-
Circular polarization measurement for individual gamma rays in capture reactions with intense pulsed neutrons
Authors:
S. Endo,
R. Abe,
H. Fujioka,
T. Ino,
O. Iwamoto,
N. Iwamoto,
S. Kawamura,
A. Kimura,
M. Kitaguchi,
R. Kobayashi,
S. Nakamura,
T. Oku T. Okudaira,
M. Okuizumi,
M. Omer,
G. Rovira,
T. Shima,
H. M. Shimizu,
T. Shizuma,
Y. Taira,
S. Takada,
S. Takahashi,
H. Yoshikawa,
T. Yoshioka,
H. Zen
Abstract:
Measurements of circular polarization of $γ$-ray emitted from neutron capture reactions provide valuable information for nuclear physics studies. The spin and parity of excited states can be determined by measuring the circular polarization from polarized neutron capture reactions. Furthermore, the $γ$-ray circular polarization in a neutron capture resonance is crucial for studying the enhancement…
▽ More
Measurements of circular polarization of $γ$-ray emitted from neutron capture reactions provide valuable information for nuclear physics studies. The spin and parity of excited states can be determined by measuring the circular polarization from polarized neutron capture reactions. Furthermore, the $γ$-ray circular polarization in a neutron capture resonance is crucial for studying the enhancement effect of parity nonconservation in compound nuclei. The $γ$-ray circular polarization can be measured using a polarimeter based on magnetic Compton scattering. A polarimeter was constructed, and its performance indicators were evaluated using a circularly polarized $γ$-ray beam. Furthermore, as a demonstration, the $γ$-ray circular polarization was measured in $^{32}$S($\vec{\textrm{n}}$,$γ$)$^{33}$S reactions with polarized neutrons.
△ Less
Submitted 7 May, 2024;
originally announced June 2024.
-
A beam profile monitor for GeV photon with high spatial resolution and fast readout capability
Authors:
Ryoko Kino,
Takeru Akiyama,
Hiroyuki Fujioka,
Tomomasa Fujiwara,
Tatsuhiro Ishige,
Kosuke Itabashi,
Shunsuke Kajikawa,
Masashi Kaneta,
Masaya Mizuno,
Sho Nagao,
Satoshi N. Nakamura,
Kotaro Nishi,
Ken Nishida,
Kazuki Okuyama,
Fumiya Oura,
Koga Tachibana,
Yuichi Toyama,
Daigo Watanabe
Abstract:
A beam profile monitor (BPM) has been developed to measure photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARIS-Mikamine; previously known as ELPH) at Tohoku University. The BPM comprises plastic scintillation fibers and SiPMs, enabling high-precision, real-time measurements of photon beams in the 1 GeV region. Data acquisition util…
▽ More
A beam profile monitor (BPM) has been developed to measure photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARIS-Mikamine; previously known as ELPH) at Tohoku University. The BPM comprises plastic scintillation fibers and SiPMs, enabling high-precision, real-time measurements of photon beams in the 1 GeV region. Data acquisition utilized streaming TDC, a firmware commonly employed in the J-PARC Hadron-hall, enabling real-time detection of high-intensity photon beams with count rates reaching several tens of MHz. With sufficient statistical data, the BPM achieved a 1 s beam-profiling accuracy of 10 μm. The proposed BPM serves as a valuable resource for future physics experiments at the BM4 photon beamline and will contribute significantly to ongoing accelerator research endeavors.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Angular correlation of the two gamma rays produced in the thermal neutron capture on gadolinium-155 and gadolinium-157
Authors:
Pierre Goux,
Franz Glessgen,
Enrico Gazzola,
Mandeep Singh Reen,
William Focillon,
Michel Gonin,
Tomoyuki Tanaka,
Kaito Hagiwara,
Ajmi Ali,
Takashi Sudo,
Yusuke Koshio,
Makoto Sakuda,
Gianmaria Collazuol,
Atsushi Kimura,
Shoji Nakamura,
Nobuyuki Iwamoto,
Hideo Harada,
Michael Wurm
Abstract:
The ANNRI-Gd collaboration studied in detail the single $γ$-ray spectrum produced from the thermal neutron capture on $^{155}$Gd and $^{157}$Gd in our previous publications. Gadolinium targets were exposed to a neutron beam provided by the Japan Spallation Neutron Source (JSNS) in J-PARC, Japan. In the present analysis, one new additional coaxial germanium crystal was used in the analysis in combi…
▽ More
The ANNRI-Gd collaboration studied in detail the single $γ$-ray spectrum produced from the thermal neutron capture on $^{155}$Gd and $^{157}$Gd in our previous publications. Gadolinium targets were exposed to a neutron beam provided by the Japan Spallation Neutron Source (JSNS) in J-PARC, Japan. In the present analysis, one new additional coaxial germanium crystal was used in the analysis in combination with the fourteen germanium crystals in the cluster detectors to study the angular correlation of the two $γ$ rays emitted in the same neutron capture. We present for the first time angular correlation functions for two $γ$ rays produced during the electromagnetic cascade transitions in the (n, $γ$) reactions on $^{\rm 155}$Gd and $^{\rm 157}$Gd. As expected, we observe the mild angular correlations for the strong, but rare transitions from the resonance state to the two energy levels of known spin-parities. Contrariwise, we observe negligibly small angular correlations for arbitrary pairs of two $γ$ rays produced in the majority of cascade transitions from the resonance state to the dense continuum states.
△ Less
Submitted 26 April, 2023; v1 submitted 17 March, 2023;
originally announced March 2023.
