-
Hydrogen Trap** and Embrittlement in Metals -- A Review
Authors:
Y. -S. Chen,
C. Huang,
P. -Y. Liu,
H. -W. Yen,
R. Niu,
P. Burr,
K. L. Moore,
E. Martínez-Pañeda,
A. Atrens,
J. M. Cairney
Abstract:
Hydrogen embrittlement in metals (HE) is a serious challenge for the use of high strength materials in engineering practice and a major barrier to the use of hydrogen for global decarbonization. Here we describe the factors and variables that determine HE susceptibility and provide an overview of the latest understanding of HE mechanisms. We discuss hydrogen uptake and how it can be managed. We su…
▽ More
Hydrogen embrittlement in metals (HE) is a serious challenge for the use of high strength materials in engineering practice and a major barrier to the use of hydrogen for global decarbonization. Here we describe the factors and variables that determine HE susceptibility and provide an overview of the latest understanding of HE mechanisms. We discuss hydrogen uptake and how it can be managed. We summarize hydrogen trap** and the techniques used for its characterization. We also review literature that argues that hydrogen trap** can be used to decrease HE susceptibility. We discuss the future research that is required to advance the understanding of HE and hydrogen trap** and to develop HE-resistant alloys.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
Highly ${ }^{28} \mathrm{Si}$ Enriched Silicon by Localised Focused Ion Beam Implantation
Authors:
Ravi Acharya,
Maddison Coke,
Mason Adshead,
Kexue Li,
Barat Achinuq,
Rongsheng Cai,
A. Baset Gholizadeh,
Janet Jacobs,
Jessica L. Boland,
Sarah J. Haigh,
Katie L. Moore,
David N. Jamieson,
Richard J. Curry
Abstract:
Solid-state spin qubits within silicon crystals at mK temperatures show great promise in the realisation of a fully scalable quantum computation platform. Qubit coherence times are limited in natural silicon owing to coupling to the isotope ${ }^{29} \mathrm{Si}$ which has a non-zero nuclear spin. This work presents a method for the depletion of ${ }^{29} \mathrm{Si}$ in localised volumes of natur…
▽ More
Solid-state spin qubits within silicon crystals at mK temperatures show great promise in the realisation of a fully scalable quantum computation platform. Qubit coherence times are limited in natural silicon owing to coupling to the isotope ${ }^{29} \mathrm{Si}$ which has a non-zero nuclear spin. This work presents a method for the depletion of ${ }^{29} \mathrm{Si}$ in localised volumes of natural silicon wafers by irradiation using a 45 keV ${ }^{28} \mathrm{Si}$ focused ion beam with fluences above $1 \times 10^{19} \, \mathrm{ions} \, \mathrm{cm}^{-2}$. Nanoscale secondary ion mass spectrometry analysis of the irradiated volumes shows unprecedented quality enriched silicon that reaches a minimal residual ${ }^{29} \mathrm{Si}$ value of 2.3 $\pm$ 0.7 ppm and with residual C and O comparable to the background concentration in the unimplanted wafer. Transmission electron microscopy lattice images confirm the solid phase epitaxial re-crystallization of the as-implanted amorphous enriched volume extending over 200 nm in depth upon annealing. The ease of fabrication, requiring only commercially available natural silicon wafers and ion sources, opens the possibility for co-integration of qubits in localised highly enriched volumes with control circuitry in the surrounding natural silicon for large-scale devices.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
Forecasting per-patient dosimetric benefit from daily online adaptive radiotherapy for cervical cancer
Authors:
Rupesh Ghimire,
Kevin L. Moore,
Daniela Branco,
Dominique L. Rash,
Jyoti Mayadev,
Xenia Ray
Abstract:
Adaptive Radiotherapy (ART) is an emerging technique for treating cancer patients which facilitates higher delivery accuracy and has the potential to reduce toxicity. However, ART is also resource-intensive, requiring extra human and machine time compared to standard treatment methods. In this analysis, we sought to predict the subset of node-negative cervical cancer patients who benefit the most…
▽ More
