-
Modeling when and how physics PhD students search for a research group: the role of interests and prior research experiences in timely group integration
Authors:
Mike Verostek,
Casey W. Miller,
Benjamin M. Zwickl
Abstract:
Studying the factors that influence the quality of physics PhD students' doctoral experiences, especially those that motivate them to stay or leave their programs, is critical for providing them with more holistic and equitable support. Prior literature on doctoral attrition has found that students with clear research interests who establish an advisor-advisee relationship early in their graduate…
▽ More
Studying the factors that influence the quality of physics PhD students' doctoral experiences, especially those that motivate them to stay or leave their programs, is critical for providing them with more holistic and equitable support. Prior literature on doctoral attrition has found that students with clear research interests who establish an advisor-advisee relationship early in their graduate careers are most likely to persist. However, these trends have not been investigated in the context of physics, and the underlying reasons for why these characteristics are associated with leaving remain unstudied. Using semi-structured interviews with 40 first and second year physics PhD students, we construct a model describing the characteristic pathways that physics PhD students take while evaluating interest congruence of prospective research groups. We show how access to undergraduate research and other formative experiences helped some students narrow their interests and look for research groups before arriving to graduate school. In turn, these students reported fewer difficulties finding a group than students whose search for an advisor took place during the first year of their PhD. Lastly, we identify two characteristic types of students at a higher risk of leaving their programs: students who enter graduate school with broad interests and struggle to find a group, and students who join a research group early based on research interest alone and subsequently encounter issues with a negative mentoring relationship. This work serves as a major step toward creating a comprehensive model of how PhD students find a research group, and opens the door for future work to investigate how factors such as group culture and working environment impact the search process.
△ Less
Submitted 21 April, 2024; v1 submitted 17 April, 2024;
originally announced April 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The Design and Construction of the Chips Water Cherenkov Neutrino Detector
Authors:
B. Alonso Rancurel,
N. Angelides,
G. Augustoni,
S. Bash,
B. Bergmann,
N. Bertschinger,
P. Bizouard,
M. Campbell,
S. Cao,
T. J. Carroll,
R. Castellan,
E. Catano-Mur,
J. P. Cesar,
J. A. B. Coelho,
P. Dills,
T. Dodwell,
J. Edmondson,
D. van Eijk,
Q. Fetterly,
Z. Garbal,
S. Germani,
T. Gilpin,
A. Giraudo,
A. Habig,
D. Hanuska
, et al. (42 additional authors not shown)
Abstract:
CHIPS (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the CHIPS detector along with de…
▽ More
CHIPS (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the CHIPS detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
First measurements of radon-220 diffusion in mice tumors, towards treatment planning in diffusing alpha-emitters radiation therapy
Authors:
Guy Heger,
Mirta Dumančić,
Ishai Luz,
Maayan Vatarescu,
Noam Weizman,
Brian W. Miller,
Tomer Cooks,
Lior Arazi
Abstract:
Alpha-DaRT is a new method for treating solid tumors with alpha particles, relying on the release of the alpha-emitting daughter atoms of radium-224 from sources inserted into the tumor. The most important model parameters for Alpha-DaRT dosimetry are the diffusion lengths of radon-220 and lead-212, and their estimation is essential for treatment planning. The aim of this work is to provide first…
▽ More
Alpha-DaRT is a new method for treating solid tumors with alpha particles, relying on the release of the alpha-emitting daughter atoms of radium-224 from sources inserted into the tumor. The most important model parameters for Alpha-DaRT dosimetry are the diffusion lengths of radon-220 and lead-212, and their estimation is essential for treatment planning. The aim of this work is to provide first experimental estimates for the diffusion length of radon-220. The diffusion length of radon-220 was estimated from autoradiography measurements of histological sections taken from 24 mice-borne subcutaneous tumors of five different types. Experiments were done in two sets: fourteen in-vivo tumors, where during the treatment the tumors were still carried by the mice with active blood supply, and ten ex-vivo tumors, where the tumors were excised before source insertion and kept in a medium at 37 degrees C with the source inside. The measured diffusion lengths of radon-220 lie in the range 0.25-0.6 mm, with no significant difference between the average values measured in in-vivo and ex-vivo tumors: 0.40 $\pm$ 0.08 mm for in-vivo vs. 0.39 $\pm$ 0.07 mm for ex-vivo. However, in-vivo tumors display an enhanced spread of activity 2-3 mm away from the source. This effect is not explained by the current model and is much less pronounced in ex-vivo tumors. The average measured radon-220 diffusion lengths in both in-vivo and ex-vivo tumors lie close to the upper limit of the previously estimated range of 0.2-0.4 mm. The observation that close to the source there is no apparent difference between in-vivo and ex-vivo tumors, and the good agreement with the theoretical model in this region suggest that the spread of radon-220 is predominantly diffusive in this region. The departure from the model prediction in in-vivo tumors at large radial distances may hint at potential vascular contribution.
△ Less
Submitted 21 January, 2024; v1 submitted 16 January, 2024;
originally announced January 2024.
