-
Enhanced ultrafast X-ray diffraction by transient resonances
Authors:
Stephan Kuschel,
Phay J. Ho,
Andre Al Haddad,
Felix Zimmermann,
Leonie Flueckiger,
Matthew R. Ware,
Joseph Duris,
James P. MacArthur,
Alberto Lutman,
Ming-Fu Lin,
Xiang Li,
Kazutaka Nakahara,
Jeff W. Aldrich,
Peter Walter,
Linda Young,
Christoph Bostedt,
Agostino Marinelli,
Tais Gorkhover
Abstract:
Diffraction-before-destruction imaging with single ultrashort X-ray pulses has the potential to visualise non-equilibrium processes, such as chemical reactions, at the nanoscale with sub-femtosecond resolution in the native environment without the need of crystallization. Here, a nanospecimen partially diffracts a single X-ray flash before sample damage occurs. The structural information of the sa…
▽ More
Diffraction-before-destruction imaging with single ultrashort X-ray pulses has the potential to visualise non-equilibrium processes, such as chemical reactions, at the nanoscale with sub-femtosecond resolution in the native environment without the need of crystallization. Here, a nanospecimen partially diffracts a single X-ray flash before sample damage occurs. The structural information of the sample can be reconstructed from the coherent X-ray interference image. State-of-art spatial resolution of such snapshots from individual heavy element nanoparticles is limited to a few nanometers. Further improvement of spatial resolution requires higher image brightness which is ultimately limited by bleaching effects of the sample. We compared snapshots from individual 100 nm Xe nanoparticles as a function of the X-ray pulse duration and incoming X-ray intensity in the vicinity of the Xe M-shell resonance. Surprisingly, images recorded with few femtosecond and sub-femtosecond pulses are up to 10 times brighter than the static linear model predicts. Our Monte-Carlo simulation and statistical analysis of the entire data set confirms these findings and attributes the effect to transient resonances. Our simulation suggests that ultrafast form factor changes during the exposure can increase the brightness of X-ray images by several orders of magnitude. Our study guides the way towards imaging with unprecedented combination of spatial and temporal resolution at the nanoscale.
△ Less
Submitted 12 July, 2022;
originally announced July 2022.
-
Balanced Detection in Femtosecond X-ray Absorption Spectroscopy to Reach the Ultimate Sensitivity Limit
Authors:
W. F. Schlotter,
M. Beye,
S. Zohar,
G. Coslovich,
G. L. Dakovski,
M. -F. Lin,
Y. Liu,
A. Reid,
S. Stubbs,
P. Walter,
K. Nakahara,
P. Hart,
P. S. Miedema,
L. LeGuyader,
K. Hofhuis,
Phu Tran Phong Le,
Johan E. ten Elshof,
H. Hilgenkamp,
G. Koster,
X. H. Verbeek,
S. Smit,
M. S. Golden,
H. A. Durr,
A. Sakdinawat
Abstract:
X-ray absorption spectroscopy (XAS) is a powerful and well established technique with sensitivity to elemental and chemical composition. Despite these advantages, its implementation has not kept pace with the development of ultrafast pulsed x-ray sources where XAS can capture femtosecond chemical processes. X-ray Free Electron Lasers (XFELs) deliver femtosecond, narrow bandwidth (…
▽ More
X-ray absorption spectroscopy (XAS) is a powerful and well established technique with sensitivity to elemental and chemical composition. Despite these advantages, its implementation has not kept pace with the development of ultrafast pulsed x-ray sources where XAS can capture femtosecond chemical processes. X-ray Free Electron Lasers (XFELs) deliver femtosecond, narrow bandwidth ($\frac{ΔE}{E} < 0.5\%$) pulses containing $\sim 10^{10}$ photons. However, the energy contained in each pulse fluctuates thus complicating pulse by pulse efforts to quantify the number of photons. Improvements in counting the photons in each pulse have defined the state of the art for XAS sensitivity. Here we demonstrate a final step in these improvements through a balanced detection method that approaches the photon counting shot noise limit. In doing so, we obtain high quality absorption spectra from the insulator-metal transition in VO$_2$ and unlock a method to explore dilute systems, subtle processes and nonlinear phenomena with ultrafast x-rays. The method is especially beneficial for x-ray light sources where integration and averaging are not viable options to improve sensitivity.
△ Less
Submitted 24 June, 2020;
originally announced June 2020.
-
Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs
Authors:
G. Blaj,
A. Dragone,
C. J. Kenney,
F. Abu-Nimeh,
P. Caragiulo,
D. Doering,
M. Kwiatkowski,
J. Pines,
M. Weaver,
S. Boutet,
G. Carini,
C. -E. Chang,
P. Hart,
J. Hasi,
M. Hayes,
R. Herbst,
J. Koglin,
K. Nakahara,
J. Segal,
G. Haller
Abstract:
ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs,…
▽ More
ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352x384 pixels of 100 $μ$m x 100 $μ$m each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e$^-$ equivalent noise charge (ENC), and a range of 11000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
The SeaQuest Spectrometer at Fermilab
Authors:
SeaQuest Collaboration,
C. A. Aidala,
J. R. Arrington,
C. Ayuso,
B. M. Bowen,
M. L. Bowen,
K. L. Bowling,
A. W. Brown,
C. N. Brown,
R. Byrd,
R. E. Carlisle,
T. Chang,
W. -C. Chang,
A. Chen,
J. -Y. Chen,
D. C. Christian,
X. Chu,
B. P. Dannowitz,
M. Daugherity,
M. Diefenthaler,
J. Dove,
C. Durandet,
L. El Fassi,
E. Erdos,
D. M. Fox
, et al. (73 additional authors not shown)
Abstract:
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets…
▽ More
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.
△ Less
Submitted 9 February, 2019; v1 submitted 29 June, 2017;
originally announced June 2017.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.