-
Bulk-scale synthesis of randomly stacked graphene with high crystallinity
Authors:
Zizhao Xu,
Shingo Nakamura,
Taiki Inoue,
Yuta Nishina,
Yoshihiro Kobayashi
Abstract:
Since the strong interlayer interaction of AB-stacked graphene in bulk form degrades the superior property of single-layer graphene, formation of randomly stacked graphene is required to apply the high performances of graphene to macroscopic devices. However, conventional methods to obtain bulk-scale graphene suffer from a low crystallinity and/or the formation of a thermodynamically stable AB-sta…
▽ More
Since the strong interlayer interaction of AB-stacked graphene in bulk form degrades the superior property of single-layer graphene, formation of randomly stacked graphene is required to apply the high performances of graphene to macroscopic devices. However, conventional methods to obtain bulk-scale graphene suffer from a low crystallinity and/or the formation of a thermodynamically stable AB-stacked structure. This study develops a novel approach to produce bulk-scale graphene with a high crystallinity and high fractions of random stacking by utilizing the porous morphology of a graphene oxide sponge and an ultrahigh temperature treatment of 1500-1800 °C with ethanol vapor. Raman spectroscopy indicates that the obtained bulk-scale graphene sponge possesses a high crystallinity and a high fraction of random stacking of 80%. The large difference in the random-stacking ratio between the sponge and the aggregate samples confirms the importance of accessibility of ethanol-derived species into the internal area. By investigating the effect of treatment temperature, a higher random-stacking ratio is obtained at 1500 °C. Moreover, the AB-stacking fraction was reduced to less than 10% by introducing cellulose nanofiber as a spacer to prevent direct stacking of graphene. The proposed method is effective for large-scale production of high-performance bulk-scale graphene.
△ Less
Submitted 22 February, 2023; v1 submitted 21 February, 2023;
originally announced February 2023.
-
High accuracy synchrotron radiation interferometry with relativistic electrons
Authors:
P. Klag,
P. Achenbach,
T. Akiyama,
R. Böhm,
M. O. Distler,
L. Doria,
P. Eckert,
A. Esser,
J. Geratz,
T. Gogami,
C. Helmel,
P. Herrmann,
M Hoek,
M. Kaneta,
Y. Konishi,
R. Kino,
W. Lauth,
H. Merkel,
M. Mizuno,
U. Müller,
S. Nagao,
S. N. Nakamura,
K. Okuyama,
J. Pochodzalla,
B. S. Schlimme
, et al. (6 additional authors not shown)
Abstract:
A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method…
▽ More
A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method will be applied. In this contribution the basic principle of this method is discussed and the analysis status of the measured synchrotron radiation spectra is presented
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
Advanced Radio Frequency Timing AppaRATus (ARARAT) Technique and Applications
Authors:
Ani Aprahamian,
Amur Margaryan,
Vanik Kakoyan,
Simon Zhamkochyan,
Sergey Abrahamyan,
Hayk Elbakyan,
Samvel Mayilyan,
Arpine Piloyan,
Henrik Vardanyan,
Hamlet Zohrabyan,
Lekdar Gevorgian,
Robert Ayvazyan,
Artashes Papyan,
Garnik Ayvazyan,
Arsen Ghalumyan,
Narek Margaryan,
Hasmik Rostomyan,
Anna Safaryan,
Bagrat Grigoryan,
Ashot Vardanyan,
Arsham Yeremyan,
John Annand,
Kenneth Livingston,
Rachel Montgomery,
Patrick Achenbach
, et al. (6 additional authors not shown)
Abstract:
The development of the advanced Radio Frequency Timer of electrons is described. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, bas…
▽ More
The development of the advanced Radio Frequency Timer of electrons is described. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial slow readout system. Here, we report a device, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses which can be processed by using regular fast electronics. A photon sensor based on this technique, the Radio Frequency Photo-Multiplier Tube (RFPMT), has demonstrated a timing resolution of ~10 ps and a time stability of ~0.5 ps, FWHM. This makes the apparatus highly suited for Time Correlated Single Photon Counting which is widely used in optical microscopy and tomography of biological samples. The first application in lifetime measurements of quantum states of graphene, under construction at the A. I. Alikhanyan National Science Laboratory (AANL), is outlined. This is followed by a description of potential RFPMT applications in time-correlated Diffuse Optical Tomography, time-correlated Stimulated Emission Depletion microscopy, hybrid FRET/STED nanoscopy and Time-of-Flight Positron Emission Tomography.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Search for neutrinoless quadruple beta decay of $^{136}$Xe in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens
, et al. (12 additional authors not shown)
Abstract:
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was obser…
▽ More
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experimental constraint of the neutrinoless quadruple beta decay of $^{136}$Xe.
△ Less
Submitted 5 August, 2022; v1 submitted 10 May, 2022;
originally announced May 2022.
-
An RF Timer of Electrons and Photons with the Potential to reach Picosecond Precision
Authors:
Amur Margaryan,
Vanik Kakoyan,
Simon Zhamkochyan,
Sergey Abrahamyan,
Hayk Elbakyan,
Samvel Mayilyan,
Henrik Vardanyan,
Hamlet Zohrabyan,
Lekdar Gevorgian,
Robert Ayvazyan,
Artashes Papyan,
Garnik Ayvazyan,
Bagrat Grigoryan,
John Annand,
Kenneth Livingston,
Rachel Montgomery,
Patrick Achenbach,
Josef Pochodzalla,
Dimiter L. Balabanski,
Satoshi N. Nakamura
Abstract:
This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on s…
▽ More
This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial dead time associated with the readout system. Here, we report a new type of RF timing technique, where the position sensor, consisting of microchannel plates and a delay-line anode, produces ~ns duration pulses with small dead time. Measurements made with sub-ps duration laser pulses, synchronized to the radio frequency power, produced a timing resolution of ~10 ps. This ultra-high precision technique has potential applications in a large variety of scientific devices, and in all cases, electrons are timed and detected simultaneously in the same device.
