Skip to main content

Showing 1–27 of 27 results for author: Merlet, S

Searching in archive physics. Search in all archives.
.
  1. Separating the output ports of a Bragg interferometer via velocity selective transport

    Authors: Raphaël Piccon, Sumit Sarkar, Sébastien Merlet, Franck Pereira dos Santos

    Abstract: We report on the study of a detection scheme based on a Bloch separator in two-photon Bragg interferometers. We increase the spatial separation between the two output ports of the interferometer by selectively imparting 30 Bloch oscillations to one of them before their detection via time of flight. This method allows increasing the duration of the interferometer by reducing the time for discrimina… ▽ More

    Submitted 7 March, 2022; originally announced March 2022.

  2. A compact differential gravimeter at the quantum projection noise limit

    Authors: Camille Janvier, Vincent Ménoret, Sébastien Merlet, Arnaud Landragin, Franck Pereira Dos Santos, Bruno Desruelle

    Abstract: Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with t… ▽ More

    Submitted 10 January, 2022; originally announced January 2022.

  3. arXiv:2007.10291  [pdf, other

    physics.ins-det physics.app-ph physics.atom-ph physics.geo-ph

    Calibration of a superconducting gravimeter with an absolute atom gravimeter

    Authors: S. Merlet, P. Gillot, B. Cheng, R. Karcher, A. Imanaliev, L. Timmen, F. Pereira Dos Santos

    Abstract: We present a 27-days long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5~nm.s$^{-2}$. We investigate the impact of the duration of the measurement on the uncertainty in the determination of the correlation… ▽ More

    Submitted 15 February, 2021; v1 submitted 20 July, 2020; originally announced July 2020.

  4. arXiv:2007.04014  [pdf, other

    physics.atom-ph

    Technologies for the ELGAR large scale atom interferometer array

    Authors: B. Canuel, S. Abend, P. Amaro-Seoane, F. Badaracco, Q. Beaufils, A. Bertoldi, K. Bongs, P. Bouyer, C. Braxmaier, W. Chaibi, N. Christensen, F. Fitzek, G. Flouris, N. Gaaloul, S. Gaffet, C. L. Garrido Alzar, R. Geiger, S. Guellati-Khelifa, K. Hammerer, J. Harms, J. Hinderer, M. Holynski, J. Junca, S. Katsanevas, C. Klempt , et al. (34 additional authors not shown)

    Abstract: We proposed the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an array of atom gradiometers aimed at studying space-time and gravitation with the primary goal of observing gravitational waves (GWs) in the infrasound band with a peak strain sensitivity of $3.3 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz. In this paper we detail the main technological bricks of this… ▽ More

    Submitted 8 July, 2020; originally announced July 2020.

    Comments: This paper contains the technical aspects of the ELGAR facility. This content was originally included in arXiv:1911.03701 and will finally be published separately

  5. arXiv:2003.12516  [pdf, other

    physics.atom-ph physics.app-ph physics.ins-det quant-ph

    High-accuracy inertial measurements with cold-atom sensors

    Authors: Remi Geiger, Arnaud Landragin, Sébastien Merlet, Franck Pereira Dos Santos

    Abstract: The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review present… ▽ More

    Submitted 27 March, 2020; originally announced March 2020.

    Comments: Invited review article submitted to AVS quantum science, special topic on quantum sensing and metrology. Feedback is welcome

    Journal ref: AVS Quantum Sci. 2, 024702 (2020)

  6. Impact of direct digital synthesizer finite resolution on atom gravimeters

    Authors: R Karcher, Franck Pereira dos Santos, S Merlet

    Abstract: We report on the study of the impact of the finite resolution of the chirp rate applied on the frequency difference between the Raman lasers beamsplitters onto the phase of a free fall atom gravimeter. This chirp induces a phase shift that compensates the one due to gravity acceleration, allowing for its precise determination in terms of frequencies. In practice, it is most often generated by a di… ▽ More

    Submitted 21 January, 2020; originally announced January 2020.