-
Surface charge induced $sp^3$-$sp^2$ transformation: new energy optimization universal mechanism of (4x4) reconstruction of stoichiometric GaN(0001) surface
Authors:
Paweł Strak,
Wolfram Miller,
Stanisław Krukowski
Abstract:
Ab initio calculations were applied to large size slabs simulations for determination of the properties of the principal structures of the stoichiometric GaN(0001) surface. The results are different from published previously: stoichiometric GaN(0001) surface structure is characterized by mixed structure in which 3/8 top layer Ga atoms remain in standard position with $sp^3$ hybridized bonding whil…
▽ More
Ab initio calculations were applied to large size slabs simulations for determination of the properties of the principal structures of the stoichiometric GaN(0001) surface. The results are different from published previously: stoichiometric GaN(0001) surface structure is characterized by mixed structure in which 3/8 top layer Ga atoms remain in standard position with $sp^3$ hybridized bonding while the remaining 5/8 top layer Ga atoms is located in plane of N atoms with $sp^2$ hybridized bonding. This involves charge transfer to the previous one, entailing energy optimization, therefore Ga-s and Ga-p energy difference is driving force for the transition. In large size surfaces Ga atoms create (4 x 4) reconstruction which is additionally stabilized by strain optimization. Heavy do** in the bulk changes $sp^3$ to $sp^2$ ratio thus confirming the charge transfer mechanism of the reconstruction. The charge transfer energy optimization is universal for all surfaces terminated by $sp^3$ bonded atoms.
△ Less
Submitted 22 January, 2024; v1 submitted 12 January, 2024;
originally announced January 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Physics PhD student perspectives on the importance and difficulty of finding a research group
Authors:
Mike Verostek,
Casey W. Miller,
Benjamin M. Zwickl
Abstract:
Joining a research group is one of the most important events on a graduate student's path to becoming an independent physics researcher and earning a PhD. However, graduate students' perspectives on the experience of finding a research group are not well-documented in the literature. Understanding these perspectives is crucial for evaluating whether departments are providing students with adequate…
▽ More
Joining a research group is one of the most important events on a graduate student's path to becoming an independent physics researcher and earning a PhD. However, graduate students' perspectives on the experience of finding a research group are not well-documented in the literature. Understanding these perspectives is crucial for evaluating whether departments are providing students with adequate support while they search for a research group, and how difficulties during this process contribute to attrition. Semi-structured interviews with N=20 first and second year physics PhD students reveal that incoming graduate students see joining a research group as a significant decision, and recognize that it may impact whether they will be able to complete the program. We found that students who struggled to find a group felt isolated and worried about falling behind their peers, whereas students who were able to immerse themselves in a positive group environment reported increased sense of belonging in their programs. The process of finding a research group often held differential importance for students identifying as women and non-binary, who at times reported having to deprioritize their preferred research topic in order to be part of a more inclusive working environment. Although incoming graduate students characterized joining a research group as a significant decision, they often felt unprepared to make it. Moreover, they perceived an overall lack of guidance and structure from their departments, and characterized coursework as a barrier to searching for a group. Our findings suggest that providing students with better support during their group search process could help improve retention, particularly for traditionally underrepresented students, and improve students' overall satisfaction in their graduate programs.
△ Less
Submitted 6 February, 2024; v1 submitted 7 November, 2023;
originally announced November 2023.
-
First Results from a Broadband Search for Dark Photon Dark Matter in the $44$ to $52\,μ$eV range with a coaxial dish antenna
Authors:
Stefan Knirck,
Gabe Hoshino,
Mohamed H. Awida,
Gustavo I. Cancelo,
Martin Di Federico,
Benjamin Knepper,
Alex Lapuente,
Mira Littmann,
David W. Miller,
Donald V. Mitchell,
Derrick Rodriguez,
Mark K. Ruschman,
Matthew A. Sawtell,
Leandro Stefanazzi,
Andrew Sonnenschein,
Gary W. Teafoe,
Daniel Bowring,
G. Carosi,
Aaron Chou,
Clarence L. Chang,
Kristin Dona,
Rakshya Khatiwada,
Noah A. Kurinsky,
Jesse Liu,
Cristián Pena
, et al. (3 additional authors not shown)
Abstract:
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are re…
▽ More
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon - photon mixing parameters $χ\gtrsim 10^{-12}$ in this range at 90% confidence level. This surpasses existing constraints by about two orders of magnitude and is the most stringent bound on dark photons in this range below 49 $μ$eV.
△ Less
Submitted 3 May, 2024; v1 submitted 20 October, 2023;
originally announced October 2023.
-
Inequities and misaligned expectations in PhD students' search for a research group
Authors:
Mike Verostek,
Casey W. Miller,
Benjamin M. Zwickl
Abstract:
Joining a research group is one of the most important events on a graduate student's path to earning a PhD, but the ways students go about searching for a group remain largely unstudied. It is therefore crucial to investigate whether departments are equitably supporting students as they look for an advisor, especially as students today enter graduate school with more diverse backgrounds than ever…
▽ More
Joining a research group is one of the most important events on a graduate student's path to earning a PhD, but the ways students go about searching for a group remain largely unstudied. It is therefore crucial to investigate whether departments are equitably supporting students as they look for an advisor, especially as students today enter graduate school with more diverse backgrounds than ever before. To better understand the phenomenon of finding a research group, we use a comparative case study approach to contrast important aspects of two physics PhD students' experiences. Semi-structured interviews with the students chronicled their interactions with departments, faculty, and the graduate student community, and described the resources they found most and least helpful. Our results reveal significant disparities in students' perceptions of how to find an advisor, as well as inequities in resources that negatively influenced one student's search. We also uncover substantial variation regarding when in their academic careers the students began searching for a graduate advisor, indicating the importance of providing students with consistent advising throughout their undergraduate and graduate experiences.
