-
High Voltage Determination and Stabilization for Collinear Laser Spectroscopy Applications
Authors:
Kristian König,
Finn Köhler,
Julian Palmes,
Henrik Badura,
Adam Dockery,
Kei Minamisono,
Johann Meisner,
Patrick Müller,
Wilfried Nörtershäuser,
Stephan Passon
Abstract:
Fast beam collinear laser spectroscopy is the established method to investigate nuclear ground state properties such as the spin, the electromagnetic moments, and the charge radius of exotic nuclei. These are extracted with high precision from atomic observables, i.e., the hyperfine splitting and its the isotope shift, which becomes possible due to a large reduction of the Doppler broadening by co…
▽ More
Fast beam collinear laser spectroscopy is the established method to investigate nuclear ground state properties such as the spin, the electromagnetic moments, and the charge radius of exotic nuclei. These are extracted with high precision from atomic observables, i.e., the hyperfine splitting and its the isotope shift, which becomes possible due to a large reduction of the Doppler broadening by compressing the velocity width of the ion beam through electrostatic acceleration. With the advancement of the experimental methods and applied devices, e.g., to measure and stabilize the laser frequency, the acceleration potential became the dominant systematic uncertainty contribution. To overcome this, we present a custom-built high-voltage divider, which was developed and tested at the German metrology institute (PTB), and a feedback loop that enabled collinear laser spectroscopy to be performed at a 100-kHz level. Furthermore, we describe the impact of field penetration into the laser-ion-interaction region. This strongly affects the determined isotope shifts and hyperfine splittings, if Doppler tuning is applied, i.e., the ion beam energy is altered instead of scanning the laser frequency. Using different laser frequencies that were referenced to a frequency comb, the field penetration was extracted laser spectroscopically. This allowed us to define an effective scanning potential to still apply the faster and easier Doppler tuning without introducing systematic deviations.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
Isotope shift factors with quantum electrodynamics effects for many-electron systems: A study of the nuclear charge radius of $^{26m}$Al
Authors:
Leonid V. Skripnikov,
Sergey D. Prosnyak,
Aleksei V. Malyshev,
Michail Athanasakis-Kaklamanakis,
Alex Jose Brinson,
Kei Minamisono,
Fabian C. Pastrana Cruz,
Jordan Ray Reilly,
Brooke J. Rickey,
Ronald. F. Garcia Ruiz
Abstract:
A method for calculating the field shift contribution to isotope shifts in many-electron atoms, incorporating quantum electrodynamics (QED) effects, is introduced. We also implement the model QED approach to incorporate QED contribution to the nuclear recoil effect at the high-order correlation effects treatment level. The proposed computational scheme is used to revise the value of the root-mean-…
▽ More
A method for calculating the field shift contribution to isotope shifts in many-electron atoms, incorporating quantum electrodynamics (QED) effects, is introduced. We also implement the model QED approach to incorporate QED contribution to the nuclear recoil effect at the high-order correlation effects treatment level. The proposed computational scheme is used to revise the value of the root-mean-square (rms) nuclear charge radius of the isomer of aluminium-26, $^{26m}$Al. This radius is important for the global analysis of the $V_{ud}$ element of the Cabibbo-Kobayashi-Maskawa matrix. The difference in mean-square nuclear charge radii of $^{27}$Al and $^{26m}$Al, obtained by combining the calculated atomic factors with recently measured isotope shift (IS) of the $3s^23p~^2P_{3/2} \to 3s^24s~^2S_{1/2}$ transition in Al, is $0.443(44)(19)~{\rm fm}^2$, where the first and second uncertainties are experimental and theoretical ones, respectively. The latter is reduced by a factor of 4 with respect to the previous study. Using this value and the known value of the rms charge radius of $^{27}$Al, the resultant value $R_c(^{26m}$Al) = 3.132(10)~fm is obtained. With the improved accuracy of the calculated IS factors the error in $R_c(^{26m}$Al) is now dominated by the experimental uncertainty. Similar revision of rms charge radii is made for the $^{28}$Al, $^{29}$Al, $^{30}$Al, $^{31}$Al and $^{32}$Al isotopes using existing IS measurements. Additionally, atomic factors are computed for the {$3s^23p~^2P_{3/2} \to 3s^24s~^2S_{1/2}$}, {$3s^23p~^2P_{1/2} \to 3s^25s~^2S_{1/2}$} and {$3s^23p~^2P_{3/2} \to 3s^25s~^2S_{1/2}$} transitions in Al, which can be used in future experimental studies.
△ Less
Submitted 20 April, 2024;
originally announced April 2024.
-
Kinetic-beam-energy determination via collinear laser spectroscopy
Authors:
Kristian König,
Kei Minamisono,
Jeremy Lantis,
Skyy Pineda,
Robert Powel
Abstract:
An approach to determine the kinetic beam energy at the $10^{-5}$ level is presented, which corresponds to an improvement by more than one order of magnitude compared to conventional methods. Particularly, collinear fluorescence and resonance ionization spectroscopy measurements on rare isotope beams, where the beam energy is a major contribution to the uncertainty, can benefit from this method. T…
▽ More
An approach to determine the kinetic beam energy at the $10^{-5}$ level is presented, which corresponds to an improvement by more than one order of magnitude compared to conventional methods. Particularly, collinear fluorescence and resonance ionization spectroscopy measurements on rare isotope beams, where the beam energy is a major contribution to the uncertainty, can benefit from this method. The approach is based on collinear spectroscopy and requires no special equipment besides a wavelength meter, which is commonly available. Its advent is demonstrated in a proof-of-principle experiment on a Ni beam. In preparation for the energy measurement, the rest-frame transition frequencies of the $3d^9 4s\;^3\mathrm{D}_3 \rightarrow 3d^9 4p\;^3\mathrm{P}_2$ transitions in neutral nickel isotopes have been identified to be $ν_0(^{58}\mathrm{Ni})=850\,343\,678\,(20)$ MHz and $ν_0(^{60}\mathrm{Ni})=850\,344\,183\,(20)$ MHz.
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
A $4π$ Fluorescence Detection Region for Collinear Laser Spectroscopy
Authors:
Bernhard Maaß,
Kristian König,
Jörg Krämer,
Andrew J. Miller,
Kei Minamisono,
Wilfried Nörtershäuser,
Felix Sommer
Abstract:
We report on a novel detection system for collinear laser spectroscopy which provides an almost $4π$ solid angle for fluorescence photon detection by employing curved surface mirrors. Additional parabolic angular filters offer passive stray light suppression and can be configured to match the experimental conditions. The mirror surfaces have an excellent reflectivity over a broad band of wavelengt…
▽ More
We report on a novel detection system for collinear laser spectroscopy which provides an almost $4π$ solid angle for fluorescence photon detection by employing curved surface mirrors. Additional parabolic angular filters offer passive stray light suppression and can be configured to match the experimental conditions. The mirror surfaces have an excellent reflectivity over a broad band of wavelengths in the optical spectrum and can be substituted to expand the wavelength acceptance range even further. Experiments with this system were performed at two collinear laser spectroscopy setups, including the laser spectroscopic investigation of $^{36}$Ca using rates of 25/s at NSCL, MSU.
△ Less
Submitted 6 July, 2020;
originally announced July 2020.