LANSCE-PSR Short-Pulse Upgrade for Improved Dark Sector Particle Searches with the Coherent Captain Mills Experiment
Authors:
R. G. Van de Water,
S. G. Biedron,
E. -C. Huang,
A. J. Hurd,
W. C. Louis,
S. V. Milton,
N. A. Moody,
P. deNiverville,
C. E. Taylor,
R. T. Thornton,
M. Fazio,
S. I. Sosa,
T. J. Schaub,
J. W. Lewellen
Abstract:
Proton beam dumps are prolific sources of charged and neutral pions, enabling a powerful technique to search for dark matter, axions, sterile neutrinos, tests of short baseline anomalies, and precision measurements of coherent nucleus scattering neutrinos (CEvNS). The Lujan neutron elastic scattering center at the Los Alamos Neutron Science Center (LANSCE) consists of an 800-MeV, short-pulse, 100-…
▽ More
Proton beam dumps are prolific sources of charged and neutral pions, enabling a powerful technique to search for dark matter, axions, sterile neutrinos, tests of short baseline anomalies, and precision measurements of coherent nucleus scattering neutrinos (CEvNS). The Lujan neutron elastic scattering center at the Los Alamos Neutron Science Center (LANSCE) consists of an 800-MeV, short-pulse, 100-kW proton and spallation neutron source where such searches are ongoing with the Coherent CAPTAIN Mills (CCM) 10-ton, liquid argon detector. The employment of fast timing coincidence of the beam with the detector is used to identify signals and reject background. The current beam time width is 300 ns with an intensity of $3.1 \times 10^{13}$ protons per pulse at 20 Hz. With upgrades to the Proton Storage Ring (PSR), the beam time width may be compressed to 30 ns with minimal intensity loss, allowing an increase in the signal to background (S/B) of more than 100 and an increase in the sensitivity for dark matter and sterile neutrino searches of an order of magnitude. This can be achieved with PSR accelerator upgrades on a time scale of a few years and at a modest cost.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
Neural Network Model Of The PXIE RFQ Cooling System and Resonant Frequency Response
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
D. Bowring,
B. E. Chase,
J. P. Edelen,
J. Steimel
Abstract:
As part of the PIP-II Injector Experiment (PXIE) accelerator, a four-vane radio frequency quadrupole (RFQ) accelerates a 30-keV, 1-mA to 10-mA H- ion beam to 2.1 MeV. It is designed to operate at a frequency of 162.5 MHz with arbitrary duty factor, including continuous wave (CW) mode. The resonant frequency is controlled solely by a water-cooling system. We present an initial neural network model…
▽ More
As part of the PIP-II Injector Experiment (PXIE) accelerator, a four-vane radio frequency quadrupole (RFQ) accelerates a 30-keV, 1-mA to 10-mA H- ion beam to 2.1 MeV. It is designed to operate at a frequency of 162.5 MHz with arbitrary duty factor, including continuous wave (CW) mode. The resonant frequency is controlled solely by a water-cooling system. We present an initial neural network model of the RFQ frequency response to changes in the cooling system and RF power conditions during pulsed operation. A neural network model will be used in a model predictive control scheme to regulate the resonant frequency of the RFQ.
△ Less
Submitted 21 December, 2016;
originally announced December 2016.
-
First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
J. P. Edelen
Abstract:
At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is espec…
▽ More
At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.
-
Resonant Frequency Control For the PIP-II Injector Test RFQ: Control Framework and Initial Results
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
D. Bowring,
B. E. Chase,
J. P. Edelen,
D. Nicklaus,
J. Steimel
Abstract:
For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over th…
▽ More
For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over the detuning, minimal manual intervention, and fast trip recovery is desired. In addition, having active control over both the walls and vanes provides a wider tuning range. For this, we intend to use model predictive control (MPC). To facilitate these objectives, we developed a dedicated control framework that handles higher-level system decisions as well as executes control calculations. It is written in Python in a modular fashion for easy adjustments, readability, and portability. Here we describe the framework and present the first control results for the PI-Test RFQ under pulsed and CW operation.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.