△ Less
Submitted 13 July, 2023;
originally announced July 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Generation and motion of interfaces in a mass-conserving reaction-diffusion system
Authors:
Pearson W. Miller,
Daniel Fortunato,
Matteo Novaga,
Stanislav Y. Shvartsman,
Cyrill B. Muratov
Abstract:
Reaction-diffusion models with nonlocal constraints naturally arise as limiting cases of coupled bulk-surface models of intracellular signalling. In this paper, a minimal, mass-conserving model of cell-polarization on a curved membrane is analyzed in the limit of slow surface diffusion. Using the tools of formal asymptotics and calculus of variations, we study the characteristic wave-pinning behav…
▽ More
Reaction-diffusion models with nonlocal constraints naturally arise as limiting cases of coupled bulk-surface models of intracellular signalling. In this paper, a minimal, mass-conserving model of cell-polarization on a curved membrane is analyzed in the limit of slow surface diffusion. Using the tools of formal asymptotics and calculus of variations, we study the characteristic wave-pinning behavior of this system on three dynamical timescales. On the short timescale, generation of an interface separating high- and low-concentration domains is established under suitable conditions. Intermediate timescale dynamics is shown to lead to a uniform growth or shrinking of these domains to sizes which are fixed by global parameters. Finally, the long time dynamics reduces to area-preserving geodesic curvature flow that may lead to multi-interface steady state solutions. These results provide a foundation for studying cell polarization and related phenomena in biologically relevant geometries.
△ Less
Submitted 2 October, 2022;
originally announced October 2022.
-
The Profiled Feldman-Cousins technique for confidence interval construction in the presence of nuisance parameters
Authors:
M. A. Acero,
B. Acharya,
P. Adamson,
L. Aliaga,
N. Anfimov,
A. Antoshkin,
E. Arrieta-Diaz,
L. Asquith,
A. Aurisano,
A. Back,
C. Backhouse,
M. Baird,
N. Balashov,
P. Baldi,
B. A. Bambah,
S. Bashar,
A. Bat,
K. Bays,
R. Bernstein,
V. Bhatnagar,
D. Bhattarai,
B. Bhuyan,
J. Bian,
A. C. Booth,
R. Bowles
, et al. (196 additional authors not shown)
Abstract:
Measuring observables to constrain models using maximum-likelihood estimation is fundamental to many physics experiments. The Profiled Feldman-Cousins method described here is a potential solution to common challenges faced in constructing accurate confidence intervals: small datasets, bounded parameters, and the need to properly handle nuisance parameters. This method achieves more accurate frequ…
▽ More
Measuring observables to constrain models using maximum-likelihood estimation is fundamental to many physics experiments. The Profiled Feldman-Cousins method described here is a potential solution to common challenges faced in constructing accurate confidence intervals: small datasets, bounded parameters, and the need to properly handle nuisance parameters. This method achieves more accurate frequentist coverage than other methods in use, and is generally applicable to the problem of parameter estimation in neutrino oscillations and similar measurements. We describe an implementation of this method in the context of the NOvA experiment.
△ Less
Submitted 1 August, 2022; v1 submitted 28 July, 2022;
originally announced July 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Innovations in trigger and data acquisition systems for next-generation physics facilities
Authors:
Rainer Bartoldus,
Catrin Bernius,
David W. Miller
Abstract:
Data-intensive physics facilities are increasingly reliant on heterogeneous and large-scale data processing and computational systems in order to collect, distribute, process, filter, and analyze the ever increasing huge volumes of data being collected. Moreover, these tasks are often performed in hard real-time or quasi real-time processing pipelines that place extreme constraints on various para…
▽ More
Data-intensive physics facilities are increasingly reliant on heterogeneous and large-scale data processing and computational systems in order to collect, distribute, process, filter, and analyze the ever increasing huge volumes of data being collected. Moreover, these tasks are often performed in hard real-time or quasi real-time processing pipelines that place extreme constraints on various parameters and design choices for those systems. Consequently, a large number and variety of challenges are faced to design, construct, and operate such facilities. This is especially true at the energy and intensity frontiers of particle physics where bandwidths of raw data can exceed 100 TB/s of heterogeneous, high-dimensional data sourced from 300M+ individual sensors. Data filtering and compression algorithms deployed at these facilities often operate at the level of 1 part in $10^5$, and once executed, these algorithms drive the data curation process, further highlighting the critical roles that these systems have in the physics impact of those endeavors. This White Paper aims to highlight the challenges that these facilities face in the design of the trigger and data acquisition instrumentation and systems, as well as in their installation, commissioning, integration and operation, and in building the domain knowledge and technical expertise required to do so.
