-
Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors
Authors:
C. Agapopoulou,
S. Blin,
A. Blot,
L. Castillo Garcia,
M. Chmeissani,
S. Conforti di Lorenzo,
C. de La Taille,
P. Dinaucourt,
A. Fallou,
J. Garcia Rodriguez,
V. Gkougkousis,
C. Grieco,
S. Grinstein,
S. Guindon,
N. Makovec,
G. Martin-Chassard,
G. Pellegrini,
A. Rummler,
S. Sacerdoti,
N. Seguin Moreau,
L. Serin,
A. Tricoli
Abstract:
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the perfo…
▽ More
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the performance of the sensor, while kee** low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2$\times$2 LGAD array of 1.1$\times$1.1 mm$^2$ pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect that arises from the different response of the preamplifier for various injected charges can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.
△ Less
Submitted 7 July, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
High rate, fast timing Glass RPC for the high η CMS muon detectors
Authors:
F. Lagarde,
M. Gouzevitch,
I. Laktineh,
V. Buridon,
X. Chen,
C. Combaret,
A. Eynard,
L. Germani,
G. Grenier,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
W. Tromeuraa,
Y. Wang,
A. Gongab,
N. Moreau,
C. de la Taille,
F. Dulucqac,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat
, et al. (86 additional authors not shown)
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high $η$ muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.
△ Less
Submitted 22 July, 2016; v1 submitted 4 June, 2016;
originally announced June 2016.
-
High rate, fast timing Glass RPC for the high $η$ CMS muon detectors
Authors:
Maxime Gouzevitch,
François Lagarde,
Imad Laktineh,
Victor Buridon,
Xiushan Chen,
Christophe Combaret,
Alexis Eynard,
Lionel Germani,
Gerald Grenier,
Hervé Mathez,
Laurent Mirabito,
Alexei Petrukhin,
Arnaud Steen,
William Tromeur,
Yi Wang,
Fuyue Wang,
Nathalie Moreau,
Christophe de la Taille,
Fréderic Dulucq
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6 \cdot 10^{34}$ cm$^{-2}$s$^{-1}$. The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of t…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6 \cdot 10^{34}$ cm$^{-2}$s$^{-1}$. The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz/cm$^2$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. A new generation Glass-RPC (GRPC) using low resistivity glass (LR) is proposed to equip at least the two most far away of the four high eta muon stations of CMS. The design of small size prototypes and the studies of their performances under high rate particles flux is presented.
△ Less
Submitted 3 June, 2016;
originally announced June 2016.
-
New model for datasets citation and extraction reproducibility in VAMDC
Authors:
Carlo Maria Zwölf,
Nicolas Moreau,
Marie-Lise Dubernet
Abstract:
In this paper we present a new paradigm for the identification of datasets extracted from the Virtual Atomic and Molecular Data Centre (VAMDC) e-science infrastructure. Such identification includes information on the origin and version of the datasets, references associated to individual data in the datasets, as well as timestamps linked to the extraction procedure. This paradigm is described thro…
▽ More
In this paper we present a new paradigm for the identification of datasets extracted from the Virtual Atomic and Molecular Data Centre (VAMDC) e-science infrastructure. Such identification includes information on the origin and version of the datasets, references associated to individual data in the datasets, as well as timestamps linked to the extraction procedure. This paradigm is described through the modifications of the language used to exchange data within the VAMDC and through the services that will implement those modifications. This new paradigm should enforce traceability of datasets, favour reproducibility of datasets extraction, and facilitate the systematic citation of the authors having originally measured and/or calculated the extracted atomic and molecular data.
△ Less
Submitted 9 May, 2016;
originally announced June 2016.
-
The STARK-B database as a resource for \textquotedblleft STARK" widths and shifts data: State of advancement and program of development
Authors:
Sylvie Sahal-Bréchot,
Milan S. Dimitrijević,
Nicolas Moreau,
Nabil Ben Nessib
Abstract:
\textquotedblleft Stark" broadening theories and calculations have been extensively developed for about 50 years and can now be applied to many needs, especially for accurate spectroscopic diagnostics and modeling. This requires the knowledge of numerous collisional line profiles. Nowadays, the access to such data via an online database becomes essential. STARK-B is a collaborative project between…
▽ More
\textquotedblleft Stark" broadening theories and calculations have been extensively developed for about 50 years and can now be applied to many needs, especially for accurate spectroscopic diagnostics and modeling. This requires the knowledge of numerous collisional line profiles. Nowadays, the access to such data via an online database becomes essential. STARK-B is a collaborative project between the Astronomical Observatory of Belgrade and the Laboratoire d'Étude du Rayonnement et de la matière en Astrophysique (LERMA). It is a database of calculated widths and shifts of isolated lines of atoms and ions due to electron and ion collisions (impacts). It is devoted to modeling and spectroscopic diagnostics of stellar atmospheres and envelopes, laboratory plasmas, laser equipments and technological plasmas. Hence, the domain of temperatures and densities covered by the tables is wide and depends on the ionization degree of the considered ion. STARK-B has been fully opened since September 2008 and is in free access.
The first stage of development was ended in autumn 2012, since all the existing data calculated with the impact semiclassical-perturbation method and code by Sahal-Bréchot, Dimitrijević and coworkers have now been implemented. We are now beginning the second stage of the development of STARK-B. The state of advancement of the database and our program of development are presented here, together with its context within VAMDC. VAMDC (Virtual Atomic and Molecular Data Center) is an international consortium which has built a secure, documented, flexible interoperable platform e-science permitting an automated exchange of atomic and molecular data.
△ Less
Submitted 12 November, 2013;
originally announced November 2013.