Modelling large mass removal in adsorption columns
Authors:
Timothy G. Myers,
Marc Calvo-Schwarzwalder,
Francesc Font,
Abel Valverde
Abstract:
A mathematical model is developed to describe column adsorption when the contaminant constitutes a significant amount of the fluid. This requires modelling the variation of pressure and velocity, in addition to the usual advection-diffusion-adsorption and kinetic equations describing concentration and adsorption rates. The model builds on previous work based on a linear kinetic equation, to includ…
▽ More
A mathematical model is developed to describe column adsorption when the contaminant constitutes a significant amount of the fluid. This requires modelling the variation of pressure and velocity, in addition to the usual advection-diffusion-adsorption and kinetic equations describing concentration and adsorption rates. The model builds on previous work based on a linear kinetic equation, to include both physical and chemical adsorption. A semi-analytical solution is developed and validated against a numerical solution. The model is tested against experimental data for the adsorption of large quantities of CO$_2$ from a helium mixture, with a CO$_2$ volume fraction ranging from 14% to 69%, and a N$_2$ mixture with 16% to 33% CO$_2$ volume fraction. Our results show a significant improvement with respect to models for the removal of trace amounts of contaminant.
△ Less
Submitted 5 April, 2024; v1 submitted 3 April, 2024;
originally announced April 2024.
-
Mathematical model for fluoride-removal filters
Authors:
Lucy C. Auton,
Marc Martínez I Àvila,
Shanmuk S. Ravuru,
Sirshendu De,
Tim G. Myers,
Abel Valverde
Abstract:
We develop a model that captures the dominant chemical mechanisms involved in the removal of fluoride from water by a novel adsorbent comprising mineral rich carbon (MRC) and chemically treated mineral rich carbon (TMRC). Working with experimental data, we validate the model for both MRC and TMRC based on the underlying chemical reactions. The model we derive from the chemical composition of TMRC…
▽ More
We develop a model that captures the dominant chemical mechanisms involved in the removal of fluoride from water by a novel adsorbent comprising mineral rich carbon (MRC) and chemically treated mineral rich carbon (TMRC). Working with experimental data, we validate the model for both MRC and TMRC based on the underlying chemical reactions. The model we derive from the chemical composition of TMRC and MRC shows good agreement with experimental results.
△ Less
Submitted 6 December, 2023;
originally announced December 2023.
-
An analytical investigation into solute transport and sorption via intra-particle diffusion in the dual-porosity limit
Authors:
Lucy C. Auton,
Maria Aguareles,
Abel Valverde,
Timothy G. Myers,
Marc Calvo-Schwarzwalder
Abstract:
We develop a mathematical model for adsorption based on averaging the flow around, and diffusion inside, adsorbent particles in a column. The model involves three coupled partial differential equations for the contaminant concentration both in the carrier fluid and within the particle as well as the adsorption rate. The adsorption rate is modelled using the Sips equation, which is suitable for des…
▽ More
We develop a mathematical model for adsorption based on averaging the flow around, and diffusion inside, adsorbent particles in a column. The model involves three coupled partial differential equations for the contaminant concentration both in the carrier fluid and within the particle as well as the adsorption rate. The adsorption rate is modelled using the Sips equation, which is suitable for describing both physical and chemical adsorption mechanisms. Non-dimensionalisation is used to determine the controlling parameter groups as well as to determine negligible terms and so reduce the system complexity. The inclusion of intra-particle diffusion introduces new dimensionless parameters to those found in standard works, including a form of internal Damköhler number and a new characteristic time scale. We provide a numerical method for the full model and show how in certain situations a travelling wave approach can be utilized to find analytical solutions. The model is validated against available experimental data for the removal of Mercury(II) and CO$_\text{2}$. The results show excellent agreement with measurements of column outlet contaminant concentration and provide insights into the underlying chemical reactions.
△ Less
Submitted 16 November, 2023;
originally announced November 2023.