△ Less
Submitted 17 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Broadband solenoidal haloscope for terahertz axion detection
Authors:
Jesse Liu,
Kristin Dona,
Gabe Hoshino,
Stefan Knirck,
Noah Kurinsky,
Matthew Malaker,
David W. Miller,
Andrew Sonnenschein,
Mohamed H. Awida,
Peter S. Barry,
Karl K. Berggren,
Daniel Bowring,
Gianpaolo Carosi,
Clarence Chang,
Aaron Chou,
Rakshya Khatiwada,
Samantha Lewis,
Juliang Li,
Sae Woo Nam,
Omid Noroozian,
Tony X. Zhou
Abstract:
We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry en…
▽ More
We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m$^{2}$ barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires $<10^{-20}$ W/$\sqrt{\textrm{Hz}}$ sensor noise equivalent power with a 10 T solenoid and 10 m$^{2}$ barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.
△ Less
Submitted 24 March, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Frequency shifts in the EPR spectrum of $^{39}$K due to spin-exchange collisions with polarized $^3$He and precise $^3$He polarimetry
Authors:
Sumudu Katugampola,
Christopher Jantzi,
David A. Keder,
G. Wilson Miller,
Vladimir Nelyubin,
Huong Nguyen,
Sina Tafti,
William A. Tobias,
Gordon D. Cates
Abstract:
The Zeeman splittings and EPR frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter $κ_0$ that is unique to each alkali-metal atom - noble-gas pair. We present a precise measurement of $κ_0$ for the $^{39}$K-$^3$He system with a relative accuracy o…
▽ More
The Zeeman splittings and EPR frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter $κ_0$ that is unique to each alkali-metal atom - noble-gas pair. We present a precise measurement of $κ_0$ for the $^{39}$K-$^3$He system with a relative accuracy of better than 1\%. A critical component of achieving sub-percent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter $κ_0$ plays an important role in establishing the absolute polarization of $^3$He in a variety of contexts, including polarized targets for electron scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using $κ_0$ for polarimetry purposes. Just as important, the work presented here represents the first {\it direct} measurement of $κ_0$ for the $^{39}$K-$^3$He system; previous values for $κ_0$ in the $^{39}$K-$^3$He system relied on a chain of measurements that were benchmarked by previous measurements of $κ_0$ in the Rb-$^3$He system.
△ Less
Submitted 16 October, 2021; v1 submitted 9 September, 2021;
originally announced September 2021.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments
Authors:
Kristin Dona,
Jesse Liu,
Noah Kurinsky,
David Miller,
Pete Barry,
Clarence Chang,
Andrew Sonnenschein
Abstract:
Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangeme…
▽ More
Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.
△ Less
Submitted 14 April, 2021;
originally announced April 2021.
-
Sensitivity to millicharged particles in future proton-proton collisions at the LHC
Authors:
A. Ball,
J. Brooke,
C. Campagnari,
M. Carrigan,
M. Citron,
A De Roeck,
M. Ezzeldine,
B. Francis,
M. Gastal,
M. Ghimire,
J. Goldstein,
F. Golf,
A. Haas,
R. Heller,
C. S. Hill,
L. Lavezzo,
R. Loos,
S. Lowette,
B. Manley,
B. Marsh,
D. W. Miller,
B. Odegard,
R. Schmitz,
F. Setti H. Shakeshaft,
D. Stuart
, et al. (3 additional authors not shown)
Abstract:
We report on the expected sensitivity of dedicated scintillator-based detectors at the LHC for elementary particles with charges much smaller than the electron charge. The dataset provided by a prototype scintillator-based detector is used to characterise the performance of the detector and provide an accurate background projection. Detector designs, including a novel slab detector configuration,…
▽ More
We report on the expected sensitivity of dedicated scintillator-based detectors at the LHC for elementary particles with charges much smaller than the electron charge. The dataset provided by a prototype scintillator-based detector is used to characterise the performance of the detector and provide an accurate background projection. Detector designs, including a novel slab detector configuration, are considered for the data taking period of the LHC to start in 2022 (Run 3) and for the high luminosity LHC. With the Run 3 dataset, the existence of new particles with masses between 10 MeV and 45 GeV could be excluded at 95% confidence level for charges between 0.003e and 0.3e, depending on their mass. With the high luminosity LHC dataset, the expected limits would reach between 10 MeV and 80 GeV for charges between 0.0018e and 0.3e, depending on their mass
△ Less
Submitted 13 August, 2021; v1 submitted 14 April, 2021;
originally announced April 2021.
-
Towards an Interpretable Data-driven Trigger System for High-throughput Physics Facilities
Authors:
Chinmaya Mahesh,
Kristin Dona,
David W. Miller,
Yuxin Chen
Abstract:
Data-intensive science is increasingly reliant on real-time processing capabilities and machine learning workflows, in order to filter and analyze the extreme volumes of data being collected. This is especially true at the energy and intensity frontiers of particle physics where bandwidths of raw data can exceed 100 Tb/s of heterogeneous, high-dimensional data sourced from hundreds of millions of…
▽ More
Data-intensive science is increasingly reliant on real-time processing capabilities and machine learning workflows, in order to filter and analyze the extreme volumes of data being collected. This is especially true at the energy and intensity frontiers of particle physics where bandwidths of raw data can exceed 100 Tb/s of heterogeneous, high-dimensional data sourced from hundreds of millions of individual sensors. In this paper, we introduce a new data-driven approach for designing and optimizing high-throughput data filtering and trigger systems such as those in use at physics facilities like the Large Hadron Collider (LHC). Concretely, our goal is to design a data-driven filtering system with a minimal run-time cost for determining which data event to keep, while preserving (and potentially improving upon) the distribution of the output as generated by the hand-designed trigger system. We introduce key insights from interpretable predictive modeling and cost-sensitive learning in order to account for non-local inefficiencies in the current paradigm and construct a cost-effective data filtering and trigger model that does not compromise physics coverage.
