Skip to main content

Showing 1–50 of 98 results for author: McKinsey, D

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.12874  [pdf, other

    physics.ins-det hep-ex

    The Design, Implementation, and Performance of the LZ Calibration Systems

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (179 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e… ▽ More

    Submitted 20 June, 2024; v1 submitted 2 May, 2024; originally announced June 2024.

  2. arXiv:2405.14732  [pdf, other

    physics.ins-det hep-ex

    The Data Acquisition System of the LZ Dark Matter Detector: FADR

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (190 additional authors not shown)

    Abstract: The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.… ▽ More

    Submitted 23 May, 2024; originally announced May 2024.

    Comments: 18 pages, 24 figures

  3. arXiv:2307.11877  [pdf, other

    physics.ins-det hep-ex

    Applying Superfluid Helium to Light Dark Matter Searches: Demonstration of the HeRALD Detector Concept

    Authors: R. Anthony-Petersen, A. Biekert, C. L. Chang, Y. Chang, L. Chaplinsky, A. Dushkin, C. W. Fink, M. Garcia-Sciveres, W. Guo, S. A. Hertel, X. Li, J. Lin, R. Mahapatra, W. Matava, D. N. McKinsey, D. Z. Osterman, P. K. Patel, B. Penning, H. D. Pinckney, M. Platt, M. Pyle, Y. Qi, M. Reed, G. R. C Rischbieter, R. K. Romani , et al. (11 additional authors not shown)

    Abstract: The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (e.g. scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD… ▽ More

    Submitted 21 July, 2023; originally announced July 2023.

    Comments: 14 pages, 9 figures

  4. arXiv:2302.03869  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter

    Authors: A. Biekert, C. Chang, L. Chaplinsky, C. W. Fink, W. D. Frey, M. Garcia-Sciveres, W. Guo, S. A. Hertel, X. Li, J. Lin, M. Lisovenko, R. Mahapatra, D. N. McKinsey, S. Mehrotra, N. Mirabolfathi, P. K. Patel, B. Penning, H. D. Pinckney, M. Reed, R. K. Romani, B. Sadoulet, R. J. Smith, P. Sorensen, B. Suerfu, A. Suzuki , et al. (5 additional authors not shown)

    Abstract: A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutr… ▽ More

    Submitted 7 February, 2023; originally announced February 2023.

    Comments: 11 pages, 20 figures

  5. arXiv:2211.17120  [pdf, other

    hep-ex physics.ins-det

    Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, J. Bang, J. W. Bargemann, A. Baxter, K. Beattie, P. Beltrame, E. P. Bernard, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger, B. Boxer , et al. (178 additional authors not shown)

    Abstract: The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet… ▽ More

    Submitted 17 July, 2023; v1 submitted 30 November, 2022; originally announced November 2022.

    Comments: 25 pages, 15 figures

    Journal ref: Phys. Rev. D 108, 012010 (2023)

  6. arXiv:2211.10726  [pdf, other

    hep-ex astro-ph.IM nucl-ex physics.ins-det

    A Review of NEST Models, and Their Application to Improvement of Particle Identification in Liquid Xenon Experiments

    Authors: M. Szydagis, J. Balajthy, G. A. Block, J. P. Brodsky, E. Brown, J. E. Cutter, S. J. Farrell, J. Huang, E. S. Kozlova, C. S. Liebenthal, D. N. McKinsey, K. McMichael, M. Mooney, J. Mueller, K. Ni, G. R. C. Rischbieter, M. Tripathi, C. D. Tunnell, V. Velan, M. D. Wyman, Z. Zhao, M. Zhong

    Abstract: This paper discusses microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event physics searches, and describes experimental observables useful to understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique, or NEST, which is a toolk… ▽ More

    Submitted 14 December, 2023; v1 submitted 19 November, 2022; originally announced November 2022.

