-
Letter of Intent: the NA60+ experiment
Authors:
C. Ahdida,
G. Alocco,
F. Antinori,
M. Arba,
M. Aresti,
R. Arnaldi,
A. Baratto Roldan,
S. Beole,
A. Beraudo,
J. Bernhard,
L. Bianchi,
M. Borysova,
S. Bressler,
S. Bufalino,
E. Casula,
C. Cicalo,
S. Coli,
P. Cortese,
A. Dainese,
H. Danielsson,
A. De Falco,
K. Dehmelt,
A. Drees,
A. Ferretti,
F. Fionda
, et al. (37 additional authors not shown)
Abstract:
We propose a new fixed-target experiment for the study of electromagnetic and hard probes of the Quark-Gluon Plasma (QGP) in heavy-ion collisions at the CERN SPS. The experiment aims at performing measurements of the dimuon spectrum from threshold up to the charmonium region, and of hadronic decays of charm and strange hadrons. It is based on a muon spectrometer, which includes a toroidal magnet a…
▽ More
We propose a new fixed-target experiment for the study of electromagnetic and hard probes of the Quark-Gluon Plasma (QGP) in heavy-ion collisions at the CERN SPS. The experiment aims at performing measurements of the dimuon spectrum from threshold up to the charmonium region, and of hadronic decays of charm and strange hadrons. It is based on a muon spectrometer, which includes a toroidal magnet and six planes of tracking detectors, coupled to a vertex spectrometer, equipped with Si MAPS immersed in a dipole field. High luminosity is an essential requirement for the experiment, with the goal of taking data with 10$^6$ incident ions/s, at collision energies ranging from $\sqrt{s_{\rm NN}} = 6.3$ GeV ($E_{\rm lab}= 20$ A GeV) to top SPS energy ($\sqrt{s_{\rm NN}} = 17.3$ GeV, $E_{\rm lab}= 158$ A GeV). This document presents the physics motivation, the foreseen experimental set-up including integration and radioprotection studies, the current detector choices together with the status of the corresponding R&D, and the outcome of physics performance studies. A preliminary cost evaluation is also carried out.
△ Less
Submitted 29 December, 2022;
originally announced December 2022.
-
First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors
Authors:
ALICE ITS project,
:,
G. Aglieri Rinella,
M. Agnello,
B. Alessandro,
F. Agnese,
R. S. Akram,
J. Alme,
E. Anderssen,
D. Andreou,
F. Antinori,
N. Apadula,
P. Atkinson,
R. Baccomi,
A. Badalà,
A. Balbino,
C. Bartels,
R. Barthel,
F. Baruffaldi,
I. Belikov,
S. Beole,
P. Becht,
A. Bhatti,
M. Bhopal,
N. Bianchi
, et al. (230 additional authors not shown)
Abstract:
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra…
▽ More
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.
△ Less
Submitted 17 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
Charge collection properties of TowerJazz 180 nm CMOS Pixel Sensors in dependence of pixel geometries and bias parameters, studied using a dedicated test-vehicle: the Investigator chip
Authors:
G. Aglieri Rinella,
G. Chaosong,
A. di Mauro,
J. Eum,
H. Hillemanns,
A. Junique,
M. Keil,
D. Kim,
H. Kim,
T. Kugathasan,
S. Lee,
M. Mager,
V. Manzari,
C. A. Marin Tobon,
P. Martinengo,
H. Mugnier,
L. Musa,
F. Reidt,
J. Rousset,
K. Sielewicz,
W. Snoeys,
M. Šuljić,
J. W. van Hoorne,
Q. M. Waheed,
P. Yang
, et al. (1 additional authors not shown)
Abstract:
This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation…
▽ More
This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation Inner Tracking System of ALICE, and serve as reference for future simulation studies of similar devices. The studied parameters include: reverse substrate bias, epitaxial layer thickness, charge collection electrode size and the spacing of the electrode to surrounding in-pixel electronics. The results from pixels of 28 um pitch confirm that even in partially depleted circuits, charge collection can be fast (<10 ns), and quantify the influence of the parameters onto the signal sharing and amplitudes, highlighting the importance of a correct spacing between wells and of the impact of the reverse substrate bias.
△ Less
Submitted 23 September, 2020; v1 submitted 22 September, 2020;
originally announced September 2020.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
A next-generation LHC heavy-ion experiment
Authors:
D. Adamová,
G. Aglieri Rinella,
M. Agnello,
Z. Ahammed,
D. Aleksandrov,
A. Alici,
A. Alkin,
T. Alt,
I. Altsybeev,
D. Andreou,
A. Andronic,
F. Antinori,
P. Antonioli,
H. Appelshäuser,
R. Arnaldi,
I. C. Arsene,
M. Arslandok,
R. Averbeck,
M. D. Azmi,
X. Bai,
R. Bailhache,
R. Bala,
L. Barioglio,
G. G. Barnaföldi,
L. S. Barnby
, et al. (374 additional authors not shown)
Abstract:
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with th…
▽ More
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with the innermost layers possibly positioned inside the beam pipe. In addition to superior tracking and vertexing capabilities over a wide momentum range down to a few tens of MeV/$c$, the detector will provide particle identification via time-of-flight determination with about 20~ps resolution. In addition, electron and photon identification will be performed in a separate shower detector. The proposed detector is conceived for studies of pp, pA and AA collisions at luminosities a factor of 20 to 50 times higher than possible with the upgraded ALICE detector, enabling a rich physics program ranging from measurements with electromagnetic probes at ultra-low transverse momenta to precision physics in the charm and beauty sector.
