-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter
Authors:
A. H. Abdelhameed,
G. Angloher,
P. Bauer,
A. Bento,
E. Bertoldo,
R. Breier,
C. Bucci,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
V. M. Ghete,
A. Garai,
P. Gorla,
D. Hauff,
M. Ješkovský,
J. Jochum,
J. Kaizer,
M. Kaznacheeva,
A. Kinast
, et al. (34 additional authors not shown)
Abstract:
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cry…
▽ More
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.
△ Less
Submitted 15 December, 2020; v1 submitted 6 May, 2020;
originally announced May 2020.
-
Exploring CEvNS with NUCLEUS at the Chooz Nuclear Power Plant
Authors:
G. Angloher,
F. Ardellier-Desages,
A. Bento,
L. Canonica,
A. Erhart,
N. Ferreiro,
M. Friedl,
V. M. Ghete,
D. Hauff,
H. Kluck,
A. Langenkämper,
T. Lasserre,
D. Lhuillier,
A. Kinast,
M. Mancuso,
J. Molina Rubiales,
E. Mondragon,
G. Munch,
C. Nones,
L. Oberauer,
A. Onillon,
T. Ortmann,
L. Pattavina,
F. Petricca,
W. Potzel
, et al. (12 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a unique way to study neutrino properties and to search for new physics beyond the Standard Model. Nuclear reactors are promising sources to explore this process at low energies since they deliver large fluxes of (anti-)neutrinos with typical energies of a few MeV. In this paper, a new-generation experiment to study CE$ν$NS is described…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a unique way to study neutrino properties and to search for new physics beyond the Standard Model. Nuclear reactors are promising sources to explore this process at low energies since they deliver large fluxes of (anti-)neutrinos with typical energies of a few MeV. In this paper, a new-generation experiment to study CE$ν$NS is described. The NUCLEUS experiment will use cryogenic detectors which feature an unprecedentedly low energy threshold and a time response fast enough to be operated in above-ground conditions. Both sensitivity to low-energy nuclear recoils and a high event rate tolerance are stringent requirements to measure CE$ν$NS of reactor antineutrinos. A new experimental site, denoted the Very-Near-Site (VNS) at the Chooz nuclear power plant in France is described. The VNS is located between the two 4.25 GW$_{\mathrm{th}}$ reactor cores and matches the requirements of NUCLEUS. First results of on-site measurements of neutron and muon backgrounds, the expected dominant background contributions, are given. In this paper a preliminary experimental setup with dedicated active and passive background reduction techniques is presented. Furthermore, the feasibility to operate the NUCLEUS detectors in coincidence with an active muon-veto at shallow overburden is studied. The paper concludes with a sensitivity study pointing out the promising physics potential of NUCLEUS at the Chooz nuclear power plant.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li
Authors:
A. H. Abdelhameed,
G. Angloher,
P. Bauer,
A. Bento,
E. Bertoldo,
C. Bucci,
L. Canonica,
A. D'Addabbo,
X. Defay,
S. Di Lorenzo,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
A. Fuss,
P. Gorla,
D. Hauff,
J. Jochum,
A. Kinast,
H. Kluck,
H. Kraus,
A. Langenkämper,
M. Mancuso,
V. Mokina,
E. Mondragon
, et al. (31 additional authors not shown)
Abstract:
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin…
▽ More
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
△ Less
Submitted 4 September, 2019; v1 submitted 20 February, 2019;
originally announced February 2019.
-
A prototype detector for the CRESST-III low-mass dark matter search
Authors:
R. Strauss,
G. Angloher,
P. Bauer,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
R. Hampf,
D. Hauff,
M. Kiefer,
J. -C. Lanfranchi,
A. Langenkämper,
E. Mondragon,
A. Münster,
C. Oppenheimer,
F. Petricca,
W. Potzel,
F. Pröbst,
F. Reindl,
J. Rothe,
S. Schönert,
W. Seidel,
H. Steiger,
L. Stodolsky,
A. Tanzke
, et al. (6 additional authors not shown)
Abstract:
The CRESST-III experiment which is dedicated to low-mass dark matter search uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors. Background discrimination is achieved by exploiting the scintillating light signal of CaWO$_4$ and by a novel active detector holder presented in this paper. In a test setup above ground, a nuclear-recoil energy threshold of…
▽ More
The CRESST-III experiment which is dedicated to low-mass dark matter search uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors. Background discrimination is achieved by exploiting the scintillating light signal of CaWO$_4$ and by a novel active detector holder presented in this paper. In a test setup above ground, a nuclear-recoil energy threshold of $E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which corresponds to an estimated threshold of $\sim$50eV when being operated in the low-noise CRESST cryostat. This is the lowest threshold reported for direct dark matter searches. For CRESST-III phase 1, ten such detector modules were installed in the cryostat which have the potential to improve significantly the sensitivity to scatterings of dark matter particles with masses down to $\sim$0.1GeV/c$^2$.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
A. Langenkämper J. Loebell,
M. Mancuso,
E. Mondragon,
A. Münster,
L. Oberauer,
C. Pagliarone,
F. Petricca,
W. Potzel
, et al. (22 additional authors not shown)
Abstract:
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $ν$-cleus e…
▽ More
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $ν$-cleus experiment has achieved an energy threshold of $E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous results and independent of the type of particle interaction. The result presented here is obtained in a setup above ground without significant shielding against ambient and cosmogenic radiation. Although operated in a high-background environment, the detector probes a new range of light-mass dark matter particles previously not accessible by direct searches. We report the first limit on the spin-independent dark matter particle-nucleon cross section for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
△ Less
Submitted 18 September, 2017; v1 submitted 20 July, 2017;
originally announced July 2017.