    Journal ref: Phys. Rev. A 101, 043622 (2020)

  7. arXiv:1911.03701  [pdf, other

    physics.atom-ph gr-qc

    ELGAR -- a European Laboratory for Gravitation and Atom-interferometric Research

    Authors: B. Canuel, S. Abend, P. Amaro-Seoane, F. Badaracco, Q. Beaufils, A. Bertoldi, K. Bongs, P. Bouyer, C. Braxmaier, W. Chaibi, N. Christensen, F. Fitzek, G. Flouris, N. Gaaloul, S. Gaffet, C. L. Garrido Alzar, R. Geiger, S. Guellati-Khelifa, K. Hammerer, J. Harms, J. Hinderer, J. Junca, S. Katsanevas, C. Klempt, C. Kozanitis , et al. (33 additional authors not shown)

    Abstract: Gravitational Waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportu… ▽ More

    Submitted 9 November, 2019; originally announced November 2019.

    Journal ref: Class. Quantum Grav. 37 225017 (2020)

  8. arXiv:1908.10058  [pdf, other

    astro-ph.IM physics.atom-ph

    A prototype industrial laser system for cold atom inertial sensing in space

    Authors: Romain Caldani, Sébastien Merlet, Franck Pereira Dos Santos, Guillaume Stern, Anne-Sophie Martin, Bruno Desruelle, Vincent Ménoret

    Abstract: We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor current… ▽ More

    Submitted 27 August, 2019; originally announced August 2019.

  9. Simultaneous accurate determination of both gravity and its vertical gradient

    Authors: R. Caldani, K Weng, S. Merlet, Franck Pereira dos Santos

    Abstract: We present a method for the accurate measurements of both the gravity acceleration and its vertical gradient using a dual atom interferometer, in principle free from any uncertainty related to the absolute or relative positions of the two atomic samples. The method relies on the use of a dual lock technique, which stirs simultaneously the chirp rate applied to the frequency difference between the… ▽ More

    Submitted 21 December, 2018; originally announced December 2018.

    Journal ref: Phys. Rev. A 99, 033601 (2019)

  10. Improving the accuracy of atom interferometers with ultracold sources

    Authors: R Karcher, A Imanaliev, S. Merlet, Franck Pereira dos Santos

    Abstract: We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm/s 2 statistical uncertainties in a so-far unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beam spli… ▽ More

    Submitted 13 April, 2018; originally announced April 2018.

  11. Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors

    Authors: M. Langlois, R. Caldani, A. Trimeche, S. Merlet, Franck Pereira dos Santos

    Abstract: We perform the experimental demonstration of the method proposed in [Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free-falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources, and use… ▽ More

    Submitted 6 December, 2017; originally announced December 2017.

    Journal ref: Physical Review A, American Physical Society, 2017, 96 (5)

  12. Active Control of Laser Wavefronts in Atom Interferometers

    Authors: Azer Trimeche, Mehdi Langlois, Sébastien Merlet, Franck Pereira dos Santos

    Abstract: Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of best cold atom interferometers based on two-photon laser beam splitters, and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in fu… ▽ More

    Submitted 24 April, 2017; originally announced April 2017.

    Journal ref: Physical Review Applied, American Physical Society, 2017, 7

  13. Coherent population trap** in a Raman atom interferometer

    Authors: Bing Cheng, Pierre Gillot, Sébastien Merlet, Franck Pereira dos Santos

    Abstract: We investigate the effect of coherent population trap** (CPT) in an atom inter-ferometer gravimeter based on the use of stimulated Raman transitions. We find that CPT leads to significant phase shifts, of order of a few mrad, which may compromise the accuracy of inertial measurements. We show that this effect is rejected by the k-reversal technique, which consists in averaging inertial measureme… ▽ More

    Submitted 9 June, 2016; originally announced June 2016.

  14. Metrology with Atom Interferometry: Inertial Sensors from Laboratory to Field Applications

    Authors: Bess Fang, Indranil Dutta, Pierre Gillot, Denis Savoie, Jean Lautier, Bing Cheng, Carlos L Garrido Alzar, Remi Geiger, Sebastien Merlet, Franck Pereira Dos Santos, Arnaud Landragin

    Abstract: Developments in atom interferometry have led to atomic inertial sensors with extremely high sensitivity. Their performances are for the moment limited by the ground vibrations, the impact of which is exacerbated by the sequential operation, resulting in aliasing and dead time. We discuss several experiments performed at LNE-SYRTE in order to reduce these problems and achieve the intrinsic limit of… ▽ More

    Submitted 22 January, 2016; originally announced January 2016.