△ Less
Submitted 14 April, 2021;
originally announced April 2021.
-
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
N. Anfimov,
A. Ankowski,
M. Antonova,
S. Antusch
, et al. (1041 additional authors not shown)
Abstract:
This report describes the conceptual design of the DUNE near detector
This report describes the conceptual design of the DUNE near detector
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Supernova Model Discrimination with Hyper-Kamiokande
Authors:
Hyper-Kamiokande Collaboration,
:,
K. Abe,
P. Adrich,
H. Aihara,
R. Akutsu,
I. Alekseev,
A. Ali,
F. Ameli,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
A. Araya,
Y. Asaoka,
Y. Ashida,
V. Aushev,
F. Ballester,
I. Bandac,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz-Kwasniak,
M. Bellato,
V. Berardi,
M. Bergevin
, et al. (478 additional authors not shown)
Abstract:
Core-collapse supernovae are among the most magnificent events in the observable universe. They produce many of the chemical elements necessary for life to exist and their remnants -- neutron stars and black holes -- are interesting astrophysical objects in their own right. However, despite millennia of observations and almost a century of astrophysical study, the explosion mechanism of core-colla…
▽ More
Core-collapse supernovae are among the most magnificent events in the observable universe. They produce many of the chemical elements necessary for life to exist and their remnants -- neutron stars and black holes -- are interesting astrophysical objects in their own right. However, despite millennia of observations and almost a century of astrophysical study, the explosion mechanism of core-collapse supernovae is not yet well understood. Hyper-Kamiokande is a next-generation neutrino detector that will be able to observe the neutrino flux from the next galactic core-collapse supernova in unprecedented detail. We focus on the first 500 ms of the neutrino burst, corresponding to the accretion phase, and use a newly-developed, high-precision supernova event generator to simulate Hyper-Kamiokande's response to five different supernova models. We show that Hyper-Kamiokande will be able to distinguish between these models with high accuracy for a supernova at a distance of up to 100 kpc. Once the next galactic supernova happens, this ability will be a powerful tool for guiding simulations towards a precise reproduction of the explosion mechanism observed in nature.
△ Less
Submitted 20 July, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
Search for Slow Magnetic Monopoles with the NOvA Detector on the Surface
Authors:
NOvA Collaboration,
M. A. Acero,
P. Adamson,
L. Aliaga,
T. Alion,
V. Allakhverdian,
N. Anfimov,
A. Antoshkin,
E. Arrieta-Diaz,
L. Asquith,
A. Aurisano,
A. Back,
C. Backhouse,
M. Baird,
N. Balashov,
P. Baldi,
B. A. Bambah,
S. Bashar,
K. Bays,
S. Bending,
R. Bernstein,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
J. Blair
, et al. (174 additional authors not shown)
Abstract:
We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $2\times 10^{-14} \mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for mon…
▽ More
We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $2\times 10^{-14} \mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for monopole speed $6\times 10^{-4} < β< 5\times 10^{-3}$ and mass greater than $5\times 10^{8}$ GeV. Because of NOvA's small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.
△ Less
Submitted 5 January, 2021; v1 submitted 10 September, 2020;
originally announced September 2020.
-
Supernova Neutrino Burst Detection with the Deep Underground Neutrino Experiment
Authors:
DUNE collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (949 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The gen…
▽ More
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The general capabilities of DUNE for neutrino detection in the relevant few- to few-tens-of-MeV neutrino energy range will be described. As an example, DUNE's ability to constrain the $ν_e$ spectral parameters of the neutrino burst will be considered.
△ Less
Submitted 29 May, 2021; v1 submitted 15 August, 2020;
originally announced August 2020.
