-
Second gadolinium loading to Super-Kamiokande
Authors:
K. Abe,
C. Bronner,
Y. Hayato,
K. Hiraide,
K. Hosokawa,
K. Ieki,
M. Ikeda,
J. Kameda,
Y. Kanemura,
R. Kaneshima,
Y. Kashiwagi,
Y. Kataoka,
S. Miki,
S. Mine,
M. Miura,
S. Moriyama,
Y. Nakano,
M. Nakahata,
S. Nakayama,
Y. Noguchi,
K. Sato,
H. Sekiya,
H. Shiba,
K. Shimizu,
M. Shiozawa
, et al. (225 additional authors not shown)
Abstract:
The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50\%. To further increase the Gd neutron capture efficiency to 75\%, 26.1 tons of $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was do…
▽ More
The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50\%. To further increase the Gd neutron capture efficiency to 75\%, 26.1 tons of $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was doubled compared to the first loading, the capacity of the powder dissolving system was doubled. We also developed new batches of gadolinium sulfate with even further reduced radioactive impurities. In addition, a more efficient screening method was devised and implemented to evaluate these new batches of $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$. Following the second loading, the Gd concentration in SK was measured to be $333.5\pm2.5$ ppm via an Atomic Absorption Spectrometer (AAS). From the mean neutron capture time constant of neutrons from an Am/Be calibration source, the Gd concentration was independently measured to be 332.7 $\pm$ 6.8(sys.) $\pm$ 1.1(stat.) ppm, consistent with the AAS result. Furthermore, during the loading the Gd concentration was monitored continually using the capture time constant of each spallation neutron produced by cosmic-ray muons,and the final neutron capture efficiency was shown to become 1.5 times higher than that of the first loaded phase, as expected.
△ Less
Submitted 18 June, 2024; v1 submitted 12 March, 2024;
originally announced March 2024.
-
Ultra-Low Background Germanium Assay at the Boulby Underground Laboratory
Authors:
P. R. Scovell,
E. Meehan,
S. M. Paling,
M. Thiesse,
X. Liu,
C. Ghag,
M. Ginsz,
P. Quirin,
D. Ralet
Abstract:
As we move to an era where next generation low-background particle physics experiments begin to be designed and constructed, the ability to assay materials with high sensitivity and at speed with a variety of techniques will be key. This paper describes the Mirion Technologies (Canberra) specialty ultra-low background detectors installed and commissioned at the Boulby Underground Laboratory betwee…
▽ More
As we move to an era where next generation low-background particle physics experiments begin to be designed and constructed, the ability to assay materials with high sensitivity and at speed with a variety of techniques will be key. This paper describes the Mirion Technologies (Canberra) specialty ultra-low background detectors installed and commissioned at the Boulby Underground Laboratory between 2017 and 2021. The low background levels of the detectors combine with low background shielding and a radon-reduced dry nitrogen purge system to give sensitivity approaching the best in the world without the need for intricate shielding solutions. For an optimised sample geometry, run for 100 days, it would be possible to reach close to 10 $μ$Bq/kg ($10^{-12}$ g/g) for background isotopes of interest in neutrinoless double-beta decay.
△ Less
Submitted 7 August, 2023;
originally announced August 2023.
-
Development of Ultra-pure Gadolinium Sulfate for the Super-Kamiokande Gadolinium Project
Authors:
K. Hosokawa,
M. Ikeda,
T. Okada,
H. Sekiya,
P. Fernandez,
L. Labarga,
I. Bandac,
J. Perez,
S. Ito,
M. Harada,
Y. Koshio,
M. D. Thiesse,
L. F. Thompson,
P. R. Scovell,
E. Meehan,
K. Ichimura,
Y. Kishimoto,
Y. Nakajima,
M. R. Vagins,
H. Ito,
Y. Takaku,
Y. Tanaka,
Y. Yamaguchi
Abstract:
This paper reports the development and detailed properties of about 13 tons of gadolinium sulfate octahydrate, $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, which has been dissolved into Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ on DSNB searches and solar neutrino observation and confirm the need to reduce radioa…
▽ More
This paper reports the development and detailed properties of about 13 tons of gadolinium sulfate octahydrate, $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, which has been dissolved into Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ on DSNB searches and solar neutrino observation and confirm the need to reduce radioactive and fluorescent impurities by about three orders of magnitude from commercially available high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$. In order to produce ultra-high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, we have developed a method to remove impurities from gadolinium oxide, Gd$_2$O$_3$, consisting of acid dissolution, solvent extraction, and pH control processes, followed by a high-purity sulfation process. All of the produced ultra-high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ is assayed by ICP-MS and HPGe detectors to evaluate its quality. Because of the long measurement time of HPGe detectors, we have employed several underground laboratories for making parallel measurements including LSC in Spain, Boulby in the UK, and Kamioka in Japan. In the first half of production, the measured batch purities were found to be consistent with the specifications. However,in the latter half, the $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ contained one order of magnitude more $^{228}$Ra than the budgeted mean contamination. This was correlated with the corresponding characteristics of the raw material Gd$_2$O$_3$, in which an intrinsically large contamination was present. Based on their modest impact on SK physics, they were nevertheless introduced into the detector. To reduce $^{228}$Ra for the next stage of Gd loading to SK, a new process has been successfully establised.
△ Less
Submitted 13 September, 2022;
originally announced September 2022.
-
Low Background Gamma Spectroscopy at the Boulby Underground Laboratory
Authors:
P. R. Scovell,
E. Meehan,
H. M. Araújo,
J. Dobson,
C. Ghag,
H. Kraus,
V. A. Kudryavtsev,
X-. R. Liu,
P. Majewski,
S. M. Paling,
R. M. Preece,
R. Saakyan,
A. Tomás,
C. Toth,
L. M. Yeoman
Abstract:
The Boulby Underground Germanium Suite (BUGS) comprises three low background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three types of detector to facilitate a high-sensitivity, high-throughput radioassay programme to support the development of rare-event search experiments. A Broad Ene…
▽ More
The Boulby Underground Germanium Suite (BUGS) comprises three low background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three types of detector to facilitate a high-sensitivity, high-throughput radioassay programme to support the development of rare-event search experiments. A Broad Energy Germanium (BEGe) detector delivers sensitivity to low-energy gamma-rays such as those emitted by 210Pb and 234Th. A Small Anode Germanium (SAGe) well-type detector is employed for efficient screening of small samples. Finally, a standard p-type coaxial detector provides fast screening of standard samples. This paper presents the steps used to characterise the performance of these detectors for a variety of sample geometries, including the corrections applied to account for cascade summing effects. For low-density materials, BUGS is able to radio-assay to specific activities down to 3.6 mBq/kg for 234Th and 6.6 mBq/kg for 210Pb both of which have uncovered some significant equilibrium breaks in the 238U chain. In denser materials, where gamma-ray self-absorption increases, sensitivity is demonstrated to specific activities of 0.9 mBq/kg for 226Ra, 1.1 mBq/kg for 228 Ra, 0.3 mBq/kg for 224Ra, and 8.6 mBq/kg for 40K with all upper limits at a 90% confidence level. These meet the requirements of most screening campaigns presently under way for rare-event search experiments, such as the LUX-ZEPLIN (LZ) dark matter experiment. We also highlight the ability of the BEGe detector to probe the X-ray fluorescence region which can be important to identify the presence of radioisotopes associated with neutron production; this is of particular relevance in experiments sensitive to nuclear recoils.
△ Less
Submitted 15 November, 2017; v1 submitted 21 August, 2017;
originally announced August 2017.