-
Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons
Authors:
B. M. Latacz,
M. Fleck,
J. I. Jaeger,
G. Umbrazunas,
B. P. Arndt,
S. R. Erlewein,
E. J. Wursten,
J. A. Devlin,
P. Micke,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
A. Soter,
W. Quint,
J. Walz,
Y. Yamazaki,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we dem…
▽ More
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios
Authors:
M. J. Borchert,
J. A. Devlin,
S. E. Erlewein,
M. Fleck,
J. A. Harrington,
T. Higuchi,
B. Latacz,
F. Voelksen,
E. Wursten,
F. Abbass,
M. Bohman,
A. Mooser,
D. Popper,
M. Wiesinger,
C. Will,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
C. Smorra,
S. Ulmer
Abstract:
The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental propert…
▽ More
The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, $-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}}$ = $1.000\,000\,000\,003 (16)$, is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of $1.96\cdot10^{-27}\,$GeV (C$.$L$.$ 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP$_\text{cc}$) for antimatter to a level of $|α_{g}-1| < 1.8 \cdot 10^{-7}$, and enables the first differential test of the WEP$_\text{cc}$ using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP$_\text{cc}$-violating coefficient to $|α_{g,D}-1|<0.030$.
△ Less
Submitted 27 November, 2023;
originally announced November 2023.
-
Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature
Authors:
C. Will,
M. Wiesinger,
P. Micke,
H. Yildiz,
T. Driscoll,
S. Kommu,
F. Abbass,
B. P. Arndt,
B. B. Bauer,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
A. Mooser,
D. Schweitzer,
G. Umbrazunas,
E. Wursten,
K. Blaum,
J. A. Devlin,
C. Ospelkaus,
W. Quint,
A. Soter,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a mileston…
▽ More
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Ultra thin polymer foil cryogenic window for antiproton deceleration and storage
Authors:
B. M. Latacz,
B. P. Arndt,
J. A. Devlin,
S. R. Erlewein,
M. Fleck,
J. I. Jäger,
P. Micke,
G. Umbrazunas,
E. Wursten,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
C. Smorra,
A. Sótér,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons thro…
▽ More
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap
Authors:
Markus Wiesinger,
Florian Stuhlmann,
Matthew A. Bohman,
Peter Micke,
Christian Will,
Hüseyin Yildiz,
Fatma Abbass,
Bela P. Arndt,
Jack A. Devlin,
Stefan Erlewein,
Markus Fleck,
Julia I. Jäger,
Barbara M. Latacz,
Daniel Schweitzer,
Gilbertas Umbrazunas,
Elise Wursten,
Klaus Blaum,
Yasuyuki Matsuda,
Andreas Mooser,
Wolfgang Quint,
Anna Soter,
Jochen Walz,
Christian Smorra,
Stefan Ulmer
Abstract:
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at ro…
▽ More
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Authors:
C. Smorra,
F. Abbass,
M. Bohman,
Y. Dutheil,
A. Hobl,
D. Popper,
B. Arndt,
B. B. Bauer,
J. A. Devlin,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
P. Micke,
M. Schiffelholz,
G. Umbrazunas,
M. Wiesinger,
C. Will,
E. Wursten,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
W. Quint
, et al. (4 additional authors not shown)
Abstract:
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To…
▽ More
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pum** section to suppress the residual gas flow into the cryogenic trap chamber.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Direct measurement of the $^3$He$^+$ magnetic moments
Authors:
A. Schneider,
B. Sikora,
S. Dickopf,
M. Müller,
N. S. Oreshkina,
A. Rischka,
I. A. Valuev,
S. Ulmer,
J. Walz,
Z. Harman,
C. H. Keitel,
A. Mooser,
K. Blaum
Abstract:
Helium-3 has nowadays become one of the most important candidates for studies in fundamental physics [1, 2, 3], nuclear and atomic structure [4, 5], magnetometry and metrology [6] as well as chemistry and medicine [7, 8]. In particular, $^3$He nuclear magnetic resonance (NMR) probes have been proposed as a new standard for absolute magnetometry [6, 9]. This requires a high-accuracy value for the…
▽ More
Helium-3 has nowadays become one of the most important candidates for studies in fundamental physics [1, 2, 3], nuclear and atomic structure [4, 5], magnetometry and metrology [6] as well as chemistry and medicine [7, 8]. In particular, $^3$He nuclear magnetic resonance (NMR) probes have been proposed as a new standard for absolute magnetometry [6, 9]. This requires a high-accuracy value for the $^3$He nuclear magnetic moment, which, however, has so far been determined only indirectly and with a relative precision of $12$ parts per billon (p.p.b.) [10,11]. Here we investigate the $^3$He$^+$ ground-state hyperfine structure in a Penning trap to directly measure the nuclear $g$-factor of $^3$He$^+$ $g'_I=-4.255\, 099\, 606\, 9(30)_{stat}(17)_{sys}$, the zero-field hyperfine splitting $E_{\rm HFS}^{\rm exp}=-8\, 665\, 649\, 865.77(26)_{stat}(1)_{sys}$ Hz and the bound electron $g$-factor $g_e^\text{exp}=-2.002\, 177\, 415\, 79(34)_{stat}(30)_{sys}$. The latter is consistent with our theoretical value $g_e^\text{theo}=-2.002\, 177\, 416\, 252\, 23(39)$ based on parameters and fundamental constants from [12]. Our measured value for the $^3$He$^+$ nuclear $g$-factor allows for the determination of the $g$-factor of the bare nucleus $g_I=-4.255\, 250\, 699\, 7(30)_{stat}(17)_{sys}(1)_{theo}$ via our accurate calculation of the diamagnetic shielding constant [13] $σ_{^3He^+}=0.000\,035\,507\,38(3)$. This constitutes the first direct calibration for $^3$He NMR probes and an improvement of the precision by one order of magnitude compared to previous indirect results. The measured zero-field hyperfine splitting improves the precision by two orders of magnitude compared to the previous most precise value [14] and enables us to determine the Zemach radius [15] to $r_Z=2.608(24)$ fm.