-
Classical $n$-body system in geometrical and volume variables. I. Three-body case
Authors:
A. M. Escobar-Ruiz,
R. Linares,
Alexander V Turbiner,
Willard Miller Jr
Abstract:
We consider the classical 3-body system with $d$ degrees of freedom $(d>1)$ at zero total angular momentum. The study is restricted to potentials $V$ that depend solely on relative (mutual) distances $r_{ij}=\mid {\bf r}_i - {\bf r}_j\mid$ between bodies. Following the proposal by J. L. Lagrange, in the center-of-mass frame we introduce the relative distances (complemented by angles) as generalize…
▽ More
We consider the classical 3-body system with $d$ degrees of freedom $(d>1)$ at zero total angular momentum. The study is restricted to potentials $V$ that depend solely on relative (mutual) distances $r_{ij}=\mid {\bf r}_i - {\bf r}_j\mid$ between bodies. Following the proposal by J. L. Lagrange, in the center-of-mass frame we introduce the relative distances (complemented by angles) as generalized coordinates and show that the kinetic energy does not depend on $d$, confirming results by Murnaghan (1936) at $d=2$ and van Kampen-Wintner (1937) at $d=3$, where it corresponds to a 3D solid body. Realizing $\mathbb{Z}_2$-symmetry $(r_{ij} \rightarrow -r_{ij})$ we introduce new variables $ρ_{ij}=r_{ij}^2$, which allows us to make the tensor of inertia non-singular for binary collisions. In these variables the kinetic energy is a polynomial function in the $ρ$-phase space. The 3 body positions form a triangle (of interaction) and the kinetic energy is $\mathcal{S}_3$-permutationally invariant wrt interchange of body positions and masses (as well as wrt interchange of edges of the triangle and masses). For equal masses, we use lowest order symmetric polynomial invariants of $\mathbb{Z}_2^{\otimes3} \oplus \mathcal{S}_3$ to define new generalized coordinates, they are called the {\it geometrical variables}. Two of them of the lowest order (sum of squares of sides of triangle and square of the area) are called {\it volume variables}. We study three examples in some detail: (I) 3-body Newton gravity in $d=3$, (II) 3-body choreography in $d=2$ on the algebraic lemniscate by Fujiwara et al where the problem becomes one-dimensional in the geometrical variables, and (III) the (an)harmonic oscillator.
△ Less
Submitted 14 July, 2021; v1 submitted 23 July, 2020;
originally announced July 2020.
-
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
Authors:
DUNE Collaboration,
B. Abi,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
G. Adamov,
M. Adamowski,
D. Adams,
P. Adrien,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga
, et al. (970 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, $dE/dx$ calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.
△ Less
Submitted 3 June, 2021; v1 submitted 13 July, 2020;
originally announced July 2020.
-
Neutrino interaction classification with a convolutional neural network in the DUNE far detector
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (951 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure $CP$-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electr…
▽ More
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure $CP$-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electron neutrino (antineutrino) selection efficiency peaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between 2-5 GeV. The muon neutrino (antineutrino) event selection is found to have a maximum efficiency of 96% (97%) and exceeds 90% (95%) efficiency for reconstructed neutrino energies above 2 GeV. When considering all electron neutrino and antineutrino interactions as signal, a selection purity of 90% is achieved. These event selections are critical to maximize the sensitivity of the experiment to $CP$-violating effects.
△ Less
Submitted 10 November, 2020; v1 submitted 26 June, 2020;
originally announced June 2020.
-
Lorentz Group Equivariant Neural Network for Particle Physics
Authors:
Alexander Bogatskiy,
Brandon Anderson,
Jan T. Offermann,
Marwah Roussi,
David W. Miller,
Risi Kondor
Abstract:
We present a neural network architecture that is fully equivariant with respect to transformations under the Lorentz group, a fundamental symmetry of space and time in physics. The architecture is based on the theory of the finite-dimensional representations of the Lorentz group and the equivariant nonlinearity involves the tensor product. For classification tasks in particle physics, we demonstra…
▽ More
We present a neural network architecture that is fully equivariant with respect to transformations under the Lorentz group, a fundamental symmetry of space and time in physics. The architecture is based on the theory of the finite-dimensional representations of the Lorentz group and the equivariant nonlinearity involves the tensor product. For classification tasks in particle physics, we demonstrate that such an equivariant architecture leads to drastically simpler models that have relatively few learnable parameters and are much more physically interpretable than leading approaches that use CNNs and point cloud approaches. The competitive performance of the network is demonstrated on a public classification dataset [27] for tagging top quark decays given energy-momenta of jet constituents produced in proton-proton collisions.
△ Less
Submitted 8 June, 2020;
originally announced June 2020.
-
Supernova neutrino detection in NOvA
Authors:
NOvA Collaboration,
M. A. Acero,
P. Adamson,
G. Agam,
L. Aliaga,
T. Alion,
V. Allakhverdian,
N. Anfimov,
A. Antoshkin,
E. Arrieta-Diaz,
L. Asquith,
A. Aurisano,
A. Back,
C. Backhouse,
M. Baird,
N. Balashov,
P. Baldi,
B. A. Bambah,
S. Bashar,
K. Bays,
S. Bending,
R. Bernstein,
V. Bhatnagar,
B. Bhuyan,
J. Bian
, et al. (177 additional authors not shown)
Abstract:
The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Fermilab NuMI beam. These detectors are also sensitive to the flux of neutrinos which are emitted during a core-collapse supernova through inverse beta decay interactions on carbon at energies of…
▽ More
The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Fermilab NuMI beam. These detectors are also sensitive to the flux of neutrinos which are emitted during a core-collapse supernova through inverse beta decay interactions on carbon at energies of $\mathcal{O}(10~\text{MeV})$. This signature provides a means to study the dominant mode of energy release for a core-collapse supernova occurring in our galaxy. We describe the data-driven software trigger system developed and employed by the NOvA experiment to identify and record neutrino data from nearby galactic supernovae. This technique has been used by NOvA to self-trigger on potential core-collapse supernovae in our galaxy, with an estimated sensitivity reaching out to 10~kpc distance while achieving a detection efficiency of 23\% to 49\% for supernovae from progenitor stars with masses of 9.6M$_\odot$ to 27M$_\odot$, respectively.