△ Less
Submitted 20 May, 2022; v1 submitted 17 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Systematic treatment of hypernuclear data and application to the hypertriton
Authors:
P. Eckert,
P. Achenbach,
M. Aragones Fontbote,
T. Akiyama,
M. O. Distler,
A. Esser,
J. Geratz,
M. Hoek,
K. Itabashi,
M. Kaneta,
R. Kino,
P. Klag,
H. Merkel,
M. Mizuno,
J. Müller,
U. Müller,
S. Nagao,
S. N. Nakamura,
Y. R. Nakamura,
K. Okuyama,
J. Pochodzalla,
B. S. Schlimme,
C. Sfienti,
R. Spreckels,
M. Steinen
, et al. (4 additional authors not shown)
Abstract:
A database is under construction to provide a complete collection of published basic properties of hypernuclei such as Λ binding energies, lifetimes, or excitation energies. From these values, averages with related errors are computed in a systematic way. For each property, the overall experimental situation is depicted in form of an ideogram showing the combined probability density function of th…
▽ More
A database is under construction to provide a complete collection of published basic properties of hypernuclei such as Λ binding energies, lifetimes, or excitation energies. From these values, averages with related errors are computed in a systematic way. For each property, the overall experimental situation is depicted in form of an ideogram showing the combined probability density function of the measurements. The database is accessible via a dynamic website at https://hypernuclei.kph.uni-mainz.de with an user interface offering customizable visualizations, selections, or unit conversions. The capabilities of the database are demonstrated for the puzzling and disputed data situation of the hypertriton.
△ Less
Submitted 7 January, 2022;
originally announced January 2022.
-
Extension of the J-PARC Hadron Experimental Facility: Third White Paper
Authors:
Kazuya Aoki,
Hiroyuki Fujioka,
Toshiyuki Gogami,
Yoshimasa Hidaka,
Emiko Hiyama,
Ryotaro Honda,
Atsushi Hosaka,
Yudai Ichikawa,
Masaharu Ieiri,
Masahiro Isaka,
Noriyoshi Ishii,
Takatsugu Ishikawa,
Yusuke Komatsu,
Takeshi Komatsubara,
GeiYoub Lim,
Koji Miwa,
Yuhei Morino,
Tomofumi Nagae,
Sho Nagao,
Satoshi N. Nakamura,
Hajime Nanjo,
Megumi Naruki,
Hidekatsu Nemura,
Tadashi Nomura,
Hiroyuki Noumi
, et al. (18 additional authors not shown)
Abstract:
The J-PARC Hadron Experimental Facility was constructed with an aim to explore the origin and evolution of matter in the universe through the experiments with intense particle beams. In the past decade, many results on particle and nuclear physics have been obtained at the present facility. To expand the physics programs to unexplored regions never achieved, the extension project of the Hadron Exp…
▽ More
The J-PARC Hadron Experimental Facility was constructed with an aim to explore the origin and evolution of matter in the universe through the experiments with intense particle beams. In the past decade, many results on particle and nuclear physics have been obtained at the present facility. To expand the physics programs to unexplored regions never achieved, the extension project of the Hadron Experimental Facility has been extensively discussed. This white paper presents the physics of the extension of the Hadron Experimental Facility for resolving the issues in the fields of the strangeness nuclear physics, hadron physics, and flavor physics.
△ Less
Submitted 9 October, 2021;
originally announced October 2021.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Tamm plasmons in metal/nanoporous GaN distributed Bragg reflector cavities for active and passive optoelectronics
Authors:
Guillaume Lheureux,
Morteza Monavarian,
Ryan Anderson,
Ryan A. DeCrescent,
Joel Bellessa,
Clementine Symonds,
Jon A. Schuller,
Shuji Nakamura,
James S. Speck,
Steven P. DenBaars
Abstract:
We investigate Tamm plasmon (TP) modes in a metal/semiconductor distributed Bragg reflector (DBR) interface. A thin Ag (silver) layer with an optimized thickness (~ 55 nm from simulation) was deposited on nanoporous GaN DBRs fabricated using electrochemical etching on freestanding semipolar GaN substrates. The reflectivity spectra of the DBRs are compared before and after the Ag deposition and wit…
▽ More
We investigate Tamm plasmon (TP) modes in a metal/semiconductor distributed Bragg reflector (DBR) interface. A thin Ag (silver) layer with an optimized thickness (~ 55 nm from simulation) was deposited on nanoporous GaN DBRs fabricated using electrochemical etching on freestanding semipolar GaN substrates. The reflectivity spectra of the DBRs are compared before and after the Ag deposition and with that of a blanket Ag layer deposited on GaN. The results indicate presence of a TP mode at ~ 455 nm on the structure after the Ag deposition. An active medium can also be accommodated within the mode for optoelectronics and photonics. Moreover, the simulation results predict a sensitivity of the TP mode wavelength to the ambient (~ 4 nm shift when changing the ambient within the pores from air with n = 1 to isopropanol n = 1.3) , suggesting an application of the nanoporous GaN based TP structure for optical sensing.
△ Less
Submitted 5 January, 2020;
originally announced January 2020.
-
Gamma Ray Spectra from Thermal Neutron Capture on Gadolinium-155 and Natural Gadolinium
Authors:
Tomoyuki Tanaka,
Kaito Hagiwara,
Enrico Gazzola,
Takashi Sudo,
Mandeep Singh Reen,
Ajmi Ali,
Iwa Ou,
Rohit Dhir,
Pretam Kumar Das,
Yusuke Koshio,
Makoto Sakuda,
Atsushi Kimura,
Shoji Nakamura,
Nobuyuki Iwamoto,
Hideo Harada,
Gianmaria Collazuol,
Sebastian Lorenz,
Michael Wurm,
William Focillon,
Michel Gonin,
Takatomi Yano
Abstract:
Natural gadolinium is widely used for its excellent thermal neutron capture cross section, because of its two major isotopes: $^{\rm 155}$Gd and $^{\rm 157}$Gd. We measured the $γ$-ray spectra produced from the thermal neutron capture on targets comprising a natural gadolinium film and enriched $^{\rm 155}$Gd (in Gd$_{2}$O$_{3}$ powder) in the energy range from 0.11 MeV to 8.0 MeV, using the ANNRI…
▽ More
Natural gadolinium is widely used for its excellent thermal neutron capture cross section, because of its two major isotopes: $^{\rm 155}$Gd and $^{\rm 157}$Gd. We measured the $γ$-ray spectra produced from the thermal neutron capture on targets comprising a natural gadolinium film and enriched $^{\rm 155}$Gd (in Gd$_{2}$O$_{3}$ powder) in the energy range from 0.11 MeV to 8.0 MeV, using the ANNRI germanium spectrometer at MLF, J-PARC. The freshly analysed data of the $^{\rm 155}$Gd(n, $γ$) reaction are used to improve our previously developed model (ANNRI-Gd model) for the $^{\rm 157}$Gd(n, $γ$) reaction, and its performance confirmed with the independent data from the $^{\rm nat}$Gd(n, $γ$) reaction. This article completes the development of an efficient Monte Carlo model required to simulate and analyse particle interactions involving the thermal neutron captures on gadolinium in any relevant future experiments.