    Comments: 7 pages, 5 figures

    Journal ref: Journal of Physics: Conference Series 723 (2016) 012049

  15. Influence of chir** the Raman lasers in an atom gravimeter: phase shifts due to the Raman light shift and to the finite speed of light

    Authors: B. Cheng, P. Gillot, S. Merlet, F. Pereira Dos Santos

    Abstract: We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the resonance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the tw… ▽ More

    Submitted 16 October, 2015; v1 submitted 10 June, 2015; originally announced June 2015.

  16. arXiv:1410.0050  [pdf, ps, other

    physics.atom-ph physics.geo-ph physics.ins-det quant-ph

    Hybridizing matter-wave and classical accelerometers

    Authors: Jean Lautier, Laurent Volodimer, Thomas Hardin, Sebastien Merlet, Michel Lours, Franck Pereira Dos Santos, Arnaud Landragin

    Abstract: We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performances without any isolation platform. Second, a servo-lock of the DC com… ▽ More

    Submitted 6 October, 2014; v1 submitted 30 September, 2014; originally announced October 2014.

    Journal ref: Appl. Phys. Lett. 105, 144102 (2014)

  17. Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection

    Authors: Tristan Farah, Pierre Gillot, Bing Cheng, Arnaud Landragin, Sébastien Merlet, Franck Pereira Dos Santos

    Abstract: We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trap** parameters. In particular, we s… ▽ More

    Submitted 23 June, 2014; originally announced June 2014.

  18. A simple laser system for atom interferometry

    Authors: Sébastien Merlet, Laurent Volodimer, Michel Lours, Franck Pereira Dos Santos

    Abstract: We present here a simple laser system for a laser cooled atom interferometer, where all functions (laser cooling, interferometry and detection) are realized using only two extended cavity laser diodes, amplified by a common tapered amplifier. One laser is locked by frequency modulation transfer spectroscopy, the other being phase locked with an offset frequency determined by an Field-Programmable… ▽ More

    Submitted 23 June, 2014; originally announced June 2014.

  19. arXiv:1406.5134  [pdf, ps, other

    physics.atom-ph physics.geo-ph physics.ins-det

    Stability comparison of two absolute gravimeters: optical versus atomic interferometers

    Authors: Pierre Gillot, Olivier Francis, Arnaud Landragin, Franck Pereira Dos Santos, Sébastien Merlet

    Abstract: We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at… ▽ More

    Submitted 19 June, 2014; originally announced June 2014.

    Comments: 6 pages

    Journal ref: Metrologia 51, 5 (2014) L15

  20. arXiv:1404.6722  [pdf

    physics.atom-ph physics.ins-det

    Underground operation at best sensitivity of the mobile LNE-SYRTE Cold Atom Gravimeter

    Authors: Tristan Farah, Christine Guerlin, Arnaud Landragin, Philippe Bouyer, Stéphane Gaffet, Franck Pereira Dos Santos, Sébastien Merlet

    Abstract: Low noise underground environments offer conditions allowing to assess ultimate performance of high sensitivity sensors such as accelerometers, gyrometers, seismometers... Such facilities are for instance ideal for observing the tiny signals of interest for geophysical studies. Laboratoire Souterrain à Bas Bruit (LSBB) in which we have installed our cold atom gravimeter, provides such an environme… ▽ More

    Submitted 27 April, 2014; originally announced April 2014.

  21. arXiv:1105.2173  [pdf, other

    physics.atom-ph physics.geo-ph

    Perturbations of the local gravity field due to mass distribution on precise measuring instruments: a numerical method applied to a cold atom gravimeter

    Authors: G. D'Agostino, S. Merlet, A. Landragin, F. Pereira Dos Santos

    Abstract: We present a numerical method, based on a FEM simulation, for the determination of the gravitational field generated by massive objects, whatever geometry and space mass density they have. The method was applied for the determination of the self gravity effect of an absolute cold atom gravimeter which aims at a relative uncertainty of 10-9. The deduced bias, calculated with a perturbative treatmen… ▽ More

    Submitted 11 May, 2011; originally announced May 2011.