△ Less
Submitted 13 June, 2022;
originally announced June 2022.
-
Implementation of AI/Deep Learning Disruption Predictor into a Plasma Control System
Authors:
William Tang,
Ge Dong,
Jayson Barr,
Keith Erickson,
Rory Conlin,
M. Dan Boyer,
Julian Kates-Harbeck,
Kyle Felker,
Cristina Rea,
Nikolas C. Logan,
Alexey Svyatkovskiy,
Eliot Feibush,
Joseph Abbatte,
Mitchell Clement,
Brian Grierson,
Raffi Nazikian,
Zhihong Lin,
David Eldon,
Auna Moser,
Mikhail Maslov
Abstract:
This paper reports on advances to the state-of-the-art deep-learning disruption prediction models based on the Fusion Recurrent Neural Network (FRNN) originally introduced a 2019 Nature publication. In particular, the predictor now features not only the disruption score, as an indicator of the probability of an imminent disruption, but also a sensitivity score in real-time to indicate the underlyi…
▽ More
This paper reports on advances to the state-of-the-art deep-learning disruption prediction models based on the Fusion Recurrent Neural Network (FRNN) originally introduced a 2019 Nature publication. In particular, the predictor now features not only the disruption score, as an indicator of the probability of an imminent disruption, but also a sensitivity score in real-time to indicate the underlying reasons for the imminent disruption. This adds valuable physics-interpretability for the deep-learning model and can provide helpful guidance for control actuators now that it is fully implemented into a modern Plasma Control System (PCS). The advance is a significant step forward in moving from modern deep-learning disruption prediction to real-time control and brings novel AI-enabled capabilities relevant for application to the future burning plasma ITER system. Our analyses use large amounts of data from JET and DIII-D vetted in the earlier NATURE publication. In addition to when a shot is predicted to disrupt, this paper addresses reasons why by carrying out sensitivity studies. FRNN is accordingly extended to use many more channels of information, including measured DIII-D signals such as (i) the n1rms signal that is correlated with the n =1 modes with finite frequency, including neoclassical tearing mode and sawtooth dynamics, (ii) the bolometer data indicative of plasma impurity content, and (iii) q-min, the minimum value of the safety factor relevant to the key physics of kink modes. The additional channels and interpretability features expand the ability of the deep learning FRNN software to provide information about disruption subcategories as well as more precise and direct guidance for the actuators in a plasma control system.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
Sympathetic cooling schemes for separately trapped ions coupled via image currents
Authors:
C. Will,
M. Bohman,
T. Driscoll,
M. Wiesinger,
F. Abbass,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
M. Fleck,
B. Latacz,
R. Moller,
A. Mooser,
D. Popper,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and fin…
▽ More
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Sympathetic cooling of a trapped proton mediated by an LC circuit
Authors:
M. Bohman,
V. Grunhofer,
C. Smorra,
M. Wiesinger,
C. Will,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
M. Fleck,
S. Gavranovic,
J. Harrington,
B. Latacz,
A. Mooser,
D. Popper,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
S. Ulmer
Abstract:
Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to prev…
▽ More
Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be+ ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image-current interactions, it can be easily applied to an experiment with antiprotons, facilitating improved precision in matter-antimatter comparisons and dark matter searches.
△ Less
Submitted 28 August, 2021;
originally announced August 2021.
-
Constraints on the Coupling between Axionlike Dark Matter and Photons Using an Antiproton Superconducting Tuned Detection Circuit in a Cryogenic Penning Trap
Authors:
Jack A. Devlin,
Matthias J. Borchert,
Stefan Erlewein,
Markus Fleck,
James A. Harrington,
Barbara Latacz,
Jan Warncke,
Elise Wursten,
Matthew A. Bohman,
Andreas H. Mooser,
Christian Smorra,
Markus Wiesinger,
Christian Will,
Klaus Blaum,
Yasuyuki Matsuda,
Christian Ospelkaus,
Wolfgang Quint,
Jochen Walz,
Yasunori Yamazaki,
Stefan Ulmer
Abstract:
We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs…
▽ More
We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs with masses around $2.7906-2.7914\,\textrm{neV/c}^2$ to $g_{aγ}< 1 \times 10^{-11}\,\textrm{GeV}^{-1}$. This is more than one order of magnitude lower than the best laboratory haloscope and approximately 5 times lower than the CERN axion solar telescope (CAST), setting limits in a mass and coupling range which is not constrained by astrophysical observations. Our approach can be extended to many other Penning-trap experiments and has the potential to provide broad limits in the low ALP mass range.