△ Less
Submitted 1 February, 2020; v1 submitted 28 June, 2019;
originally announced July 2019.
-
Unidirectional Luminescence from Quantum Well Metasurfaces
Authors:
Prasad P. Iyer,
Ryan A. DeCrescent,
Nikita A. Butakov,
Abdullah Alhassan,
Guillaume Lheureux,
Claude Weisbuch,
Shuji Nakamura,
Steven P. DenBaars,
Jon. A. Schuller
Abstract:
III-Nitride light emitting diodes (LEDs) are the backbone of ubiquitous lighting and display applications. Imparting directional emission is an essential requirement for many LED implementations. Although optical packaging, nano-patterning and surface roughening techniques can enhance LED extraction, directing the emitted light requires bulky optical components. Optical metasurfaces provide precis…
▽ More
III-Nitride light emitting diodes (LEDs) are the backbone of ubiquitous lighting and display applications. Imparting directional emission is an essential requirement for many LED implementations. Although optical packaging, nano-patterning and surface roughening techniques can enhance LED extraction, directing the emitted light requires bulky optical components. Optical metasurfaces provide precise control over transmitted and reflected waveforms, suggesting a new route for directing light emission. However, it is difficult to adapt metasurface concepts for incoherent light emission, due to the lack of a phase-locking incident wave. In this Letter, we demonstrate metasurface-based design of InGaN/GaN quantum-well structures that generate narrow, unidirectional transmission and emission lobes at arbitrary engineered angles. We show that the directions and polarization of emission differ significantly from transmission, in agreement with an analytical Local Density of Optical States (LDOS) model. The results presented in this Letter open a new paradigm for exploiting metasurface functionality in light emitting devices.
△ Less
Submitted 6 May, 2019;
originally announced May 2019.
-
Fabrication technology for high light-extraction ultraviolet thin-film flip-chip (UV TFFC) LEDs grown on SiC
Authors:
Burhan K. SaifAddin,
Abdullah Almogbel,
Christian J. Zollner,
Humberto Foronda,
Ahmed Alyamani,
Abdulrahman Albadri,
Michael Iza,
Shuji Nakamura,
Steven P. DenBaars,
James S. Speck
Abstract:
The light output of deep ultraviolet (UV-C) AlGaN light-emitting diodes (LEDs) is limited due to their poor light extraction efficiency (LEE). To improve the LEE of AlGaN LEDs, we developed a fabrication technology to process AlGaN LEDs grown on SiC into thin-film flip-chip LEDs (TFFC LEDs) with high LEE. This process transfers the AlGaN LED epi onto a new substrate by wafer-to-wafer bonding, and…
▽ More
The light output of deep ultraviolet (UV-C) AlGaN light-emitting diodes (LEDs) is limited due to their poor light extraction efficiency (LEE). To improve the LEE of AlGaN LEDs, we developed a fabrication technology to process AlGaN LEDs grown on SiC into thin-film flip-chip LEDs (TFFC LEDs) with high LEE. This process transfers the AlGaN LED epi onto a new substrate by wafer-to-wafer bonding, and by removing the absorbing SiC substrate with a highly selective SF6 plasma etch that stops at the AlN buffer layer. We optimized the inductively coupled plasma (ICP) SF6 etch parameters to develop a substrate-removal process with high reliability and precise epitaxial control, without creating micromasking defects or degrading the health of the plasma etching system. The SiC etch rate by SF6 plasma was ~46 μm/hr at a high RF bias (400 W), and ~7 μm/hr at a low RF bias (49 W) with very high etch selectivity between SiC and AlN. The high SF6 etch selectivity between SiC and AlN was essential for removing the SiC substrate and exposing a pristine, smooth AlN surface. We demonstrated the epi-transfer process by fabricating high light extraction TFFC LEDs from AlGaN LEDs grown on SiC. To further enhance the light extraction, the exposed N-face AlN was anisotropically etched in dilute KOH. The LEE of the AlGaN LED improved by ~3X after KOH roughening at room temperature. This AlGaN TFFC LED process establishes a viable path to high external quantum efficiency (EQE) and power conversion efficiency (PCE) UV-C LEDs.
△ Less
Submitted 3 December, 2018;
originally announced December 2018.
-
Precision beam energy measurement by undulator radiation at MAMI
Authors:
P. Klag,
P. Achenbach,
M. Biroth,
T. Gogami,
P. Herrmann,
M. Kaneta,
Y. Konishi,
W. Lauth,
S. Nagao,
S. N. Nakamura,
J. Pochodzalla,
J. Roser,
Y. Toyama
Abstract:
A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effects have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises…
▽ More
A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effects have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises a description of the method and results of the recent data taking period.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
Novel optical interferometry of synchrotron radiation for absolute electron beam energy measurements
Authors:
P. Klag,
P. Achenbach,
M. Biroth,
T. Gogami,
P. Herrmann,
M. Kaneta,
Y. Konishi,
W. Lauth,
S. Nagao,
S. N. Nakamura,
J. Pochodzalla,
J. Roser,
Y. Toyama
Abstract:
A novel interferometric method is presented for the measurement of the absolute energy of electron beams. In the year 2016, a pioneering experiment was performed using a 195 MeV beam of the Mainz Microtron (MAMI). The experimental setup consisted of two collinear magnetic undulators as sources of coherent optical synchrotron light and a high-resolving grating monochromator. Beam energy measurement…
▽ More
A novel interferometric method is presented for the measurement of the absolute energy of electron beams. In the year 2016, a pioneering experiment was performed using a 195 MeV beam of the Mainz Microtron (MAMI). The experimental setup consisted of two collinear magnetic undulators as sources of coherent optical synchrotron light and a high-resolving grating monochromator. Beam energy measurements required the variation of the relative undulator distance in the decimeter range and the analysis of the intensity oscillation length in the interference spectrum. A statistical precision of 1 keV was achieved in 1 hour of data taking, while systematic uncertainties of 700 keV were present in the experiment. These developments aim for a relative precision of $10^{-5}$ in the absolute momentum calibrations of spectrometers and high-precision hypernuclear experiments. Other electron accelerators with beam energies in this regime such as the Mainz Energy Recovering Superconducting Accelerator (MESA) might benefit from this new method.
