Skip to main content

Showing 1–50 of 51 results for author: Monroe, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.18597  [pdf, other

    physics.ins-det hep-ex

    Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data

    Authors: The DEAP Collaboration, P. Adhikari, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, D. J. Auty, M. Batygov, B. Beltran, C. E. Bina, W. Bonivento, M. G. Boulay, J. F. Bueno, B. Cai, M. Cárdenas-Montes, S. Choudhary, B. T. Cleveland, R. Crampton, S. Daugherty, P. DelGobbo, P. Di Stefano, G. Dolganov, L. Doria, F. A. Duncan, M. Dunford, E. Ellingwood , et al. (73 additional authors not shown)

    Abstract: The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace… ▽ More

    Submitted 12 June, 2024; originally announced June 2024.

    Comments: Submitted to Eur. Phys. J. C

  2. arXiv:2404.18492  [pdf, other

    physics.ins-det hep-ex

    A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

    Authors: DarkSide-20k Collaboration, :, F. Acerbi, P. Adhikari, P. Agnes, I. Ahmad, S. Albergo, I. F. Albuquerque, T. Alexander, A. K. Alton, P. Amaudruz, M. Angiolilli, E. Aprile, R. Ardito, M. Atzori Corona, D. J. Auty, M. Ave, I. C. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, A. Barrado Olmedo, P. Barrillon, G. Batignani, P. Bhowmick , et al. (290 additional authors not shown)

    Abstract: Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround… ▽ More

    Submitted 29 April, 2024; originally announced April 2024.

  3. arXiv:2402.00181  [pdf, other

    cond-mat.other physics.ins-det

    QUEST-DMC: Background Modelling and Resulting Heat Deposit for a Superfluid Helium-3 Bolometer

    Authors: S. Autti, A. Casey, N. Eng, N. Darvishi, P. Franchini, R. P. Haley, P. J. Heikkinen, A. Kemp, E. Leason, L. V. Levitin, J. Monroe, J. March-Russel, M. T. Noble, J. R. Prance, X. Rojas, T. Salmon, J. Saunders, R. Smith, M. D. Thompson, V. Tsepelin, S. M. West, L. Whitehead, K. Zhang, D. E. Zmeev

    Abstract: We report the results of radioactivity assays and heat leak calculations for a range of common cryogenic materials, considered for use in the QUEST-DMC superfluid 3He dark matter detector. The bolometer, instrumented with nanomechanical resonators, will be sensitive to energy deposits from dark matter interactions. Events from radioactive decays and cosmic rays constitute a significant background… ▽ More

    Submitted 19 May, 2024; v1 submitted 31 January, 2024; originally announced February 2024.

    Journal ref: Journal of Low Temperature Physics, Special Issue: Quantum Fluids and Solids (QFS2023)

  4. arXiv:2311.18647  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Long-term temporal stability of the DarkSide-50 dark matter detector

    Authors: The DarkSide-50 Collaboration, :, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. K. Alton, M. Ave, H. O. Back, G. Batignani, K. Biery, V. Bocci, W. M. Bonivento, B. Bottino, S. Bussino, M. Cadeddu, M. Cadoni, F. Calaprice, A. Caminata, M. D. Campos, N. Canci, M. Caravati, N. Cargioli, M. Cariello, M. Carlini, V. Cataudella , et al. (121 additional authors not shown)

    Abstract: The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time project… ▽ More

    Submitted 22 May, 2024; v1 submitted 30 November, 2023; originally announced November 2023.

    Comments: 13 pages, 5 figures

    Journal ref: JINST 19 P05057 (2024)

  5. arXiv:2311.02452  [pdf, other

    physics.ins-det cond-mat.mes-hall

    Long nanomechanical resonators with circular cross-section

    Authors: Samuli Autti, Andrew Casey, Marie Connelly, Neda Darvishi, Paolo Franchini, James Gorman, Richard P. Haley, Petri J. Heikkinen, Ashlea Kemp, Elizabeth Leason, John March-Russell, Jocelyn Monroe, Theo Noble, George R. Pickett, Jonathan R. Prance, Xavier Rojas, Tineke Salmon, John Saunders, Jack Slater, Robert Smith, Michael D. Thompson, Stephen M. West, Luke Whitehead, Vladislav V. Zavjalov, Kuang Zhang , et al. (1 additional authors not shown)

    Abstract: Fabrication of superconducting nanomechanical resonators for quantum research, detectors and devices traditionally relies on a lithographic process, resulting in oscillators with sharp edges and a suspended length limited to a few 100 micrometres. We report a low-investment top-down approach to fabricating NbTi nanowire resonators with suspended lengths up to several millimetres and diameters down… ▽ More

    Submitted 4 November, 2023; originally announced November 2023.

    Comments: 19 pages, 4 figures

  6. arXiv:2307.15454  [pdf, other

    physics.ins-det

    Directionality of nuclear recoils in a liquid argon time projection chamber

    Authors: The DarkSide-20k Collaboration, :, P. Agnes, I. Ahmad, S. Albergo, I. F. M. Albuquerque, T. Alexander, A. K. Alton, P. Amaudruz, M. Atzori Corona, M. Ave, I. Ch. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, A. Barrado-Olmedo, P. Barrillon, A. Basco, G. Batignani, V. Bocci, W. M. Bonivento, B. Bottino, M. G. Boulay, J. Busto, M. Cadeddu , et al. (243 additional authors not shown)

    Abstract: The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scint… ▽ More

    Submitted 28 July, 2023; originally announced July 2023.