-
Measurement of the Electron Magnetic Moment
Authors:
X. Fan,
T. G. Myers,
B. A. D. Sukra,
G. Gabrielse
Abstract:
The electron magnetic moment,$-μ/μ_B = g/2 = 1.001 \, 159 \, 652 \, 180 \, 59 \, (13) \, [0.13\, \rm{ppt}]$, is determined 2.2 times more accurately than the value that stood for 14 years. The most precisely determined property of an elementary particle tests the most precise prediction of the Standard Model (SM) to $1$ part in $10^{12}$. The test would improve an order of magnitude if the uncerta…
▽ More
The electron magnetic moment,$-μ/μ_B = g/2 = 1.001 \, 159 \, 652 \, 180 \, 59 \, (13) \, [0.13\, \rm{ppt}]$, is determined 2.2 times more accurately than the value that stood for 14 years. The most precisely determined property of an elementary particle tests the most precise prediction of the Standard Model (SM) to $1$ part in $10^{12}$. The test would improve an order of magnitude if the uncertainty from discrepant measurements of the fine structure constant $α$ is eliminated since the SM prediction is a function of $α$. The new measurement and SM theory together predict $α^{-1}=137.035 \, 999 \, 166 \, (15) \, [0.11 \, \rm{ppb}]$ with an uncertainty ten times smaller than the current disagreement between measured $α$ values.
△ Less
Submitted 7 December, 2022; v1 submitted 26 September, 2022;
originally announced September 2022.
-
One-Electron Quantum Cyclotron as a Milli-eV Dark-Photon Detector
Authors:
Xing Fan,
Gerald Gabrielse,
Peter W. Graham,
Roni Harnik,
Thomas G. Myers,
Harikrishnan Ramani,
Benedict A. D. Sukra,
Samuel S. Y. Wong,
Yawen Xiao
Abstract:
We propose using trapped electrons as high-$Q$ resonators for detecting meV dark photon dark matter. When the rest energy of the dark photon matches the energy splitting of the two lowest cyclotron levels, the first excited state of the electron cyclotron will be resonantly excited. A proof-of-principle measurement, carried out with one electron, demonstrates that the method is background-free ove…
▽ More
We propose using trapped electrons as high-$Q$ resonators for detecting meV dark photon dark matter. When the rest energy of the dark photon matches the energy splitting of the two lowest cyclotron levels, the first excited state of the electron cyclotron will be resonantly excited. A proof-of-principle measurement, carried out with one electron, demonstrates that the method is background-free over a 7.4 day search. It sets a limit on dark photon dark matter at 148 GHz (0.6 meV) that is around 75 times better than previous constraints. Dark photon dark matter in the 0.1-1 meV mass range (20-200 GHz) could likely be detected at a similar sensitivity in an apparatus designed for dark photon detection.
△ Less
Submitted 9 January, 2023; v1 submitted 12 August, 2022;
originally announced August 2022.
-
Modelling mass transfer from a packed bed by fluid extraction
Authors:
Timothy G. Myers,
Abel Valverde,
Maria Aguareles,
Marc Calvo-Schwarzwalder,
Francesc Font
Abstract:
A mathematical model describing the erosion or leaching of a solid material by a flowing fluid in a column is developed. This involves an advection-diffusion equation coupled to a linear kinetic reaction describing the mass transfer between the solid and fluid. Two specific cases are analysed, the first where the extracted material has the same saturation solubility and rate of mass transfer throu…
▽ More
A mathematical model describing the erosion or leaching of a solid material by a flowing fluid in a column is developed. This involves an advection-diffusion equation coupled to a linear kinetic reaction describing the mass transfer between the solid and fluid. Two specific cases are analysed, the first where the extracted material has the same saturation solubility and rate of mass transfer throughout the process, the second where the solubility switches after a certain amount of erosion. In the first case there are only two model unknowns, the solubility and mass transfer coefficient, in the second there is a third unknown, the second solubility. Exploiting the fact that erosion is a slow process (relative to the flow rate) a perturbation solution based on the smallness of the amount removed is developed to describe the concentration and radius throughout the column. From this an analytical expression for the extracted fraction is obtained. The extracted fraction has a large linear section which results in a simple calculation to estimate the initial solubility from a very few or even a single data point. The remaining unknowns may also be easily calculated from the formula and later data points. A numerical solution, using finite differences, is developed to verify the perturbation solution. The analytical solution is also verified against experimental data for the removal of lanolin from wool fibres with a supercritical CO$_\text{2}$/ethanol solvent. Values for the mass transfer rate and two solubilities are obtained for different pressures and shown to provide excellent agreement with a series of experimental results for the extracted fraction.