△ Less
Submitted 19 September, 2018;
originally announced September 2018.
-
A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) an…
▽ More
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe.
$^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.
△ Less
Submitted 24 December, 2018; v1 submitted 16 September, 2018;
originally announced September 2018.
-
Gamma Ray Spectrum from Thermal Neutron Capture on Gadolinium-157
Authors:
Kaito Hagiwara,
Takatomi Yano,
Tomoyuki Tanaka,
Pretam Kumar Das,
Sebastian Lorenz,
Iwa Ou,
Takashi Sudo,
Mandeep Singh Reen,
Yoshiyuki Yamada,
Takaaki Mori,
Tsubasa Kayano,
Rohit Dir,
Yusuke Koshio,
Makoto Sakuda,
Atsushi Kimura,
Shoji Nakamura,
Nobuyuki Iwamoto,
Hideo Harada,
Michael Wurm,
William Focillon,
Michel Gonin,
Ajmi Ali,
Gianmaria Collazuol
Abstract:
We have measured the $γ$-ray energy spectrum from the thermal neutron capture, ${}^{157}$Gd$(n,γ){}^{158}$Gd, on an enriched $^{157}$Gd target (Gd$_{2}$O$_{3}$) in the energy range from 0.11 MeV up to about 8 MeV. The target was placed inside the germanium spectrometer of the ANNRI detector at J-PARC and exposed to a neutron beam from the Japan Spallation Neutron Source (JSNS). Radioactive sources…
▽ More
We have measured the $γ$-ray energy spectrum from the thermal neutron capture, ${}^{157}$Gd$(n,γ){}^{158}$Gd, on an enriched $^{157}$Gd target (Gd$_{2}$O$_{3}$) in the energy range from 0.11 MeV up to about 8 MeV. The target was placed inside the germanium spectrometer of the ANNRI detector at J-PARC and exposed to a neutron beam from the Japan Spallation Neutron Source (JSNS). Radioactive sources ($^{60}$Co, $^{137}$Cs, and $^{152}$Eu) and the reaction $^{35}$Cl($n$,$γ$) were used to determine the spectrometer's detection efficiency for $γ$ rays at energies from 0.3 to 8.5 MeV. Using a Geant4-based Monte Carlo simulation of the detector and based on our data, we have developed a model to describe the $γ$-ray spectrum from the thermal ${}^{157}$Gd($n$,$γ$) reaction. While we include the strength information of 15 prominent peaks above 5 MeV and associated peaks below 1.6 MeV from our data directly into the model, we rely on the theoretical inputs of nuclear level density and the photon strength function of ${}^{158}$Gd to describe the continuum $γ$-ray spectrum from the ${}^{157}$Gd($n$,$γ$) reaction. Our model combines these two components. The results of the comparison between the observed $γ$-ray spectra from the reaction and the model are reported in detail.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
Evaluation of the duty ratio of bacterial flagellar motor by a dynamic load control
Authors:
Kento Sato,
Shuichi Nakamura,
Seishi Kudo,
Shoichi Toyabe
Abstract:
Bacterial flagellar motor is one of the most complex and sophisticated nano machineries in nature. A duty ratio $D$ is a fraction of time that the stator and the rotor interact and is a fundamental property to characterize the motor but remains to be determined. It is known that the stator units of the motor bind to and dissociate from the motor dynamically to control the motor torque depending on…
▽ More
Bacterial flagellar motor is one of the most complex and sophisticated nano machineries in nature. A duty ratio $D$ is a fraction of time that the stator and the rotor interact and is a fundamental property to characterize the motor but remains to be determined. It is known that the stator units of the motor bind to and dissociate from the motor dynamically to control the motor torque depending on the load on the motor. At low load where the kinetics such as a proton translocation speed limits the rotation rate, the dependency of the rotation rate on the number of stator units $N$ infers $D$; the dependency becomes larger for smaller $D$. Contradicting observations supporting both the small and large $D$ have been reported. A dilemma is that it is difficult to explore a broad range of $N$ at low load because the stator units easily dissociate, and $N$ is limited to one or two at vanishing load. Here, we develop an electrorotation method to dynamically control the load on the flagellar motor of {\it Salmonella} with a calibrated magnitude of the torque. By instantly reducing the load for kee** $N$ high, we observed that the speed at low load depends on $N$, implying a small duty ratio. We recovered the torque-speed curves of individual motors and evaluated the duty ratio to be $0.14 \pm 0.04$ from the correlation between the torque at high load and the rotation rate at low load.
△ Less
Submitted 25 February, 2019; v1 submitted 17 June, 2018;
originally announced June 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant sig…
▽ More
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.
△ Less
Submitted 16 April, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Design and Performance of the Spin Asymmetries of the Nucleon Experiment
Authors:
J. D. Maxwell,
W. R. Armstrong,
S. Choi,
M. K. Jones,
H. Kang,
A. Liyanage,
Z. -E. Meziani,
J. Mulholland,
L. Ndukum,
O. A. Rondon,
A. Ahmidouch,
I. Albayrak,
A. Asaturyan,
O. Ates,
H. Baghdasaryan,
W. Boeglin,
P. Bosted,
E. Brash,
J. Brock,
C. Butuceanu,
M. Bychkov,
C. Carlin,
P. Carter,
C. Chen,
J. -P. Chen
, et al. (80 additional authors not shown)
Abstract:
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employin…
▽ More
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target whose magnetic field direction could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables $A_1$, $A_2$, $g_1$, $g_2$ and moment $d_2$ of the proton. This document summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.