Adaptive Radiotherapy (ART) is an emerging technique for treating cancer patients which facilitates higher delivery accuracy and has the potential to reduce toxicity. However, ART is also resource-intensive, requiring extra human and machine time compared to standard treatment methods. In this analysis, we sought to predict the subset of node-negative cervical cancer patients who benefit the most from ART. CT images, initial plan data, and on-treatment Cone-Beam CT (CBCT) images for 20 retrospective cervical cancer patients were used to simulate doses from daily non-adaptive and adaptive techniques. We evaluated the correlation (R$^2$) between dose and volume metrics from initial treatment plans and the dosimetric benefits to the Bowel V$_{40Gy}$, Bowel V$_{45Gy}$, Bladder D$_{mean}$, and Rectum D$_{mean}$ from adaptive radiotherapy using reduced 3mm or 5mm CTV-to-PTV margins. The LASSO technique was used to identify the most predictive metrics for Bowel V$_{40Gy}$. The three highest performing metrics were used to build multivariate models with leave-one-out validation for Bowel V$_{40Gy}$. Patients with higher initial bowel doses were correlated with the largest decreases in Bowel V$_{40Gy}$ from daily adaptation (linear best fit R$^2$=0.77 for a 3mm PTV margin and R$^2$=0.8 for a 5mm PTV margin). Other metrics had intermediate or no correlation. Selected covariates for the multivariate model were differences in the initial Bowel V$_{40Gy}$. and Bladder D$_{mean}$ using standard versus reduced margins and the initial bladder volume. Leave-one-out validation had an R$^2$ of 0.66 between the predicted and true adaptive Bowel V$_{40Gy}$ benefits for both margins. This work could be used to prospectively triage cervical cancer patients, and presents a critical foundation for predicting benefits from daily adaptation that can be extended to other patient cohorts.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
OpenKBP-Opt: An international and reproducible evaluation of 76 knowledge-based planning pipelines
Authors:
Aaron Babier,
Rafid Mahmood,
Binghao Zhang,
Victor G. L. Alves,
Ana Maria Barragán-Montero,
Joel Beaudry,
Carlos E. Cardenas,
Yankui Chang,
Zijie Chen,
Jaehee Chun,
Kelly Diaz,
Harold David Eraso,
Erik Faustmann,
Sibaji Gaj,
Skylar Gay,
Mary Gronberg,
Bingqi Guo,
Junjun He,
Gerd Heilemann,
Sanchit Hira,
Yuliang Huang,
Fuxin Ji,
Dashan Jiang,
Jean Carlo Jimenez Giraldo,
Hoyeon Lee
, et al. (34 additional authors not shown)
Abstract:
We establish an open framework for develo** plan optimization models for knowledge-based planning (KBP) in radiotherapy. Our framework includes reference plans for 100 patients with head-and-neck cancer and high-quality dose predictions from 19 KBP models that were developed by different research groups during the OpenKBP Grand Challenge. The dose predictions were input to four optimization mode…
▽ More
We establish an open framework for develo** plan optimization models for knowledge-based planning (KBP) in radiotherapy. Our framework includes reference plans for 100 patients with head-and-neck cancer and high-quality dose predictions from 19 KBP models that were developed by different research groups during the OpenKBP Grand Challenge. The dose predictions were input to four optimization models to form 76 unique KBP pipelines that generated 7600 plans. The predictions and plans were compared to the reference plans via: dose score, which is the average mean absolute voxel-by-voxel difference in dose a model achieved; the deviation in dose-volume histogram (DVH) criterion; and the frequency of clinical planning criteria satisfaction. We also performed a theoretical investigation to justify our dose mimicking models. The range in rank order correlation of the dose score between predictions and their KBP pipelines was 0.50 to 0.62, which indicates that the quality of the predictions is generally positively correlated with the quality of the plans. Additionally, compared to the input predictions, the KBP-generated plans performed significantly better (P<0.05; one-sided Wilcoxon test) on 18 of 23 DVH criteria. Similarly, each optimization model generated plans that satisfied a higher percentage of criteria than the reference plans. Lastly, our theoretical investigation demonstrated that the dose mimicking models generated plans that are also optimal for a conventional planning model. This was the largest international effort to date for evaluating the combination of KBP prediction and optimization models. In the interest of reproducibility, our data and code is freely available at https://github.com/ababier/open-kbp-opt.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
Application of high-spatial-resolution secondary ion mass spectrometry for nanoscale chemical map** of lithium in an Al-Li alloy
Authors:
Xu Xu,
Chengge Jiao,
Kexue Li,
Min Hao,
Katie. L. Moore,