    Comments: 20 pages, 10 figures, submitted to Eur. Phys. J. C

    Journal ref: Eur. Phys. J. C 84:24 (2024)

  7. arXiv:2305.08822  [pdf, other

    physics.ins-det hep-ex

    First operation of an ALICE OROC operated in high pressure Ar-CO$_{2}$ and Ar-CH$_{4}$

    Authors: A. Ritchie-Yates, A. Deisting, G. Barker, S. Boyd, D. Brailsford, Z. Chen-Wishart, L. Cremonesi, P. Dunne, J. Eeles, P. Hamilton, A. C. Kaboth, N. Khan, A. Klustová, J. Monroe, J. Nowak, P. Singh, A. V. Waldron, J. Walding, L. Warsame, M. O. Wascko, I. Xiotidis

    Abstract: New neutrino-nucleus interaction cross-section measurements are required to improve nuclear models sufficiently for future long-baseline neutrino experiments to meet their sensitivity goals. A time projection chamber (TPC) filled with a high-pressure gas is a promising detector to characterise the neutrino sources planned for such experiments. A gas-filled TPC is ideal for measuring low-energy par… ▽ More

    Submitted 15 May, 2023; originally announced May 2023.

  8. arXiv:2302.14639  [pdf, other

    physics.ins-det hep-ex

    Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

    Authors: P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, J. Anstey, G. R. Araujo, D. J. Auty, M. Baldwin, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen , et al. (125 additional authors not shown)

    Abstract: The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi… ▽ More

    Submitted 10 October, 2023; v1 submitted 27 February, 2023; originally announced February 2023.

    Journal ref: Eur. Phys. J. C 83, 642 (2023)

  9. arXiv:2209.01177  [pdf, other

    physics.ins-det hep-ex

    Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

    Authors: P. Agnes, I. Ahmad, S. Albergo, I. F. M. Albuquerque, T. Alexander, A. K. Alton, P. Amaudruz, M. Atzori Corona, D. J. Auty, M. Ave, I. Ch. Avetisov, R. I. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, V. Barbarian, A. Barrado Olmedo, P. Barrillon, A. Basco, G. Batignani, E. Berzin, A. Bondar, W. M. Bonivento, E. Borisova, B. Bottino , et al. (274 additional authors not shown)

    Abstract: Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu… ▽ More

    Submitted 20 June, 2023; v1 submitted 2 September, 2022; originally announced September 2022.

    Journal ref: Phys. Rev. D 107, 112006 (2023)

  10. arXiv:2206.11441  [pdf, other

    physics.comp-ph nucl-ex physics.ins-det

    Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database

    Authors: Alexis Aguilar-Arevalo, Xavier Bertou, Carles Canet, Miguel A. Cruz-Pérez, Alexander Deisting, Adriana Dias, Juan Carlos D'Olivo, J. Francisco Favela-Pérez, Estela A. Garcés, Adiv González Muñoz, Jaime Octavio Guerra-Pulido, Javier Mancera-Alejandrez, Daniel José Marín-Lámbarri, Mauricio Martínez-Montero, Jocelyn Monroe, Sean Paling, Simon Peeters, Paul R. Scovell, Cenk Türkoglu, Eric Vázquez-Jáuregui, Joseph Walding

    Abstract: Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with… ▽ More

    Submitted 22 June, 2022; originally announced June 2022.

    Comments: 12 pages, 7 tables, 7 figures

    Journal ref: IEEE Transactions on Nuclear Science, 2022

  11. Volume reduction of water samples to increase sensitivity for radioassay of lead contamination

    Authors: A. Aguilar-Arevalo, C. Canet, M. A. Cruz-Pérez, A. Deisting, A. Dias, J. C. D'Olivo, F. Favela-Pérez, E. A. Garcés, A. González Muñoz, J. O. Guerra-Pulido, J. Mancera-Alejandrez, D. J. Marín-Lámbarri, M. Martinez Montero, J. R. Monroe, S. Paling, S. J. M. Peeters, P. R. Scovell, C. Türkoğlu, E. Vázquez-Jáuregui, J. Walding

    Abstract: The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity of low cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($^{210}Pb$), as a means to increase t… ▽ More

    Submitted 9 May, 2022; originally announced May 2022.

  12. arXiv:2201.03348  [pdf

    physics.ins-det

    PlomBOX -- development of a low-cost CMOS device for environmental monitoring

    Authors: A. Aguilar-Arevalo, E. Alba Posse, M. Alvarez, H. Arnaldi, H. Asorey, X. Bertou, A. Colque, A. Deisting, A. Dias, J. C. D'Olivo, F. Favela-Pérez, Y. Gándola, E. A. Garcés, J. Gasulla, M. Gómez Berisso, A. González Muñoz, J. O. Guerra-Pulido, S. Gutierrez, S. Jois, J. Lipovetzky, J. Lovera, M. B. Lovino, D. J. Marín-Lámbarri, L. Marpegan, D. Martín , et al. (14 additional authors not shown)

    Abstract: This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluor… ▽ More

    Submitted 10 January, 2022; originally announced January 2022.