    Comments: 26 Pages, 6 Tables, 15 Figures, 18 Equations, and 156 References

  7. arXiv:2210.05859  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Improved Dark Matter Search Sensitivity Resulting from LUX Low-Energy Nuclear Recoil Calibration

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, J. Bang, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, A. Fan, S. Fiorucci, R. J. Gaitskell, C. Ghag , et al. (72 additional authors not shown)

    Abstract: Dual-phase xenon time projection chamber (TPC) detectors have demonstrated superior search sensitivities to dark matter over a wide range of particle masses. To extend their sensitivity to include low-mass dark matter interactions, it is critical to characterize both the light and charge responses of liquid xenon to sub-keV nuclear recoils. In this work, we report a new nuclear recoil calibration… ▽ More

    Submitted 14 October, 2022; v1 submitted 11 October, 2022; originally announced October 2022.

  8. arXiv:2209.05435  [pdf, other

    physics.ins-det

    Thermodynamic Stability of Xenon-Doped Liquid Argon Detectors

    Authors: Ethan P. Bernard, Eli Mizrachi, James Kingston, **gke Xu, Sergey V. Pereverzev, Teal Pershing, Ryan Smith, Charles G. Prior, Nathaniel S. Bowden, Adam Bernstein, Carter R. Hall, Emilija Pantic, Mani Tripathi, Daniel N. McKinsey, Phillip S. Barbeau

    Abstract: Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or… ▽ More

    Submitted 12 September, 2022; originally announced September 2022.

    Comments: 14 pages, 8 figures

    Report number: LLNL-JRNL-839368

  9. arXiv:2208.02790  [pdf, ps, other

    physics.ins-det cond-mat.supr-con

    A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning

    Authors: Robin Anthony-Petersen, Andreas Biekert, Raymond Bunker, Clarence L. Chang, Yen-Yung Chang, Luke Chaplinsky, Eleanor Fascione, Caleb W. Fink, Maurice Garcia-Sciveres, Richard Germond, Wei Guo, Scott A. Hertel, Ziqing Hong, Noah Kurinsky, Xinran Li, Junsong Lin, Marharyta Lisovenko, Rupak Mahapatra, Adam Mayer, Daniel McKinsey, Siddhant Mehrotra, Nader Mirabolfathi, Brian Neblosky, William A. Page, Pratyush K. Patel , et al. (21 additional authors not shown)

    Abstract: The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called "quasiparticle poisoning." Recently, a superconductor with one of the lowest average quasiparticle densities ever measured exhibited quasiparticles primarily produced in bursts which decreased in rate wi… ▽ More

    Submitted 4 August, 2022; originally announced August 2022.

    Comments: 13 pages, 6 figures. W. A. Page and R. K. Romani contributed equally to this work. Correspondence should be addressed to R. K. Romani

  10. arXiv:2206.07854  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Study of dielectric breakdown in liquid xenon with the XeBrA experiment

    Authors: J. Watson, I. Olcina, J. Soria, D. N. McKinsey, S. Kravitz, E. E. Deck, E. P. Bernard, L. Tvrznikova, W. L. Waldron, Q. Riffard, K. O'Sullivan

    Abstract: Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment.… ▽ More

    Submitted 31 October, 2022; v1 submitted 15 June, 2022; originally announced June 2022.

    Comments: 18 pages, 16 figures; A typo in the author list was corrected; Corrections to the body text were made and supplementary material was added

    Journal ref: Review of Scientific Instruments 94, 015112 (2023)

  11. arXiv:2203.04896  [pdf, other

    physics.ins-det nucl-ex

    A backing detector for order-keV neutrons

    Authors: A. Biekert, L. Chaplinsky, C. W. Fink, M. Garcia-Sciveres, W. C. Gillis, W. Guo, S. A. Hertel, G. Heuermann, X. Li, J. Lin, R. Mahapatra, D. N. McKinsey, P. K. Patel, B. Penning, H. D. Pinckney, M. Platt, M. Pyle, R. K. Romani, A. Serafin, R. J. Smith, B. Suerfu, V. Velan, G. Wang, Y. Wang, S. L. Watkins , et al. (1 additional authors not shown)

    Abstract: We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scatte… ▽ More

    Submitted 9 March, 2022; originally announced March 2022.

    Comments: 25 pages, 14 figures, and 2 tables

  12. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  13. arXiv:2201.05734  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, J. Bang, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, N. Carrara, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, J. Ernst, A. Fan, S. Fiorucci , et al. (75 additional authors not shown)

    Abstract: We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations betwe… ▽ More

    Submitted 17 October, 2022; v1 submitted 14 January, 2022; originally announced January 2022.

