Skip to main content

Showing 1–4 of 4 results for author: Nadig, V

Searching in archive physics. Search in all archives.
.
  1. arXiv:2305.14855  [pdf, other

    physics.ins-det

    Study experimental time resolution limits of recent ASICs at Weeroc with different SiPMs and scintillators

    Authors: Tasneem Saleem, Salleh Ahmad, Jean-Baptiste Cizel, Christophe De La Taille, Maxime Morenas, Vanessa Nadig, Florent Perez, Volkmar Schulz, Stefan Gundacker, Julien Fleury

    Abstract: Medical applications, such as Positron Emission Tomography (PET), and space applications, such as Light Detection and Ranging (LIDAR), are in need of highly specialized ASICs. Weeroc, in collaboration with different partners, is highly involved in develo** a new generation of front-end ASICs. In the context of a joined LIDAR project among Weeroc, CNES, and Airbus, Weeroc is working on the develo… ▽ More

    Submitted 5 October, 2023; v1 submitted 24 May, 2023; originally announced May 2023.

    Comments: Prepared for submission to JINST

  2. arXiv:1911.08156  [pdf, other

    physics.med-ph physics.ins-det

    Evaluation Of The PETsys TOFPET2 ASIC In Multi-Channel Coincidence Experiments

    Authors: Vanessa Nadig, David Schug, Bjoern Weissler, Volkmar Schulz

    Abstract: Aiming to measure the difference in arrival times of two coincident gamma-photons with an accuracy in the order of 200 ps, time-of-flight positron emission tomography systems commonly employ silicon photomultipliers (SiPMs) and high-resolution digitization electronics, application specific integrated circuits (ASICs). This work evaluates the performance of the TOFPET2 ASIC, released by PETsys Elec… ▽ More

    Submitted 10 February, 2021; v1 submitted 19 November, 2019; originally announced November 2019.

  3. arXiv:1908.05878  [pdf, other

    physics.ins-det physics.med-ph

    Investigation of the Power Consumption of the PETsys TOFPET2 ASIC

    Authors: Vanessa Nadig, Bjoern Weissler, Harald Radermacher, Volkmar Schulz, David Schug

    Abstract: In state-of-the-art positron emission (PET) tomography systems, application-specific integrated circuits (ASICs)are commonly used to precisely digitize the signals of analog silicon photo-multipliers (SiPMs). However, when operating PET electronics in a magnetic resonance (MR) system, one faces the challenge of mutual interference of these imaging techniques. To prevent signal deterioration along… ▽ More

    Submitted 12 November, 2019; v1 submitted 16 August, 2019; originally announced August 2019.

    Comments: 10 pages, 7 figures

    Report number: Volume: 4, Issue: 3, May 2020

    Journal ref: IEEE Transactions on Radiation and Plasma Medical Sciences 2020

  4. arXiv:1808.05833  [pdf, other

    physics.ins-det physics.med-ph

    Initial Measurements with the PETsys TOFPET2 ASIC Evaluation Kit and a Characterization of the ASIC TDC

    Authors: David Schug, Vanessa Nadig, Bjoern Weissler, Pierre Gebhardt, Volkmar Schulz

    Abstract: For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3x3x5 mm${}^3$ LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds (D_T1) in the timing branch from vth_t1 = 5 - 30. The overvoltage was varied in a range of 1.25 V - 7.25 V. The ambient temperature was kept at 16°C. For all meas… ▽ More

    Submitted 28 November, 2018; v1 submitted 17 August, 2018; originally announced August 2018.

    Comments: This paper is under review with IEEE TRPMS. It has been presented in a talk at the PSMR 2018. This version of the manuscript was submitted as revision 2 to TRPMS after incrporating the comments of the reviewers. Only minor textchanges were made. Results, values and figures did not change

    Report number: Early Access 2018

    Journal ref: IEEE Transactions on Radiation and Plasma Medical Sciences 2018