△ Less
Submitted 27 January, 2021;
originally announced January 2021.
-
Direct limits on the interaction of antiprotons with axion-like dark matter
Authors:
C. Smorra,
Y. V. Stadnik,
P. E. Blessing,
M. Bohman,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
J. A. Harrington,
T. Higuchi,
A. Mooser,
G. Schneider,
M. Wiesinger,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
D. Budker,
S. Ulmer
Abstract:
Astrophysical observations indicate that there is roughly five times more dark matter in the Universe than ordinary baryonic matter, with an even larger amount of the Universe's energy content due to dark energy. So far, the microscopic properties of these dark components have remained shrouded in mystery. In addition, even the five percent of ordinary matter in our Universe has yet to be understo…
▽ More
Astrophysical observations indicate that there is roughly five times more dark matter in the Universe than ordinary baryonic matter, with an even larger amount of the Universe's energy content due to dark energy. So far, the microscopic properties of these dark components have remained shrouded in mystery. In addition, even the five percent of ordinary matter in our Universe has yet to be understood, since the Standard Model of particle physics lacks any consistent explanation for the predominance of matter over antimatter. Inspired by these central problems of modern physics, we present here a direct search for interactions of antimatter with dark matter, and place direct constraints on the interaction of ultra-light axion-like particles $-$ one of the dark-matter candidates $-$ and antiprotons. If antiprotons exhibit a stronger coupling to these dark-matter particles than protons, such a CPT-odd coupling could provide a link between dark matter and the baryon asymmetry in the Universe. We analyse spin-flip resonance data acquired with a single antiproton in a Penning trap [Smorra et al., Nature 550, 371 (2017)] in the frequency domain to search for spin-precession effects from ultra-light axions with a characteristic frequency governed by the mass of the underlying particle. Our analysis constrains the axion-antiproton interaction parameter $f_a/C_{\overline{p}}$ to values greater than $0.1$ to $0.6$ GeV in the mass range from $2 \times 10^{-23}$ to $4 \times 10^{-17}\,$eV/$c^2$, improving over astrophysical antiproton bounds by up to five orders of magnitude. In addition, we derive limits on six combinations of previously unconstrained Lorentz-violating and CPT-violating terms of the non-minimal Standard Model Extension.
△ Less
Submitted 30 May, 2020;
originally announced June 2020.
-
Precision measurements of the fundamental properties of the proton and antiproton
Authors:
Christian Smorra,
Andreas Mooser
Abstract:
Precision measurements comparing the fundamental properties of conjugate particles and antiparticles constitute stringent tests of CPT invariance. We review recent precision measurements of the BASE collaboration, which improved the uncertainty of the proton and antiproton magnetic moments and the comparison of the proton-to-antiproton charge-to-mass ratio. These measurements constitute the most s…
▽ More
Precision measurements comparing the fundamental properties of conjugate particles and antiparticles constitute stringent tests of CPT invariance. We review recent precision measurements of the BASE collaboration, which improved the uncertainty of the proton and antiproton magnetic moments and the comparison of the proton-to-antiproton charge-to-mass ratio. These measurements constitute the most stringent tests of CPT invariance with antiprotons. Further, we discuss the improved limit on the antiproton lifetime based on the storage of a cloud of antiprotons in the unique BASE reservoir trap. Based on these recent advances, we discuss ongoing technical developments which comprise a coupling trap for the sympathetic cooling of single (anti-)protons with laser-cooled beryllium ions, a transportable trap to relocate antiproton measurements into a high-precision laboratory, and a new experiment to measure the magnetic moment of helium-3 ions, which will improve absolute precision magnetometry.
△ Less
Submitted 11 February, 2020;
originally announced February 2020.