    Journal ref: Phys. Rev. D 106 (2022), 072009

  14. arXiv:2110.01537  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

    Authors: A. Avasthi, T. W. Bowyer, C. Bray, T. Brunner, N. Catarineu, E. Church, R. Guenette, S. J. Haselschwardt, J. C. Hayes, M. Heffner, S. A. Hertel, P. H. Humble, A. Jamil, S. Kim, R. F. Lang, K. G. Leach, B. G. Lenardo, W. H. Lippincott, A. Marino, D. N. McKinsey, E. H. Miller, D. C. Moore, B. Mong, B. Monreal, M. E. Monzani , et al. (9 additional authors not shown)

    Abstract: Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomen… ▽ More

    Submitted 21 December, 2021; v1 submitted 4 October, 2021; originally announced October 2021.

    Comments: 19 pages, 10 figures; published version

    Journal ref: Phys. Rev. D 104, 112007 (2021)

  15. Measurement of the Angular Distribution of Wavelength-Shifted Light Emitted by TPB

    Authors: Jackson Schrott, Michinari Sakai, Samuel Naugle, Gabriel Orebi Gann, Scott Kravitz, Daniel McKinsey, Ryan Smith

    Abstract: We present measurements of the angular distribution of re-emitted light from tetraphenyl butadiene thin films when exposed to \SI{128}{nm} light in vacuum. Films ranging from \SI{250}{nm} to \SI{5.5}{\micron} in thickness are measured. All films were fabricated by evaporation deposition on ultraviolet transmitting (UVT) acrylic substrates. Preliminary comparisons of the angular distribution to tha… ▽ More

    Submitted 27 October, 2021; v1 submitted 18 August, 2021; originally announced August 2021.

  16. arXiv:2108.02176  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Scintillation yield from electronic and nuclear recoils in superfluid $^4$He

    Authors: SPICE/HeRALD Collaboration, :, A. Biekert, C. Chang, C. W. Fink, M. Garcia-Sciveres, E. C. Glazer, W. Guo, S. A. Hertel, S. Kravitz, J. Lin, M. Lisovenko, R. Mahapatra, D. N. McKinsey, J. S. Nguyen, V. Novosad, W. Page, P. K. Patel, B. Penning, H. D. Pinckney, M. Pyle, R. K. Romani, A. S. Seilnacht, A. Serafin, R. J. Smith , et al. (9 additional authors not shown)

    Abstract: Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~c… ▽ More

    Submitted 14 May, 2022; v1 submitted 4 August, 2021; originally announced August 2021.

    Comments: 17 pages, 19 figures

    Journal ref: Phys. Rev. D 105, 092005 (2022)

  17. arXiv:2104.13374  [pdf, other

    physics.ins-det nucl-ex

    Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe

    Authors: The LUX-ZEPLIN, Collaboration, :, D. S. Akerib, A. K. Al Musalhi, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araujo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, J. W. Bargemann, D. Bauer, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert , et al. (172 additional authors not shown)

    Abstract: The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t… ▽ More

    Submitted 22 November, 2021; v1 submitted 26 April, 2021; originally announced April 2021.

    Comments: Version accepted for publication in Phys. Rev. C

  18. arXiv:2101.08753  [pdf, other

    astro-ph.IM physics.ins-det

    Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

    Authors: D. S. Akerib, A. K. Al Musalhi, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, J. W. Bargemann, D. Bauer, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger , et al. (162 additional authors not shown)

    Abstract: Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt… ▽ More

    Submitted 21 January, 2021; originally announced January 2021.

    Comments: 14 pages, 6 figures

  19. arXiv:2101.03686  [pdf, other

    physics.ins-det hep-ex physics.app-ph

    The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector

    Authors: E. Bodnia, E. P. Bernard, A. Biekert, E. M. Boulton, S. B. Cahn, N. Destefano, B. N. V. Edwards, M. Gai, M. Horn, N. A. Larsen, Q. Riffard, B. Tennyson, V. Velan, C. Wahl, D. N. McKinsey

    Abstract: Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events a… ▽ More

    Submitted 16 December, 2021; v1 submitted 10 January, 2021; originally announced January 2021.

