Using Nab to determine correlations in unpolarized neutron decay
Authors:
L. J. Broussard,
S. Baeßler,
T. L. Bailey,
N. Birge,
J. D. Bowman,
C. B. Crawford,
C. Cude-Woods,
D. E. Fellers,
N. Fomin,
E. Frlež,
M. T. W. Gericke,
L. Hayen,
A. P. Jezghani,
H. Li,
N. Macsai,
M. F. Makela,
R. R. Mammei,
D. Mathews,
P. L. McGaughey,
P. E. Mueller,
D. Počanić,
C. A. Royse,
A. Salas-Bacci,
S. K. L. Sjue,
J. C. Ramsey
, et al. (6 additional authors not shown)
Abstract:
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and…
▽ More
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
The SeaQuest Spectrometer at Fermilab
Authors:
SeaQuest Collaboration,
C. A. Aidala,
J. R. Arrington,
C. Ayuso,
B. M. Bowen,
M. L. Bowen,
K. L. Bowling,
A. W. Brown,
C. N. Brown,
R. Byrd,
R. E. Carlisle,
T. Chang,
W. -C. Chang,
A. Chen,
J. -Y. Chen,
D. C. Christian,
X. Chu,
B. P. Dannowitz,
M. Daugherity,
M. Diefenthaler,
J. Dove,
C. Durandet,
L. El Fassi,
E. Erdos,
D. M. Fox
, et al. (73 additional authors not shown)
Abstract:
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets…
▽ More
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.
△ Less
Submitted 9 February, 2019; v1 submitted 29 June, 2017;
originally announced June 2017.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Radial distribution of charged particles in a magnetic field
Authors:
S. K. L. Sjue,
L. Broussard,
M. Makela,
P. L. McGaughey,
A. R. Young,
B. A. Zeck
Abstract:
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows…
▽ More
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al. But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a $^{207}$Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Potential future applications of this effect are discussed.
△ Less
Submitted 23 June, 2014;
originally announced June 2014.
-
The PHENIX Forward Silicon Vertex Detector
Authors:
C. Aidala,
L. Anaya,
E. Anderssen,
A. Bambaugh,
A. Barron,
J. G. Boissevain,
J. Bok,
S. Boose,
M. L. Brooks,
S. Butsyk,
M. Cepeda,
P. Chacon,
S. Chacon,
L. Chavez,
T. Cote,
C. D'Agostino,
A. Datta,
K. DeBlasio,
L. DelMonte,
E. J. Desmond,
J. M. Durham,
D. Fields,
M. Finger,
C. Gingu,
B. Gonzales
, et al. (60 additional authors not shown)
Abstract:
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a…
▽ More
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a rapidity range of $1.2<|η|<2.2$ that closely matches the two existing PHENIX muon arms. Each station consists of 48 individual silicon sensors, each of which contains two columns of mini-strips with 75 $μ$m pitch in the radial direction and lengths in the $φ$ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips. The maximum strip occupancy reached in central Au-Au collisions is approximately 2.8%. The precision tracking provided by this device makes the identification of muons from secondary vertices away from the primary event vertex possible. The expected distance of closest approach (DCA) resolution of 200 $μ$m or better for particles with a transverse momentum of 5 GeV/$c$ will allow identification of muons from relatively long-lived particles, such as $D$ and $B$ mesons, through their broader DCA distributions.
△ Less
Submitted 14 February, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.