△ Less
Submitted 21 December, 2017; v1 submitted 22 November, 2017;
originally announced November 2017.
-
Neutral Kaon Spectrometer 2
Authors:
M. Kaneta,
B. Beckford,
T. Fujii Y. Fujii K. Futatsukawa Y. C. Han O. Hashimoto,
K. Hirose,
T. Ishikawa,
H. Kanda,
C. Kimura,
K Maeda,
S. N. Nakamura,
K. Suzuki,
K. Tsukada,
F. Yamamoto,
H. Yamazaki
Abstract:
A large-acceptance spectrometer, Neutral Kaon Spectrometer 2 (NKS2), was newly constructed to explore various photoproduction reactions in the gigaelectronvolt region at the Laboratory of Nuclear Science (LNS, currently ELPH), Tohoku University. The spectrometer consisted of a dipole magnet, drift chambers, and plastic scintillation counters. NKS2 was designed to separate pions and protons in a mo…
▽ More
A large-acceptance spectrometer, Neutral Kaon Spectrometer 2 (NKS2), was newly constructed to explore various photoproduction reactions in the gigaelectronvolt region at the Laboratory of Nuclear Science (LNS, currently ELPH), Tohoku University. The spectrometer consisted of a dipole magnet, drift chambers, and plastic scintillation counters. NKS2 was designed to separate pions and protons in a momentum range of less than 1 GeV/$c$, and was placed in a tagged photon beamline. A cryogenic H$_{2}$/D$_{2}$ target fitted to the spectrometer were designed. The design and performance of the detectors are described. The results of the NKS2 experiment on analyzing strangeness photoproduction data using a 0.8--1.1 GeV tagged photon beam are also presented.
△ Less
Submitted 9 November, 2017;
originally announced November 2017.
-
Experimental techniques and performance of $Λ$-hypernuclear spectroscopy with the $(e,e^{\prime}K^{+})$ reaction
Authors:
T. Gogami,
C. Chen,
Y. Fujii,
O. Hashimoto,
M. Kaneta,
D. Kawama,
T. Maruta,
A. Matsumura,
S. Nagao,
S. N. Nakamura,
Y. Okayasu,
J. Reinhold,
L. Tang,
K. Tsukada,
S. A. Wood,
L. Yuan
Abstract:
The missing-mass spectroscopy of $Λ$ hypernuclei via the $(e,e^{\prime}K^{+})$ reaction has been developed through experiments at JLab Halls A and C in the last two decades. For the latest experiment, E05-115 in Hall C, we developed a new spectrometer system consisting of the HKS and HES; resulting in the best energy resolution ($E_Λ \simeq0.5$-MeV FWHM) and $B_Λ$ accuracy ($B_Λ\leq0.2$ MeV) in…
▽ More
The missing-mass spectroscopy of $Λ$ hypernuclei via the $(e,e^{\prime}K^{+})$ reaction has been developed through experiments at JLab Halls A and C in the last two decades. For the latest experiment, E05-115 in Hall C, we developed a new spectrometer system consisting of the HKS and HES; resulting in the best energy resolution ($E_Λ \simeq0.5$-MeV FWHM) and $B_Λ$ accuracy ($B_Λ\leq0.2$ MeV) in $Λ$-hypernuclear reaction spectroscopy. This paper describes the characteristics of the $(e,e^{\prime}K^{+})$ reaction compared to other reactions and experimental methods. In addition, the experimental apparatus, some of the important analyses such as the semi-automated calibration of absolute energy scale, and the performance achieved in E05-115 are presented.
△ Less
Submitted 28 January, 2018; v1 submitted 17 September, 2017;
originally announced September 2017.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Identification of $^{210}$Pb and $^{210}$Po in the bulk of copper samples with a low-background alpha particle counter
Authors:
XMASS collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. Th…
▽ More
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. The $^{210}$Pb contaminations of our oxygen free copper samples were 17-40 mBq/kg. Based on our investigation of copper samples in each production step, the $^{210}$Pb in oxygen free copper was understood to be a small residual of an electrolysis process. This method to measure bulk contaminations of $^{210}$Pb and $^{210}$Po could be applied to other materials.
△ Less
Submitted 9 January, 2018; v1 submitted 20 July, 2017;
originally announced July 2017.
-
High Precision Momentum Calibration of the Magnetic Spectrometers at MAMI for Hypernuclear Binding Energy Determination
Authors:
A. Margaryan,
J. R. M. Annand,
P. Achenbach,
R. Ajvazyan,
H. Elbakyan,
R. Montgomery,
S. N. Nakamura,
J. Pochodzalla,
F. Schulz,
Y. Toyama,
S. Zhamkochyan
Abstract:
We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency…
▽ More
We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-scattering facility can be calibrated absolutely with an accuracy $δp/p\leq 10^{-4}$, which will be crucial for high precision determination of hypernuclear masses.
△ Less
Submitted 3 August, 2016;
originally announced August 2016.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Search for two-neutrino double electron capture on $^{124}$Xe with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
J. Liu,
K. Martens,
Y. Suzuki,
R. Fujita,
K. Hosokawa
, et al. (19 additional authors not shown)
Abstract:
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$X…
▽ More
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$Xe is performed using 165.9 days of data collected with the XMASS-I liquid xenon detector. No significant excess above background was observed and we set a lower limit on the half-life as $4.7 \times 10^{21}$ years at 90% confidence level. The obtained limit has ruled out parts of some theoretical expectations. We obtain a lower limit on the $^{126}$Xe two-neutrino double electron capture half-life of $4.3 \times 10^{21}$ years at 90% confidence level as well.