    Comments: accepted for publication in JINST

    Journal ref: 2021 JINST 16 P12015

  20. arXiv:2011.09602  [pdf, other

    hep-ex astro-ph.CO astro-ph.IM physics.ins-det

    Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, J. Bang, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, A. Fan, S. Fiorucci, R. J. Gaitskell, C. Ghag , et al. (73 additional authors not shown)

    Abstract: This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In… ▽ More

    Submitted 18 November, 2020; originally announced November 2020.

    Comments: 14 pages, 13 figures

    Journal ref: Phys. Rev. D 104, 012011 (2021)

  21. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  22. Investigation of background electron emission in the LUX detector

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, A. Fan, S. Fiorucci, R. J. Gaitskell, C. Ghag, M. G. D. Gilchriese, C. Gwilliam , et al. (71 additional authors not shown)

    Abstract: Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX… ▽ More

    Submitted 13 October, 2020; v1 submitted 16 April, 2020; originally announced April 2020.

    Comments: 17 pages, 13 figures

    Journal ref: Phys. Rev. D 102, 092004 (2020)

  23. arXiv:2004.06304  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, A. Fan, S. Fiorucci, R. J. Gaitskell, C. Ghag, M. G. D. Gilchriese , et al. (72 additional authors not shown)

    Abstract: We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclea… ▽ More

    Submitted 9 December, 2020; v1 submitted 14 April, 2020; originally announced April 2020.

    Comments: 29 pages, 33 figures; minor typos corrected, references updated

    Journal ref: Phys. Rev. D 102, 112002 (2020)

  24. Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: The LUX-ZEPLIN Collaboration, :, D. S. Akerib, C. W. Akerlof, A. Alqahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, J. Bang, D. Bauer, A. Baxter, J. Bensinger, E. P. Bernard, A. Bernstein, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, K. E. Boast , et al. (173 additional authors not shown)

    Abstract: The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par… ▽ More

    Submitted 23 June, 2020; v1 submitted 25 January, 2020; originally announced January 2020.

    Comments: 24 pages, 19 figures; Corresponding Authors: A. Cottle, V. Kudryavtsev, D. Woodward

  25. arXiv:1912.02742  [pdf, other

    nucl-ex physics.ins-det

    Search for two neutrino double electron capture of $^{124}$Xe and $^{126}$Xe in the full exposure of the LUX detector

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, A. Fan, S. Fiorucci, R. J. Gaitskell, C. Ghag, M. G. D. Gilchriese , et al. (74 additional authors not shown)

    Abstract: Two-neutrino double electron capture is a process allowed in the Standard Model of Particle Physics. This rare decay has been observed in $^{78}$Kr, $^{130}$Ba and more recently in $^{124}$Xe. In this publication we report on the search for this process in $^{124}$Xe and $^{126}$Xe using the full exposure of the Large Underground Xenon (LUX) experiment, in a total of of 27769.5~kg-days. No evidenc… ▽ More

    Submitted 19 May, 2020; v1 submitted 5 December, 2019; originally announced December 2019.

    Comments: 8 pages, 3 figures

    Journal ref: J.Phys.G 47 (2020) 10, 105105

  26. Analysis of $^{83m}$Kr Prompt Scintillation Signals in the PIXeY Detector

    Authors: A. G. Singh, A. Biekert, E. Bernard, E. M. Boulton, S. B. Cahn, N. Destefano, B. N. V. Edwards, M. Gai, M. Horn, N. Larsen, B. Tennyson, Q. Riffard, V. Velan, C. Wahl, D. N. McKinsey

    Abstract: Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because $^{83m}$Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a… ▽ More

    Submitted 9 December, 2019; v1 submitted 10 November, 2019; originally announced November 2019.

    Comments: Version edits: corrected typos and references, revised values presented in section 5.1, analysis conclusion is unchanged

  27. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  28. arXiv:1910.04211  [pdf, other

    physics.ins-det hep-ex

    Improved Modeling of $β$ Electronic Recoils in Liquid Xenon Using LUX Calibration Data

    Authors: The LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, A. Baxter, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, A. Fan, S. Fiorucci, R. J. Gaitskell, C. Ghag, M. G. D. Gilchriese , et al. (74 additional authors not shown)

    Abstract: We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $β$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector… ▽ More

    Submitted 28 February, 2020; v1 submitted 9 October, 2019; originally announced October 2019.