-
Role of Poloidal $\mathbf{E}\times\mathbf{B}$ Drift in Divertor Heat Transport in DIII-D
Authors:
A. E. Järvinen,
S. L. Allen,
A. W. Leonard,
A. G. McLean,
A. L. Moser,
T. D. Rognlien,
C. M. Samuell
Abstract:
Simulations for DIII-D high confinement mode plasmas with the multifluid code UEDGE show a strong role of poloidal $\mathbf{E}\times\mathbf{B}$ drifts on divertor heat transport, challenging the paradigm of conduction limited scrape-off layer (SOL) transport. While simulations with reduced drift magnitude are well aligned with the assumption that electron heat conduction dominates the SOL heat tra…
▽ More
Simulations for DIII-D high confinement mode plasmas with the multifluid code UEDGE show a strong role of poloidal $\mathbf{E}\times\mathbf{B}$ drifts on divertor heat transport, challenging the paradigm of conduction limited scrape-off layer (SOL) transport. While simulations with reduced drift magnitude are well aligned with the assumption that electron heat conduction dominates the SOL heat transport, simulations with drifts predict that the poloidal convective $\mathbf{E}\times\mathbf{B}$ heat transport dominates over electron heat conduction in both attached and detached conditions. Since poloidal $\mathbf{E}\times\mathbf{B}$ flow propagates across magnetic field lines, poloidal transport with shallow magnetic pitch angles can reach values that are of the same order as would be provided by sonic flows parallel to the field lines. These flows can lead to strongly convection dominated divertor heat transport, increasing the poloidal volume of radiative power front, consistent with previous measurements at DIII-D. Due to these convective flows, the Lengyel integral approach, assuming zero convective fraction, is expected to provide a pessimistic estimate for radiative capability of impurities in the divertor. For the DIII-D simulations shown here, the Lengyel integral approach underestimates the radiated power by a factor of 6, indicating that for reliable DIII-D divertor power exhaust predictions, full 2D calculations, including drifts, would be necessary.
△ Less
Submitted 19 September, 2019;
originally announced September 2019.
-
Measurement of ultra-low heating rates of a single antiproton in a cryogenic Penning trap
Authors:
M. J. Borchert,
P. E. Blessing,
J. A. Devlin,
J. A. Harrington,
T. Higuchi,
J. Morgner,
C. Smorra,
E. Wursten,
M. Bohman,
M. Wiesinger,
A. Mooser,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron quantum transition rates of 6(1) quanta/h and an electric field noise spectral density below $7.5(3.4)\times 10^{-20}\,\text{V}^{2}\text{m}^{-2} \text{Hz}^{-1}$, which corresponds to a scaled noise spectral density below…
▽ More
We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron quantum transition rates of 6(1) quanta/h and an electric field noise spectral density below $7.5(3.4)\times 10^{-20}\,\text{V}^{2}\text{m}^{-2} \text{Hz}^{-1}$, which corresponds to a scaled noise spectral density below $8.8(4.0)\times 10^{-12}\,\text{V}^{2}\text{m}^{-2}$, results which are more than two orders of magnitude smaller than those reported by other ion trap experiments.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Sympathetic Cooling of Protons and Antiprotons with a Common Endcap Penning Trap
Authors:
M. Bohman,
A. Mooser,
G. Schneider,
N Schön,
M. Wiesinger,
J. Harrington,
T. Higuchi,
H. Nagahama,
S. Sellner,
C. Smorra,
K. Blaum,
Y. Matsuda,
W. Quint,
J. Walz,
S. Ulmer
Abstract:
We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap technique. Our analysis shows that preparation of (anti)protons at mK temperatures on timescales of tens of seconds is feasible. Successful implementation of the technique will have immediate and significant impact on h…
▽ More
We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap technique. Our analysis shows that preparation of (anti)protons at mK temperatures on timescales of tens of seconds is feasible. Successful implementation of the technique will have immediate and significant impact on high-precision comparisons of the fundamental properties of protons and antiprotons. This in turn will provide some of the most stringent tests of the fundamental symmetries of the Standard Model.
△ Less
Submitted 1 September, 2017;
originally announced September 2017.
-
High-precision measurement of the proton's atomic mass
Authors:
Fabian Heiße,
Florian Köhler-Langes,
Sascha Rau,
Jamin Hou,
Sven Junck,
Anke Kracke,
Andreas Mooser,
Wolfgang Quint,
Stefan Ulmer,
Günter Werth,
Klaus Blaum,
Sven Sturm
Abstract:
We report on the precise measurement of the atomic mass of a single proton with a purpose-built Penning-trap system. With a precision of 32 parts-per-trillion our result not only improves on the current CODATA literature value by a factor of three, but also disagrees with it at a level of about 3 standard deviations.
We report on the precise measurement of the atomic mass of a single proton with a purpose-built Penning-trap system. With a precision of 32 parts-per-trillion our result not only improves on the current CODATA literature value by a factor of three, but also disagrees with it at a level of about 3 standard deviations.
△ Less
Submitted 21 June, 2017;
originally announced June 2017.
-
Observation of individual spin quantum transitions of a single antiproton
Authors:
C. Smorra,
A. Mooser,
M. Besirli,
M. Bohman,
M. J. Borchert,
J. Harrington,
T. Higuchi,
H. Nagahama,
G. L. Schneider,
S. Sellner,
T. Tanaka,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We report on the detection of individual spin quantum transitions of a single trapped antiproton in a Penning trap. The spin-state determination, which is based on the unambiguous detection of axial frequency shifts in presence of a strong magnetic bottle, reaches a fidelity of 92.1$\%$. Spin-state initialization with $>99.9\%$ fidelity and an average initialization time of 24 min are demonstrated…
▽ More
We report on the detection of individual spin quantum transitions of a single trapped antiproton in a Penning trap. The spin-state determination, which is based on the unambiguous detection of axial frequency shifts in presence of a strong magnetic bottle, reaches a fidelity of 92.1$\%$. Spin-state initialization with $>99.9\%$ fidelity and an average initialization time of 24 min are demonstrated. This is a major step towards an antiproton magnetic moment measurement with a relative uncertainty on the part-per-billion level.