  13. arXiv:2107.13753  [pdf, other

    physics.ins-det

    Characterisation of SiPM Photon Emission in the Dark

    Authors: J. B. McLaughlin, G. Gallina, F. Retière, A. De St. Croix, P. Giampa, M. Mahtab, P. Margetak, L. Martin, N. Massacret, J. Monroe, M. Patel, K. Raymond, J. Roiseux, L. Xie, G. Zhang

    Abstract: In this paper, we report on the photon emission of Silicon Photomultipliers (SiPMs) from avalanche pulses generated in dark condition, with the main objective of better understanding the associated systematics for next-generation, large area, SiPM-based physics experiments. A new apparatus for spectral and imaging analysis was developed at TRIUMF and used to measure the light emitted by the two Si… ▽ More

    Submitted 16 August, 2021; v1 submitted 29 July, 2021; originally announced July 2021.

    Comments: 14 pages, 8 figures

  14. arXiv:2103.12202  [pdf, other

    physics.ins-det astro-ph.IM

    Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

    Authors: The DEAP Collaboration, P. Adhikari, R. Ajaj, M. Alpízar-Venegas, P. -A. Amaudruz, D. J. Auty, M. Batygov, B. Beltran, H. Benmansour, C. E. Bina, J. Bonatt, W. Bonivento, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cadeddu, B. Cai, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, J. M. Corning , et al. (104 additional authors not shown)

    Abstract: The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar… ▽ More

    Submitted 6 April, 2021; v1 submitted 22 March, 2021; originally announced March 2021.

    Comments: 14 pages, 9 figures

    Journal ref: Eur. Phys. J. C 81, 823 (2021)

  15. arXiv:2102.06643  [pdf, other

    physics.ins-det hep-ex

    A High Pressure Time Projection Chamber with Optical Readout

    Authors: Alexander Deisting, Abigail Victoria Waldron, Edward Atkin, Gary Barker, Anastasia Basharina-Freshville, Christopher Betancourt, Steven Boyd, Dominic Brailsford, Zachary Chen-Wishart, Linda Cremonesi, Adriana Dias, Patrick Dunne, Jennifer Haigh, Philip Hamacher-Baumann, Sebastian Jones, Asher Kaboth, Alexander Korzenev, William Ma, Philippe Mermod, Maria Mironova, Jocelyn Monroe, Ryan Nichol, Toby Nonnenmacher, Jaroslaw Nowak, William Parker , et al. (11 additional authors not shown)

    Abstract: Measurements of proton-nucleus scattering and high resolution neutrino-nucleus interaction imaging are key to reduce neutrino oscillation systematic uncertainties in future experiments. A High Pressure Time Projection Chamber (HPTPC) prototype has been constructed and operated at Royal Holloway University of London and CERN as a first step in the development of a HPTPC capable of performing these… ▽ More

    Submitted 2 June, 2021; v1 submitted 12 February, 2021; originally announced February 2021.

    Comments: 40 pages, 24 figures

  16. arXiv:2101.08686  [pdf, other

    physics.ins-det astro-ph.IM

    Separating $^{39}$Ar from $^{40}$Ar by cryogenic distillation with Aria for dark matter searches

    Authors: DarkSide Collaboration, P. Agnes, S. Albergo, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, M. Arba, P. Arpaia, S. Arcelli, M. Ave, I. Ch. Avetissov, R. I. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, V. Barbarian, A. Barrado Olmedo, P. Barrillon, A. Basco, G. Batignani, A. Bondar, W. M. Bonivento, E. Borisova , et al. (287 additional authors not shown)

    Abstract: The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopi… ▽ More

    Submitted 23 January, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Journal ref: Eur.Phys.J.C 81 (2021) 4, 359

  17. arXiv:2011.07819  [pdf, other

    astro-ph.HE astro-ph.IM physics.ins-det

    Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos

    Authors: P. Agnes, S. Albergo, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, S. Arcelli, M. Ave, I. Ch. Avetissov, R. I. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, V. Barbarian, A. Barrado Olmedo, P. Barrillon, A. Basco, G. Batignani, A. Bondar, W. M. Bonivento, E. Borisova, B. Bottino, M. G. Boulay, G. Buccino , et al. (251 additional authors not shown)

    Abstract: Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and AR… ▽ More

    Submitted 31 December, 2020; v1 submitted 16 November, 2020; originally announced November 2020.

    Comments: 21 pages, 8 figures

  18. arXiv:2009.11757  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Characterization of Germanium Detectors for the First Underground Laboratory in Mexico

    Authors: A. Aguilar-Arevalo, S. Alvarado-Mijangos, X. Bertou, C. Canet, M. A. Cruz-Pérez, A. Deisting, A. Dias, J. C. D'Olivo, F. Favela-Pérez, E. A. Garcés, A. González Muñoz, J. O. Guerra-Pulido, J. Mancera-Alejandrez, D. J. Marín-Lámbarri, M. Martínez Montero, J. Monroe, C. Iván Ortega-Hernández, S. Paling, S. Peeters, D. Ruíz Esparza Rodríguez, P. R. Scovell, C. Türkoğlu, E. Vázquez-Jáuregui, J. Walding

    Abstract: This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak ef… ▽ More

    Submitted 24 September, 2020; originally announced September 2020.