-
A temporal model for quasi-phase matching in high-order harmonic generation
Authors:
Y. Tao,
S. J. Goh,
H. M. J. Bastiaens,
P. J. M. van der Slot,
S. G. Biedron,
S. V. Milton,
K. -J. Klaus
Abstract:
We present a model for quasi-phase matching (QPM) in high-order harmonic generation (HHG). Using a one-dimensional description, we analyze the time-dependent, ultrafast wave-vector balance to calculate the on-axis harmonic output versus time, from which we obtain the output pulse energy. Considering, as an example, periodically patterned argon gas, as may be provided with a grid in a cluster jet,…
▽ More
We present a model for quasi-phase matching (QPM) in high-order harmonic generation (HHG). Using a one-dimensional description, we analyze the time-dependent, ultrafast wave-vector balance to calculate the on-axis harmonic output versus time, from which we obtain the output pulse energy. Considering, as an example, periodically patterned argon gas, as may be provided with a grid in a cluster jet, we calculate the harmonic output during different time intervals within the drive laser pulse duration. We find that identifying a suitable single spatial period is not straightforward due to the complex and ultrafast plasma dynamics that underlies HHG at increased intensities. The maximum on-axis harmonic pulse energy is obtained when choosing the QPM period to phase match HHG at the leading edge of the drive laser pulse.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
Cluster size dependence of high-order harmonic generation
Authors:
Y. Tao,
R. Hagmeijers,
H. M. J. Bastiaens,
S. J. Goh,
P. J. M. van der Slot,
S. G. Biedron,
S. V. Milton,
K. -J. Boller
Abstract:
We investigate high-order harmonic generation (HHG) from noble gas clusters in a supersonic gas jet. To identify the contribution of harmonic generation from clusters versus that from gas monomers, we measure the high-order harmonic output over a broad range of the total atomic number density in the jet (from 3*10^16 cm^{-3} to 3x10^18 cm{-3}) at two different reservoir temperatures (303 K and 363…
▽ More
We investigate high-order harmonic generation (HHG) from noble gas clusters in a supersonic gas jet. To identify the contribution of harmonic generation from clusters versus that from gas monomers, we measure the high-order harmonic output over a broad range of the total atomic number density in the jet (from 3*10^16 cm^{-3} to 3x10^18 cm{-3}) at two different reservoir temperatures (303 K and 363 K). For the firrst time in the evaluation of the harmonic yield in such measurements, the variation of the liquid mass fraction, g, versus pressure and temperature is taken into consideration, which we determine, reliably and consistently, to be below 20% within our range of experimental parameters. By comparing the measured harmonic yield from a thin jet with the calculated corresponding yield from monomers alone, we find an increased emission of the harmonics when the average cluster size is less than 3000. Using g, under the assumption that the emission from monomers and clusters add up coherently, we calculate the ratio of the average single-atom response of an atom within a cluster to that of a monomer and find an enhancement of around 10 for very small average cluster size (~200). We do not find any dependence of the cut-off frequency on the composition of the cluster jet. This implies that HHG in clusters is based on electrons that return to their parent ions and not to neighbouring ions in the cluster. To fully employ the enhanced average single-atom response found for small average cluster sizes (~200), the nozzle producing the cluster jet must provide a large liquid mass fraction at these small cluster sizes for increasing the harmonic yield. Moreover, cluster jets may allow for quasi-phase matching, as the higher mass of clusters allows for a higher density contrast in spatially structuring the nonlinear medium.
△ Less
Submitted 2 May, 2017; v1 submitted 29 November, 2016;
originally announced November 2016.