    Comments: 17 Pages, 10 Figures, 2 Tables

    Journal ref: Journal of Instrumentation, Volume 15, February 2020

  29. Measurements of Angle-Resolved Reflectivity of PTFE in Liquid Xenon with IBEX

    Authors: S. Kravitz, R. J. Smith, L. Hagaman, E. P. Bernard, D. N. McKinsey, L. Rudd, L. Tvrznikova, G. D. Orebi Gann, M. Sakai

    Abstract: Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off P… ▽ More

    Submitted 30 March, 2020; v1 submitted 18 September, 2019; originally announced September 2019.

    Comments: 21 pages, 10 figures

    Journal ref: Eur. Phys. J. C 80, 262 (2020)

  30. arXiv:1908.06888  [pdf, other

    physics.ins-det hep-ex

    Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon

    Authors: L. Tvrznikova, E. P. Bernard, S. Kravitz, K. O'Sullivan, G. Richardson, Q. Riffard, W. L. Waldron, J. Watson, D. N. McKinsey

    Abstract: As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon Breakdown Apparatus (XeBrA) is a 5-liter cryogenic chamber built to characterize the DC high voltage breakdown behavior of liquid xenon and liquid argon. Electrode… ▽ More

    Submitted 16 December, 2019; v1 submitted 19 August, 2019; originally announced August 2019.

  31. arXiv:1907.06272  [pdf, ps, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Extending light WIMP searches to single scintillation photons in LUX

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, L. de Viveiros, A. Dobi , et al. (100 additional authors not shown)

    Abstract: We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its… ▽ More

    Submitted 27 December, 2019; v1 submitted 14 July, 2019; originally announced July 2019.

    Journal ref: Phys. Rev. D 101, 042001 (2020)

  32. Nuclear Recoil Scintillation Linearity of a High Pressure $^4$He Gas Detector

    Authors: A. Biekert, S. A. Hertel, E. Huebler, J. Lin, H. D. Pinckney, R. K. Romani, A. Serafin, V. Velan, D. N. McKinsey

    Abstract: We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Mo… ▽ More

    Submitted 10 October, 2019; v1 submitted 9 July, 2019; originally announced July 2019.

    Journal ref: 2019 JINST 14 P10028

  33. Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility

    Authors: D. S. Akerib, C. W. Akerlof, S. K. Alsum, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, X. Bai, J. Balajthy, S. Balashov, A. Baxter, E. P. Bernard, A. Biekert, T. P. Biesiadzinski, K. E. Boast, B. Boxer, P. Brás, J. H. Buckley, V. V. Bugaev, S. Burdin, J. K. Busenitz, C. Carels, D. L. Carlsmith, M. C. Carmona-Benitez, M. Cascella , et al. (142 additional authors not shown)

    Abstract: Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with… ▽ More

    Submitted 14 November, 2019; v1 submitted 3 April, 2019; originally announced April 2019.

    Comments: 11 pages, 9 figures

    Journal ref: Astroparticle Physics, Volume 116, Pages 102391 (2020)

  34. arXiv:1903.12372  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, L. de Viveiros, E. Druszkiewicz, S. R. Fallon, A. Fan, S. Fiorucci, R. J. Gaitskell, J. Genovesi , et al. (76 additional authors not shown)

    Abstract: We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.

    Submitted 7 June, 2019; v1 submitted 29 March, 2019; originally announced March 2019.

    Journal ref: Phys. Rev. D 100, 022002 (2019)

  35. arXiv:1811.11241  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, T. J. R. Davison, E. Druszkiewicz, S. R. Fallon, A. Fan, S. Fiorucci, R. J. Gaitskell, J. Genovesi, C. Ghag , et al. (73 additional authors not shown)

    Abstract: The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electr… ▽ More

    Submitted 16 October, 2019; v1 submitted 27 November, 2018; originally announced November 2018.