    Comments: 18 pages, 13 figures

  19. arXiv:2009.11227  [pdf, other

    physics.ins-det physics.app-ph

    Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

    Authors: Alexis Aguilar-Arevalo, Xavier Bertou, Carles Canet, Miguel Angel Cruz-Perez, Alexander Deisting, Adriana Dias, Juan Carlos D'Olivo, Francisco Favela-Perez, Estela A. Garces, Adiv Gonzalez Munoz, Jaime Octavio Guerra-Pulido, Javier Mancera-Alejandrez, Daniel Jose Marin-Lambarri, Mauricio Martinez Montero, Jocelyn Monroe, Sean Paling, Simon J. M. Peeters, Paul Scovell, Cenk Turkoglu, Eric Vazquez-Jauregui, Joseph Walding

    Abstract: This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $γ$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance a… ▽ More

    Submitted 23 September, 2020; originally announced September 2020.

  20. arXiv:2007.15609  [pdf, other

    physics.ins-det hep-ex

    Off-Axis Characterisation of the CERN T10 Beam for low Momentum Proton Measurements with a High Pressure Gas Time Projection Chamber

    Authors: S. B. Jones, T. S. Nonnenmacher, E. Atkin, G. J. Barker, A. Basharina-Freshville, C. Betancourt, S. B. Boyd, D. Brailsford, Z. Chen-Wishart, L. Cremonesi, A. Deisting, A. Dias, P. Dunne, J. Haigh, P. Hamacher-Baumann, A. Kaboth, A. Korzenev, W. Ma, P. Mermod, M. Mironova, J. Monroe, R. Nichol, J. Nowak, W. Parker, H. Ritchie-Yates , et al. (11 additional authors not shown)

    Abstract: We present studies of proton fluxes in the T10 beamline at CERN. A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon. To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at… ▽ More

    Submitted 30 July, 2020; originally announced July 2020.

    Comments: 28 pages, 30 figures

    Journal ref: Instruments (2020), 4, 21

  21. arXiv:2004.02024  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Authors: The DarkSide collaboration, C. E. Aalseth, S. Abdelhakim, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, V. Barbaryan, A. Barrado Olmedo, G. Batignani , et al. (290 additional authors not shown)

    Abstract: Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the… ▽ More

    Submitted 26 February, 2021; v1 submitted 4 April, 2020; originally announced April 2020.

    Comments: 26 pages, 22 figures, 3 tables

    Journal ref: Eur. Phys. J. C (2021) 81: 153

  22. The liquid-argon scintillation pulseshape in DEAP-3600

    Authors: The DEAP collaboration, P. Adhikari, R. Ajaj, G. R. Araujoand M. Batygov, B. Beltran, C. E. Bina, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Cárdenas-Montes, S. Cavuoti, Y. Chen, B. T. Cleveland, J. M. Corning, S. J. Daughertyand K. Dering, L. Doria, F. A. Duncan andM. Dunford, A. Erlandson, N. Fatemighomi, G. Fiorillo, A. Flower, R. J. Ford, R. Gagnon , et al. (76 additional authors not shown)

    Abstract: DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed… ▽ More

    Submitted 8 June, 2020; v1 submitted 27 January, 2020; originally announced January 2020.

    Journal ref: Eur. Phys. J. C 80, 303 (2020)

  23. arXiv:2001.08106  [pdf, other

    astro-ph.IM physics.ins-det

    Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

    Authors: The DarkSide Collaboration, C. E. Aalseth, S. Abdelhakim, F. Acerbi, P. Agnes, R. Ajaj, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Amaudruz, F. Ameli, J. Anstey, P. Antonioli, M. Arba, S. Arcelli, R. Ardito, I. J. Arnquist, P. Arpaia, D. M. Asner, A. Asunskis, M. Ave, H. O. Back, A. Barrado Olmedo, G. Batignani , et al. (306 additional authors not shown)

    Abstract: Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa… ▽ More

    Submitted 22 January, 2020; originally announced January 2020.

    Comments: 13 pages, 8 figures. Corresponding author: E. Sánchez García

  24. Triplet Lifetime in Gaseous Argon

    Authors: Michael Akashi-Ronquest, Amanda Bacon, Christopher Benson, Kolahal Bhattacharya, Thomas Caldwell, Joseph A. Formaggio, Dan Gastler, Brianna Grado-White, Jeff Griego, Michael Gold, Andrew Hime, Christopher M. Jackson, Stephen Jaditz, Chris Kachulis, Edward Kearns, Joshua R. Klein, Antonio Ledesma, Steve Linden, Frank Lopez, Sean MacMullin, Andrew Mastbaum, Jocelyn Monroe, James Nikkel, John Oertel, Gabriel D. Orebi Gann , et al. (5 additional authors not shown)

    Abstract: MiniCLEAN is a single-phase liquid argon dark matter experiment. During the initial cooling phase, impurities within the cold gas ($<$140 K) were monitored by measuring the scintillation light triplet lifetime, and ultimately a triplet lifetime of 3.480 $\pm$ 0.001 (stat.) $\pm$ 0.064 (sys.) $μ$s was obtained, indicating ultra-pure argon. This is the longest argon triplet time constant ever report… ▽ More

    Submitted 29 August, 2019; v1 submitted 15 March, 2019; originally announced March 2019.

