-
The Belle II Detector Upgrades Framework Conceptual Design Report
Authors:
H. Aihara,
A. Aloisio,
D. P. Auguste,
M. Aversano,
M. Babeluk,
S. Bahinipati,
Sw. Banerjee,
M. Barbero,
J. Baudot,
A. Beaubien,
F. Becherer,
T. Bergauer,
F. U. Bernlochner.,
V. Bertacchi,
G. Bertolone,
C. Bespin,
M. Bessner,
S. Bettarini,
A. J. Bevan,
B. Bhuyan,
M. Bona,
J. F. Bonis,
J. Borah,
F. Bosi,
R. Boudagga
, et al. (186 additional authors not shown)
Abstract:
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit…
▽ More
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.
△ Less
Submitted 4 July, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
B. Acar,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. AlKadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 30 June, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector
Authors:
R. Leboucher,
K. Adamczyk,
L. Aggarwal,
H. Aihara,
T. Aziz,
S. Bacher,
S. Bahinipati,
G. Batignani,
J. Baudot,
P. K. Behera,
S. Bettarini,
T. Bilka,
A. Bozek,
F. Buchsteiner,
G. Casarosa,
L. Corona,
T. Czank,
S. B. Das,
G. Dujany,
C. Finck,
F. Forti,
M. Friedl,
A. Gabrielli,
E. Ganiev,
B. Gobbo
, et al. (56 additional authors not shown)
Abstract:
The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest…
▽ More
The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
The Silicon Vertex Detector of the Belle II Experiment
Authors:
G. Dujany,
K. Adamczyk,
L. Aggarwal,
H. Aihara,
T. Aziz,
S. Bacher,
S. Bahinipati,
G. Batignani,
J. Baudot,
P. K. Behera,
S. Bettarini,
T. Bilka,
A. Bozek,
F. Buchsteiner,
G. Casarosa,
L. Corona,
T. Czank,
S. B. Das,
C. Finck,
F. Forti,
M. Friedl,
A. Gabrielli,
E. Ganiev,
B. Gobbo,
S. Halder
, et al. (56 additional authors not shown)
Abstract:
In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The S…
▽ More
In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.
△ Less
Submitted 18 March, 2022; v1 submitted 26 November, 2021;
originally announced November 2021.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Belle II Silicon Vertex Detector
Authors:
Gagan B. Mohanty
Abstract:
The Belle II experiment at the SuperKEKB collider in Japan is designed to indirectly probe new physics using approximately 50 times the data recorded by its predecessor. An accurate determination of the decay-point position of subatomic particles such as beauty and charm hadrons as well as a precise measurement of low-momentum charged particles will play a key role in this pursuit. These will be a…
▽ More
The Belle II experiment at the SuperKEKB collider in Japan is designed to indirectly probe new physics using approximately 50 times the data recorded by its predecessor. An accurate determination of the decay-point position of subatomic particles such as beauty and charm hadrons as well as a precise measurement of low-momentum charged particles will play a key role in this pursuit. These will be accomplished by an inner tracking device comprising two layers of pixelated silicon detector and four layers of silicon vertex detector based on double-sided microstrip sensors. We describe herein the design, prototy** and construction efforts of the Belle-II silicon vertex detector.
△ Less
Submitted 6 April, 2016; v1 submitted 19 November, 2015;
originally announced November 2015.
-
Design, fabrication and characterization of the first AC-coupled silicon microstrip sensors in India
Authors:
T. Aziz,
S. R. Chendvankar,
G. B. Mohanty,
M. R. Patil,
K. K. Rao,
Y. R. Rani,
Y. P. P. Rao,
H. Behnamian,
S. Mersi,
M. Naseri
Abstract:
This paper reports the design, fabrication and characterization of single-sided silicon microstrip sensors with integrated biasing resistors and coupling capacitors, produced for the first time in India. We have first developed a prototype sensor on a four-inch wafer. After finding suitable test procedures for characterizing these AC coupled sensors, we have fine-tuned various process parameters i…
▽ More
This paper reports the design, fabrication and characterization of single-sided silicon microstrip sensors with integrated biasing resistors and coupling capacitors, produced for the first time in India. We have first developed a prototype sensor on a four-inch wafer. After finding suitable test procedures for characterizing these AC coupled sensors, we have fine-tuned various process parameters in order to produce sensors with the desired specifications.