    Journal ref: Phys. Rev. Lett. 122, 131301 (2019)

  36. arXiv:1810.06283  [pdf, other

    physics.ins-det hep-ex

    A Path to the Direct Detection of sub-GeV Dark Matter Using Calorimetric Readout of a Superfluid $^4$He Target

    Authors: S. A. Hertel, A. Biekert, J. Lin, V. Velan, D. N. McKinsey

    Abstract: A promising technology concept for sub-GeV dark matter detection is described, in which low-temperature microcalorimeters serve as the sensors and superfluid $^4$He serves as the target material. A superfluid helium target has several advantageous properties, including a light nuclear mass for better kinematic matching with light dark matter particles, copious production of scintillation light, ex… ▽ More

    Submitted 3 November, 2019; v1 submitted 15 October, 2018; originally announced October 2018.

    Journal ref: Phys. Rev. D 100, 092007 (2019)

  37. arXiv:1807.07113  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Search for annual and diurnal rate modulations in the LUX experiment

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, T. J. R. Davison, E. Druszkiewicz, S. R. Fallon, A. Fan, S. Fiorucci, R. J. Gaitskell, J. Genovesi, C. Ghag , et al. (71 additional authors not shown)

    Abstract: Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calen… ▽ More

    Submitted 27 September, 2018; v1 submitted 18 July, 2018; originally announced July 2018.

    Comments: 12 pages, 9 figures

    Report number: LLNL-JRNL-757487

    Journal ref: Phys. Rev. D 98, 062005 (2018)

  38. arXiv:1803.10110  [pdf, ps, other

    hep-ex astro-ph.IM physics.ins-det

    Is DAMA Bathing in a Sea of Radioactive Argon?

    Authors: D. N. McKinsey

    Abstract: A hypothesis is proposed to explain the long-standing DAMA/LIBRA puzzle. Introduced into the DAMA/LIBRA shielding is a purge gas of nominally high-purity nitrogen, which under this hypothesis contains argon impurities. Argon is introduced into the nitrogen purge gas either through leaks in the purge gas plumbing, or through commercially-supplied bottled nitrogen, diffuses through materials in the… ▽ More

    Submitted 27 March, 2018; originally announced March 2018.

  39. LUX Trigger Efficiency

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, M. C. Carmona-Benitez, C. Chan, J. E. Cutter, T. J. R. Davison, E. Druszkiewicz, S. R. Fallon, A. Fan, S. Fiorucci, R. J. Gaitskell, J. Genovesi, C. Ghag , et al. (72 additional authors not shown)

    Abstract: The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this paper, the trigger efficiency, which is defined as the probability that an event of interest is selected for offline analysis, is studied using raw data obtained from both electron recoil (ER) and nuclear recoil (NR) calibr… ▽ More

    Submitted 4 September, 2018; v1 submitted 21 February, 2018; originally announced February 2018.

    Comments: 31 pages, 14 figures

  40. Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

    Authors: The LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan, S. Fiorucci , et al. (68 additional authors not shown)

    Abstract: Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing characteristics of liquid xenon in the LUX dark matter detector and develop a pulse shape discriminant to be used for particle identification. To accurately meas… ▽ More

    Submitted 10 May, 2018; v1 submitted 16 February, 2018; originally announced February 2018.

    Comments: 16 pages, 11 figures

    Journal ref: Phys. Rev. D 97, 112002 (2018)

  41. arXiv:1802.06039  [pdf, other

    astro-ph.IM astro-ph.CO hep-ex physics.ins-det

    Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment

    Authors: D. S. Akerib, C. W. Akerlof, S. K. Alsum, H. M. Araújo, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, D. Bauer, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, T. P. Biesiadzinski, K. E. Boast, B. Boxer, P. Brás, J. H. Buckley, V. V. Bugaev, S. Burdin, J. K. Busenitz, C. Carels, D. L. Carlsmith, B. Carlson , et al. (153 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up… ▽ More

    Submitted 2 December, 2019; v1 submitted 16 February, 2018; originally announced February 2018.

    Comments: 14 pages, 11 figures

    Journal ref: Phys. Rev. D 101, 052002 (2020)

  42. Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz, B. N. Edwards, C. H. Faham, S. R. Fallon , et al. (73 additional authors not shown)

    Abstract: The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from ${1.4}\times 10^{4}\;\mathrm{kg\,days}$ of target exposure in 2013, details of the calibration, event-reconstruction, modeling, and statistical tests that underlie the r… ▽ More

    Submitted 15 December, 2017; originally announced December 2017.

