-
Longitudinal spin-relaxation optimization for miniaturized optically pumped magnetometers
Authors:
A. P. McWilliam,
S. Dyer,
D. Hunter,
M. Mrozowski,
S. J. Ingleby,
O. Sharp,
D. P. Burt,
P. F. Griffin,
J. P. McGilligan,
E. Riis
Abstract:
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal re…
▽ More
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, $γ_{10}$, and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted through employing an optically pumped magnetometer operating in a free-induction-decay configuration. $γ_{10}$ is extracted across a range of nitrogen pressures between $\sim$~60~-~700~Torr, measuring a minimum of 140~Hz at 115~Torr. Additionally, we achieve sensitivities as low as 130 ~fT/$\sqrt{\text{Hz}}$ at a bias field amplitude of $\sim 50~μ$T. With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance.
△ Less
Submitted 3 July, 2024; v1 submitted 27 June, 2024;
originally announced June 2024.
-
Optical pum** enhancement of a free-induction-decay magnetometer
Authors:
Dominic Hunter,
Marcin S. Mrozowski,
Allan McWilliam,
Stuart J. Ingleby,
Terry E. Dyer,
Paul F. Griffin,
Erling Riis
Abstract:
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pum** with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed ma…
▽ More
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pum** with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed magnetic field is generated along the optical pum** axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium (Cs) vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pum** modalities across a wide magnetic field range. A noise floor sensitivity of $238\,\mathrm{fT/\surd{Hz}}$ was achieved in a field of approximately $\mathrm{50\,μ{T}}$, in close agreement with the Cramér-Rao lower bound (CRLB) predicted noise density of $258\,\mathrm{fT/\surd{Hz}}$.
△ Less
Submitted 29 September, 2023; v1 submitted 21 July, 2023;
originally announced July 2023.
-
Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell
Authors:
D. Hunter,
C. Perrella,
A. McWilliam,
J. P. McGilligan,
M. Mrozowski,
S. J. Ingleby,
P. F. Griffin,
D. Burt,
A. N. Luiten,
E. Riis
Abstract:
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusi…
▽ More
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N$_{2}$) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a $175\,μ$m probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43$\,\mathrm{pT/\sqrt{Hz}}$ within a Nyquist limited bandwidth of $500\,$Hz. Furthermore, the sensor's dynamic range exceeds the Earth's field of approximately $50\,μ$T, which provides a framework for magnetic field imaging in unshielded environments.
△ Less
Submitted 29 September, 2023; v1 submitted 20 March, 2023;
originally announced March 2023.
-
High-efficiency coupled-cavity optical frequency comb generation
Authors:
Mateusz P. Mrozowski,
Jonathan D. Pritchard,
J. Jeffers
Abstract:
We present a high efficiency source of picosecond pulses derived from a dual cavity optical frequency comb generator. This approach overcomes the limitations of single cavity comb generators that are restricted to efficiencies of a few percent. We achieve picosecond pulses with GHz repetition rates offering over a hundred times higher output efficiency than a single cavity design and demonstrate t…
▽ More
We present a high efficiency source of picosecond pulses derived from a dual cavity optical frequency comb generator. This approach overcomes the limitations of single cavity comb generators that are restricted to efficiencies of a few percent. We achieve picosecond pulses with GHz repetition rates offering over a hundred times higher output efficiency than a single cavity design and demonstrate tuning of pulse width by varying the modulation depth of the intra-cavity electro-optic modulator. These results provide a wavelength-agnostic design with a compact footprint for the development of portable picosecond pulsed laser systems for timing, metrology, and LIDAR applications.
△ Less
Submitted 20 February, 2023; v1 submitted 23 November, 2022;
originally announced November 2022.
-
A Digital Alkali Spin Maser
Authors:
Stuart Ingleby,
Paul Griffin,
Terry Dyer,
Marcin Mrozowski,
Erling Riis
Abstract:
Self-oscillating atomic magnetometers, in which the precession of atomic spins in a magnetic field is driven by resonant modulation, offer high sensitivity and dynamic range. Phase-coherent feedback from the detected signal to the applied modulation creates a resonant spin maser system, highly responsive to changes in the background magnetic field. Here we show a system in which the phase conditio…
▽ More
Self-oscillating atomic magnetometers, in which the precession of atomic spins in a magnetic field is driven by resonant modulation, offer high sensitivity and dynamic range. Phase-coherent feedback from the detected signal to the applied modulation creates a resonant spin maser system, highly responsive to changes in the background magnetic field. Here we show a system in which the phase condition for resonant precession is met by digital signal processing integrated into the maser feedback loop. This system uses a modest chip-scale laser and mass-produced dual-pass caesium vapour cell and operates in a 50 microtesla field, making it a suitable technology for portable measurements of the geophysical magnetic field. We demonstrate a Cramer-Rao lower bound-limited resolution of 50 fT at 1 s sampling cadence, and a sensor bandwidth of 10 kHz. This device also represents an important class of atomic system in which low-latency digital processing forms an integral part of a coherently-driven quantum system.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
Ultra-low noise, bi-polar, programmable current sources
Authors:
M. S. Mrozowski,
I. C. Chalmers,
S. J. Ingleby,
P. F. Griffin,
E. Riis
Abstract:
We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of $\pm$~10~mA and $\pm$~250~mA…
▽ More
We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of $\pm$~10~mA and $\pm$~250~mA respectively on three independent channels with 16-bit resolution. Both devices feature narrow 1/f noise bandwidth of 1~Hz, enabling magnetic field manipulation for high-performance OPMs. They exhibit low noise of 146.3~pA/$\sqrt{\mathrm{Hz}}$ and 4114~pA/$\sqrt{\mathrm{Hz}}$ which translates to 14.57~ppb/$\sqrt{\mathrm{Hz}}$ and 16.46~ppb/$\sqrt{\mathrm{Hz}}$ noise relative to full scale.
△ Less
Submitted 22 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
A practical compact source of heralded single photons for simple detection LIDAR
Authors:
Mateusz P. Mrozowski,
John Jeffers,
Jonathan D. Pritchard
Abstract:
Optical quantum technologies such as quantum sensing, quantum cryptography and quantum computation all utilize properties of non-classical light, such as precise photon-number and entangled photon-pair states, to surpass technologies based on the classical light. A common route for obtaining heralded single photons is spontaneous four-wave mixing in optical fibers, allowing for a well-defined spat…
▽ More
Optical quantum technologies such as quantum sensing, quantum cryptography and quantum computation all utilize properties of non-classical light, such as precise photon-number and entangled photon-pair states, to surpass technologies based on the classical light. A common route for obtaining heralded single photons is spontaneous four-wave mixing in optical fibers, allowing for a well-defined spatial mode, for high efficiency integration into optical fiber networks. These fibers are typically pumped using large, commercial, pulsed lasers requiring high-power (~10 W) pump lasers and are limited to ~MHz repetition rate. Here we propose a cost-efficient, compact and mobile alternative. Photon pairs at 660 nm and 960 nm will be created using four-wave mixing in commercial birefringent optical fiber, pumped using transform limited picosecond pulses with GHz repetition rates derived from a 785 nm CW laser diode using cavity-enhanced optical frequency comb generation. The pulses are predicted to have average power of 275 mW, a peak power of >40 W, and predicted photon yield of >2000 pairs detected per second. This design will be later utilized to implement a quantum illumination scheme based on a coincidence count between idler and signal photons - instead of joint measurement between signal and idler. This will allow for quantum advantage over classic LIDAR without the requirement for maintaining an interferometric stability in free space.
△ Less
Submitted 5 September, 2021;
originally announced September 2021.