mirrors. In this paper, investigations on the upgrade plans which can be realized by changing the input laser power, increasing the mirror mass, and injecting frequency dependent squeezed vacuum are presented. We show how each upgrade affects to the detector frequency bands and also discuss impacts on gravitational-wave science. We then propose an effective progression of upgrades based on technical feasibility and scientific scenarios.
△ Less
Submitted 6 June, 2019;
originally announced June 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Vibration isolation system with a compact dam** system for power recycling mirrors of KAGRA
Authors:
Y. Akiyama,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
V. Dattilo,
K. Doi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (149 additional authors not shown)
Abstract:
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main st…
▽ More
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient dam** performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the dam** performance, and also on estimated residual displacement of the optics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
Statistical mechanical expressions of slip length
Authors:
Hiroyoshi Nakano,
Shin-ichi Sasa
Abstract:
We provide general derivations of the partial slip boundary condition from microscopic dynamics and linearized fluctuating hydrodynamics. The derivations are based on the assumption of separation of scales between microscopic behavior, such as collision of particles, and macroscopic behavior, such as relaxation of fluid to global equilibrium. The derivations lead to several statistical mechanical…
▽ More
We provide general derivations of the partial slip boundary condition from microscopic dynamics and linearized fluctuating hydrodynamics. The derivations are based on the assumption of separation of scales between microscopic behavior, such as collision of particles, and macroscopic behavior, such as relaxation of fluid to global equilibrium. The derivations lead to several statistical mechanical expressions of the slip length, which are classified into two types. The expression in the first type is given as a local transport coefficient, which is related to the linear response theory that describes the relaxation process of the fluid. The second type is related to the linear response theory that describes the non-equilibrium steady state and the slip length is given as combination of global transport coefficients, which are dependent on macroscopic lengths such as a system size. Our derivations clarify that the separation of scales must be seriously considered in order to distinguish the expressions belonging to two types. Based on these linear response theories, we organize the relationship among the statistical mechanical expressions of the slip length suggested in previous studies.
△ Less
Submitted 27 March, 2019; v1 submitted 16 November, 2018;
originally announced November 2018.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
The status of KAGRA underground cryogenic gravitational wave telescope
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
M. A. Barton,
K. Cannon,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
Y. Fujii,
M. -K. Fujimoto,
T. Furuhata,
S. Haino,
K. Hasegawa,
K. Hashino,
K. Hayama,
S. Hirobayashi
, et al. (126 additional authors not shown)
Abstract:
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial ph…
▽ More
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial phase operation of the interferometer with a simple 3-km Michelson configuration have been completed. The first cryogenic operation is expected in 2018, and the observing runs with a full interferometer are expected in 2020s. The basic interferometer configuration and the current status of KAGRA are described.
△ Less
Submitted 13 October, 2017;
originally announced October 2017.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.