△ Less
Submitted 8 May, 2014; v1 submitted 11 February, 2014;
originally announced February 2014.
-
Charm at Belle II - Status and Prospects
Authors:
Gagan B. Mohanty
Abstract:
High-precision flavor physics measurements play a complementary role to the direct searches for new physics by CMS and ATLAS experiments at LHC. Such measurements will be performed with the Belle II detector at the upgraded KEKB accelerator (SuperKEKB) in Japan. The physics potential with emphasis on the charm sector, current status and future prospects of the Belle II experiment are presented in…
▽ More
High-precision flavor physics measurements play a complementary role to the direct searches for new physics by CMS and ATLAS experiments at LHC. Such measurements will be performed with the Belle II detector at the upgraded KEKB accelerator (SuperKEKB) in Japan. The physics potential with emphasis on the charm sector, current status and future prospects of the Belle II experiment are presented in these proceedings.
△ Less
Submitted 16 January, 2014; v1 submitted 21 December, 2013;
originally announced December 2013.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Extracting longitudinal shower development information from crystal calorimetry plus tracking
Authors:
D. N. Brown,
J. Ilic,
G. B. Mohanty
Abstract:
We propose an approach to derive longitudinal shower development information from the longitudinally unsegmented BABAR electromagnetic calorimeter by using tracking information. Our algorithm takes advantage of the good three-dimensional tracking resolution of BABAR, which provides an independent geometric constraint on the shower as measured in the BABAR crystal calorimeter. We show that adding…
▽ More
We propose an approach to derive longitudinal shower development information from the longitudinally unsegmented BABAR electromagnetic calorimeter by using tracking information. Our algorithm takes advantage of the good three-dimensional tracking resolution of BABAR, which provides an independent geometric constraint on the shower as measured in the BABAR crystal calorimeter. We show that adding the derived longitudinal shower development information to standard particle identification algorithms significantly improves the low-momentum separation of pions from electrons and muons. We also verify that the energy dependence of the electromagnetic shower development we measure is consistent with the prediction of a standard electromagnetic shower model.
△ Less
Submitted 11 April, 2008; v1 submitted 12 November, 2007;
originally announced November 2007.
-
New Limits to the IR Background: Bounds on Radiative Neutrino Decay and on VMO Contributions to the Dark Matter Problem
Authors:
S. D. Biller,
J. Buckley,
A. Burdett,
J. Bussons Gordo,
D. A. Carter-Lewis,
D. J. Fegan,
J. Findley,
J. A. Gaidos,
A. M. Hillas,
F. Krennrich,
R. C. Lamb,
R. Lessard,
J. E. McEnery,
G. Mohanty,
J. Quinn,
A. J. Rodgers,
H. J. Rose,
F. Samuelson,
G. Sembroski,
P. Skelton,
T. C. Weekes,
J,
Zweerink
Abstract:
From considering the effect of gamma-gamma interactions on recently observed TeV gamma-ray spectra, improved limits are set to the density of extragalactic infrared (IR) photons which are robust and essentially model-independent. The resulting limits are up to two orders of magnitude more restrictive than direct observations in the 0.025-0.3eV regime. These limits are used to improve constraints…
▽ More
From considering the effect of gamma-gamma interactions on recently observed TeV gamma-ray spectra, improved limits are set to the density of extragalactic infrared (IR) photons which are robust and essentially model-independent. The resulting limits are up to two orders of magnitude more restrictive than direct observations in the 0.025-0.3eV regime. These limits are used to improve constraints on radiative neutrino decay in the mass range above 0.05eV and on Very Massive Objects (VMOs) as providing the dark matter needed to explain galaxy rotation curves.
△ Less
Submitted 18 February, 1998;
originally announced February 1998.