-
Selective intracellular delivery and intracellular recordings combined on MEA biosensors
Authors:
Andrea Cerea,
Valeria Caprettini,
Giulia Bruno,
Laura Lovato,
Giovanni Melle,
Francesco Tantussi,
Rosario Capozza,
Fabio Moia,
Michele Dipalo,
Francesco De Angelis
Abstract:
Biological studies on in vitro cell cultures are of fundamental importance to investigate cells response to external stimuli, such as new drugs for treatment of specific pathologies, or to study communication between electrogenic cells. Although three-dimensional (3D) nanostructures brought tremendous improvements on biosensors used for various biological in vitro studies, including drug delivery…
▽ More
Biological studies on in vitro cell cultures are of fundamental importance to investigate cells response to external stimuli, such as new drugs for treatment of specific pathologies, or to study communication between electrogenic cells. Although three-dimensional (3D) nanostructures brought tremendous improvements on biosensors used for various biological in vitro studies, including drug delivery and electrical recording, there is still a lack of multifunctional capabilities that could help gaining deeper insights in several bio-related research fields. In this work, the electrical recording of large cell ensembles and the intracellular delivery of few selected cells are combined on the same device by integrating microfluidics channels on the bottom of a multi-electrode array decorated with 3D hollow nanostructures. The novel platform allows to record intracellular-like action potentials from large ensembles of cardiomyocytes derived from human Induced Pluripotent Stem Cells (hiPSC) and from the HL-1 line, while different molecules are selectively delivered into single/few targeted cells. The proposed approach shows high potential for enabling new comprehensive studies that can relate drug effects to network level cell communication processes.
△ Less
Submitted 23 August, 2018;
originally announced August 2018.
-
Cell membrane disruption by vertical nanopillars: the role of membrane bending and traction forces
Authors:
Rosario Capozza,
Valeria Caprettini,
Carlo A. Gonano,
Alessandro Bosca,
Fabio Moia,
Francesca Santoro,
Francesco De Angelis
Abstract:
Gaining access to the cell interior is fundamental for many applications, such as electrical recording, drug and biomolecular delivery. A very promising technique consists of culturing cells on nano/micro pillars. The tight adhesion and high local deformation of cells in contact with nanostructures can promote the permeabilization of lipids at the plasma membrane, providing access to the internal…
▽ More
Gaining access to the cell interior is fundamental for many applications, such as electrical recording, drug and biomolecular delivery. A very promising technique consists of culturing cells on nano/micro pillars. The tight adhesion and high local deformation of cells in contact with nanostructures can promote the permeabilization of lipids at the plasma membrane, providing access to the internal compartment. However, there is still much experimental controversy regarding when and how the intracellular environment is targeted and the role of the geometry and interactions with surfaces. Consequently, we investigated, by coarse-grained molecular dynamics simulations of the cell membrane, the mechanical properties of the lipid bilayer under high strain and bending conditions. We found out that a high curvature of the lipid bilayer dramatically lowers the traction force necessary to achieve membrane rupture. Afterwards, we experimentally studied the permeabilization rate of cell membrane by pillars with comparable aspect ratios but different sharpness values at the edges. The experimental data support the simulation results: even pillars with diameters in the micron range may cause local membrane disruption when their edges are sufficiently sharp. Therefore, the permeabilization likelihood is connected to the local geometric features of the pillars rather than diameter or aspect ratio. The present study can also provide significant contributions to the design of 3D biointerfaces for tissue engineering and cellular growth.
△ Less
Submitted 27 April, 2018;
originally announced April 2018.
-
Annihilation of low energy antiprotons in silicon
Authors:
S. Aghion,
O. Ahlén,
A. S. Belov,
G. Bonomi,
P. Bräunig,
J. Bremer,
R. S. Brusa,
G. Burghart,
L. Cabaret,
M. Caccia,
C. Canali,
R. Caravita,
F. Castelli,
G. Cerchiari,
S. Cialdi,
D. Comparat,
G. Consolati,
J. H. Derking,
S. Di Domizio,
L. Di Noto,
M. Doser,
A. Dudarev,
R. Ferragut,
A. Fontana,
P. Genova
, et al. (34 additional authors not shown)
Abstract:
The goal of the AE$\mathrm{\bar{g}}$IS experiment at the Antiproton Decelerator (AD) at CERN, is to measure directly the Earth's gravitational acceleration on antimatter. To achieve this goal, the AE$\mathrm{\bar{g}}$IS collaboration will produce a pulsed, cold (100 mK) antihydrogen beam with a velocity of a few 100 m/s and measure the magnitude of the vertical deflection of the beam from a straig…
▽ More
The goal of the AE$\mathrm{\bar{g}}$IS experiment at the Antiproton Decelerator (AD) at CERN, is to measure directly the Earth's gravitational acceleration on antimatter. To achieve this goal, the AE$\mathrm{\bar{g}}$IS collaboration will produce a pulsed, cold (100 mK) antihydrogen beam with a velocity of a few 100 m/s and measure the magnitude of the vertical deflection of the beam from a straight path. The final position of the falling antihydrogen will be detected by a position sensitive detector. This detector will consist of an active silicon part, where the annihilations take place, followed by an emulsion part. Together, they allow to achieve 1$%$ precision on the measurement of $\bar{g}$ with about 600 reconstructed and time tagged annihilations.
We present here, to the best of our knowledge, the first direct measurement of antiproton annihilation in a segmented silicon sensor, the first step towards designing a position sensitive silicon detector for the AE$\mathrm{\bar{g}}$IS experiment. We also present a first comparison with Monte Carlo simulations (GEANT4) for antiproton energies below 5 MeV
△ Less
Submitted 11 March, 2014; v1 submitted 20 November, 2013;
originally announced November 2013.
-
Prospects for measuring the gravitational free-fall of antihydrogen with emulsion detectors
Authors:
AEgIS Collaboration,
S. Aghion,
O. Ahlén,
C. Amsler,
A. Ariga,
T. Ariga,
A. S. Belov,
G. Bonomi,
P. Bräunig,
J. Bremer,
R. S. Brusa,
L. Cabaret,
C. Canali,
R. Caravita,
F. Castelli,
G. Cerchiari,
S. Cialdi,
D. Comparat,
G. Consolati,
J. H. Derking,
S. Di Domizio,
L. Di Noto,
M. Doser,
A. Dudarev,
A. Ereditato
, et al. (46 additional authors not shown)
Abstract:
The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. AEgIS will measure the free-fall of an antihydrogen beam traversing a moiré deflectometer. The goal is to determine the gravitational acceleration g for antihydrogen with an initial relative accuracy of 1% by using an emulsion detector combined with a silicon micro-strip detector to measure the…
▽ More
The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. AEgIS will measure the free-fall of an antihydrogen beam traversing a moiré deflectometer. The goal is to determine the gravitational acceleration g for antihydrogen with an initial relative accuracy of 1% by using an emulsion detector combined with a silicon micro-strip detector to measure the time of flight. Nuclear emulsions can measure the annihilation vertex of antihydrogen atoms with a precision of about 1 - 2 microns r.m.s. We present here results for emulsion detectors operated in vacuum using low energy antiprotons from the CERN antiproton decelerator. We compare with Monte Carlo simulations, and discuss the impact on the AEgIS project.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.