  25. arXiv:1805.04163  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    Hyper-Kamiokande Design Report

    Authors: Hyper-Kamiokande Proto-Collaboration, :, K. Abe, Ke. Abe, H. Aihara, A. Aimi, R. Akutsu, C. Andreopoulos, I. Anghel, L. H. V. Anthony, M. Antonova, Y. Ashida, V. Aushev, M. Barbi, G. J. Barker, G. Barr, P. Beltrame, V. Berardi, M. Bergevin, S. Berkman, L. Berns, T. Berry, S. Bhadra, D. Bravo-Berguño, F. d. M. Blaszczyk , et al. (291 additional authors not shown)

    Abstract: On the strength of a double Nobel prize winning experiment (Super)Kamiokande and an extremely successful long baseline neutrino programme, the third generation Water Cherenkov detector, Hyper-Kamiokande, is being developed by an international collaboration as a leading worldwide experiment based in Japan. The Hyper-Kamiokande detector will be hosted in the Tochibora mine, about 295 km away from th… ▽ More

    Submitted 28 November, 2018; v1 submitted 9 May, 2018; originally announced May 2018.

    Comments: 325 pages

  26. arXiv:1710.06724  [pdf, other

    physics.geo-ph hep-ex hep-ph

    Exploring the hidden interior of the Earth with directional neutrino measurements

    Authors: Michael Leyton, Stephen Dye, Jocelyn Monroe

    Abstract: Roughly 40% of the Earth's total heat flow is powered by radioactive decays in the crust and mantle. Geo-neutrinos produced by these decays provide important clues about the origin, formation and thermal evolution of our planet, as well as the composition of its interior. Previous measurements of geo-neutrinos have all relied on the detection of inverse beta decay reactions, which are insensitive… ▽ More

    Submitted 19 October, 2017; v1 submitted 18 October, 2017; originally announced October 2017.

    Comments: 18 pages, 11 figures, 8 tables

    Journal ref: Nat. Commun. 8:15989 (2017)

  27. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, M. Ave, H. O. Back, A. I. Barrado Olmedo, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino , et al. (260 additional authors not shown)

    Abstract: Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a… ▽ More

    Submitted 25 July, 2017; originally announced July 2017.

    Report number: FERMILAB-PUB-17-298-PPD

    Journal ref: Aalseth, C.E., Acerbi, F., Agnes, P. et al. Eur. Phys. J. Plus (2018) 133: 131

  28. In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

    Authors: DEAP Collaboration, P. -A. Amaudruz, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, S. Churchwell, B. T. Cleveland, D. Cranshaw, K. Dering, S. Dittmeier, F. A. Duncan, M. Dunford, A. Erlandson , et al. (77 additional authors not shown)

    Abstract: The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile… ▽ More

    Submitted 29 January, 2019; v1 submitted 29 May, 2017; originally announced May 2017.

    Journal ref: Nucl. Instrum. Methods Phys. Res. A 922, 373-384 (2019)

  29. Cryogenic Characterization of FBK RGB-HD SiPMs

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Ampudia, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, H. O. Back, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, R. Bunker , et al. (246 additional authors not shown)

    Abstract: We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio… ▽ More

    Submitted 12 September, 2017; v1 submitted 19 May, 2017; originally announced May 2017.

  30. arXiv:1705.05965  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Measurement of the directional sensitivity of DMTPC detectors

    Authors: Cosmin Deaconu, Michael Leyton, Ross Corliss, Gabriela Druitt, Richard Eggleston, Natalia Guerrero, Shawn Henderson, Jeremy Lopez, Jocelyn Monroe, Peter Fisher

    Abstract: The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30-60 torr, to develop and validate a model of the directional response and perfo… ▽ More

    Submitted 29 May, 2017; v1 submitted 16 May, 2017; originally announced May 2017.

    Comments: 13 pages, 10 figures. Accepted for publication in Phys. Rev. D. Added color figures, switched to more compact layout, and fixed some references

    Journal ref: Phys. Rev. D 95, 122002 (2017)

  31. arXiv:1705.00696  [pdf, ps, other

    hep-ex nucl-ex physics.ins-det

    The search for neutron-antineutron oscillations at the Sudbury Neutrino Observatory

    Authors: SNO Collaboration, B. Aharmim, S. N. Ahmed, A. E. Anthony, N. Barros, E. W. Beier, A. Bellerive, B. Beltran, M. Bergevin, S. D. Biller, K. Boudjemline, M. G. Boulay, B. Cai, Y. D. Chan, D. Chauhan, M. Chen, B. T. Cleveland, G. A. Cox, X. Dai, H. Deng, J. A. Detwiler, P. J. Doe, G. Doucas, P. -L. Drouin, F. A. Duncan , et al. (100 additional authors not shown)

    Abstract: Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within t… ▽ More

    Submitted 1 May, 2017; originally announced May 2017.

    Comments: 14 pages, 8 figures

    Journal ref: Phys. Rev. D 96, 092005 (2017)

  32. A method for characterizing after-pulsing and dark noise of PMTs and SiPMs

    Authors: A. Butcher, L. Doria, J. Monroe, F. Retiere, B. Smith, J. Walding

    Abstract: Photo-multiplier tubes (PMTs) and silicon photo-multipliers (SiPMs) are detectors sensitive to single photons that are widely used for the detection of scintillation and Cerenkov light in subatomic physics and medical imaging. This paper presents a method for characterizing two of the main noise sources that PMTs and SiPMs share: dark noise and correlated noise (after-pulsing). The proposed method… ▽ More

    Submitted 21 August, 2017; v1 submitted 17 March, 2017; originally announced March 2017.