△ Less
Submitted 25 May, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Authors:
Tetsuya Mizumoto,
Dai Tomono,
Atsushi Takada,
Toru Tanimori,
Shotaro Komura,
Hidetoshi Kubo,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Kiseki Nakamura,
Shogo Nakamura,
Makoto Oda,
Joseph D. Parker,
Tatsuya Sawano,
Naoto Bando,
Akira Nabetani
Abstract:
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the sc…
▽ More
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;μ\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$σ$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
△ Less
Submitted 6 August, 2015;
originally announced August 2015.
-
Letter of Intent to Construct a nuPRISM Detector in the J-PARC Neutrino Beamline
Authors:
S. Bhadra,
A. Blondel,
S. Bordoni,
A. Bravar,
C. Bronner,
J. Caravaca-Rodriguez,
M. Dziewiecki,
T. Feusels,
G. A. Fiorentini-Aguirre,
M. Friend,
L. Haegel,
M. Hartz,
R. Henderson,
T. Ishida,
M. Ishitsuka,
C. K. Jung,
A. C. Kaboth,
H. Kakuno,
H. Kamano,
A. Konaka,
Y. Kudenko,
M. Kuze,
T. Lindner,
K. Mahn,
J. F. Martin
, et al. (25 additional authors not shown)
Abstract:
As long-baseline neutrino experiments enter the precision era, the difficulties associated with understanding neutrino interaction cross sections on atomic nuclei are expected to limit experimental sensitivities to oscillation parameters. In particular, the ability to relate experimental observables to neutrino energy in previous experiments has relied solely on theoretical models of neutrino-nucl…
▽ More
As long-baseline neutrino experiments enter the precision era, the difficulties associated with understanding neutrino interaction cross sections on atomic nuclei are expected to limit experimental sensitivities to oscillation parameters. In particular, the ability to relate experimental observables to neutrino energy in previous experiments has relied solely on theoretical models of neutrino-nucleus interactions, which currently suffer from very large theoretical uncertainties.
By observing charged current $ν_μ$ interactions over a continuous range of off-axis angles from 1 to 4 degrees, the nuPRISM water Cherenkov detector can provide a direct measurement of the far detector lepton kinematics for any given set of oscillation parameters, which largely removes neutrino interaction modeling uncertainties from T2K oscillation measurements. This naturally provides a direct constraint on the relationship between lepton kinematics and neutrino energy. In addition, nuPRISM is a sensitive probe of sterile neutrino oscillations with multiple energy spectra, which provides unique constraints on possible background-related explanations of the MiniBooNE anomaly. Finally, high-precision measurements of neutrino cross sections on water are possible, including $ν_e$ measurements and the first ever measurements of neutral current interactions as a function of neutrino energy.
The nuPRISM detector also benefits the proposed Hyper-Kamiokande project. A demonstration that neutrino interaction uncertainties can be controlled will be important to understanding the physics reach of Hyper-K. In addition, nuPRISM will provide an easily accessible prototype detector for many of the new hardware components currently under consideration for Hyper-K. The following document presents the configuration, physics impact, and preliminary cost estimates for a nuPRISM detector in the J-PARC neutrino beamline.
△ Less
Submitted 13 December, 2014; v1 submitted 9 December, 2014;
originally announced December 2014.
-
Search for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Ichimura,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi
, et al. (20 additional authors not shown)
Abstract:
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data…
▽ More
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data no significant excess above background was observed in the fiducial mass of 41 kg. The present limit for the vector super-WIMPs excludes the possibility that such particles constitute all of dark matter. The absence of a signal also provides the most stringent direct constraint on the coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented sensitivity was achieved exploiting the low background at a level $10^{-4}$ kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
△ Less
Submitted 21 August, 2014; v1 submitted 2 June, 2014;
originally announced June 2014.
-
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from the XMASS-I experiment
Authors:
H. Uchida,
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (21 additional authors not shown)
Abstract:
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to…
▽ More
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to derive our limits without explicitly subtracting the remaining events which are compatible with background expectations and derive for e.g. a 50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei of 3.2 pb at the 90% confidence level.
△ Less
Submitted 29 April, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.
-
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Authors:
Y. Mizumura,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
S. Sonoda,
D. Tomono,
T. Sawano,
K. Nakamura,
Y. Matsuoka,
S. Komura,
S. Nakamura,
M. Oda,
K. Miuchi,
S. Kabuki,
Y. Kishimoto,
S. Kurosawa,
S. Iwaki
Abstract:
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of…
▽ More
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
△ Less
Submitted 7 February, 2014; v1 submitted 2 December, 2013;
originally announced December 2013.
-
Bucking Coil Implementation on PMT for Active Cancelling of Magnetic Field
Authors:
T. Gogami,
A. Asaturyan,
J. Bono,
P. Baturin,
C. Chen,
A. Chiba,
N. Chiga,
Y. Fujii,
O. Hashimoto,
D. Kawama,
T. Maruta,
V. Maxwell,
A. Mkrtchyan,
S. Nagao,
S. N. Nakamura,
J. Reinhold,
A. Shichijo,
L. Tang,
N. Taniya,
S. A. Wood,
Z. Ye
Abstract:
Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K+) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon spectrometer magnet yielded ~5 Gauss at the photomultiplier tubes (PMT) for these detectors which could not be easily shielded. As this field results in a lowered kaon…
▽ More
Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K+) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon spectrometer magnet yielded ~5 Gauss at the photomultiplier tubes (PMT) for these detectors which could not be easily shielded. As this field results in a lowered kaon detection efficiency, we implemented a bucking coil on each photomultiplier tubes to actively cancel this magnetic field, thus maximizing kaon detection efficiency.
△ Less
Submitted 2 July, 2013;
originally announced July 2013.
-
Optical measurement of acoustic radiation pressure of the near-field acoustic levitation through transparent object
Authors:
Satoshi Nakamura,
Toshiaki Furusawa,
Yasuhiro Sasao,
Kogure Katsura,
Kondo Naoki
Abstract:
It is known that macroscopic objects can be levitated for few to several hundred micrometers by near-field acoustic field and this phenomenon is called near-field acoustic levitation (NFAL). Although there are various experiments conducted to measure integrated acoustic pressure on the object surface, up to now there was no direct method to measure pressure distribution. In this study we measured…
▽ More
It is known that macroscopic objects can be levitated for few to several hundred micrometers by near-field acoustic field and this phenomenon is called near-field acoustic levitation (NFAL). Although there are various experiments conducted to measure integrated acoustic pressure on the object surface, up to now there was no direct method to measure pressure distribution. In this study we measured the acoustic radiation pressure of the near-field acoustic levitation via pressure-sensitive paint.