△ Less
Submitted 25 January, 2022;
originally announced January 2022.
-
Magnetic nanodrug delivery in non-Newtonian blood flows
Authors:
C. Fanelli,
K. Kaouri,
T. N. Phillips,
T. G. Myers,
F. Font
Abstract:
With the goal of determining strategies to maximise drug delivery to a specific site in the body, we developed a mathematical model for the transport of drug nanocarriers (nanoparticles) in the bloodstream under the influence of an external magnetic field. Under the assumption of long (compared to the radius) blood vessels the Navier-Stokes equations are reduced, to a simpler model consistently wi…
▽ More
With the goal of determining strategies to maximise drug delivery to a specific site in the body, we developed a mathematical model for the transport of drug nanocarriers (nanoparticles) in the bloodstream under the influence of an external magnetic field. Under the assumption of long (compared to the radius) blood vessels the Navier-Stokes equations are reduced, to a simpler model consistently with lubrication theory. Under these assumptions, analytical results are compared for Newtonian, power-law, Carreau and Ellis fluids, and these clearly demonstrate the importance of shear thinning effects when modelling blood flow. Incorporating nanoparticles and a magnetic field to the model we develop a numerical scheme and study the particle motion for different field strengths. We demonstrate the importance of the non-Newtonian behaviour: for the flow regimes investigated in this work, consistent with those in blood micro vessels, we find that the field strength needed to absorb a certain amount of particles in a non-Newtonian fluid has to be larger than the one needed in a Newtonian fluid. Specifically, for one case examined, a two times larger magnetic force had to be applied in the Ellis fluid than in the Newtonian fluid for the same number of particles to be absorbed through the vessel wall. Consequently, models based on a Newtonian fluid can drastically overestimate the effect of a magnetic field. Finally, we evaluate the particle concentration at the vessel wall and compute the evolution of the particle flux through the wall for different permeability values, as that is important when assessing the efficacy of drug delivery applications. The insights from our work bring us a step closer to successfully transferring magnetic nanoparticle drug delivery to the clinic.
△ Less
Submitted 29 August, 2022; v1 submitted 7 February, 2021;
originally announced February 2021.
-
Switchable Dam** for a One-Particle Oscillator
Authors:
X. Fan,
S. E. Fayer,
T. G. Myers,
B. A. D. Sukra,
G. Nahal,
G. Gabrielse
Abstract:
The possibility to switch the dam** rate for a one-electron oscillator is demonstrated, for an electron that oscillates along the magnetic field axis in a Penning trap. Strong axial dam** can be switched on to allow this oscillation to be used for quantum nondemolition detection of the cyclotron and spin quantum state of the electron. Weak axial dam** can be switched on to circumvent the bac…
▽ More
The possibility to switch the dam** rate for a one-electron oscillator is demonstrated, for an electron that oscillates along the magnetic field axis in a Penning trap. Strong axial dam** can be switched on to allow this oscillation to be used for quantum nondemolition detection of the cyclotron and spin quantum state of the electron. Weak axial dam** can be switched on to circumvent the backaction of the detection motion that has limited past measurements. The newly developed switch will reduce the linewidth of the cyclotron transition of one-electron by two orders of magnitude.