    Comments: Accepted by Nucl. Instr. Meth. A. 11 pages, 8 figures. Added application of method to SiPM data in new version

  33. arXiv:1611.06118  [pdf, other

    hep-ex hep-ph physics.ins-det

    Physics Potentials with the Second Hyper-Kamiokande Detector in Korea

    Authors: Hyper-Kamiokande proto-collaboration, :, K. Abe, Ke. Abe, S. H. Ahn, H. Aihara, A. Aimi, R. Akutsu, C. Andreopoulos, I. Anghel, L. H. V. Anthony, M. Antonova, Y. Ashida, V. Aushev, M. Barbi, G. J. Barker, G. Barr, P. Beltrame, V. Berardi, M. Bergevin, S. Berkman, L. Berns, T. Berry, S. Bhadra, D. Bravo-Bergu no , et al. (331 additional authors not shown)

    Abstract: Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev… ▽ More

    Submitted 26 March, 2018; v1 submitted 18 November, 2016; originally announced November 2016.

    Comments: 102 pages, 49 figures. Accepted by PTEP

    Journal ref: Prog Theor Exp Phys (2018)

  34. arXiv:1610.02396  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    Readout technologies for directional WIMP Dark Matter detection

    Authors: J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas , et al. (68 additional authors not shown)

    Abstract: The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 58 pages, 26 figures, accepted by Physics Reports

    Journal ref: Physics Reports 662 (2016) pp. 1-46

  35. arXiv:1606.08114  [pdf, other

    physics.ins-det hep-ex

    TITUS: the Tokai Intermediate Tank for the Unoscillated Spectrum

    Authors: C. Andreopoulos, F. C. T. Barbato, G. Barker, G. Barr, P. Beltrame, V. Berardi, T. Berry, A. Blondel, S. Boyd, A. Bravar, F. S. Cafagna, S. Cartwright, M. G. Catanesi, C. Checchia, A. Cole, G. Collazuol, G. A. Cowan, T. Davenne, T. Dealtry, C. Densham, G. De Rosa, F. Di Lodovico, E. Drakopoulou, P. Dunne, A. Finch , et al. (53 additional authors not shown)

    Abstract: The TITUS, Tokai Intermediate Tank for Unoscillated Spectrum, detector, is a proposed Gd-doped Water Cherenkov tank with a magnetised muon range detector downstream. It is located at J-PARC at about 2 km from the neutrino target and it is proposed as a potential near detector for the Hyper-Kamiokande experiment. Assuming a beam power of 1.3 MW and 27.05 x 10^{21} protons-on-target the sensitivity… ▽ More

    Submitted 1 November, 2016; v1 submitted 26 June, 2016; originally announced June 2016.

    Comments: 70 pages, 41 figures

  36. arXiv:1602.03781  [pdf, ps, other

    astro-ph.CO hep-ph physics.ins-det

    A review of the discovery reach of directional Dark Matter detection

    Authors: F. Mayet, A. M. Green, J. B. R. Battat, J. Billard, N. Bozorgnia, G. B. Gelmini, P. Gondolo, B. J. Kavanagh, S. K. Lee, D. Loomba, J. Monroe, B. Morgan, C. A. J. O'Hare, A. H. G. Peter, N. S. Phan, S. E. Vahsen

    Abstract: Cosmological observations indicate that most of the matter in the Universe is Dark Matter. Dark Matter in the form of Weakly Interacting Massive Particles (WIMPs) can be detected directly, via its elastic scattering off target nuclei. Most current direct detection experiments only measure the energy of the recoiling nuclei. However, directional detection experiments are sensitive to the direction… ▽ More

    Submitted 17 March, 2016; v1 submitted 11 February, 2016; originally announced February 2016.

    Comments: 57 pages, 23 figures, to appear in Physics Reports

    Journal ref: Physics Reports 627 (2016) 1

  37. arXiv:1502.04213  [pdf, other

    physics.ins-det

    Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenon

    Authors: Emily Grace, Alistair Butcher, Jocelyn Monroe, James A. Nikkel

    Abstract: Large liquid argon detectors have become widely used in low rate experiments, including dark matter and neutrino research. However, the optical properties of liquid argon are not well understood at the large scales relevant for current and near-future detectors.The index of refraction of liquid argon at the scin- tillation wavelength has not been measured, and current Rayleigh scattering length ca… ▽ More

    Submitted 11 August, 2017; v1 submitted 14 February, 2015; originally announced February 2015.

    Comments: 11 pages, 4 figures

  38. arXiv:1412.4673  [pdf, other

    physics.ins-det hep-ex hep-ph

    A Long Baseline Neutrino Oscillation Experiment Using J-PARC Neutrino Beam and Hyper-Kamiokande

    Authors: Hyper-Kamiokande Working Group, :, K. Abe, H. Aihara, C. Andreopoulos, I. Anghel, A. Ariga, T. Ariga, R. Asfandiyarov, M. Askins, J. J. Back, P. Ballett, M. Barbi, G. J. Barker, G. Barr, F. Bay, P. Beltrame, V. Berardi, M. Bergevin, S. Berkman, T. Berry, S. Bhadra, F. d. M. Blaszczyk, A. Blondel, S. Bolognesi , et al. (224 additional authors not shown)

    Abstract: Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of $CP$ asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams. In this document, the physics potential o… ▽ More

    Submitted 18 January, 2015; v1 submitted 15 December, 2014; originally announced December 2014.

