-
Electromagnetic calorimeter time measurement applications in the SND physics analysis
Authors:
N. A. Melnikova,
M. N. Achasov,
A. A. Botov,
V. P. Druzhinin,
L. V. Kardapoltsev,
A. A. Korol,
D. P. Kovrizhin,
S. I. Serednyakov,
I. K. Surin
Abstract:
The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a hodoscopic electromagnetic calorimeter (EMC) with three layers of NaI(Tl) counters. The EMC signal sha** and digitizing electronics based on FADC allow to obtain bo…
▽ More
The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a hodoscopic electromagnetic calorimeter (EMC) with three layers of NaI(Tl) counters. The EMC signal sha** and digitizing electronics based on FADC allow to obtain both the signal amplitude and the arrival time. We describe the EMC signal processing and how the EMC measured time is applied in event reconstruction and physics analysis.
△ Less
Submitted 5 May, 2023;
originally announced May 2023.
-
SND electromagnetic calorimeter time measurement and its applications
Authors:
M. N. Achasov,
A. G. Bogdanchikov,
V. P. Druzhinin,
A. A. Korol,
D. P. Kovrizhin,
N. A. Melnikova,
S. I. Serednyakov,
I. K. Surin,
A. I. Tekut'ev,
Yu. V. Usov,
V. V. Zhulanov
Abstract:
The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measureme…
▽ More
The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer hodoscopic electromagnetic calorimeter (EMC) based on NaI(Tl) counters. Until the recent EMC spectrometric channel upgrade, only the energy deposition measurement in counters was possible. A new EMC signal sha** and digitizing electronics based on FADC allows us to obtain also the event time structure. The new electronics and supporting software, including digital signal processing algorithms, are used for data taking in the ongoing experiment. We discuss the amplitude and time extraction algorithms, the new system performance on experimental events and physical analysis applications.
△ Less
Submitted 2 June, 2020; v1 submitted 14 May, 2020;
originally announced May 2020.
-
Geometric calibration of the SND detector electromagnetic calorimeter
Authors:
A. A. Korol,
N. A. Melnikova
Abstract:
This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector which is taking data at the VEPP-2000 e^{+}e^{-}collider (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position.…
▽ More
This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector which is taking data at the VEPP-2000 e^{+}e^{-}collider (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position. The parameter values are determined by minimizing a χ^{2} function using the difference between particle directions reconstructed in these two subdetectors for e^{+}e^{-}\rightarrow e^{+}e^{-} scattering events. The results of the calibration applied to data and MC simulation fit the model well and give an improvement in particle reconstruction. They are used in data reconstruction and MC simulation.
△ Less
Submitted 16 November, 2016; v1 submitted 2 June, 2016;
originally announced June 2016.