A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
The Power Board of the KM3NeT Digital Optical Module: design, upgrade, and production
Authors:
S. Aiello,
A. Albert,
S. Alves Garre,
Z. Aly,
A. Ambrosone,
F. Ameli,
M. Andre,
E. Androutsou,
M. Anguita,
L. Aphecetche,
M. Ardid,
S. Ardid,
H. Atmani,
J. Aublin,
F. Badaracco,
L. Bailly-Salins,
Z. Bardacova,
B. Baret,
A. Bariego Quintana,
S. Basegmez du Pree,
Y. Becherini,
M. Bendahman,
F. Benfenati,
M. Benhassi,
D. M. Benoit
, et al. (259 additional authors not shown)
Abstract:
The KM3NeT Collaboration is building an underwater neutrino observatory at the bottom of the Mediterranean Sea consisting of two neutrino telescopes, both composed of a three-dimensional array of light detectors, known as digital optical modules. Each digital optical module contains a set of 31 three inch photomultiplier tubes distributed over the surface of a 0.44 m diameter pressure-resistant gl…
▽ More
The KM3NeT Collaboration is building an underwater neutrino observatory at the bottom of the Mediterranean Sea consisting of two neutrino telescopes, both composed of a three-dimensional array of light detectors, known as digital optical modules. Each digital optical module contains a set of 31 three inch photomultiplier tubes distributed over the surface of a 0.44 m diameter pressure-resistant glass sphere. The module includes also calibration instruments and electronics for power, readout and data acquisition. The power board was developed to supply power to all the elements of the digital optical module. The design of the power board began in 2013, and several prototypes were produced and tested. After an exhaustive validation process in various laboratories within the KM3NeT Collaboration, a mass production batch began, resulting in the construction of over 1200 power boards so far. These boards were integrated in the digital optical modules that have already been produced and deployed, 828 until October 2023. In 2017, an upgrade of the power board, to increase reliability and efficiency, was initiated. After the validation of a pre-production series, a production batch of 800 upgraded boards is currently underway. This paper describes the design, architecture, upgrade, validation, and production of the power board, including the reliability studies and tests conducted to ensure the safe operation at the bottom of the Mediterranean Sea throughout the observatory's lifespan
△ Less
Submitted 24 November, 2023;
originally announced November 2023.
-
Characterization of LAPPD timing at CERN PS testbeam
Authors:
Deb Sankar Bhattacharya,
Andrea Bressan,
Chandradoy Chatterjee,
Silvia Dalla Torre,
Mauro Gregori,
Alexander Kiselev,
Stefano Levorato,
Anna Martin,
Saverio Minutoli,
Mikhail Osipenko,
Richa Rai,
Marco Ripani,
Fulvio Tessarotto,
Triloki Triloki
Abstract:
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns risetime followed by a slightly longer falltime and their amplitude reaches a few dozen…
▽ More
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns risetime followed by a slightly longer falltime and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. The measured time resolution for single photoelectrons is about 80 ps r.m.s.
△ Less
Submitted 26 September, 2023;
originally announced September 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Upgrade of compact neutron spectrometer for high flux environments
Authors:
M. Osipenko,
A. Bellucci,
V. Ceriale,
D. Corsini,
G. Gariano,
F. Gatti,
M. Girolami,
S. Minutoli,
F. Panza,
M. Pillon,
M. Ripani,
D. M. Trucchi
Abstract:
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge obs…
▽ More
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge observed in the previous prototypes. New passive preamplification of signal at detector side was implemented to improve the resolution. This preamplification is based on RF transformer not sensitive to high neutron flux. Compact mechanical design allowed to reduce detector size to a tube of 1 cm diameter and 13 cm long. The spectrometer was tested in thermal column of TRIGA reactor and at DD neutron generator. The test results indicate an energy resolution of 72 keV (RMS) and coincidence timing resolution of 68 ps (RMS). The measured data are in agreement with Geant4 simulations except for larger energy loss tail presumably related to imperfections of metal contacts and glue expansion.
△ Less
Submitted 18 July, 2017;
originally announced July 2017.
-
A Radial Time Projection Chamber for $α$ detection in CLAS at JLab
Authors:
R. Dupré,
S. Stepanyan,
M. Hattawy,
N. Baltzell,
K. Hafidi,
M. Battaglieri,
S. Bueltmann,
A. Celentano,
R. De Vita,
A. El Alaoui,
L. El Fassi,
H. Fenker,
K. Kosheleva,
S. Kuhn,
P. Musico,
S. Minutoli,
M. Oliver,
Y. Perrin,
B. Torayev,
E. Voutier
Abstract:
A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS)…
▽ More
A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS) cannot track the low energy $α$ particles. In 2009, we carried out measurements using the CLAS spectrometer supplemented by the RTPC positioned directly around a gaseous $^4$He target, allowing a detection threshold as low as 12$\sim$MeV for $^4$He. This article discusses the design, principle of operation, calibration methods and the performances of this RTPC.
△ Less
Submitted 30 January, 2018; v1 submitted 30 June, 2017;
originally announced June 2017.
-
Diamond Detectors for the TOTEM Timing Upgrade
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
P. Broulím,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (58 additional authors not shown)
Abstract:
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with o…
▽ More
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (54 additional authors not shown)
Abstract:
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport…
▽ More
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.
△ Less
Submitted 2 June, 2014;
originally announced June 2014.
-
Performance of the TOTEM Detectors at the LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
R. Cecchi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (57 additional authors not shown)
Abstract:
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi…
▽ More
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.
-
Comparison of Fast Amplifiers for Diamond Detectors
Authors:
M. Osipenko,
S. Minutoli,
P. Musico,
M. Ripani,
B. Caiffi,
A. Balbi,
G. Ottonello,
S. Argirò,
S. Beolè,
N. Amapane,
M. Masera,
G. Mila
Abstract:
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a nu…
▽ More
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a number of commercial amplifiers designed for diamond detector readout to identify the best solution for a particular application. This application required a deposited energy threshold below 100 keV and timing resolution of the order of 200 ps at 200 keV. None of tested amplifiers satisfies these requirements. The best solution to such application found to be the Cividec C6 amplifier, which allows 100 keV minimal threshold, but its coincidence timing resolution at 200 keV is as large as 1.2 ns.
△ Less
Submitted 3 October, 2013;
originally announced October 2013.