    Comments: Document submitted to 18th J-PARC PAC meeting in May 2014. 50 pages, 41 figures

  39. arXiv:1410.7673  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    DEAP-3600 Dark Matter Search

    Authors: DEAP Collaboration, P. -A. Amaudruz, M. Batygov, B. Beltran, J. Bonatt, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, M. Chen, R. Chouinard, B. T. Cleveland, K. Dering, J. DiGioseffo, F. Duncan, T. Flower, R. Ford, P. Giampa, P. Gorel, K. Graham, D. R. Grant, E. Guliyev, A. L. Hallin, M. Hamstra , et al. (32 additional authors not shown)

    Abstract: The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $β$/$γ$ backgrounds… ▽ More

    Submitted 25 August, 2015; v1 submitted 27 October, 2014; originally announced October 2014.

    Comments: International Conference on High Energy Physics (ICHEP 2014), Valencia, 2014

    Journal ref: Nuclear and Particle Physics Proceedings 273-275 (2016) 340-346

  40. arXiv:1408.1914  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Authors: M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov, B. Beltran, M. Bodmer, M. G. Boulay, B. Broerman, B. Buck, A. Butcher, B. Cai, T. Caldwell, M. Chen, Y. Chen, B. Cleveland, K. Coakley, K. Dering, F. A. Duncan, J. A. Formaggio, R. Gagnon, D. Gastler, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel, K. Graham , et al. (57 additional authors not shown)

    Abstract: Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We… ▽ More

    Submitted 12 December, 2014; v1 submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 16 figures

  41. arXiv:1403.4842  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Update on the MiniCLEAN Dark Matter Experiment

    Authors: K. Rielage, M. Akashi-Ronquest, M. Bodmer, R. Bourque, B. Buck, A. Butcher, T. Caldwell, Y. Chen, K. Coakley, E. Flores, J. A. Formaggio, D. Gastler, F. Giuliani, M. Gold, E. Grace, J. Griego, N. Guerrero, V. Guiseppe, R. Henning, A. Hime, S. Jaditz, C. Kachulis, E. Kearns, J. Kelsey, J. R. Klein , et al. (21 additional authors not shown)

    Abstract: The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o… ▽ More

    Submitted 19 March, 2014; originally announced March 2014.

    Comments: To appear in the Proceedings of the TAUP 2013 Conference (F. Avignone & W. Haxton, editors, Physics Procedia, Elsevier)

    Report number: LA-UR-14-21626

  42. Design of the MiniCLEAN dark matter search veto detector subsystem

    Authors: Robert Abruzzio, Benjamin Buck, Stephen Jaditz, James Kelsey, Jocelyn Monroe, Kimberyl Palladino

    Abstract: This paper describes the design of the active muon veto subsystem for the MiniCLEAN dark matter direct detection experiment at SNOLAB in Sudbury, Ontario, Canada. The water-filled veto is instrumented with 48 PMTs which are read out by front end electronics to time multiplex 48 photomultiplier channels into 6 digitizer channels and provide an instantaneous hit sum across the subsystem (N-Hit) for… ▽ More

    Submitted 6 March, 2014; originally announced March 2014.

    Comments: 11 Pages

  43. arXiv:1301.5685  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Background Rejection in the DMTPC Dark Matter Search Using Charge Signals

    Authors: J. P. Lopez, D. Dujmic, S. Ahlen, J. B. R. Battat, C. Deaconu, P. Fisher, S. Henderson, A. Inglis, A. Kaboth, J. Monroe, G. Sciolla, H. Tomita, H. Wellenstein, R. Yamamoto

    Abstract: The Dark Matter Time Projection Chamber (DMTPC) collaboration is develo** a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of the daily modulation of the direction of the dark matter wind. In order to reach sensitivities required for WIMP detection, the detector needs to minimize backgr… ▽ More

    Submitted 28 January, 2013; v1 submitted 23 January, 2013; originally announced January 2013.

    Comments: 18 pages, 12 figures. Preprint accepted by NIM A

    Journal ref: Nucl.Instr.Meth. A696 (2012), 121-128

  44. arXiv:1111.0220  [pdf, other

    physics.ins-det

    Status and Prospects of the DMTPC Directional Dark Matter Experiment

    Authors: Jocelyn Monroe

    Abstract: The DMTPC directional dark matter detection experiment is a low-pressure CF4 gas time projection chamber, instrumented with charge and scintillation photon readout. This detector design strategy emphasizes reconstruction of WIMP-induced nuclear recoil tracks, in order to determine the direction of incident dark matter particles. Directional detection has the potential to make the definitive observ… ▽ More

    Submitted 1 November, 2011; originally announced November 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

  45. arXiv:1109.3501  [pdf, ps, other

    astro-ph.IM hep-ex physics.ins-det

    Background Rejection in the DMTPC Dark Matter Search Using Charge Signals

    Authors: J. P. Lopez, S. Ahlen, J. Battat, T. Caldwell, M. Chernicoff, C. Deaconu, D. Dujmic, A. Dushkin, W. Fedus, P. Fisher, F. Golub, S. Henderson, A. Inglis, A. Kaboth, G. Kohse, L. Kirsch, R. Lanza, A. Lee, J. Monroe, H. Ouyang, T. Sahin, G. Sciolla, N. Skvorodnev, H. Tomita, H. Wellenstein , et al. (3 additional authors not shown)

    Abstract: The Dark Matter Time Projection Chamber (DMTPC) collaboration is develo** low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that… ▽ More

    Submitted 15 September, 2011; originally announced September 2011.