△ Less
Submitted 29 July, 2020; v1 submitted 14 May, 2020;
originally announced May 2020.
-
Search for millicharged particles in proton-proton collisions at $\sqrt{s} = 13$ TeV
Authors:
A. Ball,
G. Beauregard,
J. Brooke,
C. Campagnari,
M. Carrigan,
M. Citron,
J. De La Haye,
A. De Roeck,
Y. Elskens,
R. Escobar Franco,
M. Ezeldine,
B. Francis,
M. Gastal,
M. Ghimire,
J. Goldstein,
F. Golf,
J. Guiang,
A. Haas,
R. Heller,
C. S. Hill,
L. Lavezzo,
R. Loos,
S. Lowette,
G. Magill,
B. Manley
, et al. (13 additional authors not shown)
Abstract:
We report on a search for elementary particles with charges much smaller than the electron charge using a data sample of proton-proton collisions provided by the CERN Large Hadron Collider in 2018, corresponding to an integrated luminosity of 37.5 fb$^{-1}$ at a center-of-mass energy of 13 TeV. A prototype scintillator-based detector is deployed to conduct the first search at a hadron collider sen…
▽ More
We report on a search for elementary particles with charges much smaller than the electron charge using a data sample of proton-proton collisions provided by the CERN Large Hadron Collider in 2018, corresponding to an integrated luminosity of 37.5 fb$^{-1}$ at a center-of-mass energy of 13 TeV. A prototype scintillator-based detector is deployed to conduct the first search at a hadron collider sensitive to particles with charges ${\leq}0.1e$. The existence of new particles with masses between 20 and 4700 MeV is excluded at 95% confidence level for charges between $0.006e$ and $0.3e$, depending on their mass. New sensitivity is achieved for masses larger than $700$ MeV.
△ Less
Submitted 13 May, 2020;
originally announced May 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume IV: Far Detector Single-phase Technology
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-clas…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume III: DUNE Far Detector Technical Coordination
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Exper…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed.
This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-clas…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based.
This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized.
This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.
△ Less
Submitted 25 March, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume I: Introduction to DUNE
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Exper…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. This TDR is intended to justify the technical choices for the far detector that flow down from the high-level physics goals through requirements at all levels of the Project. Volume I contains an executive summary that introduces the DUNE science program, the far detector and the strategy for its modular designs, and the organization and management of the Project. The remainder of Volume I provides more detail on the science program that drives the choice of detector technologies and on the technologies themselves. It also introduces the designs for the DUNE near detector and the DUNE computing model, for which DUNE is planning design reports.
Volume II of this TDR describes DUNE's physics program in detail. Volume III describes the technical coordination required for the far detector design, construction, installation, and integration, and its organizational structure. Volume IV describes the single-phase far detector technology. A planned Volume V will describe the dual-phase technology.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Three-body closed chain of interactive (an)harmonic oscillators and the algebra $sl(4)$
Authors:
Alexander V Turbiner,
Willard Miller Jr,
Adrian M Escobar-Ruiz
Abstract:
In this work we study 2- and 3-body oscillators with quadratic and sextic pairwise potentials which depend on relative distances, $|{\bf r}_i - {\bf r}_j |$, between particles. The two-body harmonic oscillator is two-parametric and can be reduced to a one-dimensional radial Jacobi oscillator, while in the 3-body case such a reduction is not possible in general. Our study is restricted to solutions…
▽ More
In this work we study 2- and 3-body oscillators with quadratic and sextic pairwise potentials which depend on relative distances, $|{\bf r}_i - {\bf r}_j |$, between particles. The two-body harmonic oscillator is two-parametric and can be reduced to a one-dimensional radial Jacobi oscillator, while in the 3-body case such a reduction is not possible in general. Our study is restricted to solutions in the space of relative motion which are functions of mutual (relative) distances only ($S$-states). We pay special attention to the cases where the masses of the particles and spring constants are unequal as well as to the atomic, where one mass is infinite, and molecular, where two masses are infinite, limits. In general, three-body harmonic oscillator is 7-parametric depending on 3 masses and 3 spring constants, and frequency. In particular, the first and second order integrals of the 3-body oscillator for unequal masses are searched: it is shown that for certain relations involving masses and spring constants the system becomes maximally (minimally) superintegrable in the case of two (one) relations.
△ Less
Submitted 6 October, 2019; v1 submitted 25 September, 2019;
originally announced September 2019.