Timothy. L. Burnett,
Xiaorong Zhou
Abstract:
High-spatial-resolution secondary ion mass spectrometry offers a method for map** lithium at nanoscale lateral resolution. Practical implementation of this technique offers significant potential for revealing the distribution of Li in many materials with exceptional lateral resolution and elemental sensitivity. Here, two state-of-the-art methods are demonstrated on an aluminium-lithium alloy to…
▽ More
High-spatial-resolution secondary ion mass spectrometry offers a method for map** lithium at nanoscale lateral resolution. Practical implementation of this technique offers significant potential for revealing the distribution of Li in many materials with exceptional lateral resolution and elemental sensitivity. Here, two state-of-the-art methods are demonstrated on an aluminium-lithium alloy to visualise nanoscale Li-rich phases by map** the 7Li+ secondary ion. NanoSIMS 50L analysis with a radio frequency O- plasma ion source enabled visualisation of needle-shaped T1 (Al2CuLi) phases as small as 75 nm in width. A compact time-of-flight secondary ion mass spectrometry detector added to a focused ion beam scanning electron microscope facilitated map** of the T1 phases down to 45 nm in width using a Ga+ ion beam. Correlation with high resolution electron microscopy confirms the identification of T1 precipitates, their sizes and distribution observed during SIMS map**.
△ Less
Submitted 25 February, 2021;
originally announced February 2021.
-
Knowledge-Based Three-Dimensional Dose Prediction for Tandem-And-Ovoid Brachytherapy
Authors:
Katherina G. Cortes,
Aaron Simon,
Karoline Kallis,
Jyoti Mayadev,
Sandra Meyers,
Kevin L. Moore
Abstract:
Purpose: To develop a knowledge-based voxel-wise dose prediction system using a convolution neural network for high-dose-rate brachytherapy cervical cancer treatments with a tandem-and-ovoid (T&O) applicator. Methods: A 3D U-NET was utilized to output dose predictions using organ-at-risk (OAR), high-risk clinical target volume (HRCTV), and possible source locations. A sample of previous T&O treatm…
▽ More
Purpose: To develop a knowledge-based voxel-wise dose prediction system using a convolution neural network for high-dose-rate brachytherapy cervical cancer treatments with a tandem-and-ovoid (T&O) applicator. Methods: A 3D U-NET was utilized to output dose predictions using organ-at-risk (OAR), high-risk clinical target volume (HRCTV), and possible source locations. A sample of previous T&O treatments comprising 397 cases (273 training:62 validation:62 test), HRCTV and OARs (bladder/rectum/sigmoid) was used. Structures and dose were interpolated to 1x1x2.5mm3 dose planes with two input channels (source positions, voxel identification) and one output channel for dose. We evaluated dose difference (ΔD)(xyz)=D_(actual)(x,y,z)-D_(predicted)(x,y,z) and dice similarity coefficients in all cohorts across the clinically-relevant dose range (20-130% of prescription), mean and standard deviation. We also examined discrete DVH metrics used for T&O plan quality assessment: HRCTV D_90%(dose to hottest 90% volume) and OAR D_2cc, with ΔD_x=D_(x,actual)-D_(x,predicted). Pearson correlation coefficient, standard deviation, and mean quantified model performance on the clinical metrics. Results: Voxel-wise dose difference accuracy for 20-130% dose range for training(test) ranges for mean (ΔD) and standard deviation for all voxels was [-0.3%+/-2.0% to +1.0%+/-12.0%] ([-0.1%+/-4% to +4.0%+/-26%]). Voxel-wise dice similarity coefficients for 20-130% dose ranged from [0.96, 0.91]([0.94, 0.87]). DVH metric prediction in the training (test) set were HRCTV(ΔD_90)=-0.19+/-0.55 Gy (-0.09+/-0.67 Gy), bladder(ΔD_2cc)=-0.06+/-0.54 Gy (-0.17+/-0.67 Gy), rectum(ΔD)_2cc=-0.03+/-0.36 Gy (-0.04+/-0.46 Gy), and sigmoid(ΔD_2cc)=-0.01+/-0.34 Gy (0.00+/-0.44 Gy). Conclusion: 3D knowledge-based dose predictions for T&O brachytherapy provide accurate voxel-level and DVH metric estimates.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
OpenKBP: The open-access knowledge-based planning grand challenge
Authors:
Aaron Babier,
Binghao Zhang,
Rafid Mahmood,
Kevin L. Moore,
Thomas G. Purdie,
Andrea L. McNiven,
Timothy C. Y. Chan
Abstract:
The purpose of this work is to advance fair and consistent comparisons of dose prediction methods for knowledge-based planning (KBP) in radiation therapy research. We hosted OpenKBP, a 2020 AAPM Grand Challenge, and challenged participants to develop the best method for predicting the dose of contoured CT images. The models were evaluated according to two separate scores: (1) dose score, which eva…