    Comments: 8 pages, 6 figures. For proceedings of DPF 2011 conference

  46. arXiv:1104.2573  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    A Monte Carlo simulation of the Sudbury Neutrino Observatory proportional counters

    Authors: B. Beltran, H. Bichsel, B. Cai, H. Deng, J. A. Formaggio, S. Habib, A. L. Hallin, A. Hime, M. Huang, C. Kraus, H. R. Leslie, J. C. Loach, R. Martin, S. McGee, M. L. Miller, B. Monreal, J. Monroe, N. S. Oblath, S. J. M. Peeters, A. W. P. Poon, G. Prior, K. Rielage, R. G. H. Robertson, M. W. E. Smith, L. C. Stonehill , et al. (6 additional authors not shown)

    Abstract: The third phase of the Sudbury Neutrino Observatory (SNO) experiment added an array of 3He proportional counters to the detector. The purpose of this Neutral Current Detection (NCD) array was to observe neutrons resulting from neutral-current solar neutrino-deuteron interactions. We have developed a detailed simulation of the current pulses from the NCD array proportional counters, from the primar… ▽ More

    Submitted 13 April, 2011; originally announced April 2011.

    Comments: 38 pages; submitted to the New Journal of Physics

    Report number: LANL Report #: LA-UR-11-10284

  47. A Background-Free Direction-Sensitive Neutron Detector2 A Background-Free Direction-Sensitive Neutron Detector

    Authors: Alvaro Roccaro, H. Tomita, S. Ahlen, D. Avery, A. Inglis, J. Battat, D. Dujmic, P. Fisher, S. Henderson, A. Kaboth, G. Kohse, R. Lanza, J. Monroe, G. Sciolla, N. Skvorodnev, H. Wellenstein, R. Yamamoto

    Abstract: We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detector… ▽ More

    Submitted 21 June, 2009; originally announced June 2009.

    Comments: 17 pages, 8 figures, Accepted by NIM

  48. arXiv:0905.2549  [pdf, other

    physics.ins-det

    Transport properties of electrons in CF4

    Authors: T. Caldwell, A. Roccaro, T. Sahin, H. Yegoryan, D. Dujmic, S. Ahlen, J. Battat, P. Fisher, S. Henderson, A. Kaboth, G. Kohse, R. Lanza, J. Lopez, J. Monroe, G. Sciolla, N. Skvorodnev, H. Tomita, R. Vanderspek, H. Wellenstein, R. Yamamoto

    Abstract: Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the diffusion coefficent, and the attentuation coefficient of electron propagation in CF4 gas using a 10-liter dark matter detector prototype of the DMTPC project.

    Submitted 15 May, 2009; originally announced May 2009.

    Comments: 12 pages, 8 figures

  49. arXiv:0810.2769  [pdf, other

    physics.ins-det

    DMTPC-10L: Direction-Sensitive Dark Matter Detector Prototype

    Authors: D. Dujmic, P. Fisher, R. Lanza, J. Lopez, A. Kaboth, G. Kohse, J. Monroe, R. Vanderspek, G. Sciolla, R. Yamamoto, S. Ahlen, K. Otis, A. Roccaro, H. Tomita, N. Skvorodnev, H. Wellenstein

    Abstract: The known direction of motion of dark matter particles relative to the Earth may be a key for their unambiguous identification even in the presence of backgrounds. We describe a prototype detector that is able to reconstruct direction vectors of weakly interacting massive particles that may the dominant constituent of the dark matter in our galaxy. The detector uses a low-density gas (CF4) in a… ▽ More

    Submitted 15 October, 2008; originally announced October 2008.

    Comments: Presented at the 34th International Conference on High Energy Physics, Philadelphia, 2008

  50. A Measurement of Photon Production in Electron Avalanches in CF4

    Authors: A. Kaboth, J. Monroe, S. Ahlen, D. Dujmic, S. Henderson, G. Kohse, R. Lanza, M. Lewandowska, A. Roccaro, G. Sciolla, N. Skvorodnev, H. Tomita, R. Vanderspek, H. Wellenstein, R. Yamamoto, P. Fisher

    Abstract: This paper presents a measurement of the ratio of photon to electron production and the scintillation spectrum in a popular gas for time pro jection chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the ratio is measured to be 0.34+/-0.04. This result is of particular importance for a new generation of dark matter time projection chambers with directional sensitivity which u… ▽ More

    Submitted 14 March, 2008; originally announced March 2008.

    Comments: 19 pages, including appendix. 8 figures

    Journal ref: Nucl.Instrum.Meth.A592:63-72,2008