    Journal ref: Phys. Rev. D 97, 102008 (2018)

  43. arXiv:1710.11032  [pdf, other

    physics.ins-det hep-ex

    Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber

    Authors: B. N. V. Edwards, E. Bernard, E. M. Boulton, N. Destefano, M. Gai, M. Horn, N. Larsen, B. Tennyson, L. Tvrznikova, C. Wahl, D. N. McKinsey

    Abstract: We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the liquid xenon, corresponding to 4.5 to 13.1 kV/cm in the gaseous xenon. Extraction efficiency continues to increase at the highest extraction fields, implying that… ▽ More

    Submitted 7 January, 2018; v1 submitted 30 October, 2017; originally announced October 2017.

  44. arXiv:1710.02752  [pdf, other

    physics.ins-det hep-ex physics.comp-ph

    Position Reconstruction in LUX

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional fo… ▽ More

    Submitted 12 March, 2018; v1 submitted 7 October, 2017; originally announced October 2017.

    Comments: 30 pages, 17 figures

    Journal ref: Journal of Instrumentation, Volume 13, February 2018, P02001

  45. arXiv:1709.00800  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea… ▽ More

    Submitted 3 September, 2017; originally announced September 2017.

    Comments: 10 pages, 10 figures, 2 tables

    Journal ref: Phys. Rev. D 96, 112011 (2017)

  46. arXiv:1709.00095  [pdf, other

    physics.ins-det hep-ex physics.comp-ph

    3D Modeling of Electric Fields in the LUX Detector

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's a… ▽ More

    Submitted 27 November, 2017; v1 submitted 31 August, 2017; originally announced September 2017.

    Journal ref: JINST 12, no. 11, P11022 (2017)

  47. $^{83\textrm{m}}$Kr calibration of the 2013 LUX dark matter search

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: LUX was the first dark matter experiment to use a $^{83\textrm{m}}$Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^{83\textrm{m}}$Kr calibration applications in the context of the 2013 LUX exposure, including the measurement of temporal and spatial variation in scintillation and charge signal amplitudes, and several methods to unders… ▽ More

    Submitted 8 August, 2017; originally announced August 2017.

    Journal ref: Phys. Rev. D 96, 112009 (2017)

  48. Calibration of a two-phase xenon time projection chamber with a $^{37}$Ar source

    Authors: E. M. Boulton, E. Bernard, N. Destefano, B. N. V. Edwards, M. Gai, S. A. Hertel, M. Horn, N. A. Larsen, B. P. Tennyson, C. Wahl, D. N. McKinsey

    Abstract: We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a $^{37}$Ar source that is directly released into the detector. We map the light and charge yields as a function of electric drift field. For the 2.8 keV peak, we calculate the Thomas-Imel box parameter for recombination and determine its dependence on drift field. F… ▽ More

    Submitted 26 June, 2017; v1 submitted 24 May, 2017; originally announced May 2017.

    Comments: 12 pages, 7 figures

  49. arXiv:1703.09144  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Technical Design Report

    Authors: B. J. Mount, S. Hans, R. Rosero, M. Yeh, C. Chan, R. J. Gaitskell, D. Q. Huang, J. Makkinje, D. C. Malling, M. Pangilinan, C. A. Rhyne, W. C. Taylor, J. R. Verbus, Y. D. Kim, H. S. Lee, J. Lee, D. S. Leonard, J. Li, J. Belle, A. Cottle, W. H. Lippincott, D. J. Markley, T. J. Martin, M. Sarychev, T. E. Tope , et al. (237 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>

    Report number: LBNL-1007256

  50. Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, I. J. Arnquist, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. Bolozdynya, B. Boxer, R. Bramante, P. Brás, J. H. Buckley, V. V. Bugaev , et al. (180 additional authors not shown)

    Abstract: The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,… ▽ More

    Submitted 26 September, 2017; v1 submitted 8 February, 2017; originally announced February 2017.

    Comments: 13 pages, 3 figures, accepted for publication in Astroparticle Physics