-
Single-shot 3D photoacoustic computed tomography with a densely packed array for transcranial functional imaging
Authors:
Rui Cao,
Yilin Luo,
**hua Xu,
Xiaofei Luo,
Ku Geng,
Yousuf Aborahama,
Manxiu Cui,
Samuel Davis,
Shuai Na,
Xin Tong,
Cindy Liu,
Karteek Sastry,
Konstantin Maslov,
Peng Hu,
Yide Zhang,
Li Lin,
Yang Zhang,
Lihong V. Wang
Abstract:
Photoacoustic computed tomography (PACT) is emerging as a new technique for functional brain imaging, primarily due to its capabilities in label-free hemodynamic imaging. Despite its potential, the transcranial application of PACT has encountered hurdles, such as acoustic attenuations and distortions by the skull and limited light penetration through the skull. To overcome these challenges, we hav…
▽ More
Photoacoustic computed tomography (PACT) is emerging as a new technique for functional brain imaging, primarily due to its capabilities in label-free hemodynamic imaging. Despite its potential, the transcranial application of PACT has encountered hurdles, such as acoustic attenuations and distortions by the skull and limited light penetration through the skull. To overcome these challenges, we have engineered a PACT system that features a densely packed hemispherical ultrasonic transducer array with 3072 channels, operating at a central frequency of 1 MHz. This system allows for single-shot 3D imaging at a rate equal to the laser repetition rate, such as 20 Hz. We have achieved a single-shot light penetration depth of approximately 9 cm in chicken breast tissue utilizing a 750 nm laser (withstanding 3295-fold light attenuation and still retaining an SNR of 74) and successfully performed transcranial imaging through an ex vivo human skull using a 1064 nm laser. Moreover, we have proven the capacity of our system to perform single-shot 3D PACT imaging in both tissue phantoms and human subjects. These results suggest that our PACT system is poised to unlock potential for real-time, in vivo transcranial functional imaging in humans.
△ Less
Submitted 26 June, 2023;
originally announced June 2023.
-
Predicting Density of States via Multi-modal Transformer
Authors:
Namkyeong Lee,
Heewoong Noh,
Sungwon Kim,
Dongmin Hyun,
Gyoung S. Na,
Chanyoung Park
Abstract:
The density of states (DOS) is a spectral property of materials, which provides fundamental insights on various characteristics of materials. In this paper, we propose a model to predict the DOS by reflecting the nature of DOS: DOS determines the general distribution of states as a function of energy. Specifically, we integrate the heterogeneous information obtained from the crystal structure and…
▽ More
The density of states (DOS) is a spectral property of materials, which provides fundamental insights on various characteristics of materials. In this paper, we propose a model to predict the DOS by reflecting the nature of DOS: DOS determines the general distribution of states as a function of energy. Specifically, we integrate the heterogeneous information obtained from the crystal structure and the energies via multi-modal transformer, thereby modeling the complex relationships between the atoms in the crystal structure, and various energy levels. Extensive experiments on two types of DOS, i.e., Phonon DOS and Electron DOS, with various real-world scenarios demonstrate the superiority of DOSTransformer. The source code for DOSTransformer is available at https://github.com/HeewoongNoh/DOSTransformer.
△ Less
Submitted 10 April, 2023; v1 submitted 13 March, 2023;
originally announced March 2023.
-
Transcranial photoacoustic computed tomography of human brain function
Authors:
Yang Zhang,
Shuai Na,
Karteekeya Sastry,
Jonathan J. Russin,
Peng Hu,
Li Lin,
Xin Tong,
Kay B. Jann,
Danny J. Wang,
Charles Y. Liu,
Lihong V. Wang
Abstract:
Herein we report the first in-human transcranial imaging of brain function using photoacoustic computed tomography. Functional responses to benchmark motor tasks were imaged on both the skull-less and the skull-intact hemispheres of a hemicraniectomy patient. The observed brain responses in these preliminary results demonstrate the potential of photoacoustic computed tomography for achieving trans…
▽ More
Herein we report the first in-human transcranial imaging of brain function using photoacoustic computed tomography. Functional responses to benchmark motor tasks were imaged on both the skull-less and the skull-intact hemispheres of a hemicraniectomy patient. The observed brain responses in these preliminary results demonstrate the potential of photoacoustic computed tomography for achieving transcranial functional imaging.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
Optical calibration of the SNO+ detector in the water phase with deployed sources
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
F. Barão,
N. Barros,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
M. Chen,
O. Chkvorets,
B. Cleveland,
D. Cookman,
J. Corning,
M. A. Cox,
C. Deluce,
M. M. Depatie
, et al. (98 additional authors not shown)
Abstract:
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light…
▽ More
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.
△ Less
Submitted 4 October, 2021; v1 submitted 7 June, 2021;
originally announced June 2021.
