-
HighNESS Conceptual Design Report: Volume I
Authors:
V. Santoro,
O. Abou El Kheir,
D. Acharya,
M. Akhyani,
K. H. Andersen,
J. Barrow,
P. Bentley,
M. Bernasconi,
M. Bertelsen,
Y. Bessler,
A. Bianchi,
G. Brooijmans,
L. Broussard,
T. Brys,
M. Busi,
D. Campi,
A. Chambon,
J. Chen,
V. Czamler,
P. Deen,
D. D. DiJulio,
E. Dian,
L. Draskovits,
K. Dunne,
M. El Barbari
, et al. (65 additional authors not shown)
Abstract:
The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world's most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron…
▽ More
The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world's most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2--20\,Å), very cold (VCN, 10--120\,Å), and ultracold (UCN, ${>}\,{500}$\,Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.
△ Less
Submitted 28 May, 2024; v1 submitted 29 September, 2023;
originally announced September 2023.
-
Development of a High Intensity Neutron Source at the European Spallation Source: The HighNESS project
Authors:
V. Santoro,
K. H. Andersen,
M. Bernasconi,
M. Bertelsen,
Y. Beßler,
D. Campi,
V. Czamler,
D. D. Di Julio,
E. Diane,
K. Dunne,
P. Fierlinger,
A. Gaye,
G. Gorini,
C. Happe,
T. Kittelmann,
E. B. Klinkby,
Z. Kokai,
R. Kolevatov,
B. Lauritzen,
R. Linander,
J. I. Marquez Damian,
B. Meirose,
F. Mezei,
D. Milstead,
G. Muhrer
, et al. (14 additional authors not shown)
Abstract:
The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that will operate the world's most powerful pulsed neutron source. Supported by a 3M Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source below the spallation target. Compa…
▽ More
The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that will operate the world's most powerful pulsed neutron source. Supported by a 3M Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source below the spallation target. Compared to the first source, located above the spallation target and designed for high cold and thermal brightness, the new source will provide higher intensity, and a shift to longer wavelengths in the spectral regions of cold (2 /- 20 Å), very cold (VCN, 10 /- 120 Å), and ultra cold (UCN, > 500 Å) neutrons. The core of the second source will consist of a large liquid deuterium moderator to deliver a high flux of cold neutrons and to serve secondary VCN and UCN sources, for which different options are under study. The features of these new sources will boost several areas of condensed matter research and will provide unique opportunities in fundamental physics. Part of the HighNESS project is also dedicated to the development of future instruments that will make use of the new source and will complement the initial suite of instruments in construction at ESS. The HighNESS project started in October 2020. In this paper, the ongoing developments and the results obtained in the first year are described.
△ Less
Submitted 8 April, 2022;
originally announced April 2022.
-
Neutron Scattering Instrumentation at Compact Neutron Sources
Authors:
Sarah Böhm,
Tobias Cronert,
Jan-Philipp Dabrück,
Xavier Fabrèges,
Thomas Gutberlet,
Ferenc Mezei,
Alain Letourneau,
Alain Menelle,
Frédéric Ott,
Ulrich Rücker,
Hoang Tran,
Jorg Voïgt,
Paul Zakalek
Abstract:
There is currently a strong interest in Compact Accelerator-based Neutron Source (CANS) as a possible new type of source for neutron scattering experiments. A workshop around the "Neutron scattering instrumentation around CANS" was organized in July 2017 between several European institutes. This report summarizes the main outcome of the discussions. The document is aiming at providing general guid…
▽ More
There is currently a strong interest in Compact Accelerator-based Neutron Source (CANS) as a possible new type of source for neutron scattering experiments. A workshop around the "Neutron scattering instrumentation around CANS" was organized in July 2017 between several European institutes. This report summarizes the main outcome of the discussions. The document is aiming at providing general guidelines for the instrumentation around CANS. Detailed technical discussions are or will be provided in specific publications.
△ Less
Submitted 7 September, 2018;
originally announced September 2018.
-
Enhanced Performance Neutron Scattering Spectroscopy by Use of Correlation Techniques
Authors:
F. Mezei,
M. T. Caccamo,
F. Migliardo,
S. Magazù
Abstract:
Neutron correlation spectroscopy can exceed direct spectroscopy in the incoming beam intensity by up to two orders of magnitude at the same energy resolution. However, the propagation of the counting noise in the correlation algorithm of data reduction is disadvantageous for the lowest intensity parts of the observed spectrum. To mitigate this effect at pulsed neutron sources we propose two dimens…
▽ More
Neutron correlation spectroscopy can exceed direct spectroscopy in the incoming beam intensity by up to two orders of magnitude at the same energy resolution. However, the propagation of the counting noise in the correlation algorithm of data reduction is disadvantageous for the lowest intensity parts of the observed spectrum. To mitigate this effect at pulsed neutron sources we propose two dimensional time-of-flight recording of each neutron detection event: with respect to both the neutron source pulses and to the rotation phase of the pseudo-random beam modulation statistical chopper. We have identified a formulation of the data reduction algorithm by matching the data processing time channel width to the inherent time resolution of this chopper, which makes the reconstruction of the direct time-of-flight spectra exact and independent of all other contributions to instrumental resolution. Two ways are proposed for most flexible choice of intensity vs. resolution without changing the statistical chopper or its speed: changing the size of the beam window during the experiment or varying intensity and resolution options in the data reduction algorithm after the experiment. This latter is a unique and very promising new potential offered by the correlation method. Furthermore, it displays reduced sensitivity to external background, also due to the much higher signal intensity. This is particularly advantageous for extending the operational range to higher neutron energies. In hot and thermal neutron vibrational spectroscopy, the statistical chopper approach allows us to achieve very significant gains in spectrometer efficiency compared to using conventional choppers. High intensity for the most intense features in the spectra and the reduced sensitivity to sample independent background make correlation spectroscopy a most powerful choice for studying small samples.