△ Less
Submitted 31 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
Mass transfer from a fluid flowing through a porous media
Authors:
T. G. Myers,
F. Font
Abstract:
A mathematical model is developed for the process of mass transfer from a fluid flowing through a packed column. Mass loss, whether by absorption or adsorption, may be significant. This is appropriate for example when removing contaminants from flue gases. With small mass loss the model reduces to a simpler form which is appropriate to describe the removal of contaminants/pollutants from liquids.…
▽ More
A mathematical model is developed for the process of mass transfer from a fluid flowing through a packed column. Mass loss, whether by absorption or adsorption, may be significant. This is appropriate for example when removing contaminants from flue gases. With small mass loss the model reduces to a simpler form which is appropriate to describe the removal of contaminants/pollutants from liquids. A case study is carried out for the removal of CO2 from a gas mixture passing over activated carbon. Using the experimental parameter values it is shown, via non-dimensionalisation, that certain terms may be neglected from the governing equations, resulting in a form which may be solved analytically using a travelling wave substitution. From this all important quantities throughout the column may be described; concentration of gaseous materials, amount of material available for mass transfer, fluid velocity and pressure. Results are verified by comparison with experimental data for the breakthrough curve (the amount of carbon measured at the column outlet). The advantage of the analytical expression over a purely numerical solution is that it can easily be used to optimise the process. In the final section we demonstrate how the model may be further reduced when small amounts of contaminant are removed. The model is shown to exhibit better agreement than established models when compared to experimental data for the removal of amoxicillin and congo red dye from water.
△ Less
Submitted 18 September, 2020;
originally announced September 2020.
-
Mathematical modelling of carbon capture in a packed column by adsorption
Authors:
T. G. Myers,
F. Font,
M. G. Hennessy
Abstract:
A mathematical model of the process of carbon capture in a packed column by adsorption is developed and analysed. First a detailed study is made of the governing equations. Due to the complexity of the internal geometry it is standard practice to average these equations. Here the averaging process is revisited. This shows that there exists a number of errors and some confusion in the standard syst…
▽ More
A mathematical model of the process of carbon capture in a packed column by adsorption is developed and analysed. First a detailed study is made of the governing equations. Due to the complexity of the internal geometry it is standard practice to average these equations. Here the averaging process is revisited. This shows that there exists a number of errors and some confusion in the standard systems studied in the literature. These errors affect the parameter estimation, with consequences when the experimental set-up is modified or scaled-up. Assuming, as a first approximation, an isothermal model the gas concentration equation is solved numerically. Excellent agreement with data from a pressure swing adsorption experiment is demonstrated. A new analytical solution (valid away from the inlet) is obtained. This provides explicit relations for quantities such as the amount of adsorbed gas, time of first breakthrough, total process time and width and speed of the reaction zone, showing how these depend on the operating conditions and material parameters. The relations show clearly how to optimise the carbon capture process. By comparison with experimental data the analytical solution may also be used to calculate unknown system parameters.
△ Less
Submitted 14 September, 2020; v1 submitted 9 September, 2020;
originally announced September 2020.
-
Towards an Improved Test of the Standard Model's Most Precise Prediction
Authors:
G. Gabrielse,
S. E. Fayer,
T. G. Myers,
X. Fan
Abstract:
The electron and positron magnetic moments are the most precise prediction of the standard model of particle physics. The most accurate measurement of a property of an elementary particle has been made to test this result. A new experimental method is now being employed in an attempt to improve the measurement accuracy by an order of magnitude. Positrons from a "student source" now suffice for the…
▽ More
The electron and positron magnetic moments are the most precise prediction of the standard model of particle physics. The most accurate measurement of a property of an elementary particle has been made to test this result. A new experimental method is now being employed in an attempt to improve the measurement accuracy by an order of magnitude. Positrons from a "student source" now suffice for the experiment. Progress toward a new measurement is summarized.
△ Less
Submitted 9 April, 2019;
originally announced April 2019.