-
The SNO+ Experiment
Authors:
SNO+ Collaboration,
:,
V. Albanese,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
S. Back,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes,
C. Beaudoin,
E. W. Beier,
G. Berardi,
A. Bialek,
S. D. Biller,
E. Blucher
, et al. (229 additional authors not shown)
Abstract:
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of pr…
▽ More
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta ($0νββ$) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of $^{130}$Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for $0νββ$ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for $0νββ$ decay is scalable: a future phase with high $^{130}$Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region.
△ Less
Submitted 25 August, 2021; v1 submitted 23 April, 2021;
originally announced April 2021.
-
Development, characterisation, and deployment of the SNO+ liquid scintillator
Authors:
SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
L. Anselmo,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca
, et al. (201 additional authors not shown)
Abstract:
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity,…
▽ More
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is compatible with acrylic and has a competitive light yield to pre-existing liquid scintillators while conferring other advantages including longer attenuation lengths, superior safety characteristics, chemical simplicity, ease of handling, and logistical availability. Its properties have been extensively characterized and are presented here. This liquid scintillator is now used in several neutrino physics experiments in addition to SNO+.
△ Less
Submitted 21 February, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Measurement of neutron-proton capture in the SNO+ water phase
Authors:
The SNO+ Collaboration,
:,
M. R. Anderson,
S. Andringa,
M. Askins,
D. J. Auty,
N. Barros,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
E. Caden,
E. J. Callaghan,
J. Caravaca,
D. Chauhan,
M. Chen,
O. Chkvorets,
B. Cleveland,
M. A. Cox,
M. M. Depatie,
J. Dittmer
, et al. (108 additional authors not shown)
Abstract:
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.…
▽ More
The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV $γ$ produced by neutron capture on hydrogen have been made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV $γ$. Analysis of the delayed coincidence between the 4.4-MeV $γ$ and the 2.2-MeV capture $γ$ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. In addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb.
△ Less
Submitted 13 July, 2020; v1 submitted 24 February, 2020;
originally announced February 2020.
-
Search for invisible modes of nucleon decay in water with the SNO+ detector
Authors:
SNO+ Collaboration,
:,
M. Anderson,
S. Andringa,
E. Arushanova,
S. Asahi,
M. Askins,
D. J. Auty,
A. R. Back,
Z. Barnard,
N. Barros,
D. Bartlett,
F. Barão,
R. Bayes,
E. W. Beier,
A. Bialek,
S. D. Biller,
E. Blucher,
R. Bonventre,
M. Boulay,
D. Braid,
E. Caden,
E. J. Callaghan,
J. Caravaca,
J. Carvalho
, et al. (173 additional authors not shown)
Abstract:
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of…
▽ More
This paper reports results from a search for nucleon decay through 'invisible' modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently de-excite, often emitting detectable gamma rays. A search for such gamma rays yields limits of $2.5 \times 10^{29}$ y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and $3.6 \times 10^{29}$ y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of $1.3\times 10^{28}$ y for $nn$, $2.6\times 10^{28}$ y for $pn$ and $4.7\times 10^{28}$ y for $pp$, an improvement over existing limits by close to three orders of magnitude for the latter two.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.
-
Neutron detection in the SNO+ water phase
Authors:
Y. Liu,
S. Andringa,
D. Auty,
F. Barão,
R. Bayes,
E. Caden,
C. Grant,
J. Grove,
B. Krar,
A. LaTorre,
L. Lebanowski,
J. Lidgard,
J. Maneira,
P. Mekarski,
S. Nae,
T. Pershing,
I. Semenec,
K. Singh,
P. Skensved,
B. Tam,
A. Wright
Abstract:
SNO+ is a multipurpose neutrino experiment located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector started taking physics data in May 2017 and is currently completing its first phase, as a pure water Cherenkov detector. The low trigger threshold of the SNO+ detector allows for a substantial neutron detection efficiency, as observed with a deployed ^{241}Am^{9}Be source. Usi…
▽ More
SNO+ is a multipurpose neutrino experiment located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector started taking physics data in May 2017 and is currently completing its first phase, as a pure water Cherenkov detector. The low trigger threshold of the SNO+ detector allows for a substantial neutron detection efficiency, as observed with a deployed ^{241}Am^{9}Be source. Using a statistical analysis of one hour AmBe calibration data, we report a neutron capture constant of 208.2 + 2.1(stat.) us and a lower bound of the neutron detection efficiency of 46% at the center of the detector.
△ Less
Submitted 21 August, 2018;
originally announced August 2018.
-
The COSINE-100 Data Acquisition System
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. S. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim
, et al. (23 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital co…
▽ More
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
△ Less
Submitted 26 June, 2018;
originally announced June 2018.