△ Less
Submitted 12 September, 2016;
originally announced September 2016.
-
Voluminous D2 source for intense cold neutron beam production at the ESS
Authors:
Esben Klinkby,
Konstantin Batkov,
Ferenc Mezei,
Troels Schønfeldt,
Alan Takibayev,
Luca Zanini
Abstract:
The development of the flat moderator concept at ESS recently opened up the possibility that a single flat moderator above the target could serve all the scattering instruments, that rely on high brightness. This would allow for the introduction of a fundamentally different moderator below the target for the complementary needs of certain fundamental physics experiments. To facilitate experiments…
▽ More
The development of the flat moderator concept at ESS recently opened up the possibility that a single flat moderator above the target could serve all the scattering instruments, that rely on high brightness. This would allow for the introduction of a fundamentally different moderator below the target for the complementary needs of certain fundamental physics experiments. To facilitate experiments depending on the total number of neutrons in a sizable beam, the option of a voluminous D2 moderator, in a large cross-section extraction guide is discussed and its neutronic performance is assessed.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Low dimensional neutron moderators for enhanced source brightness
Authors:
Ferenc Mezei,
Luca Zanini,
Alan Takibayev,
Konstantin Batkov,
Esben Klinkby,
Eric Pitcher,
Troels Schönfeldt
Abstract:
In a recent numerical optimization study we have found that liquid para-hydrogen coupled cold neutron moderators deliver 3 - 5 times higher cold neutron brightness at a spallation neutron source if they take the form of a flat, quasi 2-dimensional disc, in contrast to the conventional more voluminous shapes used by now. In the present paper we describe a simple theoretical explanation of this unex…
▽ More
In a recent numerical optimization study we have found that liquid para-hydrogen coupled cold neutron moderators deliver 3 - 5 times higher cold neutron brightness at a spallation neutron source if they take the form of a flat, quasi 2-dimensional disc, in contrast to the conventional more voluminous shapes used by now. In the present paper we describe a simple theoretical explanation of this unexpected behavior, which is based on the large difference in para-hydrogen between the values of the scattering mean free path for thermal neutrons (in the range of 1 cm) and its much larger equivalent for cold neutrons. This model leads to the conclusions that the optimal shape for high brightness para-hydrogen neutron moderators is the quasi 1-dimensional tube and these low dimensional moderators can also deliver much enhanced cold neutron brightness in fission reactor neutron sources, compared to much more voluminous liquid D2 or H2 moderators currently used. Neutronic simulation calculations confirm both of these theoretical conclusions.
△ Less
Submitted 11 November, 2013;
originally announced November 2013.
-
Space-Time Approach to Scattering from Many Body Systems
Authors:
R. Gaehler,
J. Felber,
F. Mezei,
R. Golub
Abstract:
We present scattering from many body systems in a new light. In place of the usual van Hove treatment, (applicable to a wide range of scattering processes using both photons and massive particles) based on plane waves, we calculate the scattering amplitude as a space-time integral over the scattering sample for an incident wave characterized by its correlation function which results from the sha…
▽ More
We present scattering from many body systems in a new light. In place of the usual van Hove treatment, (applicable to a wide range of scattering processes using both photons and massive particles) based on plane waves, we calculate the scattering amplitude as a space-time integral over the scattering sample for an incident wave characterized by its correlation function which results from the sha** of the wave field by the apparatus. Instrument resolution effects - seen as due to the loss of correlation caused by the path differences in the different arms of the instrument are automatically included and analytic forms of the resolution function for different instruments are obtained. The intersection of the moving correlation volumes (those regions where the correlation functions are significant) associated with the different elements of the apparatus determines the maximum correlation lengths (times) that can be observed in a sample, and hence, the momentum (energy) resolution of the measurement. This geometrical picture of moving correlation volumes derived by our technique shows how the interaction of the scatterer with the wave field shaped by the apparatus proceeds in space and time. Matching of the correlation volumes so as to maximize the intersection region yields a transparent, graphical method of instrument design. PACS: 03.65.Nk, 3.80 +r, 03.75, 61.12.B
△ Less
Submitted 16 December, 1997;
originally announced December 1997.