Skip to main content

Showing 1–4 of 4 results for author: Momose, A

Searching in archive physics. Search in all archives.
.
  1. arXiv:2005.06131  [pdf

    physics.ins-det

    Enhancement of low-spatial-frequency components by a new phase-contrast STEM using a probe formed with an amplitude Fresnel zone plate

    Authors: Masato Tomita, Yukinori Nagatani, Kazuyoshi Murata, Atsushi Momose

    Abstract: Electron microscopy is a powerful tool for visualizing the shapes of sub-nanometer objects. However, contrast is not in proportional to density distribution, and therefore achieving a quantitative understanding of specimens is not straightforward, especially for low-contrast subjects such as biological specimens. To overcome this problem, we have developed a new phase-contrast scanning transmissio… ▽ More

    Submitted 12 May, 2020; originally announced May 2020.

    Comments: 18 pages including 12 figures

  2. arXiv:1501.02439  [pdf

    physics.optics

    Research on the background correction method in x-ray phase contrast imaging with Talbot-Lau interferometer

    Authors: Shenghao Wang, Can Zhang, Margie P. Olbinado, Atsushi Momose, Kun Gao, Zhili Wang, Huajie Han, Meng Yang, Kai Zhang, Pei** Zhu, Ziyu Wu

    Abstract: X-ray Talbot-Lau interferometer has been used widely to conduct phase contrast imaging with a conventional low-brilliance x-ray source. Typically, in this technique, background correction has to be performed in order to obtain the pure signal of the sample under inspection. In this study, we reported on a research on the background correction strategies within this technique, especially we introdu… ▽ More

    Submitted 9 March, 2015; v1 submitted 11 January, 2015; originally announced January 2015.

    Comments: 23 pages, 8 figures, english polished

  3. Experimental research on the feature of an X-ray Talbot-Lau interferometer vs. tube accelerating voltage

    Authors: Shenghao Wang, Renfang Hu, Zhili Wang, Kun Gao, Kai Zhang, Atsushi Momose, Ziyu Wu

    Abstract: X-ray Talbot-Lau interferometer has been used most widely to perform X-ray phase-contrast imaging with a conventional low-brilliance X-ray source, it yields high-sensitivity phase and dark-field images of sample producing low absorption contrast, thus bearing tremendous potential for future clinical diagnosis. In this manuscript, while changing accelerating voltage of the X-ray tube from 35KV to 4… ▽ More

    Submitted 19 November, 2014; v1 submitted 28 October, 2014; originally announced October 2014.

    Comments: 9 pages, 7 figures.(English improved and discussion part revised)

    Journal ref: Chin. Phys. B, 2015, 24(6):068703

  4. arXiv:1106.5101  [pdf

    physics.med-ph physics.optics

    Fourier transform based iterative method for x-ray differential phase-contrast computed tomography

    Authors: Wenxiang Cong, Atsushi Momose, Ge Wang

    Abstract: Biological soft tissues encountered in clinical and pre-clinical imaging mainly consist of light element atoms, and their composition is nearly uniform with little density variation. Thus, x-ray attenuation imaging suffers from low image contrast resolution. By contrast, x-ray phase shift of soft tissues is about a thousand times greater than x-ray absorption over the diagnostic energy range, ther… ▽ More

    Submitted 24 June, 2011; originally announced June 2011.