-
Three Dimensional Measurements by Deflectometry and Double Hilbert Transform
Authors:
Silin Na,
Sanghoon Shin,
Younghun Yu
Abstract:
An improved phase retrieval method based Hilbert transform is introduced to quantitatively calculate the phase distribution from distorted fringe pattern. Also phase measurement deflectomety are widely used in specular type samples. The background noise or bias should be suppressed prior to apply Hilbert transform. A method for suppression background noise double Hilbert transform is presented, wh…
▽ More
An improved phase retrieval method based Hilbert transform is introduced to quantitatively calculate the phase distribution from distorted fringe pattern. Also phase measurement deflectomety are widely used in specular type samples. The background noise or bias should be suppressed prior to apply Hilbert transform. A method for suppression background noise double Hilbert transform is presented, which requires only one image. The method is easy to implement, and it is able to conducting automated fast measurements. We have demonstrated the double Hilbert transform method to retrieve the phase and background suppression by computer simulation and experiment in phase measuring deflectometry method.
△ Less
Submitted 19 May, 2016;
originally announced May 2016.
-
Mechanical Characterization of Amyloid Fibrils Using Coarse-Grained Normal Mode Analysis
Authors:
Gwonchan Yoon,
**hak Kwak,
Jae In Kim,
Sungsoo Na,
Kilho Eom
Abstract:
Recent experimental studies have shown that amyloid fibril formed by aggregation of β peptide exhibits excellent mechanical properties comparable to other protein materials such as actin filaments and microtubules. These excellent mechanical properties of amyloid fibrils are related to their functional role in disease expression. This indicates the necessity to understand how an amyloid fibril ach…
▽ More
Recent experimental studies have shown that amyloid fibril formed by aggregation of β peptide exhibits excellent mechanical properties comparable to other protein materials such as actin filaments and microtubules. These excellent mechanical properties of amyloid fibrils are related to their functional role in disease expression. This indicates the necessity to understand how an amyloid fibril achieves the remarkable mechanical properties through self-aggregation with structural hierarchy, highlighting the structure-property-function relationship for amyloids, whereas such relationship still remains elusive. In this work, we have studied the mechanical properties of human islet amyloid polypeptide (hIAPP) with respect to its structural hierarchies and structural shapes by coarse-grained normal mode analysis. Our simulation shows that hIAPP fibril can achieve the excellent bending rigidity via specific aggregation pattern such as antiparallel stacking of β peptides. Moreover, we have found the length-dependent mechanical properties of amyloids. This length-dependent property has been elucidated from Timoshenko beam model that takes into account the shear effect on the bending of amyloids. In summary, our study sheds light on the importance of not only the molecular architecture, which encodes the mechanical properties of the fibril, but also the shear effect on the mechanical (bending) behavior of the fibril.
△ Less
Submitted 9 May, 2011;
originally announced May 2011.
-
Role of Loading Device on Single-Molecule Mechanical Manipulation of Free Energy Landscape
Authors:
Gwonchan Yoon,
Sungsoo Na,
Kilho Eom
Abstract:
Single-molecule mechanical manipulation has enabled the quantitative understanding of the kinetics of bond ruptures as well as protein unfolding mechanism. Single-molecule experiments with theoretical models have allowed one to gain insight into free energy landscape for chemical bond and/or protein folding. For mechanically induced bond rupture, the bond-rupture kinetics may be governed by loadin…
▽ More
Single-molecule mechanical manipulation has enabled the quantitative understanding of the kinetics of bond ruptures as well as protein unfolding mechanism. Single-molecule experiments with theoretical models have allowed one to gain insight into free energy landscape for chemical bond and/or protein folding. For mechanically induced bond rupture, the bond-rupture kinetics may be governed by loading device. However, the role of loading device on the kinetics of mechanical rupture has been rarely received much attention until recently. In this work, we have theoretically and/or computationally studied the effect of loading-device stiffness on the kinetics of mechanical unfolding. Specifically, we have considered a one-dimensional model for a bond rupture whose kinetics is depicted by Kramers' theory. It is elucidated that the kinetics of bond rupture is determined by force constant of loading device. The Brownian dynamics simulation of a bond rupture is considered in order to validate our theory. It is illustrated that the mean rupture force is dependent on the force constant of a loading device, such that increase in the loading-device stiffness leads to the higher bond rupture force. Moreover, we have taken into account the computational simulation of mechanical unfolding of a small protein, i.e. β-hairpin. Our simulation shows that unfolding force is highly correlated with the stiffness of a loading device. Our numerical and theoretical studies highlight the significance of a loading device on the kinetics of mechanical unfolding of a chemical bond and/or a folded domain in the single-molecule mechanical experiments.
△ Less
Submitted 7 May, 2010; v1 submitted 26 April, 2010;
originally announced April 2010.