-
The Stefan problem with variable thermophysical properties and phase change temperature
Authors:
Timothy G. Myers,
Matthew G. Hennessy,
Marc Calvo-Schwarzwälder
Abstract:
In this paper we formulate a Stefan problem appropriate when the thermophysical properties are distinct in each phase and the phase-change temperature is size or velocity dependent. Thermophysical properties invariably take different values in different material phases but this is often ignored for mathematical simplicity. Size and velocity dependent phase change temperatures are often found at ve…
▽ More
In this paper we formulate a Stefan problem appropriate when the thermophysical properties are distinct in each phase and the phase-change temperature is size or velocity dependent. Thermophysical properties invariably take different values in different material phases but this is often ignored for mathematical simplicity. Size and velocity dependent phase change temperatures are often found at very short length scales, such as nanoparticle melting or dendrite formation; velocity dependence occurs in the solidification of supercooled melts. To illustrate the method we show how the governing equations may be applied to a standard one-dimensional problem and also the melting of a spherically symmetric nanoparticle. Errors which have propagated through the literature are highlighted. By writing the system in non-dimensional form we are able to study the large Stefan number formulation and an energy-conserving one-phase reduction. The results from the various simplifications and assumptions are compared with those from a finite difference numerical scheme. Finally, we briefly discuss the failure of Fourier's law at very small length and time-scales and provide an alternative formulation which takes into account the finite time of travel of heat carriers (phonons) and the mean free distance between collisions.
△ Less
Submitted 11 April, 2019;
originally announced April 2019.
-
Does mathematics contribute to the nanofluid debate?
Authors:
T. G. Myers,
H. Ribera,
V. Cregan
Abstract:
Recent experimental evidence has clearly demonstrated that nanofluids do not provide the greatly enhanced heat transfer predicted in the past. Despite seemingly conclusive proof there is still a great deal of current mathematical research asserting the opposite result. In this paper we scrutinise the mathematical work and demonstrate that the disagreement can be traced to a number of issues. These…
▽ More
Recent experimental evidence has clearly demonstrated that nanofluids do not provide the greatly enhanced heat transfer predicted in the past. Despite seemingly conclusive proof there is still a great deal of current mathematical research asserting the opposite result. In this paper we scrutinise the mathematical work and demonstrate that the disagreement can be traced to a number of issues. These include the incorrect formulation of the governing equations; the use of parameter values orders of magnitude different to the true values (some requiring nanoparticle volume fractions greater than unity and nanoparticles smaller than atoms); model choices that are based on permitting a reduction using similarity variables as opposed to representing an actual physical situation; presentation of results using different scalings for each fluid.
△ Less
Submitted 22 February, 2019;
originally announced February 2019.
-
Optical diffraction from isolated nanoparticles
Authors:
T. G. Myers,
H. Ribera,
W. S. Bacsa
Abstract:
When subjected to monochromatic incident light a nanoparticle will emit light which then interferes with the incident beam. With sufficient contrast and sufficiently close to the particle this interference pattern may be recorded with a pointed optical fiber in collection mode. It is shown that the analytic dipole model accurately reproduces the observed interference pattern. Using this model and…
▽ More
When subjected to monochromatic incident light a nanoparticle will emit light which then interferes with the incident beam. With sufficient contrast and sufficiently close to the particle this interference pattern may be recorded with a pointed optical fiber in collection mode. It is shown that the analytic dipole model accurately reproduces the observed interference pattern. Using this model and measuring only the lengths of the first two major axes of the observed elliptical fringes we are able to reproduce and quantify the fringe pattern. Importantly, we are able to locate the nanoparticle, with respect to the fibre, using only visible light in a simple experimental setup. For the case described where the image plane is of the order microns above the substrate, hence the fringe number is large, it is shown that the prediction for the particle location and fringe number is insensitive to measurement errors. The phase shift of the scattered wave, a quantity that is notoriously difficult to measure, is easily determined from the theory however it is very sensitive to errors.
△ Less
Submitted 21 February, 2019;
originally announced February 2019.
-
Modelling ultra-fast nanoparticle melting with the Maxwell-Cattaneo equation
Authors:
Matthew G. Hennessy,
Marc Calvo-Schwarzwälder,
Timothy G. Myers
Abstract:
The role of thermal relaxation in nanoparticle melting is studied using a mathematical model based on the Maxwell--Cattaneo equation for heat conduction. The model is formulated in terms of a two-phase Stefan problem. We consider the cases of the temperature profile being continuous or having a jump across the solid-liquid interface. The jump conditions are derived from the sharp-interface limit o…
▽ More
The role of thermal relaxation in nanoparticle melting is studied using a mathematical model based on the Maxwell--Cattaneo equation for heat conduction. The model is formulated in terms of a two-phase Stefan problem. We consider the cases of the temperature profile being continuous or having a jump across the solid-liquid interface. The jump conditions are derived from the sharp-interface limit of a phase-field model that accounts for variations in the thermal properties between the solid and liquid. The Stefan problem is solved using asymptotic and numerical methods. The analysis reveals that the Fourier-based solution can be recovered from the classical limit of zero relaxation time when either boundary condition is used. However, only the jump condition avoids the onset of unphysical `supersonic' melting, where the speed of the melt front exceeds the finite speed of heat propagation. These results conclusively demonstrate that the jump condition, not the continuity condition, is the most suitable for use in models of phase change based on the Maxwell--Cattaneo equation. Numerical investigations show that thermal relaxation can increase the time required to melt a nanoparticle by more than a factor of ten. Thus, thermal relaxation is an important process to include in models of nanoparticle melting and is expected to be relevant in other rapid phase-change processes.
△ Less
Submitted 13 November, 2018; v1 submitted 6 June, 2018;
originally announced June 2018.
-
Effective thermal conductivity of rectangular nanowires based on phonon hydrodynamics
Authors:
Marc Calvo-Schwarzwälder,
Matthew G. Hennessy,
Pol Torres,
Timothy G. Myers,
F. Xavier Alvarez
Abstract:
A mathematical model is presented for thermal transport in nanowires with rectangular cross sections. Expressions for the effective thermal conductivity of the nanowire across a range of temperatures and cross-sectional aspect ratios are obtained by solving the Guyer--Krumhansl hydrodynamic equation for the thermal flux with a slip boundary condition. Our results show that square nanowires transpo…
▽ More
A mathematical model is presented for thermal transport in nanowires with rectangular cross sections. Expressions for the effective thermal conductivity of the nanowire across a range of temperatures and cross-sectional aspect ratios are obtained by solving the Guyer--Krumhansl hydrodynamic equation for the thermal flux with a slip boundary condition. Our results show that square nanowires transport thermal energy more efficiently than rectangular nanowires due to optimal separation between the boundaries. However, circular nanowires are found to be even more efficient than square nanowires due to the lack of corners in the cross section, which locally reduce the thermal flux and inhibit the conduction of heat. By using a temperature-dependent slip coefficient, we show that the model is able to accurately capture experimental data of the effective thermal conductivity obtained from Si nanowires, demonstrating that phonon hydrodynamics is a powerful framework that can be applied to nanosystems even at room temperature.
△ Less
Submitted 3 June, 2018; v1 submitted 31 May, 2018;
originally announced May 2018.
-
Asymptotic reduction of a porous electrode model for lithium-ion batteries
Authors:
Iain R. Moyles,
Matthew G. Hennessy,
Timothy G. Myers,
Brian R. Wetton
Abstract:
We present a porous electrode model for lithium-ion batteries using Butler--Volmer reaction kinetics. We model lithium concentration in both the solid and fluid phase along with solid and liquid electric potential. Through asymptotic reduction, we show that the electric potentials are spatially homogeneous which decouples the problem into a series of time-dependent problems. These problems can be…
▽ More
We present a porous electrode model for lithium-ion batteries using Butler--Volmer reaction kinetics. We model lithium concentration in both the solid and fluid phase along with solid and liquid electric potential. Through asymptotic reduction, we show that the electric potentials are spatially homogeneous which decouples the problem into a series of time-dependent problems. These problems can be solved on three distinguished time scales, an early time scale where capacitance effects in the electrode dominate, a mid-range time scale where a spatial concentration gradient forms in the electrolyte, and a long-time scale where each of the electrodes saturate and deplete with lithium respectively. The solid-phase concentration profiles are linear functions of time and the electrolyte potential is everywhere zero, which allows the model to be reduced to a system of two uncoupled ordinary differential equations. Analytic and numerical results are compared with full numerical simulations and experimental discharge curves demonstrating excellent agreement.
△ Less
Submitted 30 May, 2019; v1 submitted 18 May, 2018;
originally announced May 2018.