△ Less
Submitted 21 March, 2017;
originally announced March 2017.
-
Highly-sensitive superconducting circuits at ~700 kHz with tunable quality factors for image-current detection of single trapped antiprotons
Authors:
H. Nagahama,
G. Schneider,
A. Mooser,
C. Smorra,
S. Sellner,
J. Harrington,
T. Higuchi,
M. Borchert,
T. Tanaka,
M. Besirli,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550$\sim$800$\,$kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500$\,$000, which corresponds to a factor…
▽ More
We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550$\sim$800$\,$kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500$\,$000, which corresponds to a factor of 10 improvement compared to our previously used solenoidal designs. Connected to ultra-low noise amplifiers and the trap system, signal-to-noise-ratios of 30$\,$dB at quality factors of > 20$\,$000 are achieved. In addition, we have developed a superconducting switch which allows continuous tuning of the detector's quality factor, and to sensitively tune the particle-detector interaction. This allowed us to improve frequency resolution at constant averaging time, which is crucial for single antiproton spin-transition spectroscopy experiments, as well as improved measurements of the proton-to-antiproton charge-to-mass ratio.
△ Less
Submitted 26 December, 2016;
originally announced December 2016.
-
BASE - The Baryon Antibaryon Symmetry Experiment
Authors:
C. Smorra,
K. Blaum,
L. Bojtar,
M. Borchert,
K. A. Franke,
T. Higuchi,
N. Leefer,
H. Nagahama,
Y. Matsuda,
A. Mooser,
M. Niemann,
C. Ospelkaus,
W. Quint,
G. Schneider,
S. Sellner,
T. Tanaka,
S. Van Gorp,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing the magnetic moments of the proton and the antiproton with high precision. Using single particles in a Penning trap, the proton/antiproton $g$-factors, i.e. the magnetic moment in units of the nuclear magneton, are determined by measuring…
▽ More
The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing the magnetic moments of the proton and the antiproton with high precision. Using single particles in a Penning trap, the proton/antiproton $g$-factors, i.e. the magnetic moment in units of the nuclear magneton, are determined by measuring the respective ratio of the spin-precession frequency to the cyclotron frequency. The spin precession frequency is measured by non-destructive detection of spin quantum transitions using the continuous Stern-Gerlach effect, and the cyclotron frequency is determined from the particle's motional eigenfrequencies in the Penning trap using the invariance theorem. By application of the double Penning-trap method we expect that in our measurements a fractional precision of $δg/g$ 10$^{-9}$ can be achieved. The successful application of this method to the antiproton will represent a factor 1000 improvement in the fractional precision of its magnetic moment. The BASE collaboration has constructed and commissioned a new experiment at the Antiproton Decelerator (AD) of CERN. This article describes and summarizes the physical and technical aspects of this new experiment.
△ Less
Submitted 29 April, 2016;
originally announced April 2016.
-
A reservoir trap for antiprotons
Authors:
Christian Smorra,
Andreas Mooser,
Kurt Franke,
Hiroki Nagahama,
Georg Schneider,
Takashi Higuchi,
Simon Van Gorp,
Klaus Blaum,
Yasuyuki Matsuda,
Wolfgang Quint,
Jochen Walz,
Yasunori Yamazaki,
Stefan Ulmer
Abstract:
We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and a…
▽ More
We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic particles.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Observation of Rayleigh-Taylor-Instability Evolution in a Plasma with Magnetic and Viscous Effects
Authors:
Colin S. Adams,
Auna L. Moser,
Scott C. Hsu
Abstract:
We present time-resolved observations of Rayleigh--Taylor-instability (RTI) evolution at the interface between an unmagnetized plasma jet colliding with a stagnated, magnetized plasma. The observed instability growth time ($\sim 10$~$μ$s) is consistent with the estimated linear RTI growth rate calculated using experimentally inferred values of density ($\sim 10^{14}$~cm$^{-3}$) and deceleration (…
▽ More
We present time-resolved observations of Rayleigh--Taylor-instability (RTI) evolution at the interface between an unmagnetized plasma jet colliding with a stagnated, magnetized plasma. The observed instability growth time ($\sim 10$~$μ$s) is consistent with the estimated linear RTI growth rate calculated using experimentally inferred values of density ($\sim 10^{14}$~cm$^{-3}$) and deceleration ($\sim 10^9$~m/s$^2$). The observed mode wavelength ($\gtrsim 1$~cm) nearly doubles within a linear growth time. Theoretical estimates of magnetic and viscous stabilization and idealized magnetohydrodynamic simulations including a physical viscosity model both suggest that the observed instability evolution is subject to magnetic and/or viscous effects.
△ Less
Submitted 26 October, 2015; v1 submitted 18 December, 2014;
originally announced December 2014.