△ Less
Submitted 28 May, 2013;
originally announced May 2013.
-
XMASS detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Nishiie,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (23 additional authors not shown)
Abstract:
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
△ Less
Submitted 13 January, 2013;
originally announced January 2013.
-
Search for solar axions in XMASS, a large liquid-xenon detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi,
A. Murata
, et al. (21 additional authors not shown)
Abstract:
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The b…
▽ More
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are 1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced the most stringent limit, which is better than that previously derived from astrophysical arguments regarding the Sun to date.
△ Less
Submitted 29 May, 2013; v1 submitted 26 December, 2012;
originally announced December 2012.
-
An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements
Authors:
S. Naimi,
S. Nakamura,
Y. Ito,
H. Mita,
K. Okada,
A. Ozawa,
P. Schury,
T. Sonoda,
A. Takamine,
M. Wada,
H. Wollnik
Abstract:
For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pum** system to transport ions from the ESI to a precision mass analyzer. Molecular ions…
▽ More
For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pum** system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.
△ Less
Submitted 16 December, 2012; v1 submitted 6 November, 2012;
originally announced November 2012.
-
Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei
Authors:
T. Sonoda,
M. Wada,
H. Tomita,
C. Sakamoto,
T. Takatsuka,
T. Furukawa,
H. Iimura,
Y. Ito,
T. Kubo,
Y. Matsuo,
H. Mita,
S. Naimi,
S. Nakamura,
T. Noto,
P. Schury,
T. Shinozuka,
T. Wakui,
H. Miyatake,
S. Jeong,
H. Ishiyama,
Y. X. Watanabe,
Y. Hirayama,
K. Okada,
A. Takamine
Abstract:
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pum**, in combination with a sextupole ion beam guide (SPIG), has been d…
▽ More
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pum**, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stop** high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations.
△ Less
Submitted 24 October, 2012;
originally announced October 2012.
-
Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon
Authors:
K. Ueshima,
K. Abe,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
Y. Koshio,
J. Liu,
K. Martens,
S. Moriyama,
M. Nakahata,
H. Nishiie,
H. Ogawa,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
M. Yamashita,
K. Fujii,
I. Murayama,
S. Nakamura,
K. Otsuka,
Y. Takeuchi,
Y. Fukuda,
K. Nishijima
, et al. (12 additional authors not shown)
Abstract:
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a singl…
▽ More
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.
△ Less
Submitted 11 June, 2011;
originally announced June 2011.
-
Performance test of wavelength-shifting acrylic plastic Cherenkov detector
Authors:
B. Beckford,
A. de la Puente,
Y. Fuji,
K. Futatsukawa,
O. Hashimoto,
M. Kaneta,
H. Kanda,
K. Maeda,
A. Matsumura,
S. N. Nakamura,
J. Reinhold,
L. Tang,
K. Tsukada
Abstract:
The collection efficiency for Cherenkov light incident on a wavelength shifting plate (WLS) has been determined during a beam test at the Proton Synchrotron facility located in the National Laboratory for High Energy Physics (KEK), Tsukuba, Japan. The experiment was conducted in order to determine the detector's response to photoelectrons converted from photons produced by a fused silica radiator;…
▽ More
The collection efficiency for Cherenkov light incident on a wavelength shifting plate (WLS) has been determined during a beam test at the Proton Synchrotron facility located in the National Laboratory for High Energy Physics (KEK), Tsukuba, Japan. The experiment was conducted in order to determine the detector's response to photoelectrons converted from photons produced by a fused silica radiator; this allows for an approximation of the detector's quality. The yield of the photoelectrons produced through internally generated Cherenkov light as well as light incident from the radiator was measured as a function of the momentum of the incident hadron beam. The yield is proportional to sin$^2$$θ_c$, where $θ_{c}$ is the opening angle of the Cherenkov light created. Based on estimations and results from similarly conducted tests, where the collection efficiency was roughly 39%, the experimental result was expected to be around 40% for internally produced light from the WLS. The results of the experiment determined the photon collection response efficiency of the WLS to be roughly 62% for photons created in a fused silica radiator and 41% for light created in the WLS.
△ Less
Submitted 22 May, 2013; v1 submitted 1 July, 2010;
originally announced July 2010.
-
Development of Thick-foil and Fine-pitch GEMs with a Laser Etching Technique
Authors:
T. Tamagawa,
A. Hayato,
F. Asami,
K. Abe,
S. Iwamoto,
S. Nakamura,
A. Hayato,
T. Iwahashi,
S. Konami,
H. Hamagaki,
Y. L. Yamaguchi,
H. Tawara,
K. Makishima
Abstract:
We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The effective gain of the thick-foil GEM with a hole pitch of 140 um, a hole diameter of 70 um, and a thickness of 100 um reached a value of 10^4 at an applied v…
▽ More
We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The effective gain of the thick-foil GEM with a hole pitch of 140 um, a hole diameter of 70 um, and a thickness of 100 um reached a value of 10^4 at an applied voltage of 720 V. The measured effective gain of the thick-foil and fine-pitch GEM (80 um pitch, 40 um diameter, and 100 um thick) was similar to that of the thick-foil GEM. The gain stability was measured for the thick-foil and fine-pitch GEM, showing no significant increase or decrease as a function of elapsed time from applying the high voltage. The gain stability over 3 h of operation was about 0.5%. Gain map** across the GEM showed a good uniformity with a standard deviation of about 4%. The distribution of hole diameters across the GEM was homogeneous with a standard deviation of about 3%. There was no clear correlation between the gain and hole diameter maps.
△ Less
Submitted 2 October, 2009;
originally announced October 2009.