-
Super-FRS GEM-TPC Prototype Development Based on n-Xyter Asic for the FAIR Facility
Authors:
F. Garcia,
R. Turpeinen,
R. Lauhakangas,
E. Tuominen,
R. Janik,
P. Strmen,
M. Pikna,
B. Sitar,
B. Voss,
J. Kunkel,
V. Kleipa,
A. Prochazka,
J. Hoffmann,
I. Rusanov,
N. Kurz,
S. Minami
Abstract:
The FAIR facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver…
▽ More
The FAIR facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV /u as created in the production process, the low energy branch aims to use beams in the range of 0-150 MeV/u whereas the ring branch will cool and store beams in the NESR ring. The main tasks for the Super-FRS beam diagnostics chambers will be for the set up and adjustment of the separator as well as to provide tracking and event-by-event particle identification. The Helsinki Institute of Physics, the Comenius University, and the Detector Laboratory and Experimental electronics at GSI are in a joint R&D phase of a GEM-TPC detector which could satisfy the requirements of such diagnostics and tracking chambers in terms of tracking efficiency, space resolution, count rate capability and momenta resolution. The current status of the first prototype and the preliminary results from the test beam campaign S417 using the n-Xyter chips mounted on GEMEX cards will be shown.
△ Less
Submitted 16 December, 2016;
originally announced January 2017.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI - a Development for the Super-FRS at FAIR
Authors:
F. Garcia,
R. Turpeinen,
R. Lauhakangas,
E. Tuominen,
J. Heino,
J. Äystö,
T. Grahn,
S. Rinta-Antilla,
A. Jokinen,
R. Janik,
P. Strmen,
M. Pikna,
B. Sitar,
B. Voss,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
I. Kaufeld,
C. Caesar,
C. Simon,
M. kìs,
A. Prochazka,
C. Nociforo,
S. Pietri
, et al. (8 additional authors not shown)
Abstract:
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.
-
A Large-Scale FPGA-Based Trigger and Dead-Time Free DAQ System for the Kaos Spectrometer at MAMI
Authors:
P. Achenbach,
C. Ayerbe Gayoso,
J. C. Bernauer,
R. Böhm,
D. Bosnar,
L. Debenjak,
M. O. Distler,
A. Esser,
I. Friščić,
M. Gómez Rodríguez de la Paz,
J. Hoffmann,
M. Makek,
H. Merkel,
S. Minami,
U. Müller,
L. Nungesser,
W. Ott,
J. Pochodzalla,
M. Potokar,
I. Rusanov,
T. R. Saito,
S. Sánchez Majos,
B. S. Schlimme,
S. Širca,
S. Voltz
, et al. (2 additional authors not shown)
Abstract:
The Kaos spectrometer is maintained by the A1 collaboration at the Mainz Microtron MAMI with a focus on the study of (e,e'K^+) coincidence reactions. For its electron-arm two vertical planes of fiber arrays, each comprising approximately 10 000 fibers, are operated close to zero degree scattering angle and in close proximity to the electron beam. A nearly dead-time free DAQ system to acquire timin…
▽ More
The Kaos spectrometer is maintained by the A1 collaboration at the Mainz Microtron MAMI with a focus on the study of (e,e'K^+) coincidence reactions. For its electron-arm two vertical planes of fiber arrays, each comprising approximately 10 000 fibers, are operated close to zero degree scattering angle and in close proximity to the electron beam. A nearly dead-time free DAQ system to acquire timing and tracking information has been installed for this spectrometer arm. The signals of 144 multi-anode photomultipliers are collected by 96-channel front-end boards, digitized by double-threshold discriminators and the signal time is picked up by state-of-the-art F1 time-to-digital converter chips. In order to minimize background rates a sophisticated trigger logic was implemented in newly developed Vuprom modules. The trigger performs noise suppression, signal cluster finding, particle tracking, and coincidence timing, and can be expanded for kinematical matching (e'K^+) coincidences. The full system was designed to process more than 4 000 read-out channels and to cope with the high electron flux in the spectrometer and the high count rate requirement of the detectors. It was successfully in-beam tested at MAMI in 2009.
△ Less
Submitted 1 May, 2011;
originally announced May 2011.