-
Experimental characterization of a transition from collisionless to collisional interaction between head-on-merging supersonic plasma jets
Authors:
Auna L. Moser,
Scott C. Hsu
Abstract:
We present results from experiments on the head-on merging of two supersonic plasma jets in an initially collisionless regime for the counter-streaming ions. The plasma jets are of either an argon/impurity or hydrogen/impurity mixture and are produced by pulsed-power-driven railguns. Based on time- and space-resolved fast-imaging, multi-chord interferometry, and survey-spectroscopy measurements of…
▽ More
We present results from experiments on the head-on merging of two supersonic plasma jets in an initially collisionless regime for the counter-streaming ions. The plasma jets are of either an argon/impurity or hydrogen/impurity mixture and are produced by pulsed-power-driven railguns. Based on time- and space-resolved fast-imaging, multi-chord interferometry, and survey-spectroscopy measurements of the overlap** region between the merging jets, we observe that the jets initially interpenetrate, consistent with calculated inter-jet ion collision lengths, which are long. As the jets interpenetrate, a rising mean-charge state causes a rapid decrease in the inter-jet ion collision length. Finally, the interaction becomes collisional and the jets stagnate, eventually producing structures consistent with collisional shocks. These experimental observations can aid in the validation of plasma collisionality and ionization models for plasmas with complex equations of state.
△ Less
Submitted 11 May, 2015; v1 submitted 3 December, 2014;
originally announced December 2014.
-
Laboratory plasma physics experiments using merging supersonic plasma jets
Authors:
S. C. Hsu,
A. L. Moser,
E. C. Merritt,
C. S. Adams,
J. P. Dunn,
S. Brockington,
A. Case,
M. Gilmore,
A. G. Lynn,
S. J. Messer,
F. D. Witherspoon
Abstract:
We describe a laboratory plasma physics experiment at Los Alamos National Laboratory that uses two merging supersonic plasma jets formed and launched by pulsed-power-driven rail guns. The jets can be formed using any atomic species or mixture available in a compressed-gas bottle and have the following nominal initial parameters at the railgun nozzle exit: $n_e\approx n_i \sim 10^{16}$ cm$^{-3}$,…
▽ More
We describe a laboratory plasma physics experiment at Los Alamos National Laboratory that uses two merging supersonic plasma jets formed and launched by pulsed-power-driven rail guns. The jets can be formed using any atomic species or mixture available in a compressed-gas bottle and have the following nominal initial parameters at the railgun nozzle exit: $n_e\approx n_i \sim 10^{16}$ cm$^{-3}$, $T_e \approx T_i \approx 1.4$ eV, $V_{\rm jet}\approx 30$-100 km/s, mean charge $\bar{Z}\approx 1$, sonic Mach number $M_s\equiv V_{\rm jet}/C_s>10$, jet diameter $=5$ cm, and jet length $\approx 20$ cm. Experiments to date have focused on the study of merging-jet dynamics and the shocks that form as a result of the interaction, in both collisional and collisionless regimes with respect to the inter-jet classical ion mean free path, and with and without an applied magnetic field. However, many other studies are also possible, as discussed in this paper.
△ Less
Submitted 21 April, 2015; v1 submitted 1 August, 2014;
originally announced August 2014.
-
Direct high-precision measurement of the magnetic moment of the proton
Authors:
A. Mooser,
S. Ulmer,
K. Blaum,
K. Franke,
H. Kracke,
C. Leiteritz,
W. Quint,
C. C. Rodegheri,
C. Smorra,
J. Walz
Abstract:
The spin-magnetic moment of the proton $μ_p$ is a fundamental property of this particle. So far $μ_p$ has only been measured indirectly, analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here, we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio…
▽ More
The spin-magnetic moment of the proton $μ_p$ is a fundamental property of this particle. So far $μ_p$ has only been measured indirectly, analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here, we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin-transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in units of the nuclear magneton $μ_p=2.792847350(9)μ_N$. This measurement outperforms previous Penning trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty year old indirect measurement, in which significant theoretical bound state corrections were required to obtain $μ_p$, by a factor of 3. By application of this method to the antiproton magnetic moment $μ_{\bar{p}}$ the fractional precision of the recently reported value can be improved by a factor of at least 1000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.
△ Less
Submitted 18 June, 2014;
originally announced June 2014.
-
Observation of ionization-mediated transition from collisionless interpenetration to collisional stagnation during merging of two supersonic plasmas
Authors:
Auna L. Moser,
Scott C. Hsu
Abstract:
We present space- and time-resolved experimental data of head-on-merging, supersonic plasma jets (of an argon/impurity mixture) in an initially collisionless regime for counter-streaming ions. The merging begins with collisionless interpenetration followed by a transition to collisional stagnation. The transition occurs due to an experimentally inferred rising mean-ionization level, which rapidly…
▽ More
We present space- and time-resolved experimental data of head-on-merging, supersonic plasma jets (of an argon/impurity mixture) in an initially collisionless regime for counter-streaming ions. The merging begins with collisionless interpenetration followed by a transition to collisional stagnation. The transition occurs due to an experimentally inferred rising mean-ionization level, which rapidly reduces the counter-streaming ion-ion mean free path. The measurements demonstrate a specific mechanism by which a collisionless interaction transitions to a collisional one and constrain collisionality and ionization models for plasmas with complex equation of state.