    Comments: 12 pages, 7 figures

  22. arXiv:1008.2884  [pdf, other

    physics.atom-ph physics.geo-ph

    Comparison of 3 absolute gravimeters based on different methods for the e-MASS project

    Authors: A. Louchet-Chauvet, S. Merlet, Q. Bodart, A. Landragin, F. Pereira Dos Santos, H. Baumann, G. D'Agostino, C. Origlia

    Abstract: We report on the comparison between three absolute gravimeters that took place in April 2010 at Laboratoire National de Métrologie et d'Essais. The three instruments (FG5#209 from METAS, Switzerland, IMGC-02 from INRIM, Italy, and CAG from LNE-SYRTE, France) rely on different methods: optical and atomic interferometry. We discuss their differences as well as their similarities. We compare their me… ▽ More

    Submitted 23 November, 2010; v1 submitted 17 August, 2010; originally announced August 2010.

    Journal ref: IEEE Transactions on Instrumentation and Measurement 60, 2527 (2011)

  23. arXiv:1005.0357  [pdf, ps, other

    physics.atom-ph physics.geo-ph

    Comparison between two mobile absolute gravimeters: optical versus atomic interferometers

    Authors: S. Merlet, Q. Bodart, N. Malossi, A. Landragin, F. Pereira Dos Santos, O. Gitlein, L. Timmen

    Abstract: We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral compariso… ▽ More

    Submitted 28 June, 2010; v1 submitted 3 May, 2010; originally announced May 2010.

    Journal ref: Metrologia 47 (2010) L9-L11

  24. arXiv:1004.5290  [pdf, ps, other

    physics.atom-ph

    A cold atom pyramidal gravimeter with a single laser beam

    Authors: Quentin Bodart, Sébastien Merlet, Nicola Malossi, Franck Pereira Dos Santos, Philippe Bouyer, Arnaud Landragin

    Abstract: We demonstrate a scheme for realizing a compact cold atom gravimeter. The use of a hollow pyramidal configuration allows to achieve all functions: trap**, interferometer and detection with a unique laser beam leading to a drastic reduction in complexity and volume. In particular, we demonstrate a relative sensitivity to acceleration of gravity (g) of 1.7 x 10-7 at one second, with a moderate las… ▽ More

    Submitted 29 April, 2010; originally announced April 2010.

  25. Double diffraction in an atomic gravimeter

    Authors: Nicola Malossi, Quentin Bodart, Sébastien Merlet, Thomas Lévèque, Arnaud Landragin, Franck Pereira Dos Santos

    Abstract: We demonstrate the realization of a new scheme for cold atom gravimetry based on the use of double diffraction beamsplitters recently demonstrated in \cite{Leveque}, where the use of two retro-reflected Raman beams allows symmetric diffraction in $\pm \hbar k_{eff}$ momenta. Though in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneousl… ▽ More

    Submitted 21 November, 2009; v1 submitted 1 September, 2009; originally announced September 2009.

  26. Operating an atom interferometer beyond its linear range

    Authors: Sébastien Merlet, J. Le Gouët, Quentin Bodart, Andre Clairon, Arnaud Landragin, Franck Pereira Dos Santos, Pierre Rouchon

    Abstract: In this paper, we show that an atom interferometer inertial sensor, when associated to the auxiliary measurement of external vibrations, can be operated beyond its linear range and still keep a high acceleration sensitivity. We propose and compare two measurement procedures (fringe fitting and nonlinear lock) that can be used to extract the mean phase of the interferometer when the interferomete… ▽ More

    Submitted 1 June, 2008; originally announced June 2008.

    Comments: 20 pages, 8 figures

    Journal ref: Metrologia 46, 1 (2009) 87-94

  27. Limits to the sensitivity of a low noise compact atomic gravimeter

    Authors: J. Le Gouët, Tanja Mehlstäubler, Jaewan Kim, Sébastien Merlet, Andre Clairon, Arnaud Landragin, Franck Pereira Dos Santos

    Abstract: A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of $1.4\times 10^{-8}$g at 1s. This result relies on the combination of a low phase noise laser system, efficient de… ▽ More

    Submitted 8 January, 2008; originally announced January 2008.

    Comments: 30 pages, 14 figures

    Journal ref: Applied Physics B: Lasers and Optics 92, 2 (2008) 133-144