The Double Chooz antineutrino detectors
Authors:
Double Chooz Collaboration,
H. de Kerret,
Y. Abe,
C. Aberle,
T. Abrahão,
J. M. Ahijado,
T. Akiri,
J. M. Alarcón,
J. Alba,
H. Almazan,
J. C. dos Anjos,
S. Appel,
F. Ardellier,
I. Barabanov,
J. C. Barriere,
E. Baussan,
A. Baxter,
I. Bekman,
M. Bergevin,
A. Bernstein,
W. Bertoli,
T. J. C. Bezerra,
L. Bezrukov,
C. Blanco,
N. Bleurvacq
, et al. (226 additional authors not shown)
Abstract:
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in th…
▽ More
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
△ Less
Submitted 13 September, 2022; v1 submitted 31 January, 2022;
originally announced January 2022.
-
Reactor electron antineutrino disappearance in the Double Chooz experiment
Authors:
Y. Abe,
C. Aberle,
J. C. dos Anjos,
J. C. Barriere,
M. Bergevin,
A. Bernstein,
T. J. C. Bezerra,
L. Bezrukhov,
E. Blucher,
N. S. Bowden,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
P. Chimenti,
T. Classen,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (140 additional authors not shown)
Abstract:
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted…
▽ More
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted as evidence of electron antineutrino disappearance. From a rate plus spectral shape analysis we find sin^2 2θ13 = 0.109 \pm 0.030(stat) \pm 0.025(syst). The data exclude the no-oscillation hypothesis at 99.8% CL (2.9σ).
△ Less
Submitted 30 August, 2012; v1 submitted 26 July, 2012;
originally announced July 2012.
-
Development and evaluation of 10-inch Photo-Multiplier Tubes for the Double Chooz experiment
Authors:
T. Matsubara,
T. Haruna,
T. Konno,
Y. Endo,
M. Bongrand,
H. Furuta,
T. Hara,
M. Ishitsuka,
T. Kawasaki,
M. Kuze,
J. Maeda,
Y. Mishina,
Y. Miyamoto,
H. Miyata,
Y. Nagasaka,
Y. Sakamoto,
F. Sato,
A. Shigemori,
F. Suekane,
T. Sumiyoshi,
H. Tabata,
N. Tamura
Abstract:
The goal of Double Chooz experiment is a precise measurement of the last unknown mixing angle theta_13 using two identical detectors placed at far and near sites from Chooz reactor cores. The detector is optimized for reactor-neutrino detection using specially developed 10-inch PMTs. We developed two types of measurement systems and evaluated 400 PMTs before the installation. Those PMTs fulfill ou…
▽ More
The goal of Double Chooz experiment is a precise measurement of the last unknown mixing angle theta_13 using two identical detectors placed at far and near sites from Chooz reactor cores. The detector is optimized for reactor-neutrino detection using specially developed 10-inch PMTs. We developed two types of measurement systems and evaluated 400 PMTs before the installation. Those PMTs fulfill our requirements, and a half of those have been installed to the far detector in 2009. The character and performance data of the PMTs are stored in a database and will be referenced in analysis and MC simulation.
△ Less
Submitted 5 April, 2011;
originally announced April 2011.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Development of Multi-Pixel Photon Counters
Authors:
M. Yokoyama,
T. Nobuhara,
M. Taguchi,
T. Nakaya,
T. Murakami,
T. Nakadaira,
K. Yoshimura,
K. Kawagoe,
Y. Tamura,
T. Iijima,
Y. Mazuka,
K. Miyabayashi,
S. Iba,
H. Miyata,
T. Takeshita
Abstract:
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise r…
▽ More
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise rate less than 1 MHz with 1 p.e. threshold, and cross-talk probability of less than 30% at room temperature. The photon detection efficiency for green light is twice or more that of the photomultiplier tubes. It is found that the basic performance of the MPPC is satisfactory for use in real experiments.
△ Less
Submitted 29 May, 2006;
originally announced May 2006.