△ Less
Submitted 30 April, 2015; v1 submitted 9 May, 2014;
originally announced May 2014.
-
The magnetic moments of the proton and the antiproton
Authors:
S. Ulmer,
A. Mooser,
K. Blaum,
S. Braeuninger,
K. Franke,
H. Kracke,
C. Leiteritz,
Y. Matsuda,
H. Nagahama,
C. Ospelkaus,
C. C. Rodegheri,
W. Quint,
G. Schneider,
C. Smorra,
S. Van Gorp,
J. Walz,
Y. Yamazaki
Abstract:
Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin state. Based on this success the proton magnetic moment $μ_p$ was measured with ppm precision in a Penning trap with a superimposed magnetic field inhomogeneity. An improvement by an additional factor of 1000 in precision i…
▽ More
Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin state. Based on this success the proton magnetic moment $μ_p$ was measured with ppm precision in a Penning trap with a superimposed magnetic field inhomogeneity. An improvement by an additional factor of 1000 in precision is possible by application of the so-called double Penning trap technique. In a recent paper we reported the first demonstration of this method with a single trapped proton, which is a major step towards the first direct high-precision measurement of $μ_p$. The techniques required for the proton can be directly applied to measure the antiproton magnetic moment $μ_{\bar{p}}$. An improvement in precision of $μ_{\bar{p}}$ by more than three orders of magnitude becomes possible, which will provide one of the most sensitive tests of CPT invariance. To achieve this research goal we are currently setting up the Baryon Antibaryon Symmetry Experiment (BASE) at the antiproton decelerator (AD) of CERN.
△ Less
Submitted 7 February, 2014;
originally announced February 2014.
-
Towards a high-precision measurement of the antiproton magnetic moment
Authors:
C. Smorra,
K. Blaum,
K. Franke,
Y. Matsuda,
A. Mooser,
H. Nagahama,
C. Ospelkaus,
W. Quint,
G. Schneider,
S. Van Gorp,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success, which has been achieved with our apparatus at the University of Mainz, we demonstrated recently the first application of the so called double Penning-trap method with a single proton. This is a major step towards a measu…
▽ More
The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success, which has been achieved with our apparatus at the University of Mainz, we demonstrated recently the first application of the so called double Penning-trap method with a single proton. This is a major step towards a measurement of the proton magnetic moment with ppb precision. To apply this method to a single trapped antiproton our collaboration is currently setting up a companion experiment at the antiproton decelerator of CERN. This effort is recognized as the Baryon Antibaryon Symmetry Experiment (BASE). A comparison of both magnetic moment values will provide a stringent test of CPT invariance with baryons.
△ Less
Submitted 9 January, 2014;
originally announced January 2014.
-
Experimental evidence for collisional shock formation via two obliquely merging supersonic plasma jets
Authors:
Elizabeth C. Merritt,
Auna L. Moser,
Scott C. Hsu,
Colin S. Adams,
John P. Dunn,
A. Miguel Holgado,
Mark A. Gilmore
Abstract:
We report spatially resolved measurements of the oblique merging of two supersonic laboratory plasma jets. The jets are formed and launched by pulsed-power-driven railguns using injected argon, and have electron density $\sim 10^{14}$ cm$^{-3}$, electron temperature $\approx 1.4$ eV, ionization fraction near unity, and velocity $\approx 40$ km/s just prior to merging. The jet merging produces a fe…
▽ More
We report spatially resolved measurements of the oblique merging of two supersonic laboratory plasma jets. The jets are formed and launched by pulsed-power-driven railguns using injected argon, and have electron density $\sim 10^{14}$ cm$^{-3}$, electron temperature $\approx 1.4$ eV, ionization fraction near unity, and velocity $\approx 40$ km/s just prior to merging. The jet merging produces a few-cm-thick stagnation layer, as observed in both fast-framing camera images and multi-chord interferometer data, consistent with collisional shock formation [E. C. Merritt et al., Phys. Rev. Lett. {\bf 111}, 085003 (2013)].
△ Less
Submitted 31 March, 2014; v1 submitted 25 November, 2013;
originally announced November 2013.
-
Demonstration of the Double Penning Trap Technique with a Single Proton
Authors:
A. Mooser,
S. Braeuninger,
K. Franke,
H. Kracke,
C. Leiteritz,
C. C. Rodegheri,
H. Nagahama,
G. Schneider,
C. Smorra,
K. Blaum,
Y. Matsuda,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
Spin flips of a single proton were driven in a Penning trap with a homogeneous magnetic field. For the spin-state analysis the proton was transported into a second Penning trap with a superimposed magnetic bottle, and the continuous Stern-Gerlach effect was applied. This first demonstration of the double Penning trap technique with a single proton suggests that the antiproton magnetic moment measu…
▽ More
Spin flips of a single proton were driven in a Penning trap with a homogeneous magnetic field. For the spin-state analysis the proton was transported into a second Penning trap with a superimposed magnetic bottle, and the continuous Stern-Gerlach effect was applied. This first demonstration of the double Penning trap technique with a single proton suggests that the antiproton magnetic moment measurement can potentially be improved by three orders of magnitude or more.