-
Neural Networks for Modeling and Control of Particle Accelerators
Authors:
A. L. Edelen,
S. G. Biedron,
B. E. Chase,
D. Edstrom,
S. V. Milton,
P. Stabile
Abstract:
We describe some of the challenges of particle accelerator control, highlight recent advances in neural network techniques, discuss some promising avenues for incorporating neural networks into particle accelerator control systems, and describe a neural network-based control system that is being developed for resonance control of an RF electron gun at the Fermilab Accelerator Science and Technolog…
▽ More
We describe some of the challenges of particle accelerator control, highlight recent advances in neural network techniques, discuss some promising avenues for incorporating neural networks into particle accelerator control systems, and describe a neural network-based control system that is being developed for resonance control of an RF electron gun at the Fermilab Accelerator Science and Technology (FAST) facility, including initial experimental results from a benchmark controller.
△ Less
Submitted 19 October, 2016;
originally announced October 2016.
-
Initial experimental results of a machine learning-based temperature control system for an RF gun
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
B. E. Chase,
D. J. Crawford,
N. Eddy,
D. Edstrom Jr.,
E. R. Harms,
J. Ruan,
J. K. Santucci,
P. Stabile
Abstract:
Colorado State University (CSU) and Fermi National Accelerator Laboratory (Fermilab) have been develo** a control system to regulate the resonant frequency of an RF electron gun. As part of this effort, we present initial test results for a benchmark temperature controller that combines a machine learning-based model and a predictive control algorithm. This is part of an on-going effort to devel…
▽ More
Colorado State University (CSU) and Fermi National Accelerator Laboratory (Fermilab) have been develo** a control system to regulate the resonant frequency of an RF electron gun. As part of this effort, we present initial test results for a benchmark temperature controller that combines a machine learning-based model and a predictive control algorithm. This is part of an on-going effort to develop adaptive, machine learning-based tools specifically to address control challenges found in particle accelerator systems.
△ Less
Submitted 5 November, 2015;
originally announced November 2015.
-
Single-shot fluctuations in waveguided high-harmonic generation
Authors:
S. J. Goh,
Y. Tao,
P. J. M. van der Slot,
H. J. M. Bastiaens,
J. Herek,
S. G. Biedron,
M. B. Danailov,
S. V. Milton,
K. -J. Boller
Abstract:
For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic output energy, fluctuations of the direction of the emission (pointing instabilities), and fluctuat…
▽ More
For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic output energy, fluctuations of the direction of the emission (pointing instabilities), and fluctuations of the beam divergence and shape that reduce the spatial coherence. We present the first single-shot measurements of waveguided high-harmonic generation in a waveguided (capillary-based) geometry. Using a capillary waveguide filled with Argon gas as the nonlinear medium, we provide the first characterization of shot-to-shot fluctuations of the pulse energy, of the divergence and of the beam pointing. We record the strength of these fluctuations vs. two basic input parameters, which are the drive laser pulse energy and the gas pressure in the capillary waveguide. In correlation measurements between single-shot drive laser beam profiles and single-shot high-harmonic beam profiles we prove the absence of drive laser beam-pointing-induced fluctuations in the high-harmonic output. We attribute the main source of high-harmonic fluctuations to ionization-induced nonlinear mode mixing during propagation of the drive laser pulse inside the capillary waveguide.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Pathway to a Compact SASE FEL Device
Authors:
G. Dattoli,
E. Di Palma,
V. Petrillo,
J. V. Rau,
E. Sabia,
I. Spassovsky,
S. G. Biedron,
J. Einstein,
S. V. Milton
Abstract:
Newly developed high peak power lasers have opened the possibilities of driving coherent light sources operating with laser plasma accelerated beams and wave undulators. We speculate on the combination of these two concepts and show that the merging of the underlying technologies could lead to new and interesting possibilities to achieve truly compact, coherent radiator devices.
Newly developed high peak power lasers have opened the possibilities of driving coherent light sources operating with laser plasma accelerated beams and wave undulators. We speculate on the combination of these two concepts and show that the merging of the underlying technologies could lead to new and interesting possibilities to achieve truly compact, coherent radiator devices.
△ Less
Submitted 29 May, 2015;
originally announced May 2015.