Performance of the LHCb RICH detectors during LHC Run 2
Authors:
R. Calabrese,
M. Fiorini,
E. Luppi,
L. Minzoni,
I. Slazyk,
L. Tomassetti,
M. Bartolini,
R. Cardinale,
F. Fontanelli,
A. Petrolini,
A. Pistone,
M. Calvi,
C. Matteuzzi,
A. Lupato,
G. Simi,
M. Kucharczyk,
B. Malecki,
M. Witek,
S. Benson,
M. Blago,
G. Cavallero,
A. Contu,
C. D'Ambrosio,
C. Frei,
T. Gys
, et al. (57 additional authors not shown)
Abstract:
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
△ Less
Submitted 26 May, 2022;
originally announced May 2022.
Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes
Authors:
M. Andreotti,
S. Capelli,
G. Cavallero,
S. Chiozzi,
A. Cotta Ramusino,
C. D'Ambrosio,
M. Fiorini,
E. Franzoso,
C. Frei,
S. Gallorini,
S. Gambetta,
C. Giugliano,
C. Gotti,
T. Gys,
F. Keizer,
M. Maino,
B. Malecki,
L. Minzoni,
S. Mitchell,
I. Neri,
A. Petrolini,
D. Piedigrossi,
G. Robertson,
A. Sergi,
G. Simi
, et al. (4 additional authors not shown)
Abstract:
Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform…
▽ More
Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.
△ Less
Submitted 23 November, 2021; v1 submitted 2 October, 2021;
originally announced October 2021.