-
Silicon PIN diodes as Neganov-Trofimov-Luke cryogenic light detectors
Authors:
X. Defay,
E. Mondragon,
J. -C. Lanfranchi,
A. Langenkamper,
A. Munster,
W. Potzel,
S. Schonert,
S. Wawoczny,
M. Willers
Abstract:
Cryogenic rare event searches based on heat and light composite calorimeters have a common need for large area photon detectors with high quantum efficiency, good radiopurity and high sensitivity. By employing the Neganov-Trofimov-Luke effect (NTLE), the phonon signal of particle interactions in a semiconductor absorber operated at cryogenic temperatures can be amplified by drifting the photogener…
▽ More
Cryogenic rare event searches based on heat and light composite calorimeters have a common need for large area photon detectors with high quantum efficiency, good radiopurity and high sensitivity. By employing the Neganov-Trofimov-Luke effect (NTLE), the phonon signal of particle interactions in a semiconductor absorber operated at cryogenic temperatures can be amplified by drifting the photogenerated electrons and holes in an electric field. We present here the last results of a Neganov-Trofimov-Luke effect light detector with an electric field configuration optimized to improve the charge collection within the absorber.
△ Less
Submitted 14 February, 2018; v1 submitted 17 July, 2017;
originally announced July 2017.
-
Low-Temperature Relative Reflectivity Measurements of Reflective and Scintillating Foils used in Rare Event Searches
Authors:
A. Langenkämper,
A. Ulrich,
X. Defay,
F. v. Feilitzsch,
J. -C. Lanfranchi,
E. Mondragón,
A. Münster,
C. Oppenheimer,
W. Potzel,
S. Roth,
S. Schönert,
H. Steiger,
H. H. Trinh Thi,
S. Wawoczny,
M. Willers,
A. Zöller
Abstract:
In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO$_4$ crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the…
▽ More
In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO$_4$ crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO$_4$ target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay ($0νββ$). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no significant change in the reflectivity with temperature for all foils studied.
△ Less
Submitted 20 December, 2017; v1 submitted 21 March, 2017;
originally announced March 2017.
-
Cryogenic silicon detectors with implanted contacts for the detection of visible photons using the Neganov-Luke Effect
Authors:
X. Defay,
E. Mondragon,
M. Willers,
A. Langenkamper,
J. -C. Lanfranchi,
A. Munstera,
A. Zoller,
S. Wawoczny,
H. Steiger,
F. Hitzler,
C. Bruhn,
S. Schonert,
W. Potzel,
M. Chapellier
Abstract:
There is a common need in astroparticle experiments such as direct dark matter detection, 0ν\b{eta}\b{eta} (double beta decay without emission of neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light detectors with a very low energy threshold. By employing the Neganov-Luke Effect, the thermal signal of particle interactions in a semiconductor absorber operated at cryogenic temp…
▽ More
There is a common need in astroparticle experiments such as direct dark matter detection, 0ν\b{eta}\b{eta} (double beta decay without emission of neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light detectors with a very low energy threshold. By employing the Neganov-Luke Effect, the thermal signal of particle interactions in a semiconductor absorber operated at cryogenic temperatures, can be amplified by drifting the photogenerated electrons and holes in an electric field. This technology is not used in current experiments, in particular because of a reduction of the signal amplitude with time which is due to trap** of the charges within the absorber. We present here the first results of a novel type of Neganov-Luke Effect detector with an electric field configuration designed to improve the charge collection within the semiconductor.
△ Less
Submitted 28 January, 2016; v1 submitted 21 September, 2015;
originally announced September 2015.