-
First characterization of a novel grain calorimeter: the GRAiNITA prototype
Authors:
Sergey Barsuk,
Oleg Bezshyyko,
Ianina Boyarintseva,
Andrey Boyarintsev,
Dominique Breton,
Hervé Chanal,
Alexander M. Dubovik,
Andrii Kotenko,
Giulia Hull,
Jacques Lefrançois,
Stéphane Monteil,
Marie-Hélène Schune,
Nazar Semkiv,
Irina Tupitsyna,
Mykhailo Yeresko
Abstract:
A novel type of calorimeter based on grains of inorganic scintillating crystal readout by wave length shifting fibers is proposed. The concept and main features as well as the prototype design are introduced and the first results obtained using cosmic rays are presented. The number of photo-electrons generated by cosmic rays muons in the prototype detector is estimated to be of the order of 10000…
▽ More
A novel type of calorimeter based on grains of inorganic scintillating crystal readout by wave length shifting fibers is proposed. The concept and main features as well as the prototype design are introduced and the first results obtained using cosmic rays are presented. The number of photo-electrons generated by cosmic rays muons in the prototype detector is estimated to be of the order of 10000 photo-electrons per GeV, validating the concept of this next-generation shashlik calorimeter.
△ Less
Submitted 12 February, 2024; v1 submitted 12 December, 2023;
originally announced December 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
SoLid: A short baseline reactor neutrino experiment
Authors:
SoLid Collaboration,
Y. Abreu,
Y. Amhis,
L. Arnold,
G. Barber,
W. Beaumont,
S. Binet,
I. Bolognino,
M. Bongrand,
J. Borg,
D. Boursette,
V. Buridon,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupe,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
T. Durkin,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves
, et al. (37 additional authors not shown)
Abstract:
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino en…
▽ More
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration.
△ Less
Submitted 15 December, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
FCC-ee: Your Questions Answered
Authors:
Alain Blondel,
Patrick Janot,
Niloufar Alipour Tehrani,
Patrizia Azzi,
Paolo Azzurri,
Nicola Bacchetta,
Michael Benedikt,
Freya Blekman,
Manuela Boscolo,
Mogens Dam,
Stefania De Curtis,
David d'Enterria,
John Ellis,
Gerardo Ganis,
Janusz Gluza,
Clément Helsens,
Staszek Jadach,
Mike Koratzinos,
Markus Klute,
Christos Leonidopoulos,
Elizabeth Locci,
Michelangelo Mangano,
Stéphane Monteil,
Katsunobu Oide,
Vitaly Okorokov
, et al. (7 additional authors not shown)
Abstract:
This document answers in simple terms many FAQs about FCC-ee, including comparisons with other colliders. It complements the FCC-ee CDR and the FCC Physics CDR by addressing many questions from non-experts and clarifying issues raised during the European Strategy symposium in Granada, with a view to informing discussions in the period between now and the final endorsement by the CERN Council in 20…
▽ More
This document answers in simple terms many FAQs about FCC-ee, including comparisons with other colliders. It complements the FCC-ee CDR and the FCC Physics CDR by addressing many questions from non-experts and clarifying issues raised during the European Strategy symposium in Granada, with a view to informing discussions in the period between now and the final endorsement by the CERN Council in 2020 of the European Strategy Group recommendations. This document will be regularly updated as more questions appear or new information becomes available.
△ Less
Submitted 6 June, 2019;
originally announced June 2019.
-
Design and performance of the LHCb trigger and full real-time reconstruction in Run 2 of the LHC
Authors:
R. Aaij,
S. Akar,
J. Albrecht,
M. Alexander,
A. Alfonso Albero,
S. Amerio,
L. Anderlini,
P. d'Argent,
A. Baranov,
W. Barter,
S. Benson,
D. Bobulska,
T. Boettcher,
S. Borghi,
E. E. Bowen,
L. Brarda,
C. Burr,
J. -P. Cachemiche,
M. Calvo Gomez,
M. Cattaneo,
H. Chanal,
M. Chapman,
M. Chebbi,
M. Chefdeville,
P. Ciambrone
, et al. (116 additional authors not shown)
Abstract:
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run…
▽ More
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run 2. We describe the design of the Run 2 trigger and real-time reconstruction, and present data-driven performance measurements for a representative sample of LHCb's physics programme.
△ Less
Submitted 25 June, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
Commissioning and Operation of the Readout System for the SoLid Neutrino Detector
Authors:
Y. Abreu,
Y. Amhis,
G. Ban,
W. Beaumont,
S. Binet,
M. Bongrand,
D. Boursette,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupé,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order…
▽ More
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80x80x250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.
△ Less
Submitted 31 August, 2019; v1 submitted 13 December, 2018;
originally announced December 2018.
-
Development of a Quality Assurance Process for the SoLid Experiment
Authors:
Y. Abreu,
Y. Amhis,
G. Ban,
W. Beaumont,
S. Binet,
M. Bongrand,
D. Boursette,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupé,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sh…
▽ More
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $\overlineν_e$ target for the inverse beta decay of ($\overlineν_e + p \rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $\mathcal{O}$(10)\% in the energy spectrum of reactor $\overlineν_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 \% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.
△ Less
Submitted 20 December, 2018; v1 submitted 13 November, 2018;
originally announced November 2018.
-
The HeRSCheL detector: high-rapidity shower counters for LHCb
Authors:
K. Carvalho Akiba,
F. Alessio,
N. Bondar,
W. Byczynski,
V. Coco,
P. Collins,
R. Dumps,
R. Dzhelyadin,
P. Gandini,
B. R. Gruberg Cazon,
R. Jacobsson,
D. Johnson,
J. Manthey,
J. Mauricio,
R. McNulty,
S. Monteil,
B. Rachwal,
M. Ravonel Salzgeber,
L. Roy,
H. Schindler,
S. Stevenson,
G. Wilkinson
Abstract:
The HeRSCheL detector consists of a set of scintillating counters, designed to increase the coverage of the LHCb experiment in the high-rapidity regions on either side of the main spectrometer. The new detector improves the capabilities of LHCb for studies of diffractive interactions, most notably Central Exclusive Production. In this paper the construction, installation, commissioning, and perfor…
▽ More
The HeRSCheL detector consists of a set of scintillating counters, designed to increase the coverage of the LHCb experiment in the high-rapidity regions on either side of the main spectrometer. The new detector improves the capabilities of LHCb for studies of diffractive interactions, most notably Central Exclusive Production. In this paper the construction, installation, commissioning, and performance of HeRSCheL are presented.
△ Less
Submitted 4 June, 2018; v1 submitted 12 January, 2018;
originally announced January 2018.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.