▽ More
The purpose of this work is to advance fair and consistent comparisons of dose prediction methods for knowledge-based planning (KBP) in radiation therapy research. We hosted OpenKBP, a 2020 AAPM Grand Challenge, and challenged participants to develop the best method for predicting the dose of contoured CT images. The models were evaluated according to two separate scores: (1) dose score, which evaluates the full 3D dose distributions, and (2) dose-volume histogram (DVH) score, which evaluates a set DVH metrics. Participants were given the data of 340 patients who were treated for head-and-neck cancer with radiation therapy. The data was partitioned into training (n=200), validation (n=40), and testing (n=100) datasets. All participants performed training and validation with the corresponding datasets during the validation phase of the Challenge, and we ranked the models in the testing phase based on out-of-sample performance. The Challenge attracted 195 participants from 28 countries, and 73 of those participants formed 44 teams in the validation phase, which received a total of 1750 submissions. The testing phase garnered submissions from 28 teams. On average, over the course of the validation phase, participants improved the dose and DVH scores of their models by a factor of 2.7 and 5.7, respectively. In the testing phase one model achieved significantly better dose and DVH score than the runner-up models. Lastly, many of the top performing teams reported using generalizable techniques (e.g., ensembles) to achieve higher performance than their competition. This is the first competition for knowledge-based planning research, and it helped launch the first platform for comparing KBP prediction methods fairly and consistently. The OpenKBP datasets are available publicly to help benchmark future KBP research, which has also democratized KBP research by making it accessible to everyone.
△ Less
Submitted 13 January, 2021; v1 submitted 28 November, 2020;
originally announced November 2020.
-
Dispersion management using betatron resonances in an ultracold-atom storage ring
Authors:
K. W. Murch,
K. L. Moore,
S. Gupta,
D. M. Stamper-Kurn
Abstract:
Specific velocities of particles circulating in a storage ring can lead to betatron resonances at which static perturbations of the particles' orbit yield large transverse (betatron) oscillations. We have observed betatron resonances in an ultracold-atom storage ring by direct observation of betatron motion. These resonances caused a near-elimination of the longitudinal dispersion of atomic beam…
▽ More
Specific velocities of particles circulating in a storage ring can lead to betatron resonances at which static perturbations of the particles' orbit yield large transverse (betatron) oscillations. We have observed betatron resonances in an ultracold-atom storage ring by direct observation of betatron motion. These resonances caused a near-elimination of the longitudinal dispersion of atomic beams propagating at resonant velocities, an effect which can improve the performance of atom interferometric devices. Both the resonant velocities and the strength of the resonances were varied by deliberate modifications to the storage ring.
△ Less
Submitted 31 August, 2005;
originally announced August 2005.
-
Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments
Authors:
Kevin L. Moore,
Thomas P. Purdy,
Kater W. Murch,
Sabrina Leslie,
Subhadeep Gupta,
Dan M. Stamper-Kurn
Abstract:
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed alkali metal dispenser in < 10^-10 torr ultra-high vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing "shroud" held at < 0 C, pum** rubidium atoms not directed into the MOT. This nearly eliminates background alkali atoms and reduces the detrimental rise in pr…
▽ More
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed alkali metal dispenser in < 10^-10 torr ultra-high vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing "shroud" held at < 0 C, pum** rubidium atoms not directed into the MOT. This nearly eliminates background alkali atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly-switched, two-temperature thermal beam, and was used to load a MOT with 3 x 10^8 atoms.
△ Less
Submitted 5 November, 2004; v1 submitted 1 September, 2004;
originally announced September 2004.