△ Less
Submitted 6 May, 2013;
originally announced May 2013.
-
Experimental characterization of the stagnation layer between two obliquely merging supersonic plasma jets
Authors:
Elizabeth C. Merritt,
Auna L. Moser,
Scott C. Hsu,
John Loverich,
Mark Gilmore
Abstract:
We present spatially resolved measurements characterizing the stagnation layer between two obliquely merging supersonic plasma jets. Intra-jet collisionality is very high ($λ_{ii} \ll 1$mm), but the inter-jet ion-ion mean free paths are on the same order as the stagnation layer thickness (a few cm). Fast-framing camera images show a double-peaked emission profile transverse to the stagnation layer…
▽ More
We present spatially resolved measurements characterizing the stagnation layer between two obliquely merging supersonic plasma jets. Intra-jet collisionality is very high ($λ_{ii} \ll 1$mm), but the inter-jet ion-ion mean free paths are on the same order as the stagnation layer thickness (a few cm). Fast-framing camera images show a double-peaked emission profile transverse to the stagnation layer, with the central emission dip consistent with a density dip observed in the interferometer data. We demonstrate that our observations are consistent with collisional oblique shocks.
△ Less
Submitted 7 June, 2013; v1 submitted 23 March, 2013;
originally announced March 2013.
-
Resolution of Single Spin-Flips of a Single Proton
Authors:
A. Mooser,
H. Kracke,
K. Blaum,
S. A. Braeuninger,
K. Franke,
C. Leiteritz,
W. Quint,
C. C. Rodegheri,
S. Ulmer,
J. Walz
Abstract:
The spin magnetic moment of a single proton in a cryogenic Penning trap was coupled to the particle's axial motion with a superimposed magnetic bottle. Jumps in the oscillation frequency indicate spin-flips and were identified using a Bayesian analysis.
The spin magnetic moment of a single proton in a cryogenic Penning trap was coupled to the particle's axial motion with a superimposed magnetic bottle. Jumps in the oscillation frequency indicate spin-flips and were identified using a Bayesian analysis.
△ Less
Submitted 22 March, 2013; v1 submitted 6 March, 2013;
originally announced March 2013.
-
Experimental characterization of railgun-driven supersonic plasma jets motivated by high energy density physics applications
Authors:
S. C. Hsu,
E. C. Merritt,
A. L. Moser,
T. J. Awe,
S. J. E. Brockington,
J. S. Davis,
C. S. Adams,
A. Case,
J. T. Cassibry,
J. P. Dunn,
M. A. Gilmore,
A. G. Lynn,
S. J. Messer,
F. D. Witherspoon
Abstract:
We report experimental results on the parameters, structure, and evolution of high-Mach-number (M) argon plasma jets formed and launched by a pulsed-power-driven railgun. The nominal initial average jet parameters in the data set analyzed are density \approx 2 x 10^(16) cm^(-3), electron temperature \approx 1.4 eV, velocity \approx 30 km/s, M \approx 14, ionization fraction \approx 0.96, diameter…
▽ More
We report experimental results on the parameters, structure, and evolution of high-Mach-number (M) argon plasma jets formed and launched by a pulsed-power-driven railgun. The nominal initial average jet parameters in the data set analyzed are density \approx 2 x 10^(16) cm^(-3), electron temperature \approx 1.4 eV, velocity \approx 30 km/s, M \approx 14, ionization fraction \approx 0.96, diameter \approx 5 cm, and length \approx 20 cm. These values approach the range needed by the Plasma Liner Experiment (PLX), which is designed to use merging plasma jets to form imploding spherical plasma liners that can reach peak pressures of 0.1-1 Mbar at stagnation. As these jets propagate a distance of approximately 40 cm, the average density drops by one order of magnitude, which is at the very low end of the 8-160 times drop predicted by ideal hydrodynamic theory of a constant-M jet.
△ Less
Submitted 11 December, 2012; v1 submitted 21 October, 2012;
originally announced October 2012.
-
Observation of Spin Flips with a Single Trapped Proton
Authors:
S. Ulmer,
C. C. Rodegheri,
K. Blaum,
H. Kracke,
A. Mooser,
W. Quint,
J. Walz
Abstract:
Radio-frequency induced spin transitions of one individual proton are observed for the first time. The spin quantum jumps are detected via the continuous Stern-Gerlach effect, which is used in an experiment with a single proton stored in a cryogenic Penning trap. This is an important milestone towards a direct high-precision measurement of the magnetic moment of the proton and a new test of the ma…
▽ More
Radio-frequency induced spin transitions of one individual proton are observed for the first time. The spin quantum jumps are detected via the continuous Stern-Gerlach effect, which is used in an experiment with a single proton stored in a cryogenic Penning trap. This is an important milestone towards a direct high-precision measurement of the magnetic moment of the proton and a new test of the matter-antimatter symmetry in the baryon sector.
△ Less
Submitted 3 May, 2011; v1 submitted 6 April, 2011;
originally announced April 2011.