-
Status of the production of GEM chambers for the CMS experiment at Large Hadron Collider
Authors:
L. Benussi,
S. Bianco,
R. Campagnola,
M. Caponero,
S. Colafranceschi,
S. Meola,
E. Paoletti,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
R. Tesauro
Abstract:
The High Luminosity LHC phase includes an upgrade to the muon stations for the CMS Experiment. CMS trigger and muon identification performance will be crucial, and it is, therefore, necessary to install new GEM stations to extend acceptance in the high-η region. An explanation of the quality control test and an update on the status of production will be provided.
The High Luminosity LHC phase includes an upgrade to the muon stations for the CMS Experiment. CMS trigger and muon identification performance will be crucial, and it is, therefore, necessary to install new GEM stations to extend acceptance in the high-η region. An explanation of the quality control test and an update on the status of production will be provided.
△ Less
Submitted 28 March, 2024;
originally announced April 2024.
-
Machine Learning based tool for CMS RPC currents quality monitoring
Authors:
E. Shumka,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
K. Mota Amarilo,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov
, et al. (83 additional authors not shown)
Abstract:
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly m…
▽ More
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly monitored and the detector is regularly maintained to ensure stable operation. The main monitorable characteristics are dark current, efficiency for muon detection, noise rate etc. Herein we describe an automated tool for CMS RPC current monitoring which uses Machine Learning techniques. We further elaborate on the dedicated generalized linear model proposed already and add autoencoder models for self-consistent predictions as well as hybrid models to allow for RPC current predictions in a distant future.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
RPC based tracking system at CERN GIF++ facility
Authors:
K. Mota Amarilo,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov
, et al. (83 additional authors not shown)
Abstract:
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system…
▽ More
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Design of a Resistive Plate Chamber using additive manufacturing
Authors:
L. Benussi,
S. Bianco,
R. Campagnola,
M. Caponero,
S. Colafranceschi,
H. Gebremedhin,
J. Hess,
J. Horsley,
M. Landis,
S. Meola,
D. Nester,
L. Passamonti,
L. Peachey-Stoner,
R. Peachey-Stoner,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
L. Stutzman,
R. Tezazu
Abstract:
Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and construction costs, the reproducibility/modularity of the products, and the reduced assembly time. During the first phase of this research, after determining the most suit…
▽ More
Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and construction costs, the reproducibility/modularity of the products, and the reduced assembly time. During the first phase of this research, after determining the most suitable material, we produced 10 examples of detectors.
△ Less
Submitted 26 October, 2022;
originally announced October 2022.
-
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
Authors:
A. Samalan,
M. Tytgat,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. DaCosta,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal,
A. Cabrera
, et al. (86 additional authors not shown)
Abstract:
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen…
▽ More
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
△ Less
Submitted 2 November, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
Towards a two-dimensional readout of the improved CMS Resistive Plate Chamber with a new front-end electronics
Authors:
Sabino Meola
Abstract:
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the Large Hadron Collider, therefore an improved RPC design has been proposed with a new front-end electronics to sustain a higher rate capability and better time re…
▽ More
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the Large Hadron Collider, therefore an improved RPC design has been proposed with a new front-end electronics to sustain a higher rate capability and better time resolution. A new technology is used in the front-end electronics resulting in very low achievable thresholds of the order of several fC. Crucial in the design of the improved RPC is the capability of a two-dimensional readout in order to improve the spatial resolution, mainly motivated by trigger requirements. In this work, the first performance results towards this two-dimensional readout are presented, based on data taken on a real-size prototype chamber with two embedded orthogonal readout strips. Furthermore, dedicated studies of the muon cluster size as a function of the graphite resistivity are discussed.
△ Less
Submitted 31 May, 2020;
originally announced June 2020.
-
CMS RPC Background -- Studies and Measurements
Authors:
R. Hadjiiska,
A. Samalan,
M. Tytgat,
N. Zaganidis,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. Da Costa,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal
, et al. (84 additional authors not shown)
Abstract:
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd…
▽ More
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.
△ Less
Submitted 13 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
High Rate RPC detector for LHC
Authors:
F. Lagarde,
A. Fagot,
M. Gul,
C. Roskas,
M. Tytgat,
N. Zaganidis,
S. Fonseca De Souza,
A. Santoro,
F. Torres Da Silva De Araujo,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
D. Han,
W. Yi,
C. Avila,
A. Cabrera
, et al. (77 additional authors not shown)
Abstract:
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The…
▽ More
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
R&D towards the CMS RPC Phase-2 upgrade
Authors:
A. Fagot,
A. Cimmino,
S. Crucy,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Aly,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
V. Bhatnagar
, et al. (71 additional authors not shown)
Abstract:
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle…
▽ More
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.
△ Less
Submitted 14 June, 2016;
originally announced June 2016.
-
High rate, fast timing Glass RPC for the high η CMS muon detectors
Authors:
F. Lagarde,
M. Gouzevitch,
I. Laktineh,
V. Buridon,
X. Chen,
C. Combaret,
A. Eynard,
L. Germani,
G. Grenier,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
W. Tromeuraa,
Y. Wang,
A. Gongab,
N. Moreau,
C. de la Taille,
F. Dulucqac,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat
, et al. (86 additional authors not shown)
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high $η$ muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.
△ Less
Submitted 22 July, 2016; v1 submitted 4 June, 2016;
originally announced June 2016.
-
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment
Authors:
M. Shopova,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
G. Sultanov,
M. Rodozov,
S. Stoykova,
Y. Assran,
A. Sayed,
A. Radi,
S. Aly,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
A. Cimmino
, et al. (71 additional authors not shown)
Abstract:
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L…
▽ More
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.
△ Less
Submitted 22 May, 2016;
originally announced May 2016.
-
Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope
Authors:
K. S. Lee,
S. Choi,
B. S. Hong,
M. Jo,
J. W. Kang,
M. Kang,
H. Kim,
K. Lee,
S. K. Parka,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Ali,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese
, et al. (71 additional authors not shown)
Abstract:
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muon…
▽ More
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam line to examine the rate capabilities of the prototype RPCs. In contrast to the case of the four-gap RPCs, we found the relatively high threshold was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-η endcap RPCs planned for future phase-II LHC runs.
△ Less
Submitted 4 May, 2016; v1 submitted 2 May, 2016;
originally announced May 2016.
-
Performance of the gas gain monitoring system of the CMS RPC muon detector
Authors:
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
Y. Ban,
J. Cai,
Q. Li,
S. Liu,
S. Qian,
D. Wang,
Z. Xu,
F. Zhang,
Y. Choi,
D. Kim,
S. Choi,
B. Hong,
J. W. Kang,
M. Kang,
J. H. Kwon,
K. S. Lee,
S. K. Park
, et al. (60 additional authors not shown)
Abstract:
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
△ Less
Submitted 27 December, 2014;
originally announced December 2014.