-
Typical Physics PhD Admissions Criteria Limit Access to Underrepresented Groups but Fail to Predict Doctoral Completion, including some additional information
Authors:
Casey W. Miller,
Benjamin M. Zwickl,
Julie R. Posselt,
Rachel T. Silvestrini,
Theodore Hodapp
Abstract:
This work aims to understand how effective the typical admissions criteria used in physics are at identifying students who will complete the PhD. Through a multivariate statistical analysis of a sample that includes roughly one in eight students who entered physics PhD programs from 2000-2010, we find that the traditional admissions metrics of undergraduate GPA and the Graduate Records Examination…
▽ More
This work aims to understand how effective the typical admissions criteria used in physics are at identifying students who will complete the PhD. Through a multivariate statistical analysis of a sample that includes roughly one in eight students who entered physics PhD programs from 2000-2010, we find that the traditional admissions metrics of undergraduate GPA and the Graduate Records Examination (GRE) Quantitative, Verbal, and Physics Subject Tests do not predict completion in US physics graduate programs with the efficacy often assumed by admissions committees. We find only undergraduate GPA to have a statistically significant association with physics PhD completion across all models studied. In no model did GRE Physics or GRE Verbal predict PhD completion. GRE Quantitative scores had statistically significant relationships with PhD completion in two of four models studied. However, in practice, probability of completing the PhD changed by less than 10 percentage points for students scoring in the 10 ^th vs 90 ^th percentile of US test takers that were physics majors. Noting the significant race, gender, and citizenship gaps in GRE scores, these findings indicate that the heavy reliance on these test scores within typical PhD admissions process is a deterrent to increasing access, diversity, and equity in physics. Misuse of GRE scores selects against already-underrepresented groups and US citizens with tools that fail to meaningfully predict PhD completion. This is a draft; see the journal for the published version.
Additionally included in blue text are several responses to queries about this work.
△ Less
Submitted 5 July, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Observation of seasonal variation of atmospheric multiple-muon events in the NOvA Near Detector
Authors:
M. A. Acero,
P. Adamson,
L. Aliaga,
T. Alion,
V. Allakhverdian,
S. Altakarli,
N. Anmov,
A. Antoshkin,
A. Aurisano,
A. Back,
C. Backhouse,
M. Baird,
N. Balashov,
P. Baldi,
B. A. Bambah,
S. Bashar,
K. Bays,
S. Bending,
R. Bernstein,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
J. Blair,
A. C. Booth,
P. Bour
, et al. (166 additional authors not shown)
Abstract:
Using two years of data from the NOvA Near Detector at Fermilab, we report a seasonal variation of cosmic ray induced multiple-muon event rates which has an opposite phase to the seasonal variation in the atmospheric temperature. The strength of the seasonal multipl$ increase as a function of the muon multiplicity. However, no significant dependence of the strength of the seasonal variation of the…
▽ More
Using two years of data from the NOvA Near Detector at Fermilab, we report a seasonal variation of cosmic ray induced multiple-muon event rates which has an opposite phase to the seasonal variation in the atmospheric temperature. The strength of the seasonal multipl$ increase as a function of the muon multiplicity. However, no significant dependence of the strength of the seasonal variation of the multiple-muon variation is seen as a function of the muon zenith angle, or the spatial or angular separation between the correlated muons.
△ Less
Submitted 8 July, 2019; v1 submitted 29 April, 2019;
originally announced April 2019.
-
Fractal light from lasers
Authors:
Hend Sroor,
Darryl Naidoo,
Steven W. Miller,
John Nelson,
Johannes Courtial,
Andrew Forbes
Abstract:
Fractals, complex shapes with structure at multiple scales, have long been observed in Nature: as symmetric fractals in plants and sea shells, and as statistical fractals in clouds, mountains and coastlines. With their highly polished spherical mirrors, laser resonators are almost the precise opposite of Nature, and so it came as a surprise when, in 1998, transverse intensity cross-sections of the…
▽ More
Fractals, complex shapes with structure at multiple scales, have long been observed in Nature: as symmetric fractals in plants and sea shells, and as statistical fractals in clouds, mountains and coastlines. With their highly polished spherical mirrors, laser resonators are almost the precise opposite of Nature, and so it came as a surprise when, in 1998, transverse intensity cross-sections of the eigenmodes of unstable canonical resonators were predicted to be fractals [Karman et al., Nature 402, 138 (1999)]. Experimental verification has so far remained elusive. Here we observe a variety of fractal shapes in transverse intensity cross-sections through the lowest-loss eigenmodes of unstable canonical laser resonators, thereby demonstrating the controlled generation of fractal light inside a laser cavity. We also advance the existing theory of fractal laser modes, first by predicting 3D self-similar fractal structure around the centre of the magnified self-conjugate plane, second by showing, quantitatively, that intensity cross-sections are most self-similar in the magnified self-conjugate plane. Our work offers a significant advance in the understanding of a fundamental symmetry of Nature as found in lasers.
△ Less
Submitted 11 September, 2018; v1 submitted 6 September, 2018;
originally announced September 2018.
-
The DUNE Far Detector Interim Design Report, Volume 3: Dual-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 3 describes the dual-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report, Volume 2: Single-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 2 describes the single-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
The Single-Phase ProtoDUNE Technical Design Report
Authors:
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. L. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
T. Alion,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
J. dos Anjos,
A. Ankowski,
J. Anthony,
M. Antonello,
A. Aranda Fernandez,
A. Ariga,
T. Ariga,
E. Arrieta Diaz,
J. Asaadi
, et al. (806 additional authors not shown)
Abstract:
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass…
▽ More
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.
△ Less
Submitted 27 July, 2017; v1 submitted 21 June, 2017;
originally announced June 2017.