△ Less
Submitted 2 May, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.
-
The PreAmplifier ShAper for the ALICE TPC-Detector
Authors:
H. K. Soltveit,
J. Stachel,
P. Braun-Munzinger,
L. Musa,
H. A. Gustafsson,
U. Bonnes,
H. Oeschler,
L. Osterman,
S. Lang
Abstract:
In this paper the PreAmplifier ShAper (PASA) for the Time Projection Chamber (TPC) of the ALICE experiment at LHC is presented. The ALICE TPC PASA is an ASIC that integrates 16 identical channels, each consisting of Charge Sensitive Amplifiers (CSA) followed by a Pole-Zero network, self-adaptive bias network, two second-order bridged-T filters, two non-inverting level shifters and a start-up circu…
▽ More
In this paper the PreAmplifier ShAper (PASA) for the Time Projection Chamber (TPC) of the ALICE experiment at LHC is presented. The ALICE TPC PASA is an ASIC that integrates 16 identical channels, each consisting of Charge Sensitive Amplifiers (CSA) followed by a Pole-Zero network, self-adaptive bias network, two second-order bridged-T filters, two non-inverting level shifters and a start-up circuit. The circuit is optimized for a detector capacitance of 18-25 pF. For an input capacitance of 25 pF, the PASA features a conversion gain of 12.74 mV/fC, a peaking time of 160 ns, a FWHM of 190 ns, a power consumption of 11.65 mW/ch and an equivalent noise charge of 244e + 17e/pF. The circuit recovers smoothly to the baseline in about 600 ns. An integral non-linearity of 0.19% with an output swing of about 2.1 V is also achieved. The total area of the chip is 18 mm$^2$ and is implemented in AMS's C35B3C1 0.35 micron CMOS technology. Detailed characterization test were performed on about 48000 PASA circuits before mounting them on the ALICE TPC front-end cards. After more than two years of operation of the ALICE TPC with p-p and Pb-Pb collisions, the PASA has demonstrated to fulfill all requirements.
△ Less
Submitted 15 March, 2012;
originally announced March 2012.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Measurement of single event upsets in the ALICE-TPC front-end electronics
Authors:
M. Mager,
L. Musa,
A. Rehman,
A. Szczepankiewicz
Abstract:
The Time Projection Chamber of the ALICE experiment at the CERN Large Hadron Collider features highly integrated on-detector read-out electronics. It is following the general trend of high energy physics experiments by placing the front-end electronics as close to the detector as possible -- only some 10 cm away from its active volume. Being located close to the beams and the interaction region, t…
▽ More
The Time Projection Chamber of the ALICE experiment at the CERN Large Hadron Collider features highly integrated on-detector read-out electronics. It is following the general trend of high energy physics experiments by placing the front-end electronics as close to the detector as possible -- only some 10 cm away from its active volume. Being located close to the beams and the interaction region, the electronics is subject to a moderate radiation load, which allowed us to use commercial off-the-shelf components. However, they needed to be selected and qualified carefully for radiation hardness and means had to be taken to protect their functionality against soft errors, i.e. single event upsets.
Here we report on the first measurements of LHC induced radiation effects on ALICE front-end electronics and on how they attest to expectations.
△ Less
Submitted 14 October, 2011;
originally announced October 2011.
-
The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
Authors:
J. Alme,
Y. Andres,
H. Appelshauser,
S. Bablok,
N. Bialas,
R. Bolgen,
U. Bonnes,
R. Bramm,
P. Braun-Munzinger,
R. Campagnolo,
P. Christiansen,
A. Dobrin,
C. Engster,
D. Fehlker,
P. Foka,
U. Frankenfeld,
J. J. Gaardhoje,
C. Garabatos,
P. Glassel,
C. Gonzalez Gutierrez,
P. Gros,
H. -A. Gustafsson,
H. Helstrup,
M. Hoch,
M. Ivanov
, et al. (51 additional authors not shown)
Abstract:
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we des…
▽ More
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.
△ Less
Submitted 12 January, 2010;
originally announced January 2010.
-
The CAST Time Projection Chamber
Authors:
D. Autiero,
B. Beltran,
J. M. Carmona,
S. Cébrian,
E. Chesi,
M. Davenport,
M. Delattre,
L. Di Lella,
F. Formenti,
I. G. Irastorza,
H. Gomez,
M. Hasinoff,
B. Lakić,
G. Luzón,
J. Morales,
L. Musa,
A. Ortiz,
A. Placci,
A. Rodriguez,
J. Ruz,
J. A. Villar,
K. Zioutas
Abstract:
One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data…
▽ More
One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data taking periods, and the overall efficiency for the detection of photons coming from conversion of solar axions is 62 %. Shielding has been installed around the detector, lowering the background level to 4.10 x 10^-5 counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment the TPC has provided robust and stable operation, thus contributing with a competitive result to the overall CAST limit on axion-photon coupling and mass.
△ Less
Submitted 22